  7275   Fri Aug 24 22:01:15 2012 JenneUpdateIOOMC spot position - closeI am getting closer with the MC spot centering. 
I had everything but MC1 really great, but
then I tweaked MC1's pointing, and things
 MCdecenter_24Aug2012.png 
  7276   Sun Aug 26 11:53:09 2012 JenneUpdateIOOMC2 getting kicked up regularlyWe need to re-look at this new MC autolocker
stuff, and the new MCL filters.
MC2 is getting kicked up (sometimes
  
  7277   Sun Aug 26 12:26:44 2012 JenneUpdateIOOMC spot position - not done yet

    

       
            
  
  7280   Mon Aug 27 01:05:36 2012 JenneUpdateIOOMC spot position - callin' it quitsspot positions in mm (MC1,2,3 pit MC1,2,3
yaw):
[-0.98675603448324423, -0.94064212026141558,
 MCdecenter_26Aug2012.png 
  7284   Mon Aug 27 12:03:54 2012 KojiUpdateIOOMC spot position - callin' it quitsThe MC REFL path was checked. ==> Some
clippings were fixed. MC WFS is working now.
- MC was aligned manually
  
  7288   Mon Aug 27 18:32:48 2012 JenneUpdateIOOMC spot position - Jenne is stupid

    

       
            
  
  7289   Mon Aug 27 18:59:24 2012 jamieUpdateIOOMC ASC screen was confusing - Jenne is not stupid

    

       
            
 Screenshot-1.pngScreenshot-2.png 
  7290   Mon Aug 27 23:52:59 2012 JenneUpdateIOOMC Spots centeredFinally!
Jamie and I have the MC spots centered. 
We did the normal move the input beam, realign
 MCdecenter_26Aug2012.png 
  7312   Wed Aug 29 20:43:23 2012 KojiUpdateIOOSetup for a cavity scan or the input mode cleanerThe technique is based on detection of
the beating between the resonant carrier
and a resonant higher order mode.
  
  7313   Wed Aug 29 21:02:45 2012 JenneUpdateIOOOptics between Faraday and PRM are centered, realigned[Jenne, Suresh, with support from Jamie
and Koji]
MC spots measured, MC1, MC3 no change.
  
  7320   Thu Aug 30 18:01:05 2012 ElliUpdateIOOSetting up Input MC cavity scan measurementRiju, Elli
Today tried to take our first cavity
scan.  We unplugged the 55MHz sideband
  
  7323   Thu Aug 30 20:31:35 2012 JenneUpdateIOOPZT1 and PZT2 set to center of their ranges[Koji, Jenne]
Jamie and Koji pointed out that we
need to be doing the in-vac alignment with
  
  7328   Fri Aug 31 13:22:29 2012 ElliUpdateIOOCorrecting improper termination of the 55MHz input to the EOMKoji, Riju, Elli
This morning Koji discovered that
the 55MHz input into the RF combiner that
  
  7332   Fri Aug 31 18:32:47 2012 KojiUpdateIOOCorrecting improper termination of the 55MHz input to the EOM 
The power switch of the frequency
source was mechanically broken. I replace
  
  7349   Thu Sep 6 13:07:02 2012 JenneUpdateIOOIPANG no longer a reference :(I was having trouble centering IPANG using
the PZTs, and I suspected something funny
was going on at the end.  I went down
  
  7407   Wed Sep 19 09:24:01 2012 SteveOmnistructureIOOaccess connector at athmoshere

    

       
            
 IMG_1641.JPGIMG_1642.JPGacetateAC.png 
  7410   Wed Sep 19 13:12:48 2012 JenneUpdateIOOPower into vacuum increased to 75mWThe power buildup in the MC is ~400, so
100mW of incident power would give about
40W circulating in the mode cleaner.
  
  7439   Tue Sep 25 22:40:55 2012 JenneUpdateIOOIPANG ND filter installed[Jenne, Evan Hall]
Both IPPOS and IPANG beams are (after
turning on the input and output PZTs) hitting
  
  7440   Wed Sep 26 01:10:34 2012 JenneUpdateIOOPZT2 not working?!?! MC back to normal[Jenne, Evan, Den]
MC REFL beam is back on the PD,
and the mode cleaner locks.  It
  
  7442   Wed Sep 26 16:59:30 2012 jamieUpdateIOOIPANG ND filter installed

    

       
            
  
  7444   Wed Sep 26 23:55:14 2012 JenneUpdateIOOWFS centeredSince the MC spots are good, I put the
beam back on WFS 1 and WFS 2.
Also, I changed the indicators on
  
  7452   Fri Sep 28 21:17:41 2012 KojiUpdateIOOMC WFS adjustmentMC
WFS was fixed. Now it is running constantly
with the autolocker.
 MC_WFS_12h.png 
  7455   Mon Oct 1 11:08:25 2012 JenneUpdateIOOMC WFS adjustment

    

       
            
  
  7456   Mon Oct 1 13:11:43 2012 JenneUpdateIOOPZT inspection elogsI'll come back to the PZTs later, but I
want to write down all the elogs I have found
so far that look relevant.
  
