40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 170 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  6710   Tue May 29 21:34:08 2012 JenneUpdateSUSETMY oplev spot size reduced

    

       
            
  
  6711   Tue May 29 21:50:21 2012 JenneUpdateLockingYarm error spectraThe ~16Hz bounce mode of some optic is
showing up in the Yarm error signal. 
MC is kind of 'windy' looking, so
 LSC_POY_11_I_ERR_29May2012.pdf 
  6712   Tue May 29 22:48:37 2012 DenUpdatePEMGuralp noiseI've checked whether the Guralp noise that
we see comes not from seismometer but from
ADC or readout box. I did 2 separate measurements
 split_noises.png 
  6713   Wed May 30 01:35:15 2012 yutaUpdateGreen Lockingaligned Y arm green beam[Jenne, Yuta]
We aligned the Y arm for IR (C1:LSC-TRY_OUT
is now ~ 0.9), and aligned the green beam
  
  6714   Wed May 30 13:24:08 2012 JenneUpdateLockingYarm error spectra

    

       
            
  
  6715   Wed May 30 15:51:22 2012 yutaUpdateIOOMC beam spot oscillation[Koji, Suresh, Jenne, Yuta]
Background:
  We noticed that the beam spots
 specMC3_onoff_localdamping.pdf 
  6716   Wed May 30 18:08:40 2012 JamieUpdateLSCc1lsc: add error point pick-offs, moved ctrl pick-offs after feedforwardI made some modifications to the c1lsc
model in order to extract both the error
and control signals.
 LSCchain.png 
  6717   Wed May 30 18:16:44 2012 JamieUpdateLSCskeleton of new c1cal calibration model created[Jamie, Xavi Siemens, Chris Pankow]
We built the skeleton of a new calibration
model for the LSC degrees of freedom. 
  
  6718   Wed May 30 19:27:38 2012 yutaUpdateIOOMC beam spot oscillation[Koji, Yuta]  
We found that C1:SUS-MC{1,2,3}_TO_COIL_3_4_GAIN
  
  6719   Wed May 30 20:12:15 2012 ranaUpdateIOOMC beam spot oscillationThis is a common occurrence when diagnostic
scripts are written without the ability to
handle exceptions (e.g. ctrl-c, terminal
  
  6721   Wed May 30 22:51:32 2012 DenUpdatePEMguralp isolation boxWhen I've put Guralps inside the isolation
box, the signal from seismometers increased
and was out of AA board range. I've reduced
 lin_box_noise.png 
  6723   Thu May 31 01:20:41 2012 JenneUpdateASSASS filter outputs are non-zero with no inputI was looking a little at ASS, while Yuta
was doing some Green transmitted DC PD work,
and I find that the output of some filters
 ASS_Yarm_crazyOutputs_30May2012.png 
  6724   Thu May 31 01:27:16 2012 yutaUpdateGreen LockingPSL and Y arm green beams aligned[Jenne, Yuta]
We aligned the PSL green optics so
that the PSL green beam and Y arm green beam
  
  6725   Thu May 31 01:36:17 2012 yutaUpdateGreen LockingGREEN_TRX/GREEN_TRY PDsI did the cabling for monitoring DC transmission
of the green beam from the end table.
The two PDs are called GREEN TRX and
  
  6726   Thu May 31 02:27:24 2012 yutaUpdateIOOscript for reliefing MC WFSI wrote a simple script for reliefing MC
WFS servo. The script is located at /opt/rtcds/caltech/c1/scripts/MC/reliefMCWFS.
  
  6727   Thu May 31 04:03:17 2012 yutaUpdateIOOscript for MC beam spot measurementI wrote a wrapping script for measuring
MC beam spot. We had to run several scripts
for the measurement (see elog #6688),
  
  6728   Thu May 31 10:31:19 2012 JamieUpdateIOOMC beam spot oscillation

    

       
            
  
  6729   Thu May 31 11:02:14 2012 steveUpdateLockingETMX 1064 trans camera

    

       
            
  
  6730   Thu May 31 11:38:19 2012 DenUpdatePEMisolation systemI've put Guralps into the Steve's 2 box
isolation system. Noise got better, coherence
between 2 seismometers improved. We still
 lin_box_noise2.pnglin_box_coh.png 
  6731   Thu May 31 16:19:07 2012 yutaUpdateGreen Lockingtemperature setting for PSL doubling crystalI fixed the temperature control of the
oven for the PSL doubling crystal.
The PID settings were not good, and
  
  6732   Thu May 31 16:54:12 2012 JenneUpdateGreen LockingLinks to old elogs for green beatnote laser tempsBecause I keep taking a long time to search
for these, since I can't remember the keywords
in the different entries, here are the links:
  
  6734   Thu May 31 22:13:08 2012 JamieUpdateCDSc1lsc: added remaining SHMEM senders for ERR and CTRL, c1oaf model updated appropriatelyAll the ERR and CTRL outputs in c1lsc now
go to SHMEM senders.  I renamed the
the CTRL output SHMEM senders to be more
 lsc-shmem-out.png 
  6735   Thu May 31 23:53:00 2012 JenneUpdateLSCLSC trigger updateI modified the lsc model (after Jamie finished)
to use a new triggering scheme.  It
HAS NOT yet been compiled and tested, since
  
