  6391   Fri Mar 9 11:02:56 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:

Too Many Fast Changing EPICS in New Conlog


I have been monitoring the new conlog, and it already has far too many rows.

I'm going through the list of channels to exclude in the update_channels script for the conlog that is currently running and removing them from
the monitored channels in the new conlog using the remove_channel_names file and the medm screen (we may want to just wipe out the tables
and start over after this is set properly, but for now I'm keeping them):
#-- Exclude a few uninteresting or obsolete categories
if ( $chan =~ m/^[BIJ]$/ ||
$chan =~ m/IOO-MC_PWR_IN/ ||
$chan eq "C1:PSL-FSS_SLOWDC" ||
$chan =~ m/PSL-STAT_.*_BITS/ ||
$chan =~ m/:IOO-PZTM[12]_(PIT|YAW)_BIAS$/ ||
$chan =~ m/DAQ.*_cycle/ ||
$chan =~ m/DAQ.*rtSeconds/ ||
$chan =~ m/C1:-.*/ ||
$chan =~ m/C1:SUP/ ||
$chan =~ m/C1:SP/ ||
$chan =~ m/C1:X/ ||
$chan =~ m/C1:TST/ ||
$chan =~ m/C1:RF/ ||
$chan =~ m/C1:UCT/ ||
$chan =~ m/C1:DU/ ||
$chan =~ m/C1:MCP/ ||
$chan =~ m/C1:MCS/ ||
$chan =~ m/C1:FEC/ ||
$chan =~ m/C1:PEM/ ||
$chan =~ m/C1:LSP/ ||
$chan =~ m/C1:NIO/ ||
$chan =~ m/C1:WFS/ ||
$chan =~ m/C1:ASC-WFS/ ||
$chan =~ m/C1:ASC-SP/ ||
$chan =~ m/C1:VG/ ||
$chan =~ m/C1:IOO-DOF/ ||
$chan =~ m/C1:IOO-EO/ ||
$chan =~ m/Name/ ||
$chan =~ m/DEFAULTNAME/ ||
$chan =~ m/:IOO-PZT.*OFFSET/ ||
$chan =~ m/PD_VAR$/ ||
$chan =~ m/_INMON$/ ||
$chan =~ m/_EXCMON$/ ||
$chan =~ m/_OUT16$/ ||
$chan =~ m/_OUTMON$/ ||
$chan =~ m/_OUTPUT$/ ||
$chan =~ m/_RSET$/ ||
$chan =~ m/_ALIVE$/ ||
$chan =~ m/VMon$/ ||
$chan =~ m/PDMon$/ ||
$chan =~ m/(BiasVMon|FE_PPOLL|MASTER_OVERFLOW|FSS_TIDALSET|CPU_LOAD|CDM
_STAT|State_Bits|INDCOFFSET)/ )

With these removals, only 15493 channels are being monitored now.
  6394   Fri Mar 9 15:48:56 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:

I decided to make a backup of the database and then delete it and make a new database:
 
cd ~/ryan/database_dumpMar92012
mysqldump -u root -p C1_conlog > C1_conlog.dump.Mar92012 
Note: it appears this failed the first time, thankfully this wasn't a production service yet... In the future, do not trust this backup method for important data!

Next, log into mysql as root, dump the database, remake it and grant privileges again.:
(This is saved in megatron:~/ryan/restore_database.txt
megatron:~/ryan>mysql -u root -p
Enter password:
Welcome to the MySQL monitor.  Commands end with ; or \g.
Your MySQL connection id is 174
Server version: 5.1.41-3ubuntu12.10 (Ubuntu)

Type 'help;' or '\h' for help. Type '\c' to clear the current input statement.

mysql> list databases;
ERROR 1064 (42000): You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'list databases' at line 1
mysql> list users;      ERROR 1064 (42000): You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'list users' at line 1
mysql> use C1_conlog
Reading table information for completion of table and column names
You can turn off this feature to get a quicker startup with -A

Database changed
mysql> list users;
ERROR 1064 (42000): You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'list users' at line 1
mysql> select User from mysql.user;                                             +------------------+
| User             |
+------------------+
| php              |
| C1_conlog_epics  |
| c1_conlog_epics  |
| root             |
| C1_conlog_epics  |
| c1_conlog_epics  |
| debian-sys-maint |
| root             |
| root             |
+------------------+
9 rows in set (0.00 sec)

mysql> show databases;                                                          +--------------------+
| Database           |
+--------------------+
| information_schema |
| C1_conlog          |
| mysql              |
+--------------------+
3 rows in set (0.00 sec)

mysql> drop database C1_conlog ;
Query OK, 2 rows affected (0.56 sec)

mysql> create database C1_conlog;
Query OK, 1 row affected (0.00 sec)

mysql> use C1_conlog ;
Database changed
mysql> SET SQL_MODE="NO_AUTO_VALUE_ON_ZERO";
Query OK, 0 rows affected (0.00 sec)

mysql>
mysql> CREATE TABLE `channels` (
    ->   `channel_id` mediumint(8) unsigned NOT NULL AUTO_INCREMENT,
    ->   `channel_name` varchar(60) NOT NULL,
    ->   PRIMARY KEY (`channel_id`),
    ->   UNIQUE KEY `channel_name` (`channel_name`)
    -> ) ENGINE=MyISAM  DEFAULT CHARSET=latin1;
Query OK, 0 rows affected (0.04 sec)

mysql>
mysql> CREATE TABLE `data` (
    ->   `acquire_time` decimal(26,6) NOT NULL,
    ->   `channel_id` mediumint(8) unsigned NOT NULL,
    ->   `value` varchar(40) DEFAULT NULL,
    ->   `status` tinyint(3) unsigned DEFAULT NULL,
    ->   `connected` tinyint(1) unsigned NOT NULL,
    ->   PRIMARY KEY (`channel_id`,`acquire_time`)
    -> ) ENGINE=MyISAM DEFAULT CHARSET=latin1;
Query OK, 0 rows affected (0.03 sec)

mysql> grant select, insert, update, execute on * to 'c1_conlog_epics'@'127.0.0.1';  Query OK, 0 rows affected (0.00 sec) 
mysql> grant select, insert, update, execute on * to 'C1_conlog_epics'@'127.0.0.1';   Query OK, 0 rows affected (0.00 sec) 
 mysql> grant select, insert, update, execute on * to 'c1_conlog_epics'@'localhost';  Query OK, 0 rows affected (0.00 sec) 
mysql> grant select, insert, update, execute on * to 'C1_conlog_epics'@'localhost';
Query OK, 0 rows affected (0.00 sec)

