40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 168 of 354  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  8760   Wed Jun 26 23:32:15 2013 ManasaUpdateGreen Lockingc1als model editedI have modified the ALS model to now include
PHASE_OUT calibration for both X and Y. MEDM
screen has not been edited to include these
 c1als_mdl.png 
  8761   Thu Jun 27 02:44:33 2013 ranaUpdateGreen Lockingc1als model edited Could be that this is OK, but it
doesn't yet make sense to me. Can you please
explain in words how this manages to apply
  
  8768   Thu Jun 27 17:41:08 2013 AnnalisaUpdateGreen LockingETMY -beat note found! 
 Y
 beat_note.JPG 
  8769   Thu Jun 27 17:49:17 2013 manasaUpdateGreen Lockingc1als model edited

    

       
            
 ALS_PHASEcalib.pngBEATX_FINE.png 
  8789   Tue Jul 2 00:25:14 2013 gautamUpdateGreen LockingUniversal PDH box tuning [Koji, Annalisa, Gautam]
Annalisa noticed that over the weekend
the Y-arm green PDH was locked to a sideband,
 circuit.pdfmodel.pdf 
  8792   Wed Jul 3 01:49:46 2013 AnnalisaUpdateGreen LockingALS servo configuration[Koji, Annalisa, Manasa]
Today we worked on the ALS servo
stabilization for the Y arm.
 ALSALS_calibrated 
  8793   Wed Jul 3 03:06:29 2013 AnnalisaUpdateGreen LockingALS servo configuration 
I realized that I cannot open the
attached plots. I'll fix them tomorrow.
  
  8807   Mon Jul 8 21:46:31 2013 manasaUpdateGreen LockingBeatbox[Koji, Manasa]
I wanted to investigate on the ALS
electronics(in particular the beatbox and
  
  8813   Tue Jul 9 17:03:06 2013 SteveUpdateGreen Lockingfiber layed for Y armAlex, Gautam and Steve,
Single
mode fiber 50m long is layed out into
 fromETMYtowardPSL.jpgfibreETMYtoPSL50m.jpgPSLfiberfromETMY.jpg 
  8817   Wed Jul 10 01:27:44 2013 gautamUpdateGreen LockingY-end Green PDH open-loop transfer function [Annalisa, gautam]
Summary:
We have measured the open-loop transfer
 Green_PDH_measurement.pdfY-end_Green_PDH.pdf 
  8818   Wed Jul 10 02:10:41 2013 manasaUpdateGreen LockingBeatbox gets a makeover

    

       
            
 IMG_0842.JPGIMG_0844.JPGIMG_0845.JPGIMG_0846.JPG 
  8819   Wed Jul 10 02:28:04 2013 AnnalisaUpdateGreen LockingBeat notes lost![Manasa, Jenne, Annalisa]
I was going to find the beat note
to start the cavity scan, but I couldn't.
  
  8820   Wed Jul 10 11:27:02 2013 manasaUpdateGreen LockingX arm beatnote foundI found the beat note for X arm. I did
not change anything this morning (to the
best of my knowledge). Hooking up the spectrum
  
  8821   Wed Jul 10 11:44:02 2013 AnnalisaUpdateGreen LockingY beat note found!I found the beat note for the Y arm. Nothing
was changed with respect to yesterday night,
but the beat is back!
  
