40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 17 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  17045   Thu Jul 28 20:16:26 2022 AnchalUpdateBHDShaking test for LO beam AS beam to BHD DCPDsSome insights from the inside vacuum situation:


The beam is an incident
near normal on PR2 close to the center of
  
  17049   Sat Jul 30 10:38:12 2022 AnchalUpdatePSLFSSSlow/MCAutolocker issue (docker)The FSSSlow script was not properly documented
and it was not working, so I had to use one
that I knew worked from CTN. This scripts
  
  17057   Thu Aug 4 11:28:22 2022 AnchalUpdatePSLFSSSlow/MCAutolocker issue (docker)Added C1:IOO-MC_LOCK
to ALConfigMC.yml which solved the isse
with FSS Slow. We should tune the FSS Slow
  
  17080   Mon Aug 15 15:43:49 2022 AnchalUpdateGeneralComplete power shutdown and startup documentationAll steps taken have been recorded here:
https://wiki-40m.ligo.caltech.edu/Complete_power_shutdown_2022_08
  
  17081   Mon Aug 15 18:06:07 2022 AnchalUpdateGeneralc1vac issues, 1 pressure gauge died[Anchal, Paco, Tega]


Disk full issue:

c1vac
was showing /var disk to be full. We moved
  
  17092   Fri Aug 19 14:46:32 2022 AnchalUpdateSUSOpen loop transfer function measurements for local damping loops of BHD optics[Anchal, Tega]

As a first step to characterize
all the local damping loops, we ran an open
  
  17096   Sat Aug 20 20:26:10 2022 AnchalUpdateSUSOpen loop transfer function measurements for local damping loops of Core opticsI made measurements of old optics OLTF
today. I have reduced the file sizes of the
plots and data now. It is interesting that
 ALL_CORE_SUS_OLTF_2022-08-20-merged.pdf 
  17129   Fri Sep 2 15:30:10 2022 AnchalUpdateGeneralAlong the X arm part 1[Anchal, Radhika]

Attachment 2: The custom
cables which were part of the intermediate
  
  17130   Fri Sep 2 15:35:19 2022 AnchalUpdateGeneralAlong the Y arm part 2[Anchal, Radhika]

The cables in USPS open box were
important cables that are part of the new
  
  17131   Fri Sep 2 15:40:25 2022 AnchalSummaryALSDFD cable measurements[Anchal, Yehonathan]

I laid down another temporary cable
from Xend to 1Y2 (LSC rack) for also measuring
 ICableOpenEnd_2022-09-02_3_08_34_PM.pngICableShortedEnd_2022-09-02_3_04_43_PM.pngQCableOpenEnd_2022-09-02_3_09_49_PM.pngQCableShortedEnd_2022-09-02_3_00_55_PM.pngDFD_Delay_Measurement.pdf 
  17134   Wed Sep 7 14:32:15 2022 AnchalUpdateSUSUpdated SD coil gain to keep all coil actuation signals digitally same magnitudeThe coil driver actuation strength for
face coils was increased by 13 times in LO1,
LO2, SR2, AS1, AS4, PR2, and PR3.
  
  17140   Thu Sep 15 11:13:32 2022 AnchalSummaryASSYARM and XARM ASS restoredWith limited proof of working for a few
times (but robustly), I'm happy to report
that ASS on YARM and XARM is working now.
  
  17147   Tue Sep 20 18:18:07 2022 AnchalSummarySUSETMX, ETMY damping loop gain tuning[Paco, Anchal]

We performed local damping loop
tuning for ETMs today to ensure all damping
  
  17152   Thu Sep 22 19:51:58 2022 AnchalUpdateBHDBH55 LSC Model Updates - part III updated follwoing in teh rtcds models
and medm screens:


c1lsc

Added
  
  17157   Fri Sep 23 19:04:12 2022 AnchalUpdateBHDBH55 LSC Model Updates - part IIIBH55

I further
updated LSC model today with following changes:


BH55 whitening switch binary
  
  17165   Thu Sep 29 18:01:14 2022 AnchalUpdateBHDBH55 LSC Model Updates - part IVMore model changes

c1lsc:


BH55_I and BH55_Q are now
being read at ADC_0_14 and ADC_0_15. The
  
  17166   Fri Sep 30 18:30:12 2022 AnchalUpdateASSModel ChangesI updated c1ass model today to use PR2
PR3 instead of TT1 TT2 for YARM ASS. This
required changes in c1su2 too. I have split
  
