  9190   Thu Oct 3 01:24:31 2013 Jenne, RanaUpdateIOOPMC The PMC transmission was around 0.78 all
day, rather than the usual 0.83ish. 
Rana went out to the PSL table and fixed
 PMCR_1064822387.bmppmc80.png 
  12214   Sun Jun 26 15:27:28 2016 ranaFrogsIOOPMC /MC lopcedFound PMC unlocked for many hours so I
relocked it. IMC relocked by itself, but
the input switch seems to be flickering to
  
  12911   Mon Mar 27 20:41:21 2017 rana, gautamUpdatePSLPMC DAQ assay for feed-forward integrationWe are thinking to use the PMC signals
to help us in figuring out the feedback /
feedforward stuff and making it better.
 TEK00000.PNG20170327_194931.jpg20170327_204554.jpg 
  12916   Wed Mar 29 11:41:19 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationThe C1IOO frontend machine that resides
in 1X1/1X2 has 2 ADCs, ADC0 and ADC1. The
latter has 28 out of 32 channels unused at
 C1ALS_PSLnamespace.pngPMCcheckout.pdfD980352-A-40m_151119.pdf 
  12920   Thu Mar 30 18:11:01 2017 ranaUpdatePSLPMC DAQ assay for feed-forward integrationWhat you have drawn looks good to me: the
cut should be between TP3 and pin3 of the
AD620. This should maintain the DC coupled
  
  12926   Mon Apr 3 23:07:09 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationI made some changes to the DAQ path on
the PMC servo board, as per the plan posted
earlier in this thread. Summary of changes:
  
  11900   Wed Dec 23 15:43:02 2015 ranaSummaryPSLPMC FSS IMC RF summing boxThe EOM upstream of the PMC is used as
the phase corrector for the FSS/IMC servo.
It is also used to apply the 35.5 MHz PDH
 PMCFSSsummingBox.png 
  1471   Fri Apr 10 19:09:48 2009 JenneUpdatePSLPMC LO CalibrationI measured the RF LO output level from the
PMC's LO board which goes directly into the
LO input on the PMC Servo board.  This goes
 RFSliderAdjustCalib.pngRFSliderAdjustCalibWithOsc.png 
  1473   Sat Apr 11 00:45:41 2009 YoichiUpdatePSLPMC LO Calibration[quote]
I then changed the RF Output Adjust slider
in increments of 0.5, and measured the peak-to-peak
  
  1475   Sun Apr 12 19:27:20 2009 ranaUpdatePSLPMC LO Calibration[quote]
3.8Vpp is about 16dBm. 
The mixer for the PMC demodulator is level
  
  1478   Mon Apr 13 17:55:37 2009 JenneUpdatePSLPMC LO Mon CalibrationI have calibrated the PMC LO Mon (C1:PSL-PMC_LODET)
on the PMC's EPICS screen, by inputting different
RF LO levels into the LO input of the PMC
 LOmonCalibration.png 
  11763   Fri Nov 13 22:32:54 2015 KojiSummaryPSLPMC LO degraded, usual ERA-5 replacement, LO recovered[Yutaro, Koji]

We found that the PMC LO level
was fluctuating in a strage way (it was not
 PMC_LO.pngIMG_2093.JPGIMG_2091.JPGIMG_2095.JPGIMG_2096.JPG 
  11765   Sun Nov 15 22:43:48 2015 KojiSummaryPSLPMC LO degraded, usual ERA-5 replacement, LO recoveredI think the IMC locking was somewhat improved.
Still it is not solid as long time before.

Before the PMC fix (attachment
 C1-MULTI_E6875C_TIMESERIES-1131408017-86400.pngC1-MULTI_E6875C_TIMESERIES-1131580817-86400.png 
  11560   Wed Sep 2 23:50:00 2015 ranaUpdatePSLPMC LO dyingLet's order a pair of 35.5 MHz Wenzel
for this guy and package like Rich has done
for the WB low noise oscillators.
 PMCLO.png 
  9381   Thu Nov 14 00:33:37 2013 ranaConfigurationPSLPMC LO is dying...Back in 2009, Jenne replaced the PMC board
mixer with a Level 13 one. Today I noticed
that the LO level on the PMC screen was showing
 Untitled.png 
  10167   Wed Jul 9 19:53:34 2014 ranaUpdatePSLPMC LO monitor trend (5 years)   LODET.png 
  15106   Fri Dec 27 16:26:11 2019 YehonathanUpdatePSLPMC Linewidth measurementI try to measure the linewidth of the PMC
by ramping the PMC PZT. 

