Entry  Sat Jan 26 02:34:34 2008, Andrey, Update, Computer Scripts / Programs, Overnight Measuremts in XARM 

I am running the program for measuring RMS of peaks in XARM tonight. I just started it, and it will run for about 9 hours until noon on Saturday. Please
do not disturb the interferometer. Now the XARM is locked, it should stay locked over the night.
Entry  Sat Jan 26 02:08:53 2008, John, Omnistructure, LSC, Fibres 
There is now a fibre running from the SP table to the ISCT at the Y-end. In the coming days I will try to mode match the beam from this fibre into the arm
through ETMY. To achieve this I will be altering the optical layout of this table.
Entry  Sat Jan 26 02:02:43 2008, John, Summary, General, New Channels 
I added the following channels.

# C1ASC_QPDs
Entry  Fri Jan 25 21:36:40 2008, rana, Update, CDS, mDV / channel issues 
[COLOR=orange]Fri Jan 25 21:30:00 2008[/COLOR] 

As it turns out, the residual problem with the mDV stuff was not to do with our button pushing episode but instead fallout from the 'turning off of the
Entry  Fri Jan 25 17:11:07 2008, Max , Andrey, Configuration, General, NEW_FETCH_SHOUROV and GET_DATA do not work 

The problem which started yesterday after Andrey's framebuilder restart still persists.
Entry  Fri Jan 25 15:53:59 2008, Alberto, Update, Electronics, 40 dB from the 3rd order Chebyschev 166MhzElog.png
I managed to tune the 7 knobs in the 3rd order Chebyshev bandpass filter obtaining the tranfer function attached to this entry. We have now 40 dB of attenuation
between 166 Mhz and 133 and 199. With this tuning the insertion loss is rather high. We need a better one.
Entry  Fri Jan 25 13:36:13 2008, josephb, Configuration, Cameras, Working GiGE video on Mafalda 
Finally got the GiGE camera sample viewer video running on Mafalda by updating to the latest API (version 1.16 from Dec 16, 2007) from Prosilica and then
using the modified Sample Viewer code I had written.  The API version previously in cvs was 1.14.
Entry  Fri Jan 25 11:38:16 2008, josephb, Configuration, Cameras, Working GiGE video on Linux - sort of snap.tiff
1)I have been able to compile the SampleViewer program which can stream the video from the Prosilica 750C camera.  This was accomplished on my 64-bit laptop
running Ubuntu, after about 3 hours of explicitly converting strings to wxStrings and back again within the C++ code.  (There was probably an easier way
to simply overload the functions that were being called, but I wasn't sure how to go about doing so).  By connecting it to the CDS network, I was able
Entry  Thu Jan 24 20:03:40 2008, Andrey, Configuration, SUS, Changes to Dataviewer channels (XARM) 

1) [COLOR=blue]Good news.[/COLOR] I added a chanel "C1:SUS-ETMX_POS" to Dataviewer.
    Reply  Fri Jan 25 08:55:26 2008, rob, Configuration, General, Changes to Dataviewer channels (XARM) 

As a general rule,
    Reply  Fri Jan 25 10:14:35 2008, rob, Configuration, SUS, Changes to Dataviewer channels (XARM) 
[quote]
2) [COLOR=red]BAD NEWS.[/COLOR] While "clicking the appropriate blue button" on the DAQ MEDM screen,
namely [COLOR=red]CODAQ_DETAIL,adl screen, I obviously clicked some blue button that I should not have clicked, 
Entry  Fri Jan 25 09:22:21 2008, steve, Update, PEM, burned toast award goes to 
DYM for  collaborating with the enemy. 

In order to minimize the number of ants visiting our lab we have to take out side the lab
Entry  Thu Jan 24 22:52:18 2008, Andrey, Bureaucracy, General, Ants around a dirty glass (David - please read!) 

Dear coleagues,
Entry  Thu Jan 24 22:10:49 2008, Andrey, Configuration, Computer Scripts / Programs, Problem with channels - help of Rana, Robert or Steve is needed 

I definitely spoiled something (changes some settings) by chaotically clicking those blue buttons (see my previous entry # 260).
Entry  Thu Jan 24 12:50:50 2008, John, Summary, Treasure, Sugar Napoleons Sweeties.pdf
Some pictures from the group meeting yesterday.
Entry  Thu Jan 24 11:52:56 2008, steve, Update, PEM, the mud is cleaned up & MOPA shutter is opened 
Safety glasses are required again!