  17168   Sat Oct 1 13:09:49 2022 AnchalUpdateIMCWFS turned onI turned on WFS on IMC at:

PDT: 2022-10-01 13:09:18.378404
PDT
  
  17174   Thu Oct 6 11:12:14 2022 AnchalUpdateBHDBH55 RFPD installation complete[Yuta, Paco, Anchal]

BH55 RFPD installation was still
not complete until yesterday because of a
  
  17175   Thu Oct 6 12:02:21 2022 AnchalUpdateCDSCDS Upgrade Plan[Chris, Anchal]

Chris and I discussed our plan
for CDS upgrade which amounts to moving new
  
  17176   Thu Oct 6 18:50:57 2022 AnchalSummaryBHDBH55 meas diff angle estimation and LO phase lock attempts[Yuta, Paco, Anchal]

BH55 meas diff

We
estimated meas diff angle for BH55 today
  
  17178   Fri Oct 7 22:45:15 2022 AnchalUpdateCDSCDS Upgrade Status Update[Chris, Anchal, JC, Paco, Yuta]




  
  17184   Tue Oct 11 16:52:42 2022 AnchalUpdateIOORenaming WFS channels to match LIGO site conventions[Tega, Anchal]

c1mcs and c1ioo models have been
updated to add new acquisition of data.
  
  17195   Mon Oct 17 20:04:16 2022 AnchalUpdateBHDBH55 RF output amplified[Radhika, Anchal]

We have added an RF amplifier to
the output of BH55. See the MICH signal on
 BH55_RF_Amp_Working.pngrn_image_picker_lib_temp_1b072d08-3780-4b1d-9325-5795ed099d3d.jpgrn_image_picker_lib_temp_9d7ed3c0-7ff0-4ff7-9349-0211be397dc5.jpgrn_image_picker_lib_temp_05da14e1-eae0-4a84-8761-1c42b122cb1b.jpg 
  17198   Tue Oct 18 20:43:38 2022 AnchalUpdateOptimal ControlIMC open loop noise monitorWFS loops were running for past 2 hours
when I made the overall gain slider zero
at:
  
  17199   Wed Oct 19 09:48:49 2022 AnchalUpdateOptimal ControlIMC open loop noise monitorTurning WFS loops back on at:

PDT: 2022-10-19 09:48:16.956979
PDT
  
  17203   Fri Oct 21 10:37:36 2022 AnchalSummaryBHDBH55 phase locking effortsAfter the amplifier was modified with a
capacitor, we continued trying to approach
locking LO phase to in quadrature with AS
  
  17218   Tue Nov 1 15:41:18 2022 AnchalUpdateSUSF2A filter design and trial on MC1Following discussion in this elog thread
(40/6004),
I used the design of F2A (force to angle(pitch))
 20221101_MC1_F2A_Filters.pdfETMY_F2A_Filters_Already_There.pdfMC1_F2A_Test.png 
  17219   Tue Nov 1 17:17:27 2022 AnchalUpdateSUSModified F2A filter design and trial on MC1After a quick discussion with Yuta, we
figured that the introduction of a finite
Q that Peter Fritschel does in this DCC doc
 20221101_MC1_F2A_Filters_Q_On_Both.pdf 
  17220   Tue Nov 1 17:59:23 2022 AnchalUpdateSUSAdded F2A filters on MC1, MC2, and MC3I've cleared all old attempts on F2A
filters on MC1, MC2, and MC3, and added the
default F2A filter described in the last
  
  17222   Thu Nov 3 14:00:29 2022 AnchalUpdateSUSMC1 coil strengths balancedI balanced the face coil strengths of MC1
using following steps:


At
  
  17223   Thu Nov 3 14:42:57 2022 AnchalUpdateSUSMC2 coil strengths balancedBalanced MC2 coil strengths using the
same method.

Final coil strengths found:
  
  17225   Thu Nov 3 16:22:11 2022 AnchalUpdateSUSMC3 coil strengths balancedBalanced MC3 coil strengths using the
same method.