I do it by connecting a triangular
 PMCTransmissionSpectra.pdf 
  15109   Wed Jan 1 14:14:00 2020 YehonathanUpdatePSLPMC Linewidth measurementTurns out the 35MHz sidebands are way too
weak to resolve from the resonance when doing
a PZT scan.
 150MHzSideBandCreation.pdfLinewidthMeasurment.pdf 
  15126   Wed Jan 15 15:04:31 2020 gautamUpdatePSLPMC Linewidth measurementFor the ringdowns, I suggest you replicate
the setup
I had - infrastructurally, this was quite
  
  13488   Mon Dec 18 20:37:18 2017 gautamUpdatePSLPMC MEDM cleanupThere are fewer lies on this screen now.
For reference, the details of the electronics
modifications made are in this
 PMC_revamped.png 
  1837   Wed Aug 5 15:57:05 2009 AlbertoConfigurationComputersPMC MEDM screen changedI added a clock to the PMC medm screen.
I made a backup of the original file
in the same directory and named it *.bk20090805
  
  497   Sun May 25 20:30:25 2008 ranaSummaryPSLPMC Mode MatchingI checked the PMC mode matching by ramping
the gain down to -10 dB (from +20 dB) and
moving the DC offset around until it caught
 pmc.png 
  1883   Mon Aug 10 20:49:13 2009 Alberto, RanaUpdatePSLPMC Mode Matching Lenses TuningRana, Alberto
This afternoon we tried to improve
the mode matching of the beam to the PMC.
  
  12944   Tue Apr 18 01:01:03 2017 gautamUpdatePSLPMC OLTF measured, DAQ channels calibratedQuick entry, details to follow in the AM
tomorrow.


I calibrated the PMC DAQ
 PMCspectra_calibrated.pdfPMC_MEDMs.png 
  12945   Tue Apr 18 16:10:00 2017 gautamUpdatePSLPMC OLTF measured, DAQ channels calibratedHere are the details:


PMC OLTF:


the
procedure used was identical to what Koji
 PMC_OLTF_170418.pdf 
  12946   Tue Apr 18 23:37:15 2017 ranaUpdatePSLPMC OLTF measured, DAQ channels calibratedWhat's
the reasoning behind setting the the gain
  
  1049   Wed Oct 15 17:40:50 2008 ranaUpdatePSLPMC Offset adjustedI set the PMC servo input offset: closed the
MOPA shutter, zeroed the mixer output with
the offset slider, 
  
  924   Thu Sep 4 14:43:58 2008 JenneUpdatePSLPMC Open Loop GainI have measured the PMC's open loop gain.
 [SIZE=3][COLOR=green]UGF is 629.7Hz, with
a phase margin of 53 degrees.
 OpenLoopTF04Sept2008.png 
  11781   Wed Nov 18 16:53:17 2015 KojiSummaryPSLPMC PZT capacitanceThe PMC PZT capacitance was measured.
- Turn off the HV supplies. Disconnect
HV OUT cable.
  
  699   Fri Jul 18 19:41:09 2008 YoichiUpdatePSLPMC PZT investigationI measured the HV coming to the PMC PZT by
plugging it off from the PZT and hooking
it up to a DVM.
 Hysteresis.pngStepResponse.png 
  701   Fri Jul 18 23:24:24 2008 robUpdatePSLPMC PZT investigation[quote]I measured the HV coming to the PMC
PZT by plugging it off from the PZT and hooking
it up to a DVM.
  