mysql> grant select on C1_conlog to 'php'@'%';
ERROR 1146 (42S02): Table 'C1_conlog.C1_conlog' doesn't exist
mysql> grant select on * to 'php'@'%';
Query OK, 0 rows affected (0.00 sec)

mysql> select * from mysql.users
    -> ;
ERROR 1146 (42S02): Table 'mysql.users' doesn't exist
mysql> select User from mysql.user;        
| C1_conlog_epics  |
| c1_conlog_epics  |
| root             |
| C1_conlog_epics  |
| c1_conlog_epics  |
| debian-sys-maint |
| root             |
| root             |
+------------------+
9 rows in set (0.00 sec)

mysql> Bye 



Next, I decided that I want to index on the acquire_time instead of the combination of channel_id and acquire_time (I think it makes a lot of sense for several query types, and especially debugging the conlog!):
mysql> create index acquire_time_index on data(acquire_time);
Query OK, 0 rows affected (0.04 sec)
Records: 0  Duplicates: 0  Warnings: 0

Next Fix:


The above worked well, but when I restarted the conlog, I had to re-execute the "remove_channels" from the medm, because initially all channels were being loaded (use_channel_names had all the channels still).
Additionally, there were a lot of channels with "*RMS*" in the name that were being recorded, and were changing relatively quickly, so I have added those to the remove_channel_names file.

I am going to: Backup the files in /ligo/caltech/data/conlog/c1
Edit use_channel_names to only have the good channels.
Dump the database again
Stop conlog.
Wipe the database again.
Remake the database again (with permissions and the new index).
Restart the conlog and hope!

The fix above seems to be in place and working. The database has the initial entries for the channels it monitors and is not growing without operators changing EPICs values.

  6396   Fri Mar 9 16:28:10 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:
I created a page on the wiki for the new EPICS log (conlog):
https://wiki-40m.ligo.caltech.edu/aLIGO%20EPICs%20log%20%28conlog%29

I also edited this with restart instructions:
https://wiki-40m.ligo.caltech.edu/Computer_Restart_Procedures#megatron
  6404   Tue Mar 13 13:28:31 2012 Ryan FisherUpdateCDSDAQ restart with new ini file
Extra note: This was the ini file that was edited:
/cvs/cds/rtcds/caltech/c1/chans/daq/C1PEM.ini
  7001   Mon Jul 23 07:39:55 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:
Note: The Conlog install instructions that I started from were located here:
https://awiki.ligo-wa.caltech.edu/aLIGO/Conlog
  5729   Mon Oct 24 17:23:14 2011 SUS_DiagonalizerUpdateSUSOptics kicked
This is a cron-elog test. No optics have been kicked.
  5766   Sun Oct 30 23:03:37 2011 SUS_DiagonalizerUpdateSUSSUS input matrix diagonalization complete (EXAMPLE)
New SUS input matrix diagonalization complete. Matrices have been written to the frontend. Summaries for each optic can be viewed below.

(THIS IS AN EXAMPLE---no new matrices have been written.)
Attachment 1: MC1.png
MC1.png
Attachment 2: MC2.png
MC2.png
Attachment 3: MC3.png
MC3.png
Attachment 4: ETMX.png
ETMX.png
Attachment 5: ETMY.png
ETMY.png
Attachment 6: ITMX.png
ITMX.png
Attachment 7: ITMY.png
ITMY.png
Attachment 8: PRM.png
PRM.png
Attachment 9: SRM.png
SRM.png
Attachment 10: BS.png
BS.png
  7523   Wed Oct 10 21:50:39 2012 SUS_DiagonalizerUpdateSUSOptics kicked
All suspended optics have been kicked at Wed Oct 10 21:50:39 PDT 2012. Watchdogs will be reengaged in 90 minutes.
  7524   Thu Oct 11 00:22:58 2012 SUS_DiagonalizerUpdateSUSOptics kicked

Quote:
All suspended optics have been kicked at Wed Oct 10 21:50:39 PDT 2012. Watchdogs will be reengaged in 90 minutes.


New SUS input matrix diagonalization complete.
  10008   Mon Jun 9 09:51:11 2014 Sai AkhilUpdateElectronicsFrequency Error Measurement of UFC-6000 RF Frequency Counter

 Motivation: 

 
To test the precision of Mini-Circuits Model UFC-6000 RF Frequency Counter which will be used for recording the beat note for the Frequency Offset Locking Loop(FOLL).
 
 
Setup:
 
Mini Circuits RF Frequency Counter Model UFC-6000 has three I/O ports:
1)REF IN,2)USB INTERFACE,3)RF IN.
The USB INTERFACE is connected to the PC(Windows/Linux) through a USB cable.
The test RF input from an SRS Function Generator(Model DS 345 with tested precision up to 1mHz)is fed in through RF IN using an SMA cable with an SMA-BNC adaptor to connect to the Function Generator.
The REF IN is open since we want to test the counter.
 
 
What I did:
 
1. First interfaced the counter with the PC with windows OS.
 
2. Installed the user friendly GUI on my Laptop so as to record the data from the counter into a .txt file.
 
3. Gave an RF input through the function generator and recorded the response of the counter for different frequencies ranging from 1MHz to 30MHz.
 
4.Analyzed the collected data by plotting the histograms(attached) in Matlab(script attached in .zip file)
 

What was Expected:
 
The measurement statistics of the instrument would give knowledge about the error and tolerance in the measurement which will be helpful to negotiate the error when the counter is being used in the setup. 
 
 
Results:
 
The obtained plots(for sampling time of 1s) are attached in a figure.
The measurement error of the frequency counter for 1s sampling time is:
 
data file     Frequency       Mean in MHz            Standard Error(+/-)in Hz    
 1MH.txt            1MHz            0.999999846             0.0109
 5MHz.txt          5MHz            5.000000293             0.0134
 10MHz.txt       10MHz         10.00000148              0.0108
 15MHz.txt       15MHz         15.0000018                0.0072
 20MHz.txt       20MHz         20.00000053              0.0259
 30MHz.txt       30MHz         30.00000146              0.0230
 
The measurement error of the UFC-6000 RF Frequency Counter is in the order of 0.01-0.02 Hz. This error varies at different frequencies as inferred from the table.
The error for different sampling times of the FC are also plotted.
 
