  8730   Wed Jun 19 23:50:44 2013 JenneUpdateLSCPRCL locking againThis is a mid-evening update, so I don't
forget all the stuff I've already done.
Aligned PRMI, no nice flashes on
  
  8729   Wed Jun 19 22:38:15 2013 JenneUpdateComputer Scripts / ProgramsLSC normalization sqrt_mon channels added to conlog 
 Something has happened that
all of the C1:LSC-dof_NORM_SQRT_ENABLEs are
  
  8728   Wed Jun 19 22:02:03 2013 JenneUpdateASCNew POP path - ready to tryI put the POPDC cable back to the DC output
of the bias tee that is the first thing at
the LSC rack that the POP110 PD sees. 
  
  8727   Wed Jun 19 18:24:14 2013 JenneUpdateCDSProto-ASC implemented in ASS modelI have implemented a proto-ASC in the ASS
model.  
In an ASC block within the ASS model,
  
  8726   Wed Jun 19 16:47:34 2013 JamieConfigurationComputer Scripts / Programsconlog startup fixed, and restarted

    

       
            
  
  8725   Wed Jun 19 16:04:56 2013 JamieConfigurationComputer Scripts / Programsconlog startup fixed, and restartedI cleaned up a bunch of conlog
stuff to make it all a little more sane and
simple.  I also fixed the messy startup
  
  8724   Wed Jun 19 15:07:20 2013 ranaUpdateIOOWFS debuggingTrying to figure out what's wrong with
the MC WFS:
1) The symptom seems to be that the
  
  8723   Wed Jun 19 04:56:07 2013 KojiUpdateASCmodel name ASS -> ASC ???Sounds good. 
Or we just stuff any angle control
things in to Angular Stabilization System
  
  8722   Wed Jun 19 02:46:19 2013 JenneUpdateCDSConnected ADC channels from IOO model to ASS modelFollowing Jamie's table in elog
8654, I have connected up the channels
0, 1 and 2 from ADC0 on the IOO computer
  
  8721   Wed Jun 19 01:45:49 2013 ManasaUpdateGreen LockingBeat frequency sweep for 3FSRMeasurements:
1. Calibrating offset :
 findIR.pngfindIR1.png 
  8720   Wed Jun 19 01:12:42 2013 JenneUpdateASCmodel name ASS -> ASC ???I am proposing a model name change. 
Currently, we have an "ASS" model,
but we do not have an "ASC" model. 
  
  8719   Wed Jun 19 00:46:06 2013 JenneUpdateSUSsave/restore alignment scripts now also work for TTs, fixed a bugI have done a quick update of the IFO_ALIGN
screen's save and restore scripts, so that
we can now also save, restore, and view
  
  8718   Tue Jun 18 18:24:07 2013 ManasaUpdateIOOMC WFS turned OFF[Jenne, Jamie, Manasa]
Jamie was working on the MC guardian
today (I think he will elog about this soon).
  
  8717   Tue Jun 18 10:37:00 2013 SteveSummaryGeneralnew laser pointers  Red-green
laser pointers added to the depleted
stock of 2011
  
  8716   Tue Jun 18 07:22:20 2013 KojiUpdateLSCSensing Matrix vs. Schnupp AsymmetryInteresting.
What's the reason why the PRMI/MICH
ratio gets worse (larger) for 55MHz and 165MHz
  
  8715   Mon Jun 17 23:53:03 2013 AnnalisaUpdateGreen LockingY arm locked on green!!Y
arm locked on green carrier in 00 mode!
It
locked at almost 280 cts, and the transmitted
  
  8714   Mon Jun 17 23:12:19 2013 ManasaUpdateGreen Lockingcan't get IR to resonateWhat I did: 
1. Followed the same procedure to
enable ALS (http://nodus.ligo.caltech.edu:8080/40m/8703)
  
  8713   Mon Jun 17 21:10:25 2013 JenneUpdateLSCSensing Matrix vs. Schnupp AsymmetryThe plots, with a log y axis
PRMI:
 SchnuppLoop_PRMI_REFLdiodes.pngSchnuppLoop_DRMI_REFLdiodes.pngSchnuppLoop_PRFPMI_REFLdiodes.pngSchnuppLoop_DRFPMI_REFLdiodes.png 
  8712   Mon Jun 17 17:51:43 2013 JenneUpdateLSCPOP QPD cables laidPower not on to the POP QPD yet though. 
Also, still need to reconnect POPDC.
  
  8711   Mon Jun 17 16:34:15 2013 JenneUpdateLSCSensing Matrix vs. Schnupp AsymmetryI have made some plots of the sensing matrix
(PRCL / MICH amplitude ratio, and relative
angle) versus Schnupp asymmetry for all the
 10x 
  8710   Fri Jun 14 17:54:11 2013 JenneUpdateASCNew POP path - cabling work

    

       
            
  
  8709   Fri Jun 14 17:15:45 2013 ManasaUpdateGreen Lockingc1als model editedI have edited the daq channels in c1als
model.
Added: DQ channels for the error
  
  8708   Fri Jun 14 07:06:19 2013 KojiSummaryGreen LockingX arm ALSIt's nice that we are now able to scan
the cavity again. We got close to PRMI+one
arm one step further.
  
