  3165   Wed Jul 7 11:23:08 2010 Sharmila, KatharineUpdateWIKI-40M Update Weekly Update:
Last Weds-Thurs, we wrote and edited
our progress reports.
  
  3214   Wed Jul 14 11:32:36 2010 Sharmila, KatharineUpdateWIKI-40M Update Weekly update:

We correctly connected our circuit
  
  3114   Thu Jun 24 11:16:32 2010 Sharmila, Rana and KiwamuHowToVACInspection of the BS (sorry, no sounds)    
  3212   Wed Jul 14 01:05:27 2010 Sharmila,KatharineSummaryelogMaglevYesterday we hooked up the Quadrant Maglev
control to the power supply to test the components
in the Input/Output part of the circuit.
 P7120284.JPGP7120278.JPGP7120281.JPGP7140292.JPG 
  3250   Tue Jul 20 11:55:15 2010 Sharmila,KatharineUpdateelogMaglevWe plotted the transfer functions for the
maglev control circuit and compared them
with the plots from the spectrum 
 tf.pngP7140292.JPG 
  3305   Wed Jul 28 12:09:06 2010 Sharmila,KatharineUpdateWIKI-40M UpdateMaglevWe have modeled our maglev setup in simulink
but we have a few corrections to make since
the system goes into undamped oscillations
 Picture_1.png 
  3112   Thu Jun 24 01:02:34 2010 Sharmilla, Rana and KiwamuUpdateGreen Lockinga channel for PPKTP temperatureWe added
a channel on c1psl in order to monitor the
  
  563   Wed Jun 25 09:46:45 2008 SharonUpdate Adaptive FiltersI have been learning about different methods
for applying adaptive filters to improve
the Mode Cleaner lock in specific, and other
  
  704   Mon Jul 21 09:52:05 2008 SharonUpdate Adaptive code changesThanks to Alex, we now save the coefficients
of the adaptive filter every cycle. When
we choose ENABLE: OFF on the MEDM screen,
  
  709   Mon Jul 21 19:48:57 2008 SharonUpdate how tp restart C1ASSHow to restart C1ASS:

1. reboot
  
  720   Wed Jul 23 10:47:05 2008 SharonUpdate Weekly updateThis week I spent some time with Alex who
updated the adaptive code to save the filter's
coeffs all the time, stop when I open the
  
  723   Wed Jul 23 13:52:26 2008 SharonUpdate MEDM changesThere is a new MEDM screen now when you go
from c1ass>top>pem.
Instead of having 12 "mini filters" screens
 matrix 
  739   Fri Jul 25 13:30:53 2008 SharonUpdate Changes in ASS computerI editted the simulink diagram of the ASS
computer so it now has 2 more channels reading
2 sets of the FIR coefficients to match Alex's
  
  740   Fri Jul 25 17:32:46 2008 SharonUpdate ASS computerSo, it seems a bit too complicated getting
the coefficients the way I wanted it to happen
(simulink-.ini...). 
  
  747   Mon Jul 28 12:02:32 2008 SharonUpdate accelerometers settingsJenne, Sharon

  
  750   Mon Jul 28 17:58:05 2008 SharonUpdate TOP screen changesI wanted to test the adaptive code with a
downsampling rate of 32 instead of 16. To
do this I entered a 32 Hz ((2048/32)/2 -
  
  760   Tue Jul 29 21:04:55 2008 SharonUpdate OSEM's Power SpectrumFrom 16:30 this afternoon  8x 
  765   Wed Jul 30 12:36:19 2008 SharonUpdate Weekly updateThis week included many computer's issues.
I tested Alex's new C code (the one that
saves the FIR coefficients and restores them
  
  814   Fri Aug 8 11:04:34 2008 SharonUpdate MCL Wiener filterI took some old data from Rana and converted
the units of the Weiner filter to m/m so
to make the effect of the seismometer and
 m_per_m.png 
  841   Fri Aug 15 16:45:43 2008 SharonUpdate Converting from FIR to IIRI have been looking into different techniques
to convert from FIR to IIR. This is so we
can see how effective the adaptive FIR filter
 fir2iir50.pngfir2iir400.pngfir2iir1000.png 
  850   Tue Aug 19 10:36:34 2008 SharonUpdate Calibrating accelerometersI took apart the accelerometers near MC1 and
MC2.
The 2 sets of 3 accelerometers are now covered
  
  853   Tue Aug 19 14:25:38 2008 SharonUpdatePEMAccelerometer's calibration - update[COLOR=blue][B]Goal[/B][/COLOR] - Make sure
the accelerometers are calibrated among themselves
(have the same power spectrum when they are
 acccalibafter.pngacccalibbefore.png 
  854   Tue Aug 19 17:00:19 2008 SharonUpdate Wiener TF calibration - update[I]This is an update for post 814[/I]

I added the calibration gains I got for the
 m_per_m.png 
  855   Tue Aug 19 17:15:34 2008 SharonUpdate MEDMI plugged in the gains I got for the accelerometers
in the accelerometers' filters in the PEM
screen of the adaptive filter
  
  863   Wed Aug 20 17:02:01 2008 SharonUpdate More FIR to IIR I tested another method for converting from
FIR to IIR other than the 2 mentioned in
post 841.
 polefit1.pdf 
  870   Fri Aug 22 13:58:39 2008 SharonSummary Trend of the Wiener TFIn order to understand if we really need an
adaptive filter, I used old data of MC_L
and the accelerometers and seismometer to
 Same_start_time1.pdfsame_length.pdf 
  4846   Tue Jun 21 00:38:21 2011 SonaliUpdateGreen Lockingrepositioned "QPDY_PD"1.The aim is the laser frequency stabilisation
of PSL and AUX.
2.As a first step we want to couple
 ETMY_table_2011_June20.pngETMY_table_change1.jpg 
  4852   Wed Jun 22 01:59:43 2011 SonaliUpdateGreen Lockingfibre-coupling of the IR beam  What
I did today.
1. Collimation of a beam.
 ETMY_june_21.jpgcollimation_700nm_21_june.JPG 
  4862   Thu Jun 23 02:12:12 2011 SonaliUpdateGreen Lockingwork schedule. June 22-June 24:
1.Coupling
light into fibre at the ETMY.
  