Plan:
 
To complete interfacing the counter with the Raspberry-pi.
Make this Frequency Counter talk to EPICS through slow channels.
 
 
 
 
 
 
Attachment 1: Data_and_Script_Files.zip
Attachment 2: Error_Measurement_FC.pdf
Error_Measurement_FC.pdf
Attachment 3: Error_freq.jpg
Error_freq.jpg
  14058   Thu Jul 12 15:15:47 2018 SandrineUpdate Beat Note Measurements for Cavity Scans

(Gautam, Sandrine)

We calculated the expected power of the beat note for Annalisa's Y arm cavity scans. 

Beat Note Measurement

We began by calculating the transmitted power of the PSL and AUX. We assumed that the input power of the PSL was 25 mW and the input power of the AUX was 250 uW. We also assumed a loss of 25 ppm for the ITM and ETM. We used T1 = 0.0138 and T2 = 25 x 10-6. 

P_{t} = \frac{t _{1}^{2}t_{2}^{2}}{1+r_{1}^{2}r_{2}^{2}-2r_{1}r_{2}}

t = \sqrt{T}          

r = \sqrt{1-T-L} = {\sqrt{R}}

The transmitted power of the PSL is approximately 100 uW, and the transmitted power of the AUX is approximately 0.974 uW. 

P_{t}^{PSL} = 100 uW                          P_{t}^{AUX} = 0.974 uW

The beat note was calculated with the following:

P_{beat} = 2\sqrt{P_{PSL}P_{AUX}} = 20 uW

The  expected beat note should be approximately 20 uW. 

  14103   Wed Jul 25 14:45:59 2018 SandrineSummaryThermal CompensationETM Y Table AUX read out

Attached is a photo of the set up of the ETM Y table showing the AUX read out set up. 

Currently, the flip mount sends the AUX to the PDA255. Terra inserted a razor blade so the PDA255 will witness more HOMs. The laser is also sent to the regular PD and the CCD.

Attachment 1: EY_table_.JPG
EY_table_.JPG
  14109   Fri Jul 27 17:16:14 2018 SandrineUpdateThermal CompensationCopied working scripts for mode spectroscopy into new directory (modeSpec)

The scripts: AGfast.py, make HDF5.py, plotSpec_marconi.py, and SandrineFitv3.py were copied into the new directory modeSpec.

The path is: /opt/rtcds/caltech/c1/scripts/modeSpec

These scripts can still be found under Annalisa's directory under postVent.

  15510   Sat Aug 8 07:36:52 2020 Sanika KhadkikarConfigurationCalibration-RepairBS Seismometer - Multi-channel calibration

Summary : 

I have been working on analyzing the seismic data obtained from the 3 seismometers present in the lab. I noticed while looking at the combined time series and the gain plots of the 3 seismometers that there is some error in the calibration of the BS seismometer. The EX and the EY seismometers seem to be well-calibrated as opposed to the BS seismometer.

The calibration factors have been determined to be :

BS-X Channel: \small {\color{Blue} 2.030 \pm 0.079 }

BS-Y Channel: \small {\color{Blue} 2.840 \pm 0.177 }

BS-Z Channel: \small {\color{Blue} 1.397 \pm 0.182 }


Details :

The seismometers each have 3 channels i.e X, Y, and Z for measuring the displacements in all the 3 directions. The X channels of the three seismometers should more or less be coherent in the absence of any seismic excitation with the gain amongst all the similar channels being 1. So is the case with the Y and Z channels. After analyzing multiple datasets, it was observed that the values of all the three channels of the BS seismometer differed very significantly from their corresponding channels in the EX and the EY seismometers and they were not calibrated in the region that they were found to be coherent as well. 


Method :

Note: All the frequency domain plots that have been calculated are for a sampling rate of 32 Hz. The plots were found to be extremely coherent in a certain frequency range i.e ~0.1 Hz to 2 Hz so this frequency range is used to understand the relative calibration errors. The spread around the function is because of the error caused by coherence values differing from unity and the averages performed for the Welch function. 9 averages have been performed for the following analysis keeping in mind the needed frequency resolution(~0.01Hz) and the accuracy of the power calculated at every frequency. 

  1. I first analyzed the regions in which the similar channels were found to be coherent to have a proper gain analysis. The EY seismometer was found to be the most stable one so it has been used as a reference. I saw the coherence between similar channels of the 2 seismometers and the bode plots together. A transfer function estimator was used to analyze the relative calibration in between all 3 pairs of seismometers. In the given frequency range EX and EY have a gain of 1 so their relative calibration is proper. The relative calibration in between the BS and the EY seismometers is not proper as the resultant gain is not 1. The attached plots show the discrepancies clearly : 
  • BS-X & EY-X Transfer Function : Attachment #1
  • BS-Y & EY-Y Transfer Function : Attachment #2

          The gain in the given frequency range is ~3. The phase plotting also shows a 180-degree phase as opposed to 0 so a negative sign would also be required in the calibration factor. Thus the calibration factor for the Y channel of the BS seismometer should be around ~3. 

  • BS-Z & EY-Z Transfer Function : Attachment #3

The mean value of the gain in the given frequency range is the desired calibration factor and the error would be the mean of the error for the gain dataset chosen which is caused due to factors mentioned above.

Note: The standard error envelope plotted in the attached graphs is calculated as follows :

         1. Divide the data into n segments according to the resolution wanted for the Welch averaging to be performed later. 

         2. Calculate PSD for every segment (no averaging).

         3. Calculate the standard error for every value in the data segment by looking at distribution formed by the n number values we obtain by taking that respective value from every segment.

Discussions :

The BS seismometer is a different model than the EX and the EY seismometers which might be a major cause as to why we need special calibration for the BS seismometer while EX and EY are fine. The sign flip in the BS-Y seismometer may cause a lot of errors in future data acquisitions. The time series plots in Attachment #4 shows an evident DC offset present in the data. All of the information mentioned above indicates that there is some electrical or mechanical defect present in the seismometer and may require a reset. Kindly let me know if and when the seismometer is reset so that I can calibrate it again. 

Attachment 1: BS_X-EY_X.png
BS_X-EY_X.png
Attachment 2: BS_Y-EY_Y.png
BS_Y-EY_Y.png
Attachment 3: BS_Z-EY_Z.png
BS_Z-EY_Z.png
Attachment 4: timeseries.png
timeseries.png
  1985   Fri Sep 11 17:11:15 2009 SanjitUpdateASSOAF: progress made

[Jenne & Sanjit]

Good news: We could successfully send filtered output to MC1 @ SUS.

