40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 167 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  6486   Wed Apr 4 23:57:35 2012 keikoUpdateLSCRAM simulation for Full ifo I'm still wondering whether iteration
version or simple version is closer approximation
to the real situation. Sorry for few explanations
  
  6487   Thu Apr 5 01:07:08 2012 Mike J.UpdateComputersHysteresis PlotsHere are the hysteresis plots from the
most recent
model, which uses a modified harmonic
 SHO_hyst_plot.png 
  6488   Thu Apr 5 06:27:51 2012 kiwamuUpdateLSCAS110 sideband monitor installed[Jenne / Kiwamu]

 We
  
  6489   Thu Apr 5 07:19:16 2012 kiwamuUpdateLSCDRMI locking I
tried locking the DRMI to the signal-extraction
condition with the new trigger by AS110.
 DRMI_2012Apr4_edit.png 
  6491   Fri Apr 6 09:57:24 2012 DenUpdateAdaptive Filteringstatic starts to workI made static filter to work to evaluate
the actuator TF.. Here is the result of static
filtering:
 7x 
  6492   Fri Apr 6 10:31:07 2012 DenUpdateAdaptive Filteringstatic and adaptiveI've run static and adaptive filters simultaneously.
AA32 filters rotate the phase of the witness
signals GUR1X and GUR1Y and now the performance
 static_oaf.pdf 
  6493   Fri Apr 6 11:14:34 2012 JenneUpdateAdaptive Filteringstatic and adaptive

    

       
            
  
  6494   Fri Apr 6 11:32:09 2012 JenneUpdateComputersRAID array is rebuilding....Suresh reported to Den, who reported to
me (although no elogs were made.....) that
something was funny with the FB.  I
  
  6495   Fri Apr 6 14:39:21 2012 JamieUpdateComputersRAID array is rebuilding....The RAID (JetStor SATA 416S) is indeed
resyncing itself after a disk failure. 
There is a hot spare, so it's stable for
  
  6496   Fri Apr 6 15:06:05 2012 DenUpdateIOO1 Hz resonanceI think we can try to damp 1 Hz resonance
more. In September it was not seen because
of the digital noise. After we've figured
 psd_mcl.jpgmcl.jpg 
  6497   Fri Apr 6 16:22:15 2012 DenUpdateEnvironmentseism boxI've changed R2 resistor in the seism box
for the VERT 1 channel from 464 Ohm to 1051
Ohm to reduce the gain of this channel by
  
  6498   Fri Apr 6 16:35:37 2012 DenUpdateComputersc1iooc1ioo computer can not connect to the framebuilder
and everything is red in the status for this
machine, C1:FEC-33_CPU_METER is not moving.
  
  6499   Fri Apr 6 19:04:35 2012 JenneUpdatePEMSTS releveled, GUR2 plugged in[Den, Jenne]
We were wondering why the STS-2 signal
was funny.  When I went to look at it,
  
  6502   Fri Apr 6 20:24:31 2012 Mike J.UpdateComputersSensorayThe Sensoray device is currently viewing
Monitor 4 and plugged into Pianosa. 
The user interface is run at /home/controls/Downloads/sdk_2253_1.2.2_linux/python
  
  6503   Fri Apr 6 20:38:41 2012 Mike J.UpdateComputersSensoray Turns out that the "MPEG-4 VES"
video format is just bad for captured video. 
Everything except "MP4" and "MPEG-TS"
  
  6504   Sat Apr 7 00:31:12 2012 keikoUpdateLSCRAM simulation for Full ifoI didn't
understand how CARM can be decreased 2 orderes
of magnitude and PRCL can be INCREASED by
 plot4a.pngplot4b.png 
  6505   Sat Apr 7 01:45:02 2012 Mike J.UpdateComputersEven Better Hysteresis Model and Plots The new hysteresis model is slightly
based on the SHO equation, but with the force
being out of phase with the position by an
 hyst_v3.pnghyst_v_3.pnghyst_v_3-x(t).png 
  6506   Sat Apr 7 01:56:05 2012 kiwamuUpdateLSCOSA signal in DRMI conditionIt wasn't a dream or illusion -- I was
locking the DRMI to the right condition last
Wednesday (#6489).
 OSA.png 
  6507   Sat Apr 7 02:01:29 2012 Mike J.UpdateComputersProjector Cable ManagementI replaced the projector video and power
cables with longer ones, and zip-tied them
to the ceiling and wall so they don't block
 projector_cables.jpg 
  6508   Sat Apr 7 06:58:34 2012 kiwamuUpdateLSCDRMI lock : lost good alignmentSomehow I lost the good alignment, where
the lock can be frequently acquired and hence
I didn't go further ahead.
  
  6509   Mon Apr 9 15:02:30 2012 JenneUpdateLSCLocked MICHI was going to try some locking, but things
are a little too noisy. 
Just so Kiwamu knows what I did today,
  
  6510   Mon Apr 9 15:09:34 2012 JenneUpdateLSCLocked MICH

    
        
  
  6511   Mon Apr 9 17:03:38 2012 DenUpdateEnvironmentLms vs WienerI tried to figure out why offline LMS filter
subtract seismic noise much better from MC_F
then the Wiener filter. I did the calculations
 gur12_mcl.pngseismboxnoise.pnggur1_osem.pngmcl_noise.jpg 
  6512   Mon Apr 9 18:18:14 2012 kiwamuUpdateLSCDRMI time seriesHere is a time series when the DRMI is
being locked.
You can see that the AS110 goes up
 time_series1.png 
  6513   Mon Apr 9 20:02:19 2012 Mike J.UpdateComputersSensorayThe highest resolution available is 720x480
pixels. Bit depth of captured images and
video is most likely 16 bits per pixel. Video
 out_0.jpg 
  6514   Tue Apr 10 11:08:29 2012 taraUpdatePSLcurved mirror behind AOM removedWe removed the curved mirror behind the
AOM (ROC=0.3m) on PSL table. The mirror is
now in PSL lab. See PSL:905
  
  6515   Tue Apr 10 13:42:54 2012 JenneUpdateEnvironmentPlumbing guys are hereI don't know why, but they're looking around
on the roof, and inside our ceiling above
the bathrooms.
  
