  11039   Mon Feb 16 15:08:26 2015 JenneUpdateLSCALS fool measured decoupling TFDang it, yes. You're right.  I
should have caught that. 

Since Dcpl and Srefl are both zero
  
  11041   Tue Feb 17 00:24:47 2015 rana, jenneUpdateLSCALS Fool filter updated for more cancellationToday
we measured the TFs again and then updated
the filter in the POY -> ALS FF path so
 ALSfoo_150216.png15.png 
  11042   Tue Feb 17 04:04:32 2015 JenneUpdateLSCALS fool mathI re-did the Mathematica notebook according
to the most current diagram (note to daytime
self: attach .nb file!!!), and found that
 OpenLoopGainComparison_16Feb2015.pngCancellationTFs_DecouplingIsArefl.png 
  11043   Tue Feb 17 16:36:08 2015 JenneUpdateLSCALS fool mathHere is an updated cartoon, with the ALS
sensor explicitly shown as the beatbox times
the closed loop response of the phase tracker
 ALSfool_LoopDiagram_17Feb2015.pngALS_REFL_comboLocking_16Feb2015.nb.zip 
  11044   Tue Feb 17 16:44:04 2015 KojiUpdateLSCDelay line installed againFor tonight's experiment, I re-installed
the delay line cable and changed the attenuation
to 10dB for the 55MHz modulation.
  
  11045   Tue Feb 17 19:49:51 2015 KojiUpdateLSCDelay line un-installed againThe modulation setting was reverted.
Demod phase for REFL11/33/55/165 and
AS55 were reverted to the previous numbers
  
  11046   Wed Feb 18 01:58:51 2015 ericqUpdateLSCALS Fool single arm performance I'm playing around with the lastest
ALS fool feedforward on the Yarm, and I like
what I'm seeing. 
 ALSfool_spectra.pngALSfool_kick.pngALSfool_LoopShapes.pngALSfool_Feb182015.zip 
  11047   Wed Feb 18 17:51:40 2015 ericqUpdateLSCALS Fool impulse responseKoji raised a good question about the step
response I wrote about. Namely, if the UGF
of the ALS servo is around 100Hz, we would
 ALSfool_fasterKick.png 
  11048   Wed Feb 18 19:06:40 2015 KojiUpdateLSCALS Fool impulse response   latex-image-1.png 
  11049   Thu Feb 19 04:09:21 2015 ericqUpdateElectronicsSecond QPD Whitening Switch enabledX end QPD has recieved 0.2+0.4 absorptive
ND filters. Y end QPD got one at 0.6. This
appears to have mitigated the saturations
  
  11050   Thu Feb 19 04:16:45 2015 JenneUpdateLSCALS fool attempt with PRFPMI[Jenne, EricQ]

We tried several times tonight
to engage the Fool path with the PRFPMI. 
 BEATYcrazy_duringCARMdarmLock_18Feb2015.png19Feb.png 
  11051   Thu Feb 19 15:45:43 2015 ericqUpdateCDSBad CDS behaviorAt about 10AM, the C1LSC frontend stopped
reporting any EPICS information. The arms
were locked at the time, and remained so
  
  11052   Thu Feb 19 23:23:52 2015 ChrisUpdateCDSBad CDS behaviorThe frontends have some paths NFS-mounted
from fb. fb is on the ragged edge of being
I/O bound. I'd suggest moving those mounts
  
  11053   Fri Feb 20 12:08:10 2015 ericqUpdateCDSBad CDS behaviorI've been able to get all models running.
Most optics are damped, but I'm having
trouble with the ITMs, BS and PRM. 
  