We used 7 channels (different combinations of 3 seismometer and six accelerometer)

We tried some values of \mu (0.001-0.005) & gain on SUS_MC1_POSITION:MCL and C1ASS_TOP_SUS_MC1 (0.1-1).

C1:ASS-TOP_SUS_MC1_INMON is huge (soon goes up to few times 10000), so ~0.1 gains at two places bring it down to a reasonable value.

Bad news: no difference between reference and filtered IOO-MC_L power spectra so far.

Plan of action: figure out the right values of the parameters (\mu, \tau, different gains, and may be some delays), to make some improvement to the spectra.

 ** Rana: there's no reason to adjust any of the MCL gains. We are not supposed to be a part of the adaptive algorithm.

  2160   Thu Oct 29 18:25:33 2009 SanjitUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen

Quote:

[Sanjit,Jenne]

Sanjit has been working today on trying to get the OAF coefficients to save properly.  Alex got us most of the way, but right now it's looking like the filter that is being saved is totally constant (all the values are the same).  We're poking around trying to figure out why this is. 

Also, we're starting again (as we should have been for the last week or so since Alex came in to help us) to check in the TOP_XFCODE whenever we make changes to it, and when we recompile the front end code. 

 

We are manually restarting assepics, but the terminal logs us out after sometime and ass may crash. I set autologout=0 in the terminal for the time being. Once the testing process is over, assepics will start automatically when the computer is turned on, so we wont have to worry about this.

(if ass crashes tonight, it is not unexpected!)

 

  2171   Mon Nov 2 21:09:15 2009 SanjitUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen

 

I made some changes in the code (all commented in the installed and SVN version) to print the filter coefficients. I got crazy output. Sometimes memory bugs lead to such crazy behavior. So far I could not find any bugs, but will have to spend more time on it.

 

  2323   Tue Nov 24 18:24:54 2009 SanjitConfigurationAdaptive FilteringASS channels added to framebuilder

 

[Sanjit, Jenne, Rob, Joe]

 

We added and tested the following channels from "/cvs/cds/gds/param/tpchn_C3.par" to "/cvs/cds/caltech/chans/daq/C1ASS.ini" appending a "_2048" extension to the channel name (as the name of a channel in .ini and .par files must be different):

[C1:ASS-TOP_CORR_IN1_2048]
[C1:ASS-TOP_ERR_EMPH_IN1_2048]
[C1:ASS-TOP_PEM_10_IN1_2048]
[C1:ASS-TOP_PEM_11_IN1_2048]
[C1:ASS-TOP_PEM_12_IN1_2048]
[C1:ASS-TOP_PEM_15_IN1_2048]
[C1:ASS-TOP_PEM_16_IN1_2048]
[C1:ASS-TOP_PEM_17_IN1_2048]
[C1:ASS-TOP_PEM_18_IN1_2048]
[C1:ASS-TOP_PEM_19_IN1_2048]
[C1:ASS-TOP_PEM_20_IN1_2048]
[C1:ASS-TOP_PEM_24_IN1_2048]
[C1:ASS-TOP_PEM_2_IN1_2048]
[C1:ASS-TOP_PEM_3_IN1_2048]
[C1:ASS-TOP_PEM_4_IN1_2048]
 

These five-line entries for each channels in the .par file were manually copy pasted from the .ini file, should think about a smarter way...

The old .par file is kept as: /cvs/cds/caltech/chans/daq/C1ASS.ini.20Nov2009

The current one is also saved as: /cvs/cds/caltech/chans/daq/C1ASS.ini.24Nov2009

And, the current one is committed to the svn.

 

NOTE: In the first attempt, the channel names were mistakenly kept the same in both the .ini and .par files and this caused DAQ daemon to crash badly. It could only be recovered by hard reboot of the frame builder.  Important info here: Jenne's elog 2316

  2555   Mon Feb 1 18:31:00 2010 SanjitUpdateAdaptive FilteringOAF details

  I tried downsampling value 32 (instead of 16), to see if it has any effect on OAF. Last week I encountered some stability issue - adaptation started to work, but the mode cleaner was suddenly unlocked, it could be due to some other effect too.

One point to note is that different downsampling did not have any effect on the CPU meter (I tried clicking the "RESET" button few times, but no change).

  2557   Mon Feb 1 21:51:12 2010 SanjitUpdateAdaptive FilteringOAF details

 I tried some combination of PEM channels and filters to improve OAF performance at other frequencies, where we do not have any improvement so far. There is progress, but still no success.

Here are the main things I tried:

For the ACC channels replaced the 0.1 Hz high pass filters by 3Hz high pass and turned off the 1: filter.

Then I tried to incorporate the Z ACC/GUR channels, with some reasonable combination of the others.

The Z axis Guralp and Accelerometers were making OAF unstable, so I put a 0.1 gain in all four of those.

Following the PEM  noise curves Rana has put up, we should probably use

  • two ACC_Y channels (3:0, Notch24, AA32)
  • two GUR_Z channels (filters: 0.1:0, 1:, AA32, gain 0,1)
  • one RANGER_Y, just because it works (0.1:0, 1:, Notch24, AA32)

In the end I tried this combination, it was stable after I reduced the GUR_Z gain, but looked very similar to what we got before, no improvement at 5Hz or 0.5Hz. But there was a stable hint of better performance at > 40Hz.

Possibly we need to increase the GUR_Z gain (but not 1) and try to use ACC_Z channels also. Since we can not handle many channels, possibly using one GUR_Z and one ACC_Z would be worth checking.

  2571   Fri Feb 5 00:52:55 2010 SanjitUpdateAdaptive FilteringOAF at 0.1-1.0 Hz

 

At 0.1-1.0Hz, there is some coherence between MC_L and RANGER_Y & GUR_Y, see the first figure. Also GUR_Z has low noise there. So I used all five of them, increased the gains of GUR_Z from 0.1 to 0.5. Some improvement near 0.5Hz. We possibly can not do any better with these PEM measurement, as the coherence of the adapted error signal and the PEM channels is almost zero, see the second figure. May be we need to think about placing the seismometers at different places/orientations.

However, there is lot more scope at higher frequencies, lot of coherence at 5-100Hz.

