  4106   Tue Jan 4 15:12:33 2011 SureshUpdateIOOMC Trans Mon QPD gain decreased by 10 Decreased
the gain of MC-Trans-Mon QPD ckt
The
  
  4107   Tue Jan 4 18:37:18 2011 JenneUpdateIOOMCWFS alignedI undid Yuta's
temporary setup, and put beam back on both
  
  4108   Tue Jan 4 21:21:57 2011 kiwamuUpdateIOOPZTs are connected to c1iscauxI connected
PZT1 and PZT2 to a slow front end machine
 Screenshot20110104.png 
  4110   Wed Jan 5 03:06:02 2011 kiwamuUpdateIOObeam spots on MC mirrorsI checked
the spot positions on MC1 and MC3 by running
  
  4113   Wed Jan 5 16:11:17 2011 kiwamuSummaryIOOtemporary PZT connection   PZTconnection.png 
  4120   Thu Jan 6 00:06:01 2011 JenneUpdateIOOMagical absorbing PZT mirror[Kiwamu, Jenne]
We have a measely 465mW going into
  
  4122   Fri Jan 7 00:14:36 2011 kiwamuUpdateIOOEOM triple resonant box is working I
checked the triple resonant box for the broadband
  
  4138   Tue Jan 11 18:41:43 2011 JenneUpdateIOOPut MC PZT offset onto MC board, instead of on awkward cart[Larisa and Jenne]
We wanted to get rid of the awkward
cart that was sitting behind the 1Y1 rack. 
 D040180-B.pdf 
  4140   Wed Jan 12 01:38:52 2011 KojiUpdateIOOPut MC PZT offset onto MC board, instead of on awkward cartI can not think of any reason that the
input impedance of 13kOhm between the pos/neg
inputs produces such a big change at the
  
  4145   Wed Jan 12 22:19:54 2011 KojiUpdateIOOMC flakiness solved[Koji Suresh Kiwamu]
Suresh modified the MC board to have
+5V offset at the output. (To be reported
  
  4147   Wed Jan 12 22:39:16 2011 SureshUpdateIOOPut MC PZT offset onto MC board, instead of on awkward cart


   
        
            
 P1120508.JPGP1120509.JPGD040180-B_with_5V_offset.pdf 
  4148   Thu Jan 13 03:00:01 2011 JenneUpdateIOOWFS shenanigansMy goal
this afternoon was to
 D990249-B-1_MCWFS_schematic.pdf 
  4149   Thu Jan 13 12:56:57 2011 ranaUpdateIOOWFS shenanigansActually, I just found out that there are
different flavors of 'YAG-444'. 
There's a YAG-444AH and also a YAG-444-4AH.
 PerkinElmerQPDs.pdf 
  4222   Fri Jan 28 13:07:31 2011 JenneUpdateIOOBeam is back on the WFSThe MC WFS have had beam dumps in front
of them for the past ~2 weeks, until I could
find the appropriate optic to put in the
  
  4224   Fri Jan 28 18:19:21 2011 JenneUpdateIOOWFS2 has some kind of oil on itMystery solved!
I removed WFS2 from the AP table
(after placing markers so I can put it back
 Oily_WFS2.jpg 
  4289   Mon Feb 14 15:59:49 2011 JenneUpdateIOOWFS quantum efficiency as a function of angle[Larisa and Jenne]
A few weeks ago (on the 28th of January)
I had tried to measure the quantum efficiency
  
  4303   Tue Feb 15 17:48:22 2011 JenneUpdateIOOMode Cleaner resonating again[Valera, Jenne]
After Steve and Valera switched out
the PMC, the Mode Cleaner resonance needed
  
  4304   Tue Feb 15 21:45:08 2011 ranaUpdateIOOThe MC TRANS StoryI forgot
to elog that last night I touched
up the MC2_TRANS QPD setup
 a.png 
  4305   Wed Feb 16 01:03:59 2011 JenneUpdateIOOMC alignment workSo.... Kiwamu and I were concerned (still
a little concerned) that ETMY is not damping
as nicely as it should be.  (It's fine,
  
  4307   Wed Feb 16 10:35:40 2011 Larisa ThorneUpdateIOOWFS quantum efficiency as a function of angle Here is the followup on Jenne's February
14th, 2011 update on the quantum efficiency
measurements of WFS2.
 QEcalcs.pdf 
  4316   Thu Feb 17 14:52:27 2011 JenneUpdateIOOMC alignment workI worked a little bit more on optimizing
the mode matching to the MC, but it's still
not great.  I've only gotten a visibility
  
  4331   Sun Feb 20 21:22:33 2011 rana, kiwamu, valeraConfigurationIOOMC Servo ChangeFor some reason, Kiwamu   
  4333   Mon Feb 21 17:29:57 2011 ranaSummaryIOOMyterious data loss: FB needs investigationLooks like there was a mysterious loss
of data overnight; since there's nothing
in the elog I assume that its some kind of
 Untitled.png 
  4340   Tue Feb 22 23:40:31 2011 KojiUpdateIOOMC mode mach improvementAs per Kiwamu's request I made a light
touch to the input steering and the mode
matching lens.
 IOO_MMT_110222.png 
  4343   Wed Feb 23 10:37:02 2011 josephbSummaryIOOMyterious data loss: FB needs investigationFriday: 
In addition to the other fixes, Alex
rebuilt the daqd process.  I failed to
  
