  9113   Thu Sep 5 15:18:41 2013 JenneUpdateLSCFree swinging DRMI power buildupsI have the DRMI free swinging right now,
since it's not really locking.  Looking
at these time series in the attached pdf,
 DRMI_free_swing_power_buildups.pdf 
  9114   Thu Sep 5 21:07:09 2013 JenneUpdateLSCStarted work on logic for triggeringI want something like an "AND"
for the degree of freedom triggers. 
Koji and I talked through an idea, and I
  
  9116   Fri Sep 6 23:01:08 2013 KojiUpdateLSCStable DRMI lock was recovered from the impact on the RF system modificationSummary
 DRMI.pngSensMat_PRMI_1000cts_580Hz_2013-08-26_235635.pngSensMat_PRMI_1000cts_580Hz_2013-09-06_201137.png 
  9118   Mon Sep 9 20:46:28 2013 MasayukiUpdateLSCMICH calbration[Manasa, Masayuki]
We took a bunch of measurements.
Transfer function and power spectrum using
  
  9121   Tue Sep 10 17:35:50 2013 Masayuki, ManasaUpdateLSCMICH calbration

    

       
            
 MICH_calib_loops.pngOLTF_MICHDC.pngMICH_DC_resp.pngMICH_RF_resp.pngMICH_free_noise.png 
  9122   Wed Sep 11 17:35:38 2013 JenneUpdateLSCALS requirementI have done a quickie look at Optickle
to see how the linewidth of an arm cavity
changes versus the configuration. 
 ArmLinewidthComparison.pngLinewidthComparison.png 
  9127   Thu Sep 12 23:36:25 2013 MasayukiUpdateLSCMICH calbrationFor Modelling of the OLTF, I measured the
response of the BS suspension. I used the
OSEM sensor for measurement. The attatchment1
 BSsus.PNGITMXsus.PNGITMY.PNGfree_running.PNG 
  9128   Fri Sep 13 19:22:01 2013 MasayukiUpdateLSCMICH calbration 
 I made sure the yesterday's
result was collect. I measured not only the
 noise.PNG 
  9131   Mon Sep 16 14:11:47 2013 ranaUpdateLSCMICH calbration  There doesn't seem to be any
coherence among the different directions
of ground motion (as expected from seismic
 Screen_Shot_2013-09-16_at_2.10.31_PM.pngScreen_Shot_2013-09-16_at_2.18.47_PM.png 
  9134   Tue Sep 17 00:50:42 2013 MasayukiUpdateLSCMICH calbrationI found the bug in my calibration
code, and I fixed it.
 noise.PNG 
  9136   Tue Sep 17 18:44:29 2013 MasayukiUpdateLSCLSC calibration screenI update the LSC calibration screen. This
screen is for real time calibration of each
DOF with using error signal and control signal.
 calibration_screen.png 
  9149   Fri Sep 20 22:49:10 2013 MasayukiUpdateLSCLSC calibration screen

    

       
            
 plot.pdf 
  9158   Wed Sep 25 08:11:01 2013 MasayukiSummaryLSCLSC calibration screen 
  
 plot.pdfScreenshot.pngScreenshot-1.pngfringe.pdf 
  9167   Thu Sep 26 23:02:40 2013 ranaUpdateLSCFPMI noise caused by ARM lockingHidden in Nakano-kun's previous entries
was that the phase margin of the X-Arm was
only 9 degrees!! This extremely close to
 Xarm_sweep_130926.pdflsc.pdferr.png 
  9168   Fri Sep 27 00:48:53 2013 MasayukiUpdateLSCFPMI noise caused by ARM locking

    

       
            
 phase_badget.pngFPMI_noises.png 
  9169   Fri Sep 27 13:55:11 2013 MasayukiUpdateLSCLSC calibration screen  I added the DAQ channel to
all output of calibration servo. The name
of channels are C1CAL_(plant name)_W_OUT_DQ.
  
  9172   Fri Sep 27 21:01:50 2013 MasayukiUpdateLSCLSC calibration screen 
 I fixed the XARM and YARM real
time calibration servo.
  
  9174   Mon Sep 30 11:33:15 2013 ranaUpdateLSCLSC calibration screen

    

       
            
  
  9187   Thu Oct 3 00:01:59 2013 rana, jenneHowToLSCsteps to full IFOIn moving now to full  front_matrix.jpg 
  9189   Thu Oct 3 01:18:57 2013 KojiHowToLSCsteps to full IFOI vote on PRMI+1arm -> PRFPMI   
  9191   Thu Oct 3 02:43:34 2013 rana, jenneSummaryLSCPRMI: comparison of 1f and 3f signals w/ calibrationThe attached plot shows the spectra of
all the REFL signals with the PRMI SB lock.
We excited the ITMY_LSC with 3000
 REFL_signals_CalLinesLinedUp.pdf 
  9193   Thu Oct 3 02:51:26 2013 JenneUpdateLSCPRMI locked "forever", some ALS fiddlingFirst up for me this evening was getting
the PRMI locked.
I used the IFO configure screen to
 PRMI_lock_ASSatBeginningAndEnd.png 
  9213   Mon Oct 7 13:55:26 2013 JenneUpdateLSCArms locked in IR for many hoursSomeone left the arms aligned, and the
LSC engaged, so the arms have been locked
almost continuously for several days
 BothArmsLocked3Days_7Oct2013.png 
  9214   Mon Oct 7 14:15:10 2013 JenneUpdateLSCPRMI alignment is also excellentSomething is really excellent with the
alignment today, or something has changed
with the POP path / electronics.  While
 PRMI_excellent_alignment_7Oct2013.png 
  9215   Mon Oct 7 14:24:10 2013 JenneUpdateLSCPRMI Config settings re-savedI have resaved the PRMI locking settings
in the IFO Config screen.  Nothing has
changed, except that I have put a 1e-4 into
  
