  7035   Thu Jul 26 02:44:17 2012 JenneUpdateIOOCentering the MCR camera[Yaakov, Jenne]
The
short version:
  
  7034   Wed Jul 25 23:03:22 2012 ranaUpdatedigital noisenotch, lowpass filtersIf the problem is the precision in DTT,
then why would the noise change when the
corner frequency of the filter is changed?
  
  7033   Wed Jul 25 22:16:36 2012 KojiUpdateLSCringdown measurementIs this the step response of the single
pole low pass???
It should have an exponential decay,
  
  7032   Wed Jul 25 17:35:44 2012 LizUpdateComputer Scripts / ProgramsSummary Pages are in the right place!The summary pages can now be accessed from
the "Daily Summary" link under
LOGS on the 40 meter Wiki page.
  
  7031   Wed Jul 25 16:55:01 2012 DenUpdatedigital noisenotch, lowpass filters Direct Form 2 is noisy in the first
test. This is the one similar to Matt's in
his presentation. Input signal was a sine
 6x 
  7030   Wed Jul 25 16:31:01 2012 JenneUpdateLSCYarm green locking to arm - PDH box saturating

    

       
            
  
  7029   Wed Jul 25 15:33:55 2012 janoschUpdateLSCringdown measurementWe did our first ringdown measurement on
the Y arm. First we tried to keep the arm
locked in green during the ringdown, but
 Rindown1.png 
  7028   Wed Jul 25 14:35:45 2012 SashaSummarySimulationsSURF - Week 5 - Summary

    

       
            
 Screen_Shot_2012-07-25_at_2.20.01_PM.pngScreen_Shot_2012-07-25_at_2.20.15_PM.pngScreen_Shot_2012-07-25_at_2.20.29_PM.pngScreen_Shot_2012-07-25_at_2.23.05_PM.png 
  7027   Wed Jul 25 12:00:21 2012 YaakovUpdateSTACISWeekly updateThe past few days I've been working on
making a noise budget for the
  
  7026   Wed Jul 25 11:41:00 2012 YaakovUpdateVIDEOCentering the MCR camera

    

       
            
  
  7025   Wed Jul 25 11:34:31 2012 EricSummarySimulationsSURF UpdateI am continuing work on simulating the
DARM control loop. There is now a block for the length response
 DARM_control_loop_hendries.PNGOLG_old_hendries2.png 
  7024   Wed Jul 25 11:25:27 2012 MashaUpdateGeneralSummaryThis week, I have been mainly working on
my new neural network project, and working
with the BLRMS channels.
  
  7023   Wed Jul 25 11:22:39 2012 LizUpdateComputer Scripts / ProgramsWeek 6 updateThis week,
I made several modifications to the Summary
 P7230026.JPGP7230031.JPG 
  7022   Wed Jul 25 10:31:33 2012 SashaSummarySimulationsSURF - Week 5 - SummaryThis week I've been working on refining
my simulation and getting it
 Screen_Shot_2012-07-24_at_10.46.05_AM.pngScreen_Shot_2012-07-24_at_10.45.43_AM.pngScreen_Shot_2012-07-25_at_10.16.58_AM.pngScreen_Shot_2012-07-25_at_10.25.27_AM.png 
  7021   Tue Jul 24 21:16:55 2012 DenUpdatedigital noisequantization testI'm trying to get some intuition how digital
noise due to quantization shows up in iir
filters. I decided to do tests in C using
 iir_2.pngiir_8.png 
  7020   Tue Jul 24 18:33:12 2012 YaakovUpdateVIDEOCentering the MCR cameraJenne and I centered the MCR camera   
  7019   Tue Jul 24 15:17:10 2012 MashaUpdatePEMRMS Filters, PEM SitemapRMS Filters
How Den, Rana, and I chose RMS filters:
 GUR1Z0p3to1FilterCoherence.pngGUR1Z3to10FilterCoherence.pngGUR1Z3to10FilterSignal.png 
  7018   Tue Jul 24 12:06:41 2012 MashaUpdatePEMNew RMS channels, New C1PEM OverviewAs Jenne suggested last night, I changed
the C1PEM overview in Epics. Previously,
the C1PEM_OVERVIEW.adl screen had two separate
 NewRMSFrames.png 
  7017   Tue Jul 24 03:14:13 2012 JenneUpdateASSCalibration of MC ASS lockinsI wanted to check that the calibration
of the MC ASS lockins was sensible, before
trusting them forevermore.
  
  7016   Tue Jul 24 02:12:14 2012 MashaUpdatePEMBLRMS, MEDM, TriangulationToday I worked with the BLRMS channels,
re-triangulated the seismometers (the STS
is now on the very end of the Y-arm, while
  
  7015   Mon Jul 23 21:54:48 2012 ranaUpdatePEMWeather Station Works!To get the code to run on c1pem1, we had
to move the old target back into the /cvs/cds/caltech/target/
directory.  It is in /cvs/cds/caltech/target/c1pem1/.
 Untitled.png 
  7014   Mon Jul 23 21:17:58 2012 LizUpdatePEMWeather Station Works!Rana and I traced the cables that ran from
c1pem1 to the
  
  7013   Mon Jul 23 20:34:38 2012 JamieOmnistructureComputersCHECK IN YOUR CHANGES TO THE SVNI'm seeing LOTS OF STUFF NOT CHECKED INTO
THE SVN!!!  both modified
  
  7012   Mon Jul 23 20:19:01 2012 LizUpdateComputer Scripts / ProgramsInput Needed (From everyone!)The summary pages
are now online
  
  7011   Mon Jul 23 19:50:43 2012 JamieUpdateCDSc1gcv model renamed to c1alsI decided to rename the c1gcv model to
be c1als.  This is in an ongoing effort
to rename all the ALS stuff as ALS, and get
  
  7010   Mon Jul 23 19:13:12 2012 JenneUpdatePSLPSL channels added to IOO model

    

       
            
  
  7009   Mon Jul 23 19:00:26 2012 KojiUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThis is a good modification. We just need
to check how the ALS scripts are affected.

