  8601   Mon May 20 18:47:47 2013 KojiUpdateLSCPRMI sensing matrix - not high quality dataFor now forget about the demodulation phase
and assume all of the ports are independent.
  
  8603   Tue May 21 14:48:08 2013 JenneUpdateLSCPRMI sensing matrix - not high quality dataThe PRMI sensing matrix, as measured last
Thursday, in a more readable format:
EDIT: DON'T Look at this
  
  8633   Thu May 23 20:39:50 2013 JenneUpdateLSCPRMI sensing matrix measured at 580.1HzI locked the PRMI and remeasured the sensing
matrix, this time at 580Hz.  The excellent
news here is that the matrix looks quite
 SensMat_23May2013.png 
  8636   Thu May 23 22:13:12 2013 KojiUpdateLSCPRMI sensing matrix measured at 580.1HzCan you clarify the definition of the phase
"0deg" of your plot?
Is "I" the definition of
  
  8640   Fri May 24 13:41:19 2013 JenneUpdateLSCPRMI sensing matrix measured at 580.1Hz"0 degrees" is 0 degrees of demod
phase.  I have now added the PD demod
phases to the plot:
 SensMat_23May2013_withIQ.png 
  8641   Fri May 24 14:01:59 2013 KojiUpdateLSCPRMI sensing matrix measured at 580.1HzIt's hard to believe but is AS55Q really
almost insensitive to MICH?
Well, anyway, now it is the time
  
  8644   Fri May 24 22:18:33 2013 JenneUpdateLSCPRMI sensing matrix: Got it!Okay, I think I am finished with the sensing
matrix scripts!  
I had the syntax for atan2() wrong,
 SensMat_23May2013_withIQ_andCorrectPhases.png 
  8648   Tue May 28 14:52:56 2013 JenneUpdateLSCPRMI sensing matrix: Got it!Just so we have it, here is the re-analysis
with the correct plot and phases for the
May 21st data, taken near the violin mode:
 SensMat_21May2013_withIQ_andCorrectPhases.png 
  8650   Tue May 28 17:06:04 2013 KojiUpdateLSCPRMI sensing matrix: Got it!- We want to add POX11/POY11 in the collection.
They may indicates some abnormal asymmetry
between two arms (for PRMI).
  
  8642   Fri May 24 14:40:22 2013 JenneUpdateLSCPRMI sensing matrix: now what?

    

       
            
  
  8177   Wed Feb 27 01:09:53 2013 yutaUpdateLockingPRMI sideband/carrier locked[Jenne,Yuta]

We succeeded in locking PRMI in sideband
 6x 
  11197   Fri Apr 3 05:17:36 2015 JenneUpdateLSCPRMI to 1f twelve timesI have 12 tick marks for times I got all
the way to 1f for all 4 degrees of freedom
in the PRFPMI.  The CARM / DARM transitions
  
  11187   Wed Apr 1 03:54:15 2015 JenneUpdateLSCPRMI to 1f twiceI got the PRMI transitioned from REFL165
over to REFL55 two times tonight.  Also,
I had 2 long-ish locks, one 9 minutes, and
 FirstLock_9min_arms150_1154pm.png 
  8385   Mon Apr 1 17:59:04 2013 JenneUpdateLockingPRMI videos[Gabriele's work, I'm just spectating]
Annalisa is working on finding the
PSL/AUX laser beatnote, so the PSL temp is
  
  8030   Fri Feb 8 02:12:14 2013 JenneUpdateLockingPRMI work[Jenne, Yuta]
Lots
  
  8031   Fri Feb 8 02:38:04 2013 KojiUpdateLockingPRMI workI feel it's too hasty to use the PRMI.

I support the idea of the  half-PRC
  
  8032   Fri Feb 8 11:01:18 2013 JamieUpdateLockingPRMI workI completely agree with Koji.  We
definitely should have locked the half PRC
first.  We were all set up for that. 
  
  8034   Fri Feb 8 12:39:32 2013 yutaUpdateLockingPRMI workHalf-PRC at this time already have two
changes from the previous half-PRC; PR2 replaced/flipped
and different TM before BS.
  
  8037   Fri Feb 8 15:53:48 2013 JenneUpdateLockingPRMI work

    

       
            
  
  8039   Fri Feb 8 17:41:34 2013 JenneUpdateLockingPRMI work 
 [Yuta, Jenne]
After much tweaking of the alignment
  
  8042   Fri Feb 8 19:39:02 2013 KojiUpdateLockingPRMI workIt seems that the cavity trans looks much
better than before. Cool.
  
  8043   Fri Feb 8 20:05:15 2013 JenneUpdateLockingPRMI workI fixed up the POP path so that there is
no clipping, so that Yuta can take a cavity
mode scan.
  
  6886   Thu Jun 28 00:50:48 2012 yutaUpdateLockingPRMI work started, commissioning planMy goal for tonight was to lock PRMI,
 grasp the current situation
by my eye,
 POP_1024903948.bmpREFL_1024903929.bmpAS_1024903921.bmp 
  6887   Thu Jun 28 01:44:57 2012 KojiUpdateLockingPRMI work started, commissioning planTo be fair, this is Kiwamu's idea. And
nothing is reasonable before it is confirmed
quantitatively.
  
  6888   Thu Jun 28 15:21:02 2012 ranaUpdateLockingPRMI work started, commissioning plan 
 Cycling the vacuum is easy.
Why not vent starting Thursday evening and
  
  8992   Fri Aug 9 22:51:37 2013 KojiUpdateLSCPRMI(sb) lock recoveredPRMI(sb) lock
was recovered
  
  8994   Mon Aug 12 10:44:22 2013 ranaUpdateLSCPRMI(sb) lock recovered  In the past, we used to use
Stefan's 'ezcademod' or Matt's 'ezlockin'
to do auto phase adjustment.
  