  9217   Mon Oct 7 18:36:39 2013 JenneUpdateLSCSensing Matrix scripts updatedI discovered that I was not getting enough
SNR on all the refl RFPDs when I actuated
using the Sensing Matrix script.  The
  
  9218   Mon Oct 7 18:39:29 2013 JenneSummaryLSCPRMI: REFL11 beam realigned

    

       
            
  
  9222   Tue Oct 8 16:56:38 2013 JenneUpdateLSCLSC model sensing matrix upgrades in progressI have modified the LSC model (the
currently-running model is checked into the
svn), but it is not compiling for me. 
  
  9225   Wed Oct 9 17:27:35 2013 JenneUpdateLSCLSC model sensing matrix upgrades The modifications to the LSC model are
now complete, and the new model has been
compiled, installed, and is running. The
  
  9227   Wed Oct 9 22:05:55 2013 JenneUpdateLSCNew lockin / sensing matrix screensAfter finishing up working on the models
for today, I made corresponding screens.
 
  
  9234   Fri Oct 11 17:37:08 2013 JenneUpdateLSCNew lockin / sensing matrix screens

    

       
            
  
  9236   Sun Oct 13 13:29:09 2013 ranaUpdateLSCNew lockin / sensing matrix screens  I think that we always drive
above the UGF for sensing matrix measurements
since we like to put notches in the servo.
  
  9237   Mon Oct 14 17:40:15 2013 JenneUpdateLSCNew lockin / sensing matrix screens Hmmmm, yup.  I forgot to pay
attention to what the UGFs of our LSC loops
are when I was picking a low-noise region. 
  
  9239   Mon Oct 14 21:12:35 2013 JenneUpdateLSCNew lockin / sensing matrix screensAfter staring and thinking, I remembered
that there is a limit to the number of characters
that a channel name can have.  So, I
  
  9243   Wed Oct 16 02:27:56 2013 JenneUpdateLSCPRMI + 2 arm attempt

[Masayuki, Jenne]
 
Masayuki  informed me
that the Xarm ALS was feeling pretty good
 PRCL_OLTF_PRMIir_XARMgreen_16Oct2013.pdfMICH_OLTF_PRMIir_XARMgreen_16Oct2013.pdfTimeSeries_PRMI_2arms_16Oct2013.png 
  9244   Wed Oct 16 02:39:24 2013 ranaUpdateLSCPRMI + 2 arm attempt 
 that's
some hot stuff
  
  9245   Wed Oct 16 03:04:37 2013 JenneUpdateLSCNew lockin / sensing matrix model parts

    

       
            
  
  9247   Wed Oct 16 17:34:28 2013 JenneUpdateLSCPRMI + 2 arm attemptKoji reminded me that we should also save
the data from the PRMI+Xarm, just in case
we want to look at it later.
 TimeSeries_PRMI_Xarm_16Oct2013.png 
  9250   Thu Oct 17 13:40:55 2013 JenneUpdateLSCNew lockin / sensing matrix frequenciesI locked PRMI, and (after fixing the POP
QPD situation, noted in elog
9249) took power spectra of all the REFL
 All_REFL_PRMI_17Oct2013.pdf 
  9251   Thu Oct 17 18:29:28 2013 KojiUpdateLSCPRMI+2arm attempt (not really yet)While Manasa, Jenne, and Masayuki are working
on the preparing the interferometer, I write
the elog for them.
  
  9270   Wed Oct 23 19:28:22 2013 JenneUpdateLSCNew lockin / sensing matrix model partsI have modified the Sensing Matrix I,Q
to Mag, Phase library part in the new sensing
matrix system.
  
  9274   Thu Oct 24 04:13:15 2013 JenneUpdateLSCPRMI + 2 ALS arms[Masayuki, Jenne, Rana]
We have, for the
  
  9275   Thu Oct 24 08:04:54 2013 SteveUpdateLSCPRMI + 2 ALS arms 
 Nice work. Congratulation
  
  9276   Thu Oct 24 09:08:27 2013 jamie.UpdateLSCPRMI + 2 ALS armsnice.   
  9279   Thu Oct 24 14:14:18 2013 ranaUpdateLSCPRMI + 2 ALS arms Just in case people were confused,
although the PRMI + 2 ALS arms were controlled,
we weren't able to bring them in to resonance.
  
  9280   Thu Oct 24 15:19:58 2013 KojiUpdateLSCPRMI + 2 ALS arms> all of complications
of handing off
  
  9286   Thu Oct 24 23:25:37 2013 JenneUpdateLSCEnd transmission triggering

    

       
            
  
  9289   Fri Oct 25 04:03:40 2013 MasayukiUpdateLSC'scope and spectrum analyser for REFL165As Jenne's Elog we want to see Spectrum
and time series of REFL 165 (our PRMI LSC
locking PD) to see if the signal is saturated
  
  9293   Fri Oct 25 20:11:08 2013 JenneUpdateLSCMICH gain in PRMI lowered by factor of 2We were locking the PRMI, but it is very
rumbly today.  I reduced the MICH servo
gain from -0.8 to -0.4 , and things seem
  
  9294   Fri Oct 25 21:28:49 2013 MasayukiUpdateLSCREFL PDs spectrum I measured the spectrum of the REFL165
output using AG4395A. As this entry
we put the directional coupler between REFL165
 REFL.pngREFLspe.zip 