  8357   Tue Mar 26 17:27:17 2013 KojiUpdateIOOTuning MC length/FSRPlease add the discussions on the cavity
absolute length (and its change, adjustment
precision),
  
  8426   Tue Apr 9 00:32:39 2013 ranaConfigurationIOOTurn on MCL Listening to the free swinging Y-arm,
its clear that the fringe velocity is higher
with the MCL path off, than on. I checked
  
  8434   Wed Apr 10 03:59:41 2013 DenConfigurationIOOTurn on MCL

    

       
            
 MCL.pdf 
  8469   Mon Apr 22 11:46:09 2013 KojiSummaryIOOMC locked/aligned. MC WFS offloading by ezcaservoЕру ьс шы
тщц дщслув
фтв фдшптувю
  
  8471   Mon Apr 22 17:06:42 2013 ranaSummaryIOOMC locked/aligned. MC WFS offloading by ezcaservo 
 Why use the PSL beam as a reference?
Don't we want to keep the MC pointing in
  
  8530   Mon May 6 19:04:30 2013 JamieUpdateIOOmode cleaner not lockingAbout 30 minutes ago the mode cleaner fell
out of lock and has since not been able to
hold lock for more than a couple seconds.
  
  8531   Mon May 6 21:05:06 2013 rana, Jamie, KOjiUpdateIOOmode cleaner not lockingAs it turned out, the setting of +26dB
for the FSS Fast gain was making the NPRO
PZT / Pockels cell crossover too unstable.
  
  8534   Tue May 7 03:25:28 2013 JenneUpdateIOOMC WFS drifting??I'm not sure why, but starting ~3.5 hours
ago, the WFS seem to not be holding the MC
in optimal alignment. 
  
  8575   Tue May 14 20:30:29 2013 JamieSummaryIOOMC error spectrum at various FSS gain settings.I used the Agilent 4395A and the GPIB network
bridge to measure the MC error spectrum at
the MC servo board.
 7x 
  8587   Thu May 16 01:41:31 2013 JenneSummaryIOOFSS gain settings set

    

       
            
  
  8627   Thu May 23 10:48:42 2013 ManasaUpdateIOOMC autolocker and MCWFS enabledSome strong seismic noise (not related
to any earthquakes - watchdogs are all green)
had got the MC unlocked this morning.
  
  8647   Tue May 28 11:11:37 2013 ManasaUpdateIOOMC aligned[Jenne, Manasa]
Fixed crappy alignment of MC by moving
MC mirrors. MC REFL PD measured 0.5 after
 MC_0528.png 
  8673   Tue Jun 4 20:19:07 2013 ranaConfigurationIOOChanged threshold for FSS SLOW loopThe FSS SLOW actuator often   
  8718   Tue Jun 18 18:24:07 2013 ManasaUpdateIOOMC WFS turned OFF[Jenne, Jamie, Manasa]
Jamie was working on the MC guardian
today (I think he will elog about this soon).
  
  8724   Wed Jun 19 15:07:20 2013 ranaUpdateIOOWFS debuggingTrying to figure out what's wrong with
the MC WFS:
1) The symptom seems to be that the
  
  8733   Thu Jun 20 15:15:39 2013 ranaUpdateIOOWFS debuggingTried a bunch of stuff, but eventually
just turned off the TRANS_QPD loops and loops
are stable. Needs more debugging. 
 Untitled.png 
  8735   Thu Jun 20 20:46:16 2013 gautamUpdateIOOWFS debugging-QPD debugging 
 I wanted to make sure that
the QPD map on the C1IOO_MC_TRANS_QPD.adl
 MC2_QPD-map.png 
  8756   Wed Jun 26 13:37:13 2013 JenneUpdateIOOMC very misaligned - put backNot sure why it was so poorly aligned,
since the misalignment "event"
happened while we were all away at lunch,
  
  8794   Wed Jul 3 10:39:25 2013 manasaUpdateIOOMC aligned and WFS enabledI found WFS had been left disabled from
sometime yesterday. I don't see anyone mentioning 
when and why they had turned OFF the WFS
  
  8815   Tue Jul 9 20:09:53 2013 KojiUpdateIOOWFS debuggingThe low UGFs of the MC WFS servos made
the MC insane thesedays: 
The servos are too slow and we kept
  
  8843   Sun Jul 14 17:47:28 2013 KojiUpdateIOOMC WFS maintenanceAnnalisa notified me that the MC autolocker
could not keep the MC locked.
I found the initial alignment was
  
  8906   Tue Jul 23 13:55:08 2013 KojiUpdateIOOMC manually alignedThe MC was manually aligned. The spot positions
were measured and it is consistent with the
measurements done yesterday.
 MCalignment.pngMCspot.png 
  8913   Tue Jul 23 21:32:43 2013 KojiUpdateIOOFound the cause of mysterious MC motionThesedays
we were continuously annoyed by unELOGGED
activities of the interferometer.
  