  7462   Tue Oct 2 14:20:33 2012 ManasaConfigurationIOOPDA255 not workingThe PDA255 that Koji repaired is still
not alright. It seems to be saturating again.
I've left it in the PD cabinet where it is
  
  7463   Tue Oct 2 15:14:54 2012 jenne, jamieUpdateIOOPZT diagnosispzt2 mod signals matched slider vals for
both pitch and yaw

  pzt2 yaw mon output = 6
 
  
  7465   Tue Oct 2 16:32:43 2012 JenneUpdateIOOPZT diagnosis[Koji, Jenne]
Jamie and I pulled the whole PZT
driver for both PZT1 and PZT2. 
  
  7469   Wed Oct 3 15:58:57 2012 SteveConfigurationIOOSOS coil drivers movedThe SOS coil drivers (Atm2) were moved
from 1X1 to 1Y2 location. Is this the best
place to locate the  IOO Tip-Tilt steering
 SOScoildriversTT.jpgIMG_1680.JPG 
  7472   Wed Oct 3 18:45:51 2012 jamieUpdateIOOwiki page for active IO tip-tiltsI made a wiki
page for the active IO tip-tilts. 
I should have made this a long time ago.
  
  7475   Thu Oct 4 01:06:52 2012 JenneUpdateIOOPZT diagnosis[Koji, Jenne]
We naively hoped that just replacing
the fuses would fix the problem with the
  
  7504   Mon Oct 8 14:19:17 2012 JenneUpdateIOOPZT diagnosis - not fixed yet

    

       
            
  
  7505   Mon Oct 8 18:45:48 2012 JenneUpdateIOOPZT diagnosis - not fixed yet, possible solutionAfter the fuse-blowing fiasco earlier
this afternoon, Koji and I took another look
at the PZT controllers.
  
  7506   Mon Oct 8 21:42:17 2012 JenneUpdateIOOPZT diagnosis - not fixed yet, possible solutionNote to self:
The ENV-40 amplifiers that we have
supply -10V through +150V .... so don't exceed
  
  7509   Tue Oct 9 00:25:33 2012 JenneUpdateIOOPZTs - hacky solution in place!![Evan, Jenne]
We applied some volts across both
the pitch and yaw pin sets of the ribbon
  
  7510   Tue Oct 9 09:29:10 2012 SteveUpdateIOOthis is where we are

    

       
            
 15days.png 
  7518   Wed Oct 10 10:55:56 2012 SteveOmnistructureIOOaccess connector at athmoshere

    

       
            
 10101202.PDF 
  7521   Wed Oct 10 19:22:03 2012 jamieUpdateIOOAdded control for input tip-tilts to c1assI have added some control logic and appropriate
output DAC channels for the input tip-tilts
(TT1 and TT2) to the c1ass model.
 2012-10-10-185707_566x330_scrot.png2012-10-10-191013_470x277_scrot.png 
  7522   Wed Oct 10 20:27:40 2012 DenUpdateIOOMCL, WFS triggersI've added MCL and WFS stop triggers into
C1MCS/SUS model. Threshold value of MC_TRANS
can be changed in the text entry located
 MC2_POS.pngmcl.pdf 
  7530   Thu Oct 11 12:02:15 2012 DenUpdateIOOFSSFSS SLOW control did not drift during the
lock at night with MCL path working and AC
coupled.
 fss.png 
  7531   Thu Oct 11 12:11:23 2012 jamieUpdateIOOc1ass with new DAC0 output has been recompiled/install/restartedI rebuilt/install/restarted c1ass. 
It came up with no problems.  It's now
showing DAC0 with no errors.
  
  7550   Mon Oct 15 20:45:58 2012 jamieUpdateIOOc1lsc DAC0 now connected to tip-tilt SOS DW boardsThe tip-tile SOS dewhite/AI boards are
now connected to the digital system.
 20121015_190340.png 
  7553   Tue Oct 16 00:08:26 2012 DenUpdateIOOc1lsc DAC0 now connected to tip-tilt SOS DW boards

    

       
            
 DSC_4748.JPG 
  7557   Tue Oct 16 11:54:05 2012 JenneUpdateIOOMC alignment??The MC won't survive the boosts right now. 
Pizza meeting is in a minute, and I won't
be back to the lab before ~3:30 because of
  
  7561   Tue Oct 16 20:40:06 2012 DenUpdateIOOc1lsc DAC0 now connected to tip-tilt SOS DW boards  Full cable path from coil driver
to osem input is now ready. I've tested Ch1-4
of the left AI and left coil driver. 15 pin
 DSC_4749.JPGDSC_4755.JPG 
  7572   Thu Oct 18 03:45:56 2012 JenneUpdateIOOMCL, WFS triggers

    

       
            
  
  7575   Thu Oct 18 12:02:32 2012 DenUpdateIOOMCL, WFS triggers

    

       
            
  
  7578   Fri Oct 19 01:11:18 2012 JenneUpdateIOOMCL, WFS triggers

    

       
            
  
  7620   Thu Oct 25 09:32:17 2012 SteveOmnistructureIOOusing access connector

    

       
            
 acclosing.jpg 
  7699   Tue Nov 13 00:15:08 2012 JenneUpdateIOOInput and Output PZTs turned onI turned on the power supplies for the
output PZTs and pitch and yaw for PZT2. 
This is back to the condition that we had
  
  7702   Tue Nov 13 00:28:10 2012 AyakaUpdateIOOMC locked, spots centered[Rana, Ayaka, Jenne]
We aligned the REFL beam to the center
of PD.
 spot1112.pngDSC_4902.JPGDSC_4904.JPG 