  11054   Fri Feb 20 12:29:01 2015 ericqUpdateCDSAll optics dampedI noticed some diagnostic bits in the c1sus
IOP complaining about user application timing
and FIFO under/overflow (The second and fourth
  
  11055   Fri Feb 20 14:44:47 2015 ericqUpdateCDSBad CDS behaviorIn an effort to ease the IO load on the
framebuilder, I've cleaned up the DQ
channels being written to disk. The biggest
  
  11056   Fri Feb 20 19:09:48 2015 ericqUpdateASCQPD frontend code unifiedI have changed all of the oplevs and transmon
QPDs to use the common ISC QPD library block,
which differs mainly in its divide by zero
  
  11057   Mon Feb 23 08:06:59 2015 ranaUpdateASCQPD frontend code unifiedMight have to also get the OL screens that
go with this new code to see, but the calibrations
don't go into the matrix, but rather
  
  11058   Mon Feb 23 15:04:10 2015 ZachUpdateGeneralElog restartedThe elog crashed while I was creating
an entry to the Cryo log. I restarted it
with the 
  
  11059   Mon Feb 23 21:57:13 2015 KojiUpdateLSCDelay line installed again (experiment, round 1)Last Wednesday we tried PRMI 3f modulation
cancellation. Under the 3f modulation cancellation,
the PRMI could not be locked
  
  11060   Tue Feb 24 01:57:01 2015 JenneUpdateLSCModelled effect of relative modulation phaseI have used Optickle to model the effect
of changing the phase between the 11MHz and
55MHz EOMs.  Also, I have looked at
 ChangeInAngle_PRCLvsMICH.pngREFL33_MICH_SensMat_vsModulationOrder_vsModulationPhase.pngREFL33_SensMat_vsModulationPhase.pngREFL33_PRCL_nominalVsLoweredGamma.pngREFL33_MICH_nominalVsLoweredGamma.png 
  11061   Tue Feb 24 18:54:26 2015 ericqUpdateASCSingle arm QPD ASC stabilityI've lowered the UGFs for the transmission
QPD servos to ~1-2Hz, and made it just an
integrator. I left the arms locked with the
 trend.png 
  11062   Tue Feb 24 23:39:16 2015 JenneUpdateLSCDelay line re-installed againAbout 5-10 minutes ago I just put in the
modulation cancellation setup according to
the recipe in http://nodus.ligo.caltech.edu:8080/40m/11032
  
  11063   Wed Feb 25 04:21:58 2015 ericqUpdateCDSSome model updatesI changed the suspension library block
to acquire the SUS_[optic]_LSC_OUT channels
at 16k for sensing matrix investigations.
  
  11064   Wed Feb 25 04:59:47 2015 JenneUpdateLSCDelay line re-installed, measurements round 2[Jenne, EricQ, Rana]

We spent this evening measuring
and thinking about our 3f signals, and the
 SensMat_PRMI_24Feb2015.pdf 
  11065   Wed Feb 25 11:01:05 2015 manasaUpdateComputer Scripts / ProgramsNew screen for FOL PID loopCreated a new medm screen C1ALS_FOL_PID.adl for
FOL PID loop control in 
  
  11066   Wed Feb 25 12:16:27 2015 KojiUpdateLSCDelay line re-installed, measurements round 2WHAT?
WHAT? WHAT? It's obviously opposite.

If
the reflectivity of the front mirror is fixed
  
  11067   Wed Feb 25 14:18:28 2015 ranaUpdateLSCDelay line re-installed, measurements round 2The Schnupp asymmetry is definitely not
an important parameter (no need for Koji
to explode). It only serves to give us a
  
  11068   Wed Feb 25 14:35:32 2015 SteveUpdatesafetysafety audit 2015Safety audit went soothly. We thank all
participients.

Correction list:
 safety2015audit.jpg 
  11069   Wed Feb 25 14:51:13 2015 JenneUpdateLSCDelay line un-installed againAnd now I've removed the delay line,
and am in the process of reverting the demod
phases, etc.
  
  11070   Wed Feb 25 20:00:39 2015 JenneUpdateLSCDelay line un-installed again - sensing matrix comparisonsI have measured the sensing matrix for
the PRMI at the REFL photodiodes for both
the nominal configuration and the 33MHz cancellation
  
  11071   Wed Feb 25 23:48:57 2015 ranaUpdateLSCsome thoughts
Comparing just the 2 cases with
locking on 33, it seems that the 55 MHz gain
has changed by 14 dB instead of the 10 dB
  