 

Attachment 1: OAF_04FEB2010_noOAF.png
OAF_04FEB2010_noOAF.png
Attachment 2: OAF_04FEB2010.png
OAF_04FEB2010.png
  2572   Fri Feb 5 01:04:58 2010 SanjitUpdateAdaptive FilteringOAF at > 5Hz

 

There is lot of coherence between the error signal and PEM channels at 5-100Hz. We had been applying a 1Hz low pass filter to all the GUR and RANGER channels for stability. I turned those off and OAF still works with mu=0.0025, this will give us some more freedom. Kind of annoying for testing though, it takes about 45min to adapt!

In any case, there is no significant improvement at high frequencies as compared to our usual OAF performance. Also, the low frequency improvement (see previous e-log) is lost in this set up. I think, we have to adjust the number of taps and channels to do better at high frequencies. Also, delay can be important at these frequencies, needs some testing.

 

Attachment 1: OAF_04FEB2010_highFreq.png
OAF_04FEB2010_highFreq.png
  2575   Sat Feb 6 00:10:08 2010 SanjitUpdateAdaptive FilteringOAF at > 5Hz

 

Did some more test to get better performance at higher frequencies.

Increased # taps to 4000 and reduced downsampling to 4, without changing the AA32 filters, from CORR, EMPH and the matching ADPT channels. But for testing I turned off AA32 from the input PEM channels. So that high frequency still gets blocked at CORR, but the adaptive filters have access to higher frequencies. Once we fix some reasonable downsampling, we should create corresponding AA filters.

I used only two channels, RANGER/GUR2_Y and GUR1_Z, and basically they had only one filter 0.1:0

This set up gave little better performance (more reduction at more frequencies), at some point even the 16HZ peak was reduced by a factor of 3. The 24Hz peak was a bit unstable, but became stable after I removed the Notch24 filters from PEM channels, to ensure that OAF is aware of those lines. There was some improvement also at the 24Hz peak.

 

  2121   Mon Oct 19 19:37:39 2009 Sanjit, JenneUpdateAdaptive Filteringextra delay and noise in PEM -> ASS/OAF system

Rana pointed out that the delay may be caused by the 110B DAQ, as it integrates over 2ms (5 clock cycles at 2048Hz on the fe computer), to make low noise measurement. However, the C0DCU knows about this delay and corrects it by fudging the time stamp, before sending it to the frame builder, so that the time stamps match the actual measurement time. But, the ASS computer is not aware of such an integration time, so it does not adjust the time. We verified that it is indeed the case. This is what we did (as suggested by Rana):

We split the signal from the MODE cleaner board "OUT" port using a T-splitter to the original PENTEK board (C1:SUS-MC2-MCL-IN) and the PEM ADCU channel #2. Then measured the mutual delays between the signals that are processed by C0DCU and the ASS computer for both the MC_L signal and the corresponding output through the PEM channel. We clearly see the same delay (compare red and brown in the bottom panel) between the signals that are going through 110B and the PENTEK DAQ. This delay is a bit noisy, possibly because the PENTEK is not as low noise as the 110B is.

There is some delay (pink curve in the bottom panel) between the PENTEK DAQ and the frame builder corrected 110B output, much smaller than 2ms, could be ~200-400 u sec. Which should correspond to the 1 or 1/2 cycle delay caused by the PENTEK DAQ.

So, once we have the planned advLIGO DAQ system, there should not be any long delay. Perhaps, to solve the problem and make OAF functional soon, we will upgrade the PEM DAQ asap, rather than waiting for the rest of the upgrades...

 

Attachment 1: PEM_timingDealy_19OCT09_MCL2PEM2.png
PEM_timingDealy_19OCT09_MCL2PEM2.png
  2199   Fri Nov 6 19:25:31 2009 Sanjit, Jenne, JoeUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen

Quote:

 I made some changes in the code (all commented in the installed and SVN version) to print the filter coefficients. I got crazy output. Sometimes memory bugs lead to such crazy behavior. So far I could not find any bugs, but will have to spend more time on it 

 

Something strange was going on in the OAF code, printf would print a double precision number in %f format but not in %lf or %e format!

Since we know this problem now, we can move forward, but it will be important to know why printf was restricted and if there are other such constraints which we should remember while making changes in the codes.

 

  2447   Tue Dec 22 18:42:40 2009 Sanjit, KojiConfigurationAdaptive FilteringReadded DAQ channels to active list

Sometimes back we modified /cvs/cds/caltech/chans/daq/C1ASS.ini to save some of the channels. The file was reverted to default after the recent changes in ASS.

We again uncommented and made acquire=1 to save the following three channels using daqconfig:

C1:ASS-TOP_ERR_MCL_IN1_2048

C1:ASS-TOP_PEM_15_IN1_2048

C1:ASS-TOP_PEM_18_IN1_2048

The script automatically created a back up in /cvs/cds/caltech/chans/daq/archive

 

  3517   Thu Sep 2 21:22:31 2010 Sanjit, KojiConfigurationComputersrossa nvidia driver and dual monitor configuration

 

Simple steps (but don't try these on a working computer without getting some experience on a spare one, you may find it difficult to restore the system if something goes wrong):

  1. download the appropriate driver from NVIDIA website for this computer
    • we did: NVIDIA GeForce 310 64bit Linux, version: 256.53, release date 2010.08.31
  2. keep/move the driver in /root (use "sudo" or "su")
  3. reboot the computer in "single user" mode
    • in the GRUB screen edit the boot command by pressing the appropriate key listed in the screen
    • in the boot command-line put " single" in the end (no other change is normally needed), don't save
    • press ENTER and the system will reboot to a root shell (# prompt)
  4. cd /root
  5. run the NVIDIA driver script
  6. exit the shell (ctrl-d), let the system reboot
    • it should flash (mostly green) "nvidia" screen before starting X
    • in case of problems run system-config-display and revert to vesa driver
  7. login as "root" and run "nvidia-settings" from command line or GUI menu to add/configure display

 

  2516   Fri Jan 15 12:04:26 2010 Sanjit, mevansUpdateAdaptive FilteringCanceling noise again!

 

OAF is successfully canceling noise again, thanks to Matt!

Here is a plot showing more than a factor of 10 noise reduction around 3Hz (similar to what we saw in the simulations)

The changes that has made it work are:

  • use of RANGER channel (with ACC_MC1_X and/or ACC_MC2_X)
  • mu = 0.01, tau = 1.0e-6, ntaps = 2000, nDown = 16
  • nDelay = 5 and nDelay = 7 both work (may not be so sensitive on delay at low frequencies)
  • Main changes: filter bank on the PEM channels (ASS_TOP_PEM_## filters: 0.1:0, 1:, Notch24, AA32)
  • Added the AI800 filter for upsampling in MC1 (should not matter)

 Matt suggested playing with the emphasis (EMPH) filters to cancel noise in different frequency bands.