  
  7008   Mon Jul 23 18:57:52 2012 JamieUpdateCDSc1scx and c1scy models recompiled and restartedAfter the changes listed in 7005
and 7007,
I have rebuilt, installed, and restarted
  
  7007   Mon Jul 23 18:41:15 2012 JamieUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThe end sus models (c1scx and c1scy) both
contain some ALS stuff.  This stuff
could maybe be moved to their own models,
 alsend.png 
  7006   Mon Jul 23 18:38:58 2012 JenneUpdatePSLPSL channels added to IOO modelI added a subblock to the IOO model, and
gave it a top_names of PSL, so the channels
show up as C1:PSL-......
  
  7005   Mon Jul 23 18:16:13 2012 JamieUpdateSUSDQ block added to sus_single_control library partsI have added a DQ block to the sus_single_control
library part.  This means that all sus
models will automatically generate DQ channels
  
  7004   Mon Jul 23 18:01:30 2012 JenneUpdateGreen LockingYarm ALS laser is funny / dying I turned the Yend laser back on....it
hasn't turned itself off yet, but I'm watching
it.  As long as we leave the shutter
  
  7003   Mon Jul 23 17:39:34 2012 JenneUpdateIOOMC_F vs. MC_L[Rana, Jenne]
We looked at the different outputs
of the MC servo board to make sure they make
 MCF_vs_MCL_23July2012.pdf 
  7002   Mon Jul 23 13:30:06 2012 JenneUpdateGreen LockingYarm ALS laser is funny / dyingJamie and I were doing some locking, and
we found that the Yarm green wasn't locking. 
It would flash, but not really stay locked
  
  7001   Mon Jul 23 07:39:55 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:Note:  The Conlog install instructions that
I started from were located here:
https://awiki.ligo-wa.caltech.edu/aLIGO/Conlog
  
  7000   Sat Jul 21 18:04:02 2012 DenUpdateAdaptive Filteringfrequency domain filterI've implemented online frequency domain
filter and applied it to MC_F.
 freq_af.png 
  6999   Sat Jul 21 14:48:33 2012 DenUpdateCDSRCGAs I've spent many hours trying to determine
the error in my C code for online filter
I decided to write about it to prevent people
  
  6998   Sat Jul 21 14:05:21 2012 DenUpdatePSLPMC problems examined

    

       
            
 fss_slowm.png 
  6997   Fri Jul 20 17:11:50 2012 JamieUpdateCDSAll custom MEDM screens moved to cds_users_apps svn repoSince there are various ongoing requests
for this from the sites, I have moved all
of our custom MEDM screens into the cds_user_apps
  
  6996   Fri Jul 20 14:18:15 2012 DenUpdatePEMMCL, GUR calibrationI did a raw calibration of MCL and GUR.
Accuracy is a factor of 2.
GUR path : 800 V/m/s => readout
 LIGO_S5_S6.eps 
  6995   Fri Jul 20 12:12:25 2012 ranaUpdatePSLPMC problems examinedJenne, Den, Rana
The PMC transmission has been varying
a lot and the MC seems unstable. Superstitious
 Untitled.png 
  6994   Fri Jul 20 11:59:27 2012 ranaUpdateComputer Scripts / ProgramsCONLOG not runningWE tried to use the new conlog today and
discovered that:
1) No one at the 40m uses conlog
  
  6993   Thu Jul 19 15:55:21 2012 ranaUpdateComputersused 'aptitude' to install software (TexLive) on rosalbaI used APTITUDE
to install texlive-full on rosalba so that
I could work on a paper. pdflatex was not
  
  6992   Thu Jul 19 02:32:45 2012 JenneUpdateIOOWFS don't come on automatically??The MC unlocked ~20 min ago, correlated
with 2 consecutive earthquakes in Mexico. 
The MC came back fine after a few minutes,
  
  6991   Thu Jul 19 02:14:37 2012 JenneUpdateVIDEOMade a video guiI learned a little bit of python scripting
while looking at the videoswitch script,
and I made a video medm screen. 
  
  6990   Wed Jul 18 15:38:05 2012 EricSummarySimulationsSURF UpdateMost of my work has been on continuing to develop the
Simulink model of the differential arm length
  
  6989   Wed Jul 18 14:25:44 2012 JenneUpdateIOOMC spot position measurementsThe script ....../scripts/ASS/MC/mcassMCdecenter 
takes ~17 minutes to run.  The biggest
time sink is measuring a no-offset-added-to-coil-gains
  
  6988   Wed Jul 18 13:53:34 2012 YaakovUpdateSTACISWeekly updateI have been working on substituting the
internal geophones in the STACIS with accelerometers,
and this week specifically I have been trying
 flange.JPGreally_accelFeed.GIF 
  6987   Wed Jul 18 11:05:40 2012 MashaUpdatePEMSTS CohereneI realized what the ADC channel mismatch
was, and apologize for plotting a terrible
coherence in log scale. The channels are
  
  6986   Wed Jul 18 10:08:01 2012 LizUpdateComputer Scripts / ProgramsWeek 5 update/progressOver the past week, I have been focusing
on the issues I brought up in my last ELOG, 
  
ELOG V3.1.3-