  2123   Tue Oct 20 02:14:29 2009 robUpdateIOOMC2 alignment bias changedthe mode cleaner was having trouble locking
in a 00 mode, needing several tries. 
I changed the MC2 coil biases, and it seems
  
  2124   Tue Oct 20 10:46:18 2009 steveUpdateIOOclipping IP-ANG beam at ETMX chamberInitial pointing beam is clearly clipping
on 2" pick off mirror in  ETMX
vacuum chamber.
 PA200175.JPGPA200177.JPG 
  2132   Thu Oct 22 08:45:58 2009 steveUpdateIOOIP ang & pos recentered

    
        
 pointing1000.jpg 
  2144   Mon Oct 26 18:15:57 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain. 
It's around 60kHz with 29 degs of phase margin.
  
  2168   Mon Nov 2 13:00:55 2009 KojiUpdateIOOPMC aligned, MC WFS alignedThe beam to PMC aligned. The beam to MC
WFS cameras aligned.
PMC Trans increased from 2.73 to 2.75
  
  2172   Tue Nov 3 03:45:04 2009 rob UpdateIOOfrequency noise problem

    
        
 noise.pngspectra.pdf 
  2227   Tue Nov 10 17:01:33 2009 AlbertoConfigurationIOOc1ioovme and c1iool0 rebooted This afternoon, while I was trying to add
the StochMon channels to the frames, I rebooted
the c1ioovme and c1iool0.
  
  2234   Wed Nov 11 09:48:04 2009 steveUpdateIOOwhere is IOO-RFAMPD_DCMON ?RFAMPD_DCMON disappered on Nov 5, 2009  rfampddc.jpg 
  2318   Mon Nov 23 21:36:38 2009 KojiUpdateIOOAligned PMC/RCI aligned the beam goes to PMC. It increased
the MC Trans from 8.25 to 8.30.
I also aligned the beam goes to RC.
 091123_PSL.png 
  2357   Sat Dec 5 17:34:30 2009 robUpdateIOOfrequency noise problemThere's a large broadband increase in the
MC_F spectrum.  I'm not totally sure
it's real--it could be some weird bit-swapping
 mcf.png 
  2359   Sat Dec 5 22:31:52 2009 robUpdateIOOfrequency noise problem

    
        
  
  2406   Sun Dec 13 20:50:45 2009 ranaSummaryIOOMach Zender CalibrationI ramped the MZ PZT (with the loop disabled
on the input switch) to calibrate it. Since
the transmission has been blocked, I used
 Untitled.png 
  2407   Sun Dec 13 23:18:09 2009 ranaSummaryIOODisplacement noise on the PSL tableFor the Laser Gyro, I wondered how much
mechanical noise we might get with a non-suspended
cavity. My guess is that the PMC is better
 mz.pdf 
  2431   Fri Dec 18 15:40:33 2009 KojiUpdateIOOMC2 spot centered / MCT QPD issueThis afternoon I felt like saying hello
to the input mode cleaner. So I decided to
center the spot on MC2.
  
  2435   Sun Dec 20 23:42:44 2009 JenneUpdateIOONew Input Mode Matching TelescopeI've got most of the new Mode Matching
Telescope figured out.  The scripts
and an example result are at: MMT09
  
  2444   Tue Dec 22 11:23:51 2009 kiwamu, SteveUpdateIOOMC relockedIn this morning I found MC unlocked.
Steve restored the watchdogs before
I found that.
  
  2448   Wed Dec 23 16:34:25 2009 KojiUpdateIOOMCT QPD/MC REFL QPD disabledFor a certain investigation of the sum/diff
module for MCT QPD/MC REFL QPD, I removed
it from the system.
  
  2451   Thu Dec 24 19:13:29 2009 KojiUpdateIOOMCT QPD investigationI found that MCT QPD has a dependence of
the total output on the position of the spot.
Since the QPD needs the supply and bias voltages
 D990692.png 
  2473   Mon Jan 4 17:21:30 2010 JenneConfigurationIOOElusive Mode Matching Solution found!I think I have
finally found a Mode Matching solution for
 Awesome_MM_Solution.png 
  2481   Wed Jan 6 03:44:41 2010 KojiConfigurationIOOElusive Mode Matching Solution found!I
am in the way to get a reasonable optical
layout.
  
  2535   Thu Jan 21 10:09:27 2010 KojiSummaryIOOPhotos of the optical tablesI made a wiki page dedicated for the photos
of the optical tables.
The current layouts were uploaded.
  
  2559   Tue Feb 2 13:14:09 2010 KojiHowToIOOAnatomy of New Focus Resonant EOMJoe let me use the resonant EOM for GigE
phase camera for a while.
Then, I immediately started to open
  
  2584   Tue Feb 9 17:51:48 2010 JenneSummaryIOOInput Mode Matching Telescope design is completeThe upgrade's input mode matching telescope
design is complete.  A summary document
is on the MMT
  
  2698   Tue Mar 23 00:31:51 2010 KojiUpdateIOOMC realignedThis is the first touch to the MC mirrors
after the earthquake on 16th.