 

Attachment 1: OAF_15JAN2010.png
OAF_15JAN2010.png
  2548   Tue Jan 26 19:51:44 2010 Sanjit, ranaUpdateAdaptive FilteringOAF details

We turned on the OAF again to make sure it works. We got it to work well with the Ranger as well as the Guralp channels. The previous problem with the ACC is that Sanjit and Matt were using the "X" channels which are aligned the "Y" arm. Another casualty of our ridiculous and nonsensical coordinate system. Long live the Right Hand Rule!!

The changes that were made are:

  • use of RANGER channel (with ACC_MC1_X and/or ACC_MC2_X)
  • mu = 0.01, tau = 1.0e-6, ntaps = 2000, nDown = 16
  • nDelay = 5 and nDelay = 7 both work (may not be so sensitive on delay at low frequencies)
  • Main changes: filter bank on the PEM channels - ASS_TOP_PEM_## filters: 0.1:0, 1:, Notch24, AA32, gain 1
  • Added the AI800 filter for upsampling in MC1 (should not matter)

Other parameters which were kept at usual setting:

  • CORR: AI32, gain = 1
  • EMPH: 0.001:0, AA32, gain = 1
  • ERR_MCL: no filters, gain = 1
  • SUS_MC1: no filter, gain = 1
  • PEM Matrix: All zero except: (24,1), (15,2), (18,3)
  • ADAPT path filter: union of CORR and EMPH filters, gain 1
  • XYCOM switches # 16-19 (last four on the right) OFF 

Screenshots are attached.

Burt snapshot is kept as: /cvs/cds/caltech/scripts/OAF/snaps/ass_burt_100126_211330.snap

taken using the script: /cvs/cds/caltech/scripts/OAF/saveOAF

we should put this in ASS screen.


ERROR Detected in filter ASS_TOP_PEM_24 (RANGER): 1: was actually typed as a 1Hz high pass filter!

(Correcting this one seems to spoil the adaptation)

Possibly this makes sense, we may not want to block witness signals in the 0.1-20 Hz range.


  11:40 PM: Leaving the lab with the OAF running on 5 PEM channels (Ranger + Guralp 1&2  Y & Z). There's a terminal open on op440m which will disable the OAF in ~2.8 hours. Feel free to disable sooner if you need the MC/IFO.

Attachment 1: C1ASS_TOP.png
C1ASS_TOP.png
Attachment 2: C1SUS_SRM_XYCOM1.png
C1SUS_SRM_XYCOM1.png
Attachment 3: Untitled.png
Untitled.png
  6880   Wed Jun 27 11:35:06 2012 SashaSummaryComputer Scripts / ProgramsSURF - Week 1 - Summary

I started playing with matlab for the first time, accurately simulated a coupled harmonic oscillator (starting from the basic differential equations, if anyone's curious), wrote a program to get a bode plot out of any simulation (regardless of the number of inputs/outputs), and read a lot.

I'm currently going through the first stage of simulating an ideal Fabry-Perot cavity (I technically started yesterday, but yesterday's work turned out to be wrong, so fresh start!), and other than yesterday's setback, its going okay.

I attached a screenshot of my simulation of the pitch/pendulum motion of one of the mirrors LIGO uses. The bode plots for this one are turning out a little weird, but I'm fairly certain its just a computational error and can be ignored (as the simulation matlab rendered without the coupling was really accurate - down to a floating point error). I have also attached these bode plots. The first bode is based on the force input, while the second is based on the torque input. It makes sense that there are two resonant frequencies, since there ought to be one per input.

 

Attachment 1: Screen_Shot_2012-06-27_at_11.27.10_AM.png
Screen_Shot_2012-06-27_at_11.27.10_AM.png
Attachment 2: Screen_Shot_2012-06-27_at_11.26.57_AM.png
Screen_Shot_2012-06-27_at_11.26.57_AM.png
Attachment 3: Screen_Shot_2012-06-27_at_11.27.29_AM.png
Screen_Shot_2012-06-27_at_11.27.29_AM.png
  6957   Wed Jul 11 10:17:18 2012 SashaSummarySimulationsSURF - Week 2 and 3 - Summary

These past two weeks, I've been working on simulating a basic Fabry-Perot cavity.  I finished up a simulation involving static, non-suspension mirrors last week. It was supposed to output the electric field in the cavities given a certain shaking (of the mirrors), and the interesting thing was that it outputted the real and imaginary components seperately, so I ended up with six different bode plots. Since we're only interested in the real part, bodes 2, 4, and 6 can be discarded (see attachment 1). There was a LOT of split-peak behavior, and I think it has to do either with matlab overloading or with the modes of the cavity being very close together (I actually think the first is more likely since a smaller value of T_1 resulted in actual peaks instead of split ones).

At any rate, there really wasn't much I could improve on that simulation (neither was there any point), but I attach the subsystem governing the electric field in the cavity as a matter of academic interest (see attachment 2). So I moved onto simulations where the mirrors are actually suspended pendulums as they are in reality.

 

A basic simulation of the suspended mirrors gave me fairly good results (see attachment 3). A negative Q resulted in a phase flip, detuning the resonance from the wrong side resulted in a complete loss of the resonance peak, and the peak looked fairly consistent with what it should be. The simulation itself is pretty bare bones, and relies on the two transfer functions P(s) and K(s); P(s) is the transfer function for translating the force of the shaking of the two test masses (lumped together into one transfer function) into actual displacement. Note that s = i*w, where w is the frequency of the force being applied. K(s), on the other hand, is the transfer function that feeds displacement back into the original applied force-based shaking. Like I said, pretty bare bones, but working (see attachment 4 for a bode plot of a standard detuning value and positive Q). Tweaking the restoring (or anti restoring, depending on the sign of the detuning) force constant (K_0 for short) results in some interesting behavior. The most realistic results are produced for K_0 = 1e4, when the gain is much lower overall but the peak in resonance gets you a gain of 100 in dB.  For those curious as to where I got P(s) and K(s), see "Measurement of radiation-pressure-induced optomechanical dynamics in a suspended Fabry-Perot cavity" by Thomas Corbitt, et. al.