  8822   Wed Jul 10 14:49:00 2013 SteveUpdateGreen Locking more fiber protective tubing layed

    

       
            
 fibreETMXprotectedendOnly.jpg 
  8824   Thu Jul 11 00:30:27 2013 manasaUpdateGreen LockingX arm ALS post-beatbox makeoverI ran a series of diagnostics on the X
arm ALS to look at how the beatbox behaves
after the makeover.
 XALS_inloop.pdfALS_outloop.pdf 
  8831   Thu Jul 11 14:38:38 2013 AnnalisaUpdateGreen LockingY arm cavity scanYesterday I did a cavity scan with IR while
holding the Yarm with green.
ALS
 IRlocked_res_mot_0710.pdfArmScanN5.pngCavityScanETMYmis 
  8841   Fri Jul 12 23:13:32 2013 manasaUpdateGreen LockingALS sensor noise[Annalisa, Koji, Manasa]

In order to improve the ALS stability
 X_ALS_0712.pdfY_ALS_0712.pdf 
  8842   Sat Jul 13 03:27:20 2013 AnnalisaUpdateGreen LockingY arm caity scanI started doing a scan of the Y arm cavity
with IR with ALS enabled.
ALS
 PowerSpectrum0712ScanCavityAligned.pdfScanCavityMisPitch.pdfScanCavityMisYaw.pdf 
  8844   Sun Jul 14 18:19:00 2013 AnnalisaUpdateGreen LockingArm cavity scanYesterday evening Nic and me were in the
lab. The Mode Cleaner was unlocked, but after
many attempt we could fix it and we did many
  
  8864   Wed Jul 17 22:49:37 2013 KojiUpdateGreen LockingALS Y whitening filter change[Koji Annalisa]
We did the same mod of the beatbox
for the Y arm too. See 
  
  8865   Wed Jul 17 22:51:50 2013 KojiUpdateGreen LockingALS Y performance with the new whitening filter[Manasa Koji]
Summary: 
The new whitening filters improved
 ALS_Y_130717.pdfALS_Y2_StripTool.png 
  8866   Thu Jul 18 01:10:00 2013 kiwamuUpdateGreen LockingALS Y performance with the new whitening filter 
  
  8878   Fri Jul 19 12:00:12 2013 manasaUpdateGreen LockingALS Y performance with the new whitening filter

    

       
            
  
  8886   Mon Jul 22 03:09:51 2013 AnnalisaUpdateGreen LockingY Arm cavity scanYesterday and today I was in the lab doing
many cavity scan.
First I did many measurement with
 Screenshot-scan3_0722.pdf_-_Adobe_Reader.png 
  8931   Sun Jul 28 20:13:41 2013 AnnalisaUpdateGreen LockingY Phase tracker calibrationI did a calibration measurement for the
Y part of the BeatBox using a Marconi. This
is in order to get a more accurate calibration
 YbeatBox_Calibration.pdf 
  9008   Tue Aug 13 21:09:03 2013 manasaUpdateGreen LockingArms ready for ALSI aligned
both the X and Y end green to the arms.
The transmitted green were aligned
  
  9014   Thu Aug 15 12:30:17 2013 manasaUpdateGreen LockingLost beat notes[Koji, Nic, Manasa]
Update from last night.
Koji and I realigned the green optics
  
  9015   Thu Aug 15 19:05:07 2013 manasaUpdateGreen LockingALS out of loop noiseBeat notes were recovered for both the
arms.
I locked the arms to IR using PDH
 ALS_OutLoop.pdf 
  9025   Mon Aug 19 09:36:32 2013 KojiUpdateGreen LockingXend green aligned[Rana Koji]
This is an elog about the activity
on Friday night.
 ALS_OUTOFLOOP_130816.pdf 
  9031   Mon Aug 19 14:22:36 2013 ranaUpdateGreen LockingXend green aligned    
  9033   Mon Aug 19 16:18:56 2013 manasaUpdateGreen LockingXend green alignedASX scripts for PZT dither have been fixed
appropriately. Script resides in 
  
  9034   Mon Aug 19 17:40:32 2013 SteveUpdateGreen LockingXend green layout corrections Shutter moved, no more clipping.
Pick-off mirror 2" replaced
by 1" one. Laseroptik HR 532nm, incident
 beforeC.jpgnowC.jpgstillMultiple.jpg 
  9035   Mon Aug 19 19:08:35 2013 KojiUpdateGreen LockingXend green layout corrections- An Aluminum mirror instead of 2"
unknown mirror for the pick-off for the rejected
beam from the green faraday isolator (Steve)
  