    I made an aluminum access
 IMG_2346.jpgIMG_2347.jpg 
  2699   Tue Mar 23 09:37:36 2010 steveUpdateIOOvac envelope has to be sealed as antproof for overnight


   
        
            
 pc3.JPGpc4.JPG 
  2700   Tue Mar 23 09:55:20 2010 KojiUpdateIOOvac envelope has to be sealed as antproof for overnightRoger.

  
  2705   Wed Mar 24 02:06:24 2010 KojiUpdateIOOvac envelope has to be sealed as antproof for overnightMatt and Koji:
We closed the light doors of the
chambers.
  
  2827   Wed Apr 21 21:46:53 2010 KojiUpdateIOOMC spot diagnosisZach and Koji
We
measured uncalibrated angle-to-length coupling
  
  2852   Tue Apr 27 22:28:58 2010 ZachUpdateIOOMC alignmentBeginning last week, I have been helping
Koji with some of the IO work that must be
done for the 40m upgrade. The first thing
 MC_misaligned.png 
  2855   Wed Apr 28 12:05:44 2010 ZachUpdateIOOMC alignmentI have worked out the first set of adjustments
to make on the MC mirrors (all angle figures
are in units of the increments on the control
  
  2856   Wed Apr 28 14:15:58 2010 AlbertoUpdateIOOMC alignment 
 That's interesting.
Would it be possible to write about
  
  2858   Wed Apr 28 14:42:55 2010 ZachUpdateIOOMC alignmentSure. I figured I would put up a How-To
if it works. 
  
  2864   Sun May 2 15:28:25 2010 KojiUpdateIOOSpot Positions of MC1/MC3Summary
The spot positions on the MC mirrors
were measured with coil balance gains.
 spot_position.png 
  2880   Wed May 5 01:19:05 2010 KojiUpdateIOOMC spot centering cont"dKoji and Zach
We improved the beam axis rotaion
on the MC. We still have 
 steering.png 
  2884   Thu May 6 01:06:16 2010 KojiUpdateIOOMC spot centering cont'd (Triumph)Zach and Koji,
We
finally aligned the incident beam enough
  
  2899   Sat May 8 02:38:08 2010 KojiSummaryIOOMC incident powerAs per Steve's request I checked the
MC incident power as a function of time.
The output is negative: the lower
 MC_input.png 
  2900   Sat May 8 03:09:15 2010 KojiUpdateIOOSteering around MCAfter the MZ-removal work:
- I found that the input steering
(IM1) was right handed. This was different
  
  2918   Wed May 12 03:56:54 2010 KojiUpdateIOOFaraday alignedZach and Koji
The old small MMT was removed and
wrapped by Al foils.
  
  2928   Thu May 13 23:59:46 2010 ZachSummaryIOOMC table leveled After the recent removal of the old
IMMT and the relocation of the Faraday isolator,
the MC table was tilted a bit (southward
  
  2929   Fri May 14 03:30:45 2010 KojiSummaryIOOMC table leveledThanks Zach.This was a great job.
It was not mentioned but: was the
Faraday clamped down on the table?
  
  2931   Fri May 14 10:33:01 2010 ZachSummaryIOOMC table leveledAh... no, I didn't. That explains why there
were loose dogclamps on the table. I wrapped
them in foil and put them on the clean cart.
  
  2935   Sat May 15 04:13:33 2010 KojiSummaryIOOMC table leveledFixing at the next time is absolutely OK.

  
  2938   Mon May 17 02:10:10 2010 KojiConfigurationIOOHow to lock / align the MCLet
me remind you how to lock and align the IMC
To lock
  
  2941   Mon May 17 19:42:11 2010 JenneUpdateIOOFirst steps toward MC mode measuring[Jenne, Kevin, Steve]
We made some progress toward getting
the MC's beam profile measured.  In
  
  2942   Tue May 18 01:40:56 2010 KojiUpdateIOOFirst steps toward MC mode measuringOK. Don't worry. This is just an initial
confusion which we also had for the suspensions
a while ago.
  
  2945   Tue May 18 12:04:13 2010 robUpdateIOOFirst steps toward MC mode measuring


   
        
            
  
  2949   Tue May 18 16:44:35 2010 KojiUpdateIOOFirst steps toward MC mode measuringHere is the upadted list http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_09/Optics

  
  2950   Tue May 18 23:03:08 2010 JenneUpdateIOONo real progress....[Jenne, Kevin]
No real progress today.  We
opened the chambers and again tried to lock
  
  2952   Wed May 19 16:00:18 2010 JenneUpdateIOOHooray! We locked the MC! (and some other stuff)[Jenne, Kevin]
We opened up the MC chambers again,
and successfully got the MC locked today! 
  
  2954   Wed May 19 22:28:05 2010 KojiUpdateIOOHooray! We locked the MC! (and some other stuff)Good! What was the key?
The MC2 spot looks very high, but
don't believe the TV image. Believe the result
  