I have just opened the mopa shutter.
Entry  Wed Jan 23 20:52:40 2008, rana, Summary, Environment, Flooding from construction area Shop-Vac_Action.MOVFlooding.pdf
We noticed tonight around 7 PM that [B]there was a lot of brown water in the control room and also in the interferometer area[/B] mostly concentrated around
the north wall between the LSC rack and the AP table.
Entry  Wed Jan 23 12:31:36 2008, Andrey, Summary, SUS, Dissapointing Results of XARM optimization (PDF-file) Sad_Results_XARM.pdf

I attach a PDF-file which summarizes briefly the results of measurements/calculations of [COLOR=red]Q-factors for ITMX mass[/COLOR] as a function of suspension
damping gain,
Entry  Wed Jan 23 11:41:06 2008, steve, Update, PEM, sulfur smell in 40m 
Led - acid car batteries were overcharged in the machine shop next door
and sulfuric acid smell is coming over to the ifo room.
Entry  Wed Jan 23 09:27:55 2008, steve, Update, , etmy sus damping restored etmysus.jpg
Seismis event trips etmy
Entry  Tue Jan 22 13:11:03 2008, tobin, Update, ASC, ETMY oplev recentered 
The light wasn't even on the diode.
Entry  Tue Jan 22 02:33:45 2008, rob, Update, LSC, DRMI work 

0) The ETMY oplev needs work/centering
Entry  Mon Jan 21 23:30:03 2008, Andrey, Update, Computer Scripts / Programs, Matlab Program for Q-factor measurements (XARM -> ITMX and ETMX) Example-ITMX_POS_40.png

Finally I overcame difficulties with adapting Sonia's Matlab programs for XARM (Sonia's program was for MC),
Entry  Fri Jan 18 20:53:56 2008, tobin, Configuration, General, ETMY oplev 
I monkeyed around with the ETMY oplev, adding a folding mirror and moving the HeNe so that John, Sam, and I have more room for our auxiliary laser setup.
 (The ISCT-EY has more room than ISCT-EX; the latter has an extra photodiode for IP ANG.)  I believe I successfully recommissioned the oplev, though it
might not be up to the SV standard.  I verified that wiggling the ETMY alignment sliders showed corresponding wiggles in the oplev signals.  However, it
Entry  Fri Jan 18 15:31:47 2008, rob, Update, LSC, Thursday's locking DARMnoise080118.png

[I]rob, johnnie, andrey[/I]
Entry  Thu Jan 17 18:22:14 2008, Alberto, Update, Electronics, RF Monitor Band-pass Filter RF166Mhz.pngChebyshevb.pngChebyshev2b.png
After we finalized the schematic for the RF monitor board based on buffered LC resonators, on Richard Abbott's suggestion to avoid the complication brought
in by the fast op-amps, we gave another chance to the a passive configuration of the band-pass filter based on a Chebyshev topology. Rich and Ben gave
me an old but very powerful software tool to design that kind of filters and showed me the way to circumvent many hassles in making RF test boards.
    Reply  Fri Jan 18 11:53:50 2008, Alberto, Update, Electronics, RF Monitor Band-pass Filter Chebyshevb.png
The response is asymmetric and on the left side of the peak, we have at least 33dB within 33Mhz, which is enough for all the frequencies. We probably don't
need an higher order filter but just low pass filters in series.
Entry  Thu Jan 17 20:50:55 2008, tobin, Update, General, fiber coupling 
Sam, John, and I matched the beam from an NPRO into a fiber on the SP table today.  In doing so we used our GigE camera for a physics application for perhaps
the first time, viewing the transmitted mode from the fiber during initial alignment.  (I used my laptop running Windows and a 100 megabit switch.)
Entry  Thu Jan 17 15:11:13 2008, josephb, Update, Cameras, Working on Malfalda 
1) I can statically compile the ListCamera code (which basically just goes out and finds what cameras are connected to the network) on Malfalda and use
that compiled code to run on Linux2 without a problem.  Simply needed to add explicit links to libpthread.a and librt.a.
(i.e. -Bstatic -L /usr/lib/ -lpthread -Bstatic -L /usr/lib -lrt)
Entry  Thu Jan 17 14:13:20 2008, rob, Update, LSC, Wednesday's locking 
Incremental progress on locking yet again.  This time the handoff of DARM to the OMC worked, and progress halted at handing off control of the common mode
to REFL166.  
Entry  Wed Jan 16 19:57:49 2008, tobin, Configuration, Photos, ISCT_EX trx-annotated-small.jpg
Here's a photo of the ISCT_EX table, for the purpose of planning our auxiliary laser arm locking scheme.   Note the (undumped!) beam from the beamsplitter
before QPDX (the leftmost gold-colored box); perhaps we could inject there.
Entry  Wed Jan 16 18:24:41 2008, rana, Update, SUS, ETMY Watchdog A.pdf
Because [COLOR=purple][B]Steve keeps complaining about ETMY[/B][/COLOR], I looked at some minute trend to see if there was something exotic happening at
that time. It looks like there is some tremendous seismic activity to make it happen.
Entry  Wed Jan 16 14:09:45 2008, rob, Update, LSC, tuesday's locking 

I got a little further with the locking (PRFPMI) last night, after discovering that the cable going from the CM board to the MC board was unplugged at
the MC side.  This explains why we weren't able to engage the AO path last night.  Tonight, I got up to the point where DARM is handed off to OMC transmission,
Entry  Wed Jan 16 14:06:24 2008, rob, Update, LSC, monday's locking 
rob, tobin, johnnie