I'm currently working on a more realistic simulation, with frequency and force noise as well as electronic feedback (via transfer functions, see attachment 5). The biggest thing so far has been trying to get the electronic transfer functions right. Corbitt's group gave some really interesting transfer functions (H_f(s) and H_l(s) for short; H_f(s) gives the frequency-based electronic transfer function, while H_l(s) gives the length-based electronic transfer function), which I've been trying to copy so that I can reproduce their results (see attachment 6). It looks like H_l(s) is a lowpass Butterworth filter, while H_f(s) is a Bessel filter (order TBD). Once that is successful, I'll figure out what H_f(s) and H_l(s) are for us (they might be the same!), add in degrees of freedom, and my first shot at the OSEM system of figuring out where the mirror's position is.

 

Attachment 1: Screen_Shot_2012-07-11_at_9.44.34_AM.png
Screen_Shot_2012-07-11_at_9.44.34_AM.png
Attachment 2: Screen_Shot_2012-07-05_at_2.15.33_PM.png
Screen_Shot_2012-07-05_at_2.15.33_PM.png
Attachment 3: Screen_Shot_2012-07-11_at_9.56.27_AM.png
Screen_Shot_2012-07-11_at_9.56.27_AM.png
Attachment 4: Screen_Shot_2012-07-11_at_9.56.15_AM.png
Screen_Shot_2012-07-11_at_9.56.15_AM.png
Attachment 5: Screen_Shot_2012-07-11_at_10.12.15_AM.png
Screen_Shot_2012-07-11_at_10.12.15_AM.png
Attachment 6: Screen_Shot_2012-07-11_at_10.09.13_AM.png
Screen_Shot_2012-07-11_at_10.09.13_AM.png
  6985   Wed Jul 18 09:53:20 2012 SashaSummarySimulationsSURF - Week 4 - Summary

This past week, I've been working on moving forward with the basic cavity model I developed last week (for future reference, that model was FP_3, and I am now working on FP_4) and refining the suspensions. I added three degrees of freedom to my simulation (such that it now consists of yaw, pitch, displacement, and side-to-side motion) and am attempting to integrate them with the OSEMS. I have also added mechanical damping for all degrees of freedom, and am adding electric damping and feedback. Concerning that, are all of the degrees of freedom locally damped in addition to being actuated on by the control system? Or does the control system do all of the damping itself? The first is the way I'm working on setting it up, but can easily change this if needed.

The next iteration of FP (FP_5) will replace my complicated OSEM --> Degrees of Freedom and vice versa system with the matrix system (see the poster Jenne and Jamie made, "Advanced Suspension Diagnostic Procedure"), as well as adding bounce/roll, yaw/y coupling, various non-damping filters as needed (i.e. the a2f filters), and noise sources. However, I'll only move on to that once I'm sure I have FP_4 working reasonably well. For now at least, the inputs/outputs look fine, and some of the DOF show resonance peaks. I'll become more concerned about where these resonance peaks actually are once I add damping.

Attached is a screenshot my work in progress. Only one of the suspensions has a basic feedback/damping loop going (as a prototype). It looks complicated now, but will simplify dramatically once I have damping worked out. Pink inputs are noises (will probably replace those with noise generators in FP_5) and green inputs are the OSEMS. The red output is the displacement of the cavity from resonance. The blue boxes are suspensions.

Attachment 1: Screen_Shot_2012-07-18_at_9.50.26_AM.png
Screen_Shot_2012-07-18_at_9.50.26_AM.png
  7022   Wed Jul 25 10:31:33 2012 SashaSummarySimulationsSURF - Week 5 - Summary

This week I've been working on refining my simulation and getting it ready to be plugged into the control system. In particular, I've added a first attempt at a PDH control system, matrix conversion from OSEMs to DOF and back, and all necessary DAC/ADC/AA/AI/whitening/dewhitening filters. Most of these work well, but the whitening filters have been giving me trouble. At one point, they were amplifying the signal instead of flatting it out, such that my simulation started outputting NaN (again).

This was wholeheartedly depressing, but switching out the whitening filters for flat ones seemed to make the problem go away, but brought another problem to light. The output to input ratio is minuscule (as in 10^-300/10^243, see Attachment 3 for the resulting bode plot between a force on the suspension pt in the x-direction and my two outputs - error signal and length signal, which is pretty much what you would expect it to be). I suspect that its related to the whitening filter problem (perhaps the dewhitening filter is flattening the signal instead of amplifying?). If that is the case, then switching the whitening/dewhitening filters ought to work. I'll try today and see what happens. The white/dewhite filters together result in a total gain of 1, which is a good fundamental test, but could mean absolutely nothing (i.e. they could both be wrong!). Judging from the fact that we want to flatten out low frequency signal when it goes through the whitening filter, the filters don't look switched (see Attachment 4 for a bode plot of white and dewhite).

The only other source of problems (given that the suspensions/local damping have been debugged extensively throughout this process - though they could bug out in conjunction with the cavity controls?) is the PDH system. However, separating each of the components showed that the error signal generated is not absurd (I haven't tested whether it makes sense or not, but at any rate it doesn't result in an output on the order of 10^-300).

In summary, I've made progress this week, but there is still far to go. Attachment 1 is my simulation from last week, Attachment 2 is my simulation from this week. A talk with Jamie about the "big picture" behind my project helped tremendously.

Attachment 1: Screen_Shot_2012-07-24_at_10.46.05_AM.png
Screen_Shot_2012-07-24_at_10.46.05_AM.png
Attachment 2: Screen_Shot_2012-07-24_at_10.45.43_AM.png
Screen_Shot_2012-07-24_at_10.45.43_AM.png
Attachment 3: Screen_Shot_2012-07-25_at_10.16.58_AM.png
Screen_Shot_2012-07-25_at_10.16.58_AM.png
Attachment 4: Screen_Shot_2012-07-25_at_10.25.27_AM.png
Screen_Shot_2012-07-25_at_10.25.27_AM.png
  7028   Wed Jul 25 14:35:45 2012 SashaSummarySimulationsSURF - Week 5 - Summary

Quote:

This week I've been working on refining my simulation and getting it ready to be plugged into the control system. In particular, I've added a first attempt at a PDH control system, matrix conversion from OSEMs to DOF and back, and all necessary DAC/ADC/AA/AI/whitening/dewhitening filters. Most of these work well, but the whitening filters have been giving me trouble. At one point, they were amplifying the signal instead of flatting it out, such that my simulation started outputting NaN (again).