  8917   Wed Jul 24 14:26:24 2013 ranaUpdateIOOFound the cause of mysterious MC motionYes, this was not ELOG'd by me, unfortunately.
This was the MC tickler which I described
to some people in the control room when I
  
  9030   Mon Aug 19 11:30:20 2013 JenneUpdateIOOMC mirrors' ASC has non-zero inputs[Masayuki, Jenne]
When I came in this morning, I noticed
that the Mode Cleaner had not been locked
  
  9032   Mon Aug 19 15:23:07 2013 KojiUpdateIOOMC mirrors' ASC has non-zero inputs[Jenne, Koji]
This disturbance in the MC ASC channels
were fixed.
  
  9046   Wed Aug 21 19:26:19 2013 ranaUpdateIOOFound the cause of mysterious MC motion

    

       
            
  
  9148   Fri Sep 20 20:27:18 2013 ranaUpdateIOOmode cleaner not locking I used our procedure from this
entry to set the IMC board offset as
well as the FSS board offset.
  
  9153   Sun Sep 22 22:54:28 2013 ranaUpdateIOOmode cleaner not lockingHaving trouble again, starting around 1
hour ago. No one in the VEA. Adjusted the
offset -seems to be OK again.
  
  9175   Mon Sep 30 13:02:51 2013 Masayuki,ManasaUpdateIOOPMC and MC alignment[Manasa, Masayuki]
The MC lost lock around 8+hrs ago.
The transmission from PMC was 0.77 this morning,
  
  9190   Thu Oct 3 01:24:31 2013 Jenne, RanaUpdateIOOPMC The PMC transmission was around 0.78 all
day, rather than the usual 0.83ish. 
Rana went out to the PSL table and fixed
 PMCR_1064822387.bmppmc80.png 
  9205   Sun Oct 6 17:05:49 2013 ranaSummaryIOOMC ASC problemsMC unlocked over the weekend and also got
severely mis-aligned. It all started around
midnight on Saturday.
 mcasc.pdf 
  9209   Sun Oct 6 22:52:09 2013 Jenne, RanaUpdateIOOinput beam to PMC aligned againafter  pmcr.png 
  9210   Sun Oct 6 23:43:07 2013 ranaUpdateIOOWFS debugging

    

       
            
  
  9238   Mon Oct 14 17:51:40 2013 JenneUpdateIOOinput beam to PMC drifted again

    

       
            
  
  9256   Mon Oct 21 13:15:52 2013 KojiUpdateIOOPMC alignedPMC aligned. Trans 0.78 -> 0.83   
  9296   Sat Oct 26 21:46:33 2013 RANAUpdateIOOMode Cleaner Tune-UP The
MC had been unlocked for the last 4 hours
and was crying out to me so I gave it some
 MCtrend.pdfMC40days.png 
  9303   Mon Oct 28 14:12:48 2013 manasaUpdateIOOMode Cleaner relocked

    

       
            
 Screenshot-Untitled_Window-3.png 
  9306   Mon Oct 28 21:33:55 2013 RANAUpdateIOOMode Cleaner Tune-UP 
8 day minute trend of some of the
IMC alignment signals.
 Untitled.png 
  9315   Wed Oct 30 01:53:52 2013 JenneUpdateIOOMode Cleaner relockedThe MC (mostly MC2) decided a few minutes
ago to move, so I put the SUSPIT and SUSYAW
numbers back where they were, and the tweaked
  
  9320   Wed Oct 30 16:46:17 2013 manasaUpdateIOOMC alignedMC has not been very happy since last night. 
What I did to fix this:
1. Disabled autolocker and WFS and
  
  9322   Thu Oct 31 15:34:28 2013 manasaUpdateIOOMC not happy since yesterday

    

       
            
 MC_drift.png 
  9323   Thu Oct 31 20:05:48 2013 RANAUpdateIOOMode Cleaner Tune-UP

    

       
            
 drifty.png 
  9324   Thu Oct 31 21:22:00 2013 rana, kojiSummaryIOOmodulation beat note in MC servoI hooked up the 4395 to the MC servo board
test out (TP2A) and looked at the spectrum
using our new SPAG4395.py script. We noticed
 13031.png13031_200.png13031_200b.png 
  9325   Fri Nov 1 09:45:32 2013 SteveUpdateIOObeam dumps to be find

    

       
            
 razor_beam_dumps.jpg 
  9334   Mon Nov 4 11:37:12 2013 SteveUpdateIOOPSL output shutter installed 
 The PSL shutter is reinstalled.The
base plate is delrin for isolation and the
 Shutterisback.jpg 
  9336   Mon Nov 4 12:59:43 2013 JenneUpdateIOOMC alignment not so good after PSL output shutter installed

    

       
            
 MCspots_4Nov2013.png 
  9342   Tue Nov 5 00:39:43 2013 manasaUpdateIOOIFO alignment tuningInformation acknowledged from Steve:
The last steering mirror mount for
IR on the PSL was swapped for a more robust
 MC_spot.png 
  9343   Tue Nov 5 08:44:21 2013 SteveUpdateIOOafter last steering mirror mount swap The IOO Angle and IOO Position qpds 
were recentered after this entry.
 Suggested corrections in elog
 after_Shutter_SMm_installed.pngafterlastSMmountswap.jpg 
  9352   Wed Nov 6 08:33:53 2013 SteveUpdateIOOPoiting changes of PSL

    

       
            
 1dayTRENDofPOITING.png20dayTRENDioo.png 