We did some locking work monday night, with decent progress.  Working in the PRFPMI style, we managed to get through the part of the script that hands
Entry  Tue Jan 15 13:15:27 2008, tobin, Update, Environment, lots of noise 
They're throwing concrete around at the construction site.
Entry  Mon Jan 14 23:11:26 2008, tobin, Configuration, General, fiber 
John and I removed the fiber that ran from the SP table to the cleanroom.  We plan to build a MZ interferometer with this fiber inserted into one of the
arms, for the purpose of measuring its phase noise.
Entry  Mon Jan 14 14:41:09 2008, steve, Update, SUS, etmy sus damping restored & mz relocked etmysus&mzhvtrend.jpg
Tree days trend of MZ HV drift is typical these days.
So as the etmy sus inability to hold damping for longer then 2-3 days.
Entry  Fri Jan 11 17:01:51 2008, pkp, Update, Cameras, GigE again  
So, here I detail all the efforts on the GigE so far 

(1) The GiGE camera requires a minimum of 9 kb packet size, which is not available on mafalda or on my laptop ( both of which run Ubuntu and the Camera
Entry  Thu Jan 10 15:04:04 2008, steve, Update, SUS, illuminator light effect on BS position bssusilum.jpg
The bs chamber illuminator light was turned on this morning and left on.
Earlier on Rana noticed that the bs moved.
I follwed up to see what happened. I turned off oplev servo and tried to recenter on oplev pd
Entry  Thu Jan 10 13:45:52 2008, Pkp, Update, Cameras, GLIBC Error 
So, I have tried to compile the camera files which are in /cvs/cds/caltech/target/Prosilica/examples for the past 2 days now and have been unable to get
rid of the following error. (specifically ListCameras.cpp, as it doesnt have any other libraries required, which unnecessarily complicates things)
Entry  Thu Jan 10 12:08:23 2008, steve, Update, SUS, why did the BS move? bshopped.jpg
 
Entry  Thu Jan 10 10:38:02 2008, steve, Update, SUS, etmy damping restored etmysus.jpgsustrend16d.jpg
The IST building onstruction has really started yesterday and continuing today with big heavy ground breaking
machinary. The MC is holding lock and the suspentions are hanging on.
Entry  Thu Jan 10 00:12:01 2008, tobin, Summary, Locking, DR 
[John, Tobin, Rana]

1.  We found SUS_BS_SENSOR_UL to have a ratty signal and low DC value.  Twiddling the cables at the BS satellite amplifier and vacuum feedthrough brought
Entry  Wed Jan 9 20:36:42 2008, Go, Update, Treasure, Money in lab DSC_0370.JPG
Go's Desk.
Entry  Wed Jan 9 20:29:47 2008, Dmass, AoG, TMI, Coffee Carafe DSC_0363.JPGDSC_0365.JPGDSC_0368.JPG
If you have been using the coffee machine in the 40m, you may have noticed small brown flecks in your coffee mug. The carafe in the 40m has accumulated
a layer of what is presumed to be old dried up coffee. When a small amount of water is swirled around in the bottom, flecks of the brown layer come off.
Pictures below are of the inside of the carafe.
Entry  Wed Jan 9 10:47:15 2008, fricke, Update, Computers, ethernet wiring in office/control room 
The electrical people have been here for three days, installing ethernet cables and drops in the 40m office area, in the old conduits where there was power
and 10base2.  Soon we will have reliable ethernet connections, instead of relying on switches hanging from the ceiling, etc!
Entry  Tue Jan 8 15:20:17 2008, Pkp, Update, Cameras, GigE update 
[Tobin , Pinkesh]

Finally we got the camera doing something (other than giving out its attributes). The only thing that seems to work so far is a program called AAviewer,
Entry  Mon Jan 7 09:01:39 2008, steve, Update, SUS, BS sus damping restored bssdl.jpg
The BS sus damping was lost at 8am Sunday morning.
Entry  Fri Jan 4 08:42:03 2008, steve, Update, SUS, etmy trips again etmy20m.jpgetmy120s.jpgetmysenV.jpg
ETMY sus damping tripped at 6am this morning
It was reset. We should put an accelerometer to the south end to see
the garbage dumping effect.
Entry  Thu Jan 3 09:55:11 2008, steve, Update, SUS, etmy sus damping restored etmy12h.jpg
ETMY watch dog was lost at midnight
Entry  Thu Jan 3 09:12:59 2008, steve, Update, PSL, MZ servo mz1y.jpgmz40d.jpg
Here is MZ trend for one year and 40 days.
Now days it runs out of range on the low side.
This is the weakest link in the psl today.
Entry  Thu Jan 3 08:53:55 2008, steve, Update, SUS, etmy vs etmx sus.jpg
Rana have corrected sus gain damping setting of ETMY 8 days ago

gain settings: pos, pit, yaw & sd
Entry  Wed Jan 2 11:38:56 2008, tobin, Summary, WIKI-40M Update, wiki spam 
Our wiki keeps getting spammed.  It turns out that you can upload attachments without a password, which is a bug.  I'll ask David Barker whether there's
a fix for this.
ELOG V3.1.3-