40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 170 of 341  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  3357   Wed Aug 4 11:10:28 2010 nancyUpdateIOOMode Cleaner WFSYesterday, I started twiddling with the
Mode Cleaner at about 2 pm.
  
  3358   Wed Aug 4 12:49:42 2010 nancyUpdateIOOMode Cleaner WFS

    
        
 6x 
  3365   Thu Aug 5 01:29:39 2010 nancyUpdateIOOMode Cleaner WFS 
I calculated the MC1&3 Vs WFS1&2
Output Matrix today from the above measurements
  
  3366   Thu Aug 5 11:48:52 2010 nancyUpdateIOOMode Cleaner WFS

    
        
  
  3367   Thu Aug 5 13:05:53 2010 KojiUpdateIOOMode Cleaner WFSUpon Nancy's request, I checked the status
of the suspensions.
I found that the power strip of the
  
  3372   Fri Aug 6 10:44:55 2010 nancy, kojiUpdateIOOMode Cleaner WFS

    
        
  
  3373   Fri Aug 6 12:22:04 2010 JenneUpdateIOOMC data taking over the weekendNancy has the Mode Cleaner for her work
for the night, and is going to leave the
MC happy, locked, autolocker on, WFS enabled,
  
  3374   Fri Aug 6 12:33:10 2010 KojiUpdateIOOMode Cleaner WFS


   
        
            
  
  3375   Fri Aug 6 12:44:29 2010 KojiUpdateIOOMC data taking over the weekendQuestion:
Do you like to keep the WFS turned
on? 
  
  3386   Mon Aug 9 12:46:24 2010 NancyUpdateIOOMode Cleaner WFS    
  3387   Mon Aug 9 13:32:02 2010 nancyUpdateIOOMode Cleaner ASC E-log entry for
Friday - will attach more plots to this entry
 6x 
  3388   Mon Aug 9 15:54:43 2010 KojiUpdateIOOMode Cleaner ASCThe WFS and QPD servos were working.
That was great.
Everything was fine except for the
  
  3389   Mon Aug 9 21:50:50 2010 nancyUpdateIOOMode Cleaner ASC


   
        
            
  
  3713   Thu Oct 14 01:09:17 2010 yutaUpdateIOOtried to lock MC but failed(Rana, Koji, Kiwamu, Suresh, Yuta)
 
  
  3725   Thu Oct 14 23:33:45 2010 SureshUpdateIOO2W NPRO laser output power versus temperatureSteve
measured an apparent power drop in the 2W
NPRO output from 2.1W to 1.6W(elog entry
 tempscan.pngScan2010.zip 
  3726   Fri Oct 15 00:15:52 2010 KojiUpdateIOO2W NPRO laser output power versus temperatureFrom the plot, you observed the reduction
of the output power only by 1% between 25deg
to 45deg.
  
  3730   Fri Oct 15 21:25:23 2010 SureshUpdateIOO2W NPRO laser output power drop question  The power meter used in the measurements
of elog entries 2822, 3698 and 3709 was the
Ophir PD300-3W.  This power head has
  
  3779   Mon Oct 25 23:10:06 2010 KojiUpdateIOOMC is now flashing[Suresh / Koji]
The MC
  
  3791   Wed Oct 27 02:26:15 2010 kiwamuUpdateIOOMC locked (Rana, Koji, Suresh, Yuta, Thanh, Kiwamu)
 M
  
  3805   Thu Oct 28 03:39:58 2010 yutaUpdateIOOgot very stable MC locking(Rana, Suresh, Jenne, Kiwamu, Kevin,
Yuta)
 C1IOO_MC_SERVO20101028.pngMCrocks!.png 
  3806   Thu Oct 28 04:23:38 2010 ranaUpdateIOOA2L prepTo get the angle to length signal before
the c1ioo processor gets going, we need a
length signal. We can use either the error
  
  3817   Fri Oct 29 04:24:34 2010 KojiUpdateIOOPMC output increased: need attention[Kevin Koji]
- The PBS alignment increased
the transmitted power
  
  3868   Fri Nov 5 14:06:19 2010 yutaUpdateIOOtried to align MC by A2L measurement(Suresh, Kiwamu, Yuta)

Summary:
 A2LmeasurementFigures.png 
  3873   Fri Nov 5 23:05:43 2010 ranaConfigurationIOOioo.db file changed in c1iool0 to get back MC TRANS 
We like to have the MC TRANS channels
so that we can run all of our old scripts
  
  3874   Sat Nov 6 00:49:04 2010 KojiUpdateIOOIMC table work[Suresh, Koji]
- Removed MCT optics in the
  
  3876   Sat Nov 6 07:26:54 2010 yutaSummaryIOOreduced common mode displacement of the beam through MC1 to MC3(Koji, Suresh, Yuta)

Summary:
 A2LMCalign.png 
  3878   Mon Nov 8 10:37:14 2010 KojiUpdateIOOThe 10% pick-off for MCREFL was replaced to a HR mirrorAs MC2 Trans mon QPD is temporary removed
for fixing, we needed a reference for the
MC alignment.
  