  10068   Thu Jun 19 00:02:48 2014 JenneUpdateLSCPRMI+2 arms recoveryArms locked in comm and diff with ALS.
PRMI locked with REFL33 I&Q while arms
off resonance. Having trouble reducing CARM
  
  9251   Thu Oct 17 18:29:28 2013 KojiUpdateLSCPRMI+2arm attempt (not really yet)While Manasa, Jenne, and Masayuki are working
on the preparing the interferometer, I write
the elog for them.
  
  9413   Tue Nov 19 17:47:17 2013 JenneUpdateLSCPRMI+2arms attemptSo far this afternoon, I have redone the
IFO alignment, locked both arms with ALS,
moved both arms off resonance, locked PRMI,
  
  8871   Thu Jul 18 15:55:31 2013 JenneUpdateLSCPRMI+Y arm ALS Sensing MatricesLast
night, I took sensing matrix data at various
different offsets for the Yarm. 
 SensMatMeas_17July2013_PRMI_YarmOffResonance.pngSensMatMeas_17July2013_PRMI_YarmMidResonance.pngSensMatMeas_17July2013_PRMI_YarmOnResonance.png 
  8872   Thu Jul 18 16:30:08 2013 KojiUpdateLSCPRMI+Y arm ALS Sensing MatricesHmm. I agree that something was funny.

Let's take the matrix without the
  
  8867   Thu Jul 18 02:21:41 2013 KojiUpdateLSCPRMI+Y arm ALS success![Koji, Jenne, Manasa, Annalisa, Rana,
Nic]
 Screenshot-Untitled_Window1.pngPRMI_Yarm.pdf 
  8868   Thu Jul 18 10:47:21 2013 JamieUpdateLSCPRMI+Y arm ALS success!AWESOME!  You guys rock.   
  8869   Thu Jul 18 10:50:54 2013 LisaUpdateLSCPRMI+Y arm ALS success!

    

       
            
  
  8879   Fri Jul 19 12:02:18 2013 manasaUpdateLSCPRMI+Y arm ALS success!Data retrieved using getdata (30 minutes
trend) saved at
  
  9068   Tue Aug 27 02:18:28 2013 JenneUpdateLSCPRMI, DRMI sensing matricesI have made a measurement of the PRMI and
the DRMI sensing matrices. 
Keiko pointed out to me in an email
 SensMatMeas_26Aug2013_withErrorBars.pngSensMatMeas_26Aug2013_DRMI_firstEverMeasurement.png 
  9460   Thu Dec 12 21:30:52 2013 JenneUpdateASCPRMI-relevant oplevs centeredThe ITM oplevs were pretty close to the
edge of their ranges, and none of the oplevs
have been centered in a while, so I centered
  
  9218   Mon Oct 7 18:39:29 2013 JenneSummaryLSCPRMI: REFL11 beam realigned

    

       
            
  
  9191   Thu Oct 3 02:43:34 2013 rana, jenneSummaryLSCPRMI: comparison of 1f and 3f signals w/ calibrationThe attached plot shows the spectra of
all the REFL signals with the PRMI SB lock.
We excited the ITMY_LSC with 3000
 REFL_signals_CalLinesLinedUp.pdf 
  9687   Mon Mar 3 22:21:43 2014 KojiSummaryLSCPRMIsb locked with REFL165I&QSuccessful
PRMIsb locking with REFL165I/Q
My
  
  9753   Wed Mar 26 14:54:32 2014 KojiSummaryLSCPRMIsb locked with REFL165I&Q again[Manasa, Eric, Koji]
PRMIsb
was locked with REFL165I&Q.
  
  9754   Wed Mar 26 21:51:42 2014 ericqSummaryLSCPRMIsb locked with REFL165I&Q againIncidentally, while messing around with
transfer functions and sensing matrix elements
this evening, I was able to sideband lock
  
  9758   Fri Mar 28 17:22:55 2014 KojiSummaryLSCPRMIsb locked with REFL165I&Q againWhile I'm looking at the PRM ASC servo
model, I tried to use the current servo
filters for the ASC 
  
  15983   Thu Apr 1 00:50:06 2021 gautamUpdateSUSPRMdiagI spent some time investigating the PRM
this evening, trying out some of the stuff
we discussed in the meeting.
  
  7921   Sat Jan 19 16:02:28 2013 ranaOmnistructureElectronicsPS cleanupDuring our 'Women in Physics' tours today,
we were reminded that there are several bench
power supplies being used as permanent inside.
  
  9467   Fri Dec 13 16:34:20 2013 SteveUpdateVACPS will be replaced next week

    

       
            
 hotPSvacRack.jpgfan1X8.jpg 
  10151   Tue Jul 8 09:02:02 2014 AkhilUpdateElectronicsPSD Plots for different sampling times of the Frequency Counter Although there were few timing issues
with the FC and the Raspberry Pi at the lowest
sampling time of the FC (0.1s) even after
 7x 
  11458   Wed Jul 29 11:15:21 2015 JessicaSummaryLSCPSDs of Arms with seismometer subtractionIgnacio and I downloaded data from the
STS, GUR1, and GUR2 seismometers and from
the mode cleaner and the x and y arms. The
 Arms_PSD.pngXArm_PSD.pngYArm_PSD.png 
  81   Wed Nov 7 16:07:03 2007 steveUpdatePSLPSL & IOO trend1.5 days of happy psl-ioo with litle bumps
in C1:PSL-126MOPA_HTEMP
 psl1.5dtrend.jpg 