  8707   Fri Jun 14 03:10:40 2013 JenneUpdateASCNew POP path - PDs in place, need cablingI have placed the lenses and the PDs in
their new positions on the POP path. 
As Koji had pointed out to me in reply to
  
  8706   Fri Jun 14 02:38:07 2013 ranaUpdateLSCNew modeled sensing matrix This is nice - how about figuring
out how to plot the measurement and model
on the same plot? I guess we need to figure
  
  8705   Fri Jun 14 00:32:43 2013 JenneUpdateLSCNew modeled sensing matrixI put in a new version of the modelled
plot.  I figured out a different way
to keep things generic so the same script
 SensMatModel_13June2013_currentPRMIfreq.pngSensMatModel_13June2013_idealPRMIfreq.png 
  8704   Thu Jun 13 23:28:40 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching

    

       
            
  
  8703   Thu Jun 13 22:31:12 2013 ManasaSummaryGreen LockingX arm ALSStabilized ALS
and beat frequency sweep realized.
 IMG_0659.JPGALS_stabilized_13June2013.png 
  8702   Thu Jun 13 16:13:08 2013 nicolasUpdateLSCNew modeled sensing matrixI'd repeat the measurement for REFL11.
The PRC arrow has some big error bar on it,
and maybe the true error is even bigger.
  
  8701   Thu Jun 13 16:01:48 2013 nicolasUpdateGreen LockingY arm locked with green but bad mode matching


   
        
            
  
  8700   Thu Jun 13 15:04:16 2013 JenneUpdateLSCNew modeled sensing matrixUsing all of the latest parameters that
I can find, I have re-modeled the 40m sensing
matrix.  Also, I have it output the
 SensMatMeas_23May2013.pngSensMatModel_13June2013.png 
  8699   Thu Jun 13 10:57:36 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching> > Hmmm.  You seem to be saying that more
light is reflected than is injected. Is this
a units problem? Or was some IR on the power
  
  8698   Thu Jun 13 00:35:23 2013 ManasaUpdateGreen LockingY arm locked with green but bad mode matching> Hmmm.  You seem to be saying that more light
is reflected than is injected. Is this a
units problem? Or was some IR on the power
  
  8697   Wed Jun 12 23:06:33 2013 JenneUpdateGreen LockingY arm locked with green but bad mode matchingHmmm.  You seem to be saying that more light
is reflected than is injected. Is this a
units problem? Or was some IR on the power
  
  8696   Wed Jun 12 22:48:10 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matchingAfter restoring alignment I could see again
strong 00 flashes (about 250-300 counts on
ALS-TRY). So I locked the arm with IR and
  
  8695   Wed Jun 12 01:56:58 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching 
 For the mode matching calculation
I was using the ETMY focal length that I
 waistVaryingLensPos.pdfgreen.JPGModeMatchingY.pdf 
  8694   Tue Jun 11 22:16:56 2013 ManasaSummaryGreen LockingALS for X armI discussed with Yuta about the ALS servo
and phase tracker and found that there was
a lot of information lying around from last
  
  8693   Tue Jun 11 10:00:54 2013 nicolasUpdateGreen LockingY arm locked with green but bad mode matching

    

       
            
  
  8692   Mon Jun 10 21:39:26 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching 
Still no good locking! 
  
  8691   Sat Jun 8 00:24:11 2013 AnnalisaUpdateGreen LockingY arm locked with green but bad mode matching[Annalisa, Nic]
After connecting the PD with the
reflection from the arm  to the PDH
  
  8690   Fri Jun 7 23:44:54 2013 KojiUpdateGeneralProjector - lightbulb replacedhttp://nodus.ligo.caltech.edu:8080/40m/7885   
  8689   Fri Jun 7 21:33:39 2013 ManasaUpdatePSLPSL green to Y- BEAT PD blockedTo allow Annalisa to work on the Y-green
alignment as I work with the X-green, the
part of the PSL green beam that goes to the
  
  8688   Fri Jun 7 17:12:46 2013 gautamUpdateGeneralProjector - lightbulb replaced

    

       
            
  
  8687   Thu Jun 6 16:33:19 2013 steveUpdatesafetyupdated laser inventory Updated laser inventory and operator
list. They are posted in the 40m wiki and
entry doors of the 40m IFO room.
 ELSOconnected.jpg 
  8686   Thu Jun 6 15:46:10 2013 Max HortonSummaryGeneral Smart UPS 2200 Batteries ReplacedReplaced the batteries successfully in
the control room.  We just had to switch
the clips from the old batteries to the new
  
  8685   Thu Jun 6 09:58:13 2013 SteveUpdateendtable upgradeenclosure to chamber connection 
 Thin
wall connector from McMCarr#55275K25
 thinwallconnector.jpg06061301.PDF 
  8684   Wed Jun 5 20:45:19 2013 gautamUpdateGeneralITMx Oplev Fixed

    

       
            
 ITMx_overview.JPGITMx_clipping_.JPG 
  8683   Wed Jun 5 17:37:10 2013 ranaUpdateGeneralfast 2004 qpd

    

       
            
  
  8682   Wed Jun 5 15:55:16 2013 SteveUpdateGeneralProjector - lightbulb ordered

    

       
            
  
  8681   Wed Jun 5 15:48:02 2013 SteveUpdateGeneralfast 2004 qpdThank you Ben Abbott forwarding this information:
 QPD Amplifier
 D990272qpd.jpginterfaceD990692.jpg 