  3882   Mon Nov 8 18:30:33 2010 SureshUpdateIOOMC Trans Mon QPD gain increased by 50xIncreased
the transimpedance gain of the MC-Trans-Mon
QPD ckt 
  
  3883   Tue Nov 9 05:40:12 2010 yutaSummaryIOOMC aligning going on(Suresh, Yuta)

Background:
 MCalignNov9.png 
  3884   Wed Nov 10 02:51:35 2010 yutaSummaryIOOlimitation of current MC aligning(Suresh, Yuta)

Summary:
 MCalignNov9.png 
  3885   Wed Nov 10 11:46:19 2010 KojiSummaryIOOlimitation of current MC aligningIt didn't make sense in several points.
1. Is the Faraday aperture really
3mm? The beam has the gaussian radius of
  
  3886   Wed Nov 10 12:21:18 2010 yutaSummaryIOOlimitation of current MC aligning1. We didn't measure the aperture size
last night. We have to check that.
  
  3887   Wed Nov 10 14:28:33 2010 KojiSummaryIOOlimitation of current MC aligning1. Look at the Faraday.
2. Look at the wiki. There is the
optical layout in PNG and PDF.
  
  3888   Wed Nov 10 22:29:42 2010 kiwamuUpdateIOOmisaligned the wideband EOMFor Yuta's
business, I intentionally misaligned the
  
  3892   Thu Nov 11 05:56:04 2010 yutaSummaryIOOsetting up temporary oplev for coil balancing of MCs(Suresh, Yuta)

Background:
 MC2coils.png 
  3903   Fri Nov 12 00:42:11 2010 rana, kojiUpdateIOOMC alignmentWe decided to ignore the computer script
outputs for the beam positions and use instead
the eyeball method to get the beam into the
  
  3905   Fri Nov 12 06:10:24 2010 yutaUpdateIOOMC aligned (without coil balancing)Background:
  Last night, we found that one
of DAC channels are poorly connected, so
 MCalignCALIB.png 
  3923   Mon Nov 15 15:01:51 2010 kiwamuUpdateIOOrealigned the wideband EOMSince we are going to lock the MC today,
I
aligned it back to the default place.
  
  3929   Tue Nov 16 03:33:22 2010 yutaUpdateIOOaligned Faraday, beam reached SM just before PRM(Koji, Yuta)

 MCalignNov16.png 
  3937   Wed Nov 17 02:53:41 2010 yutaUpdateIOOplaced new PRM to BS table(Kiwamu, Yuta)

Background:
  
  3943   Thu Nov 18 00:40:31 2010 yutaUpdateIOOPRM reflected beam reached AP table(Kiwamu, Yuta)

Summary:
  
  3973   Tue Nov 23 10:48:31 2010 KojiUpdateIOOthe plan of the day[Kiwamu/Koji]
- The tanks are open
Plan
  
  3980   Tue Nov 23 22:01:49 2010 kiwamuUpdateIOOimmigration plan for in-vac PZT mirrors  [Suresh, Kiwamu]

 Untitled.png 
  3988   Mon Nov 29 11:51:41 2010 kiwamuUpdateIOOswaped in-vac PZT mirrors This morning
I opened the chambers and started some in-vac
  
  3992   Tue Nov 30 04:22:52 2010 kiwamuUpdateIOOswaped in-vac PZT mirrors As a result
of the vacuum work, now the IR beam is hitting
  
  3996   Tue Nov 30 12:33:27 2010 kiwamuSummaryIOOcabling of in-vac PZT mirrors     
  4044   Sat Dec 11 00:41:55 2010 kiwamuUpdateIOOalignment of IP_ANG is done  [Jenne, Koji and Kiwamu]
 
  
  4056   Wed Dec 15 12:46:18 2010 KojiSummaryIOOFinishing up the vac workWhat else?
v: Edit on Dec 15 10PM
  
  4062   Wed Dec 15 23:10:40 2010 KojiUpdateIOOSRM Oplev / Dark Steering mirrors installedI helped the vacuum installation work in
the evening.
- Three steering mirrors after the
  
  4066   Fri Dec 17 00:30:05 2010 KojiUpdateIOOITMY / SRM / BS / PRM OPLEVs aligned[Steve and Koji]
The
invac OPLEV mirrros were aligned
  
ELOG V3.1.3-