Final coil strengths found:
  
  17227   Thu Nov 3 17:36:00 2022 AnchalUpdateSUSF2A filters on MC1, MC2, and MC3 set to test at 1 am


  
  17228   Thu Nov 3 20:07:01 2022 AnchalSummaryBHDAS1 coil balancing required[Anchal, Koji]

The LO phase lock that was achieved
lasts for a short time because as soon as
  
  17231   Mon Nov 7 11:24:05 2022 AnchalUpdateSUSF2A filters on MC1, MC2, and MC3 set to test at 1 amThis test was not successfull as IMC lost
lock during the f2A filter trial. However,
we do have 1 hour off data when all f2A filters
 MC3_f2a_failure_analysis.pdfMC3_f2a_Failure_Event.pngMC3_f2aQ3_filters.pdf 
  17232   Mon Nov 7 12:02:15 2022 AnchalUpdateSUSIMC test with PSL shutter closed.Following configurations were kept today
morning:

  
  17234   Mon Nov 7 14:38:59 2022 AnchalUpdateSUSMC3 coil strengths rebalancedI checked again today by sending excitation
at POS and reading back from C1:IOO-MC_TRANS_P
and C1:IOO-MC_TRANS_Y. I found that there
  
  17235   Mon Nov 7 16:14:43 2022 AnchalUpdateSUSF2A filter with Q=1, 0.3 stable with MC3I tired running for a few hours F2A filter
with Q=1 and for maybe 30 min Q=0.3 on MC3
today and that keeps the suspension stable.
  
  17236   Mon Nov 7 17:10:41 2022 AnchalSummaryBHDQPD installation seems like lost causeThe new QPD installation is turning out
to be much more hard than it originally seemed.
After finsing the cable, QPD and interface
  
  17237   Mon Nov 7 19:53:12 2022 AnchalUpdateSUSMC2 OSEMs calibrated using MC_FMC2 OSEM outputs were calibrated today
using MC_F to get the output values in microns.
This was done using
  
  17238   Mon Nov 7 20:00:37 2022 AnchalUpdateSUSMC1 OSEMs output is weirdFollowing up, I tried to do this exercise
with MC1 and MC3. While MC3 shows expected
minute corrections to the previous value,
 MC1_MC_F_OSEM_TF.pdfMC3_MC_F_OSEM_TF.pdf 
  17241   Tue Nov 8 10:23:42 2022 AnchalUpdateSUSMC3 damping loop step responsesI tuned MC3 local damping gains by looking
at step responses in the DOF bassis. The
same procedure was followed as described
 MC3_Step_Response_Test_2022-11-08_09-48.pdfMC3_Step_Response_Test_2022-11-08_10-19.pdf 
  17242   Tue Nov 8 10:35:26 2022 AnchalUpdateSUSIMC F2A testThis time the test was succesful but I
have reverted MC3 f2a filters back to with
Q=3, 7, and 10. The inital part of the test
 IMC_f2a_test_results.pdf 
  17245   Tue Nov 8 18:12:01 2022 AnchalUpdateSUSMC2 OSEMs calibrated using MC_FI reran this measurement at low frequency
0.1016 Hz. Following were the cts2um gain
changes:
  
  17246   Tue Nov 8 19:39:34 2022 AnchalUpdateSUSMC3 OSEMs calibrated using MC_FI did the same measurement for MC3 with
one difference that OSEMs report 
  
  17249   Wed Nov 9 11:07:16 2022 AnchalUpdateSUSIMC testFollowing configurations were kept today
morning:

  
  17251   Wed Nov 9 20:01:38 2022 AnchalUpdateSUSMC1 OSEMs output is weirdI took a coil to OSEM transfer function
for MC1 osems  (LL, UR) today and again
the slope of the transfer function was -1.4
 MC1_COIL_to_OSEM_TF.pdfMC3_COIL_to_OSEM_TF.pdfMC1_UR_OSEM_TF.pdf 
  17252   Wed Nov 9 20:29:20 2022 AnchalUpdateSUSMC2 and MC3 set to undergo free swing test tonightI have set a free swing test for MC2 and
MC3 to trigger at 1 am tonight. The test
should last for about 4.5 hrs upto 5:30 am.
  
  17256   Fri Nov 11 11:29:11 2022 AnchalUpdateSUSMC1 OSEMs output is weirdLate elog; original time Thursday, Nov
10 16:00 2022

MC1 is using a new satellite
 MC1_UR_WhtnBrd_TF.png 
ELOG V3.1.3-