  9039   Tue Aug 20 10:59:15 2013 SteveUpdateGreen LockingXend green layout corrections

    

       
            
 faraway.jpgcloser.jpg 
  9044   Wed Aug 21 00:18:03 2013 MasayukiSummaryGreen LockingX-arm PDH OLTF measurement[Manasa Masayuki]
Today we measured the openloop transfer
function of the PDH green lock of the x-arm.
 IMG_1226.JPGIMG_1228.JPG 
  9047   Wed Aug 21 19:37:25 2013 MasayukiSummaryGreen LockingX-arm PDH OLTF measurement[Manasa, Masyauki]

Today we measured OLTF of PDH green
 OLTF_PDH_Glock_6_5_2.png 
  9054   Thu Aug 22 20:25:28 2013 MasayukiSummaryGreen LockingY-arm PDH OLTF measurement[Manasa, Masayuki]
We measured the the openloop transfer
function of the PDH green lock of the y-arm.The
 OLTF_PDH_Glock_yarm_7.png 
  9055   Thu Aug 22 21:16:47 2013 ManasaUpdateGreen LockingGTRY normalizedThe Y arm green transmission has been measuring
in counts all along. I modified the gain
in the ALS-TRY filter module to normalise
  
  9056   Thu Aug 22 22:05:36 2013 ranaUpdateGreen LockingGTRY normalizedMeh.
600 counts is too weak.  You should
fix the electronics so that the maximized
  
  9083   Wed Aug 28 11:15:02 2013 SteveUpdateGreen LockingXend green layout corrections

    

       
            
  
  9123   Wed Sep 11 23:34:37 2013 MasayukiSummaryGreen LockingALS locking in both arms[manasa, masayuki]
We locked the XARM and YARM with
using ALS control loop and
 noise.pdf 
  9124   Wed Sep 11 23:43:10 2013 KojiSummaryGreen LockingALS locking in both armsWhat was the beat freq for each arm?
The HF noise level depends on the
frequency of the beat note.
  
  9125   Thu Sep 12 00:07:26 2013 MasayukiSummaryGreen LockingALS locking in both arms

    

       
            
  
  9161   Wed Sep 25 23:15:11 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM lockingI measured some error signal, OLTFs and
responses for FPMI noise estimation. Especially
we are interested in the noise from in-loop
 fpmibd.pdf 
  9162   Wed Sep 25 23:59:29 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM locking 
Measurement
 XARM_OLTF.pdfYARM_OLTF.pdfXARM_ITMXresponse.pngYARM_ITMYresponse.pngfree_running.pdf 
  9163   Thu Sep 26 01:49:28 2013 MasayukiSummaryGreen LockingFPMI noise caused by ARM locking 
 Measurement
 MICH_OLTF.pdfBS-RS55Q.pngETMX-RS55.pngETMY-RS55.pngplot.pdf 
  9170   Fri Sep 27 16:02:23 2013 manasaUpdateGreen LockingY arm ALS phase tracking loop gain changed[Masayuki, Manasa]
While trying to lock the arms using
ALS we found that the locks were not very
 outofloop.pdfPTX_OLTF.pdfYPT_OLTF_after1.pdfYPT_OLTF_before.pdf 
  9171   Fri Sep 27 20:28:10 2013 manasaUpdateGreen LockingALS servo[Masayuki, Manasa]
I. ALS servo loops
After fixing things with the phase
 OLTF.pdfphase_badget_xarm_ALS.pdf 
  9176   Mon Sep 30 17:55:45 2013 manasaUpdateGreen LockingX and Y arm transmission needs to be decoupled[Masayuki, Manasa]
Problem
We wanted to lock both the arms using
 scan2.png 
ELOG V3.1.3-