  4882   Sat Jun 25 00:00:28 2011 SonaliUpdateGreen LockingFibre Coupling. What I did today.
1. I tried to align the IR input
beam by aligning the two mirrors, to couple
 Fibre_coupling_successful_24_june.jpgBeam_output_on_screen.jpg 
  4901   Tue Jun 28 16:52:37 2011 SonaliUpdateGreen LockingRouting of fibre to PSL complete.1. Suresh and I completed the alignment
of the fibre and the three mirrors on the
ETMY table.
 coupled_fibre.jpgthe_fibre_route.jpgETMY_aftr_fibre_coupling2.png 
  4977   Fri Jul 15 17:42:21 2011 SonaliUpdateGreen LockingPSL layout for superposition of the PSL,ETMX and ETMY beams.The fibres carrying the beams from the
ETMX as well as the ETMY have been routed
to the PSL table now.
 PSL_change1.pdfPSLnewspace1.pdf 
  4997   Wed Jul 20 10:10:19 2011 SonaliUpdateGreen LockingWeekly summary I finished wih the set-up at the
ETMY table. Instead of the neutral Density
Filter , I put in a mirror(Y1-1037-45S)  which
  
  5039   Wed Jul 27 01:57:28 2011 SonaliUpdateGreen LockingWeekly Summary1. I have used the PMC  trans beam
in my set-up as the required PSL beam.
2. I have superposed the ETMX-Fibre
  
  5052   Thu Jul 28 13:51:00 2011 SonaliUpdateGreen LockingZHL-32A-S.Initially I was using RFPD-1611to get the
IR beat frequency. Its gain was not very
high, so I was getting a very low signal
  
  5057   Thu Jul 28 19:49:12 2011 SonaliUpdatePSLPMC trans beam aligned.Kiwamu and I aligned the PMC transmitted
beam the incident beam going to
PMC today.
  
  1695   Wed Jun 24 11:20:40 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI have created the attached EOM circuit
with resonances at 11 MHz, 29.5 MHz, and
55 MHz (the magnitude and phase of the voltage
 EOM_CktDiagram.JPGEOM_VoltagePlot.JPG 
  1711   Wed Jul 1 11:00:52 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateSince last week, I have come up with a
new circuit, which is shown in the attached
figure. The magnitude (solid) and phase (dashed)
 EOMCKT.pngPR1_VoltagePlot.pdf 
  1719   Wed Jul 8 10:56:04 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateThis week, I've been working on adapting
the last week's circuit to make it buildable.
Mostly this has involved picking components
 DSC_0566.JPGInitialBuiltCkt.pdfBuiltCkt_ExpectedResponse.png 
  1748   Wed Jul 15 12:11:17 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateThis week I've been working on testing
the first version of the prototype circuit.
Initially, I tested the circuit that I built
 MeasuredTransferFunction_R.jpgBuiltCkt_ExpectedResponse.pngMeasuredTransferFunction.jpg 
  1754   Wed Jul 15 18:35:11 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateUsing FET probes, I was able to measure
a transfer function that looks a little more
like what I expected. There are only two
 BuiltCkt1_Final.pngBuiltCkt1_TransferFunctions.png 
  1775   Wed Jul 22 11:08:36 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI have built a version of the circuit with
flying components; the completed circuit
is shown in the attached picture. I built
 BuiltCkt_Picture.pngBuiltCkt2_Final.png1stSegment.png2ndSegment_ExtraL.pngComplete_ExtraL.png 
  1787   Fri Jul 24 17:47:52 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateAfter speaking with Rana and realizing
that it would be better to use smaller inductances
in the flying-component circuit (and after
 BuiltCkt2_Picture_Simplified.pngBuiltCkt2_Simplified.pngSimplified.png 
  1804   Wed Jul 29 12:00:49 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateFor the past couple of days I have been
trying to understand and perform Koji's
method for impedance measurement using
 ImpedanceTestingPhysicalSetup.pngImpResponses.pngImpedanceTestingSetup.pngImpedanceTestingCktDiagram.png1nF.png 
  1815   Fri Jul 31 09:52:38 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI was able to make an impedance measurement
of the flying-component circuit using Koji's
 BuiltCkt2_Simplified_EOM.pngImpedanceAG4395A_with10pF.pngBuiltCkt2_Simplified_EOM_R.pngImpedanceAG4395A_withEOM.png 
  1816   Fri Jul 31 11:04:42 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI put the flying-component circuit in a
box; a photo is attached. I also measured
the impedance; it looks exactly the same
 BoxPic.pngBoxPic2.png 
  1834   Wed Aug 5 11:49:49 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI have spent the past couple of days gathering
optics and mounts so that I can observe the
modulation of the EOM attached to the circuit
 OSASetup.pngSMAPic.pngWithSMA.png 
  1835   Wed Aug 5 15:18:12 2009 StephanieUpdateGeneralMultiply Resonant EOM Update


   
        
            
 SMA.png 
  1848   Thu Aug 6 19:54:04 2009 StephanieUpdatePSLHEPAs back to normal


   
        
            
  
  1886   Tue Aug 11 14:15:28 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI was able to observe the three sets of
modulation sidebands created by the EOM +
triply resonant circuit yesterday. Quantitative
  
ELOG V3.1.3-