  6736   Fri Jun 1 02:13:00 2012 JenneUpdateGreen LockingAttempt at Ygreen beat - failed[Yuta, Jenne]
We tried to find the Ygreen beat
note, with no success yet.  We calculate
  
  6737   Fri Jun 1 02:33:40 2012 JenneUpdateComputersc1sus and c1iscex - bad fb connectionsSomething bad happened to c1sus and c1iscex
~20 min ago.  They both have "0x2bad"
's.  I restarted the daqd on the framebuilder,
  
  6738   Fri Jun 1 08:01:46 2012 steveUpdateComputersc1sus and c1iscex are down

    

       
            
 compdown.png 
  6739   Fri Jun 1 08:17:47 2012 steveUpdateIOOPMC trends

    

       
            
 PMC400d.pngPMC1200d.png 
  6740   Fri Jun 1 09:50:50 2012 JamieUpdateComputersc1sus and c1iscex - bad fb connections

    

       
            
  
  6742   Fri Jun 1 14:40:24 2012 JamieUpdateComputersc1sus and c1iscex - bad fb connections

    

       
            
  
  6743   Fri Jun 1 14:56:08 2012 JamieUpdateSUSOplevs all different, messed upFor some reason the state of the oplevs
is completely different for almost every
suspension.  They have different sets
 oplevs.png 
  6744   Fri Jun 1 18:07:32 2012 steveUpdateSUSOplevs servo values

    

       
            
  
  6745   Fri Jun 1 19:48:54 2012 ranaUpdateSUSOplevs all different, messed up 
 Its a good question, but the
answer is yes. At some level all of the OL
  
  6746   Sat Jun 2 03:19:37 2012 yutaUpdateGreen LockingY green beat note found? - too smallSummary:
  I tried to find Y arm green
beat in order to do the mode scan.
 CIMG1437.JPG 
  6747   Sun Jun 3 01:30:07 2012 DenUpdatePEMsts-2 and guralp in isolation boxWe have 2 sts-2 readout box - pink and
blue. Pink outputs 12 DVC - this a problem
of amplifier. This box has a rectifier (the
 DSC_4315.JPGDSC_4319.JPGlin_box_noise.pngmcl_gur.png 
  6748   Sun Jun 3 23:50:00 2012 DenUpdateCDSbiquad=1From now all models calculate iir filters
using biquad form. I've added biquad=1 to
cdsParameters to all models except c1cal,
  
  6749   Mon Jun 4 17:14:31 2012 JenneUpdateLSCLSC recompiled several times todayAs of now, the regular LSC DoF triggers
work, just as they used to.  There is
a problem with the filter module triggers
  
  6750   Mon Jun 4 23:48:43 2012 jenneUpdateGreen Lockinglowered gainWe're trying to do a yarm measurement....before
I forget, I want to write this down...
I changed the gain of each of the
  
  6751   Tue Jun 5 00:49:28 2012 JenneUpdateGreen LockingNightly update[Yuta, Jenne]
Vaguely chronological order:
Found a beat peak, thought it was
  
  6752   Tue Jun 5 09:32:12 2012 steveUpdateSUSPRM oscillation What not to do:
The PRM oplev servo was left on and
it was driving this oscillation overnight.
 PRMosc.png 
  6753   Tue Jun 5 09:44:14 2012 steveUpdatePSLref cavity ion pump must be pumped

    

       
            
  
  6754   Tue Jun 5 14:17:14 2012 steveUpdatePEMair cond maintenance  
 Air conditioning maintenance
is scheduled for tomorrow from 8 to 11am
  
  6755   Tue Jun 5 14:47:28 2012 JamieUpdateCDSnew c1tst model for testing RCG codeI made a new model, c1tst, that we can
use for debugging the FREQUENT RCG
bugs that we keep encountering.  It's
  
  6757   Tue Jun 5 21:09:40 2012 yutaUpdateComputer Scripts / Programshacked ezca toolsCurrently, ezca tools are flakey and fails
too much.
So, I hacked ezca tools just like
  
  6760   Wed Jun 6 00:32:22 2012 JenneUpdateCDSRFM model is way overloading the cpuWe have too much crap in the rfm model.  CPU time for the rfm model is regularly   
  6761   Wed Jun 6 00:37:11 2012 JenneUpdateComputersmx_stream restarted on iscey, susJust as Yuta and I were sitting down to
look at our beatnote (really the output of
the freq discriminator) on Dataviewer, all
  
  6763   Wed Jun 6 02:28:02 2012 yutaUpdateGreen Lockingtried to see Yarm length change with weak beat note[Jenne, Yuta]

Summary:
 beatycoarseringdown20120605.pngbeatysetup20120605.png 
  6764   Wed Jun 6 09:27:09 2012 steveUpdateSUSPRM damping restored

    

       
            
 PRMwhat.png 
  6765   Wed Jun 6 14:17:56 2012 steveUpdateComputersiMac orderedRana, Steve,
 
  
  6766   Wed Jun 6 14:36:58 2012 steveUpdateSUSETMY oplev work finished

    

       
            
  
  6767   Wed Jun 6 15:16:00 2012 yutaUpdateIOOMC WFS offsets adjustedMC reflection (C1:IOO-MC_RFPD_INMON) got
worse when WFS servos were on. After aligning
MC optics, it will be ~0.5 but if I turned
  
ELOG V3.1.3-