  11072   Thu Feb 26 00:20:54 2015 ericqUpdateLSCModelled effect of relative modulation phaseI'm working on some more modelling
investigations of this whole situation. The
main thing I wanted to do was to look at
 33budget_canceled.png33budget_nominal.png2015-02-ModPhase.zip 
  11073   Thu Feb 26 01:51:39 2015 ericqUpdateLSCSideband HOMsSo, my previous post suggested that 44*11
products might be the dominating signals
in our "nominal" setup. I suppose
 C1_HOMcurves_PR.pngC1_HOMcurves_Y.pngC1_HOMcurves_X.pngC1_HOMlist.zip 
  11074   Thu Feb 26 01:53:35 2015 KojiUpdateLSCModelled effect of relative modulation phaseOk... This is what I was afraid of, and
it seems true.
i.e. the relation ship of the modulations
  
  11075   Thu Feb 26 10:56:34 2015 manasaUpdateGeneralRunning cables[Steve, Manasa]

We ran power cables and sma cables
for the FOL fiber module from the PSL table
  
  11076   Thu Feb 26 13:17:31 2015 ericqUpdateComputer Scripts / ProgramsFB IO loadOver the past few days, I've occasionally
been peeking at the framebuilder IO
load to see If I could correlate anything
  
  11077   Thu Feb 26 13:55:59 2015 jamieUpdateComputer Scripts / ProgramsFB IO loadWe should use "ionice" to throttle the rsync.
 Use something like "ionice -c 3 rsync ..."
to set the priority such that the rsync process
  
  11079   Thu Feb 26 16:46:37 2015 manasaUpdateGeneralIOO rack power supplyI shutdown the +/-15V and the +/-24V sorensons
on the IOO rack to connect the FOL RF PDs
to the rack power supply.
  
  11080   Thu Feb 26 20:02:46 2015 JenneUpdateLSCre: some thoughtsI have clarified my elog from last night
to indicate that the sensing matrix in the
"33MHz cancellation" configuration
  
  11082   Fri Feb 27 03:48:29 2015 JenneUpdateLSCPRMI locked during CARM scanOne of the things that I looked at tonight
was whether or not I could hold the PRMI
on REFL165 at CARM offset of 0, and it turns
 REFL33Lock.pngREFL165Lock.png 
  11083   Fri Feb 27 10:25:24 2015 steveUpdateCamerasquad picture problemMUX input 7 to ITMXF camera cable was replaced
by temporary cable labeled as 888

The problem remains to be the same
 quadMUX.jpg 
  11084   Fri Feb 27 11:20:49 2015 ericqUpdateComputer Scripts / ProgramsiPython Notebook for LSC Sensing Matrix


  
  11085   Fri Feb 27 14:17:51 2015 SteveUpdatesafetysafety audit 2015Safety glasses were measured and they are
all good. I'd like to measure your personal
glass if it is not on this picture.
 1064Tchecked.jpg 
  11086   Fri Feb 27 21:16:10 2015 JenneUpdateLSCPRMI locked during CARM scanHere are a bunch of PDFs of time series
from last night's CARM sweeps. 
The y-axes are all calibrated (except for
 8x 
  11087   Mon Mar 2 17:02:01 2015 ericqUpdateLSCBS - PRM decouplingUsing PRX, I remeasured the relative actuation
strengths of the BS and PRM to see if the
PRM correction coefficient we're using
  
  11088   Mon Mar 2 18:34:12 2015 JenneUpdateSUSETMX moving during single arm lockThis has been edited several times over
the last several hours, as I try to change
different parameters, to see if they affect
 ETMX_moving.pngETMXmoving_ALSlock.pngStartsMoving_stopsItself_ranASS.png80mHz.pngIndependFromFSStemp.png 
  11090   Tue Mar 3 04:41:45 2015 JenneUpdateLSCTransitioned DARM to AS55Q, some other workBetter elog tomorrow - notes for now:

REFL165 for PRMI has been "a
champ" (quote from Q).  We're
  
  11092   Tue Mar 3 09:42:40 2015 SteveUpdateSUSETMX is driftingThe temperature of the east and south ends 
are normal, they are about the same.

 
 ETMXdrifting.pngETMXvsTemp.png 
  11093   Tue Mar 3 11:38:11 2015 SteveUpdatesafetyprofessional crane inspection 




 450lbs2015.jpg 