  4360   Sat Feb 26 00:25:38 2011 KojiUpdateIOOMC servo improvement[Rana / Koji]
The MC servo loop has been investigated
as the MC servo was not an ideal state.
 fss_servo.pngmc_servo.png 
  4366   Wed Mar 2 04:01:51 2011 KojiUpdateIOOMC servo improvement[Koji / Rana]
- Since the MC servo had UGF up to
~20kHz and huge servo bump at 50kHz, we needed
 IMG_3904.jpgMC_OLTF.pdf 
  4455   Tue Mar 29 00:00:55 2011 KojiUpdateIOOFixing MC/Freq Divider BoxThis is the log of the work on Wednesday
23rd.
1. Power Supply of the freq divider
  
  4504   Fri Apr 8 19:43:03 2011 kiwamuSummaryIOORF combiner eases impedance mismatchingAn RF combiner should  modulationBox.png 
  4505   Fri Apr 8 20:43:46 2011 kiwamuSummaryIOORF combiner + resonant box : impedance and reflection coefficient The
input impedance of the resonant box was measured
when an RF combiner was attached to the box.
 imp_refl.png 
  4517   Tue Apr 12 18:15:07 2011 kiwamuSummaryIOORF combiner is more like attenuator 
I realized
 reflection_test.png 
  4562   Sun Apr 24 21:37:40 2011 kiwamuUpdateIOOreview of triple resonant EOM : model looks fineTo design a new resonant EOM box I started
reviewing the prototype that I've built.
 As a part of reviewing I checked
 Input_impedance.pngEOMcircuitmodel.png 
  4582   Thu Apr 28 15:31:36 2011 kiwamuUpdateIOOMC PDH lock : readjustment of demodulation phaseSince Suresh has installed the RF source
box and changed the cable configuration somewhat,
 
 DSC_2975_ss.jpg 
  4620   Tue May 3 18:46:06 2011 ranaUpdateIOOMC Locking not workingI found that the MC autolocker was OFF.
Kiwamu says he turned it off because its
slow. Suresh says that he has some feelings
 Untitled.pngUntitled.png 
  4621   Wed May 4 11:48:01 2011 SureshUpdateIOOMC Locking not working[Valera, Suresh]
The first time I noticed that the
MC was not locking was after I had finished
  
  4653   Fri May 6 15:42:55 2011 valeraMetaphysicsIOOInput mode cleaner length and 11 MHz modulation frequency After Kiwamu set the REFL11 phases
in the PRMI configuration (maximized PRM->REFL11I
reesponse) I tried to measure the MC length
  
  4659   Sat May 7 18:08:54 2011 valeraUpdateIOOMC beam spot centering scriptI tried to run the scripts/senseMCdecentering
to check the centering of the MC beam spots
on the mirrors. The script (csh) produces
 mcditherlines2.pdf 
  4660   Sun May 8 16:32:52 2011 valeraUpdateIOOMC beam spot centering Kiwamu told me that the CDS matrix
notation has changed and the 40m front end
code has changed since February. I changed
  
  4661   Sun May 8 17:29:01 2011 ranaUpdateIOOMC beam spot centeringIt seems like the best option would be
to make the MCASS just adjust the SUS biases
and center the beams on the suspended optics.
  
  4674   Tue May 10 00:44:52 2011 valeraUpdateIOOMC2 centeringKiwamu, Koji, Valera
We centered the beam on MC2 in pitch
by moving the MC1,2,3 in the following combination
 mc2centering.pdf 
  4692   Wed May 11 17:20:24 2011 kiwamuConfigurationIOOloop diabled on PZT2[Valera / Kiwamu]
 
  
  4699   Thu May 12 05:25:26 2011 kiwamuUpdateIOOIP_POS disconnectedA
cable for IP_POS has been disconnected at
the LSC rack, 1Y2. Due to it currently no
  
  4700   Thu May 12 08:54:11 2011 steveUpdateIOOIP_POS cable found

    

       
            
  
  4704   Thu May 12 18:21:19 2011 kiwamuUpdateIOOwelcome back IP_POSIP_POS
is back.  
  
  4720   Sun May 15 14:01:56 2011 kiwamuUpdateIOOwiring diagram for IP-POSHere is a wiring diagram which shows how
IP-POS (new official name is IB_POS)
is connected.
 ip_pos.png 
  4725   Mon May 16 11:14:36 2011 ranaUpdateIOOwiring diagram for IP-POSJust FYI, the 3113 is a 12-bit ADC, so
we won't get very good resolution out of
these. We should get one of those purple
  
  4806   Fri Jun 10 18:49:40 2011 kiwamuUpdateIOOIntensity Noise after the MCLast
night the relative intensity noise (RIN)
of the beam after MC was measured.
 RIN_afterMC.png 
  4819   Wed Jun 15 00:49:34 2011 SureshUpdateIOOWFS2 has been fixed. 
The WFS2 sensor head had a damaged
Quadrant PIN diode (YAG-444-4A).  This
 WFS_QE_measurement.pngSensorsBrochure-p12.pdfP6150121.JPGP6150124.JPG 
  4860   Wed Jun 22 18:51:47 2011 SureshUpdateIOOWFS2 RF responseI have shifted the Jenne laser back to
the small table where we do RF PD characterisation
(RFPD table).  I found several 25pin
  
  4885   Sun Jun 26 16:02:12 2011 kiwamuUpdateIOOFriday MC activity[Rana / Kiwamu]
 Last Friday we did several
things for MC :
  
ELOG V3.1.3-