  702   Sat Jul 19 19:39:44 2008 robUpdatePSLPMC PZT investigation[quote][quote] The 64k is the series resistor
after the PA85, not the modeled resistance
of the PZT itself.[/quote]
  
  749   Mon Jul 28 17:44:07 2008 ranaUpdatePSLPMC PZT v. temperatureThis plot shows that the PMC [COLOR=darkblue]PZT
has ~20 Vpp fluctuations on a 24 hour timescale[/COLOR]
which is correlated to the 24 hour temperature
 Untitled.pdf 
  15138   Wed Jan 22 11:00:21 2020 gautamUpdatePSLPMC REFL ghost beamI looked into this a little more today.


The steering optic used
to route PMC REFL to the RFPD is in fact
  
  15147   Thu Jan 23 18:52:31 2020 gautamUpdatePSLPMC RFPD characterizationSummary:

The RF transimpedance of the PMC
PDH RFPD was measured, and found to be 
 PDresp.pdf 
  7337   Tue Sep 4 13:50:26 2012 ericqUpdatePSLPMC Realigned, power adjusted I adjusted the PMC alignment this
morning, brought the transmission up to 0.83V.
After the lunch meeting, we found
  
  3951   Thu Nov 18 23:45:18 2010 ranaConfigurationPSLPMC Refl CamValera
and Haixing and I installed a PMC REFL camera
 mc2_simulink.png 
  772   Wed Jul 30 16:35:56 2008 EricUpdatePSLPMC Scan GraphsGraphs of the PMC scan data that I got earlier
today. 
 PMCLongScanPeak.tiffPMCLongScanWide.tiffPMCShortScanPeak.tiffPMCShortScanWide.tiff 
  775   Thu Jul 31 10:27:17 2008 ranaUpdatePSLPMC Scan Graphs[quote]Graphs of the PMC scan data that I
got earlier today. 
[/quote]
  
  892   Wed Aug 27 13:55:43 2008 rana,jenneUpdatePSLPMC Servo BoardBoard is back in. PMC is locked.

Nominal gain is now 15 dB with brick. We
  
  895   Fri Aug 29 02:40:43 2008 rana,jenneUpdatePSLPMC Servo Board[quote]Board is back in. PMC is locked.
[/quote]
 pmclp-07.pdfpmclp_40m_080824.mpmclp.m 
  884   Tue Aug 26 09:04:59 2008 ranaConfigurationPSLPMC Servo Board: Out for RepairsI've started modifying our PMC board to bring
it up to the 21st century - [B][COLOR=blue]leave
the screen alone[/COLOR][/B] or else you
  
  11782   Wed Nov 18 17:09:22 2015 KojiSummaryPSLPMC Servo analysisSummary

The PMC servo was analysed. OLTF
was measured and modeled by ZPK (Attachment
 PMC_OLTF.pdfPMC_DSP.pdf 
  873   Sat Aug 23 09:39:51 2008 rana, jenneUpdatePSLPMC SurveyJenne, Rana

We scoped out the PMC situation yesterday.
  
  4375   Thu Mar 3 20:30:03 2011 ranaSummaryPSLPMC Sweeps @ different input power levels to measure the FinesseIts been well
noted in the past that sweeping the PMC
at high power leads to a distortion of the
  
  4417   Mon Mar 21 13:26:25 2011 KojiUpdatePSLPMC Trans/RFPDDC PMC TRANS/REFL on MEDM showed red values
for long time.
TRANS (a.k.a C1:PSL-PSL_TRANSPD) was
  
  10849   Tue Dec 30 20:35:59 2014 ranaSummaryPSLPMC Tune Up
    Calibrated the Phase Adjust
slider for the PMC RF Modulation; did this
by putting the LO and RF Mod out on the TDS
 17.pngPMCcal.ipynb.xzPMC_Osc_Cal.pdf 
  15144   Thu Jan 23 14:37:05 2020 gautamUpdatePSLPMC VGA chip damaged?[jordan, gautam]

Summary:
 VGAchar.pdf 
  15146   Thu Jan 23 16:37:14 2020 ranaUpdatePSLPMC VGA chip damaged?doesn't seem so anomolous to me; we're
getting ~25 dB of gain range and the ideal
range would be 40 dB. My guess is that even
  
  1877   Mon Aug 10 16:41:31 2009 AlbertoConfigurationPSLPMC VisibilityAlberto, Rana
lately we've been trying to better
understand what's preventing the arm power
  