  6516   Tue Apr 10 17:02:29 2012 JenneUpdateIOOMode matching recollections and conclusions...Mostly just recollections at this point.
I re-looked at the mode matching's
sensitivity to misplaced optics.  Here
 IMMT_positionSensitivity_plotted10Apr2012_LowRes.pngHistogram_20mmStDev_MMTmovesOnly_LowRes.pngHistogram_20mmStDev_MMTmovesAndTilts_LowRes.png 
  6517   Tue Apr 10 23:56:44 2012 ranaUpdateComputersSensorayNow that Mike has got the Sensoray working,
Jenne/Suresh should grab some new images
of the ETM cage as Keiko did so that we can
  
  6518   Wed Apr 11 12:25:11 2012 RyanUpdateComputersUpdating aLIGO ConlogOver the next few days, I will be working
on upgrading the aLIGO Conlog install to
include new bugfixes distributed by Patrick
  
  6519   Wed Apr 11 14:34:48 2012 JenneUpdateEnvironmentPlumbing guys are here

    

       
            
  
  6521   Wed Apr 11 17:56:26 2012 JenneUpdateGeneralSummary of things to figure out with the IFOQuestions:
Power recycling gain
   * It should be ~40,
  
  6522   Wed Apr 11 18:19:51 2012 JenneUpdateIOOMode matching recollections and conclusionsAnother histogram.  This one allows
the MMT mirror positions to move, the MMT
incident angle for both curved optics to
 ModeMismatch_MMTpos_MMTang_MCw0_MCwz_change_LowRes.png 
  6523   Wed Apr 11 22:48:39 2012 ranaUpdateEnvironmentBLRMS   seis_blrms.png 
  6524   Thu Apr 12 00:16:38 2012 JenneUpdateEnvironmentEarthquake - moderate 

M4.7  - Santa Isabel, Mexico
2012-04-12 06:48:38 UTC
Mode
  
  6525   Thu Apr 12 00:40:45 2012 JenneUpdateSUSPRM, BS oplevs offThere's a beam dump after the HeNe on the
BS oplev table, since the IPPOS measurement
optics (steering mirrors) are in the way
  
  6526   Thu Apr 12 01:17:56 2012 SureshUpdateIOOBeam Profile measurement: IPPOS beam: Possible Clipping[Suresh, Jenne]
  The
input beam is most probably being clipped
 BeamProfileData_IPPOS_2.xlsx 
  6527   Thu Apr 12 08:49:14 2012 DenUpdateSUSlocal damping and WFSI tried to figure out what can add noise
below 0.5 Hz to the MC_F. I compared MC1,
MC2, MC3 suspos, suspit, susyaw and susside
 6x 
  6528   Thu Apr 12 14:48:44 2012 SureshUpdateSUSlocal damping and WFS    WFS servo is moving
the MC mirror angles to minimise TEM01 and
TEM10 modes within the MC cavity.   
  
  6529   Thu Apr 12 20:56:07 2012 DenUpdatePEMdaqGUR1 XYZ, GUR2 XYZ, MC_F channels are now
recorded at 256 Hz.
  
  6530   Thu Apr 12 22:04:17 2012 Mike J.UpdateComputersNew Hysteresis Model & PlotsThe new hysteresis model uses a triangle
wave with offset zero points as the position
function and a sinusoidal force function,
 hyst_combo.pngferro_hyst.png 
  6531   Thu Apr 12 23:12:16 2012 SureshUpdateIOOBeam Profile measurement: IPPOS beam: Possible Clipping

    

       
            
 6x 
  6532   Thu Apr 12 23:52:49 2012 JenneUpdateLockingPRMI locked - 'bouncy'I am locking some things, and have the
PRM aligned, and it will stay locked for
short periods of time, but as Kiwamu warned
  
  6533   Fri Apr 13 01:27:10 2012 JenneUpdateSUSOplevs recenteredIt's been a while since I think anyone
has done it, and several optics were pretty
far from centered, so I centered all of the
  
  6534   Fri Apr 13 16:09:43 2012 SureshUpdateComputer Scripts / ProgramsACAD 2002 installed on C21530I have installed
ACAD 2002 on one of the Windows machines
  
  6536   Mon Apr 16 09:10:37 2012 DenUpdatePEMgur2_xAlready not for the first time I notice
that GUR2 readjusts its X zero position
 seisms.pnggur12_coh.jpg 
  6537   Mon Apr 16 09:44:54 2012 JenneUpdatePEMgur2_x

    

       
            
  
  6538   Mon Apr 16 14:37:01 2012 DenUpdatePEMgur2_x

    

       
            
  
  6539   Tue Apr 17 10:55:50 2012 RyanUpdateComputersUpdating aLIGO Conlog

    

       
            
  
  6540   Tue Apr 17 11:05:04 2012 JamieUpdateCDSCDS upgrade in progressI am continuing to attempt to upgrade the
CDS system to RTS 2.5.  Systems will
continue to be up and down for the rest of
  
ELOG V3.1.3-