This was wholeheartedly depressing, but switching out the whitening filters for flat ones seemed to make the problem go away, but brought another problem to light. The output to input ratio is minuscule (as in 10^-300/10^243, see Attachment 3 for the resulting bode plot between a force on the suspension pt in the x-direction and my two outputs - error signal and length signal, which is pretty much what you would expect it to be). I suspect that its related to the whitening filter problem (perhaps the dewhitening filter is flattening the signal instead of amplifying?). If that is the case, then switching the whitening/dewhitening filters ought to work. I'll try today and see what happens. The white/dewhite filters together result in a total gain of 1, which is a good fundamental test, but could mean absolutely nothing (i.e. they could both be wrong!). Judging from the fact that we want to flatten out low frequency signal when it goes through the whitening filter, the filters don't look switched (see Attachment 4 for a bode plot of white and dewhite).

The only other source of problems (given that the suspensions/local damping have been debugged extensively throughout this process - though they could bug out in conjunction with the cavity controls?) is the PDH system. However, separating each of the components showed that the error signal generated is not absurd (I haven't tested whether it makes sense or not, but at any rate it doesn't result in an output on the order of 10^-300).

In summary, I've made progress this week, but there is still far to go. Attachment 1 is my simulation from last week, Attachment 2 is my simulation from this week. A talk with Jamie about the "big picture" behind my project helped tremendously.

 Here's a screenshot of what's going on inside the cavity (Attachment 1). The PDH/mixer system outputs 0 for pretty much everything except really high numbers, which is the problem I'm trying to solve now. I assumed that the sidebands were anti-resonant, calculated reflection coefficient F(dL) = Z * 4pi * i/(lambda), where Z = (-r_1 + r_2*(r_1^2 + t_1^2)/(1 - r_1*r_3)), then calculated P_ref = 2*P_s - 4sqrt(P_c*P_s) * Im(F(dL)) * sin(12.5 MHz * t) (this is pictured in Attachment 2), then mixed it with a sin(12.5MHz * t) and low-passed it to get rid of everything but the DC term (this is pictured in Attachment 3), which is the term that then gets whitened/anti-aliased/passed through the loop.

 

Attachment 1: Screen_Shot_2012-07-25_at_2.20.01_PM.png
Screen_Shot_2012-07-25_at_2.20.01_PM.png
Attachment 2: Screen_Shot_2012-07-25_at_2.20.15_PM.png
Screen_Shot_2012-07-25_at_2.20.15_PM.png
Attachment 3: Screen_Shot_2012-07-25_at_2.20.29_PM.png
Screen_Shot_2012-07-25_at_2.20.29_PM.png
Attachment 4: Screen_Shot_2012-07-25_at_2.23.05_PM.png
Screen_Shot_2012-07-25_at_2.23.05_PM.png
  7065   Wed Aug 1 10:45:38 2012 SashaSummarySimulationsSURF - Week 6 - Summary

This week, I worked on transferring my Simulink simulation to the RCG. I made all relevant library parts, now under "SASHA library" in the main Simulink library browser. My main concern has been noises - I've added some rudimentry shot noise, amplitude noise, phase noise, and intensity noise. I have yet to add local oscillator noise, and plan to upgrade the existing noises to actually have the PSD they should (using equations from Rana's and Robb Ward's theses). I'm fairly certain this can be achieved by applying the correct transfer function to white noise (a technique I learned from Masha this week!), so the RCG should be able to handle it (theoretically).

I've also been tweaking my main simulation. After a brief (but scary) attempt at adding optical levers, I decided to shelve it in order to focus on noises/RCG simulating. This is not permanent, and I plan to return to them at some point this week or next. My main problem with them was that I knew how to get from optical lever input to pitch/yaw, but had no idea how to get from pitch/yaw to optical lever input. If I had a complete basis for one in terms of the other, I'd be able to, but I don't think this is the way to go. I'm sure there is a good way to do it (it was done SOMEHOW in the original simulation of the suspensions), I just don't know it yet.

In the aftermath of the optical lever semi-disaster, my simulation is once again not really outputting anything, but since it actually worked before adding the optical levers, I'm pretty sure I can get it to work again (this is why its important to use either git or BACKUPS, >.< (or both)).

We also wrote our progress reports this week. Mine includes some discussion on the basics of cavities/the mechanics of the suspensions/brief intro to PDH, and I'll add a section on noises in the next draft. Maybe this'll be of some use to someone someday? One can only hope.

 

 

  7076   Thu Aug 2 03:06:57 2012 SashaUpdateSimulationsLS Plant (LSP) is officially ONLINE

My ls plant compiled!! The RCG code can now be found in /opt/rtcds/rtscore/tags/advLigoRTS-2.5. I uploaded a copy of c1lsp.mdl onto the svn.

The weird "failed to connect" error was due to the fact that I named my inputs the same thing as my goto/from tags, so the RCG got confused. Once I renamed my inputs, it worked! I'm not sure what happened to the original "not enough parts" error; it didn't appear a single time during the rebuilding process. Anyway, I made the PDH block much neater, though the lines between PDH and ADC are looking wonky (this is purely an aesthetic problem, not a "oh god my simulation will DIE right now if I don't fix it" problem). I'll fix it in the morning; screenshot attached!

The original c1lsp was kind of sad. I updated it extensively and brought it into the modern era with color. The original c1lsp.mdl should also be on the svn. Tommorow, I'll get started on figuring out how to get LIGO specific noises from white noise.

Attachment 1: Screenshot-1.png
Screenshot-1.png
  7116   Wed Aug 8 11:16:06 2012 SashaSummarySimulationsSURF - Week 7 - Summary

This week, I brought my c1lsp model online and fixed up some the medm screens for c1spx. Along the way, I ran into a few interesting problems (and learned a bit about bash scripting and emacs! :D). The screens for the main TM_RESP matrix are not generating automatically, and the medm screens don't want to link to the channels, for some reason. I don't have this problem with the other matrices (i.e. C2DOF and SEN_OUT), so I think it has something to do with TM_RESP being a filter matrix (which the others are not). In addition, the noise overview medm screens for c1spx are practically nonexistent - someone just copied the file for the SUS-ETMX screens into the master directory for c1spx, so they need a complete overhaul. I am willing to do this, but Jamie told me to focus my attentions elsewhere.

So I went back to noise generation. I've been using Matlab to figure out how to recreate the various noise sources (laser amplitude noise, local oscillator phase/amplitude noise, and 60 Hz/ADC. Frequency noise will be added some time this week and seismic noise should be already covered in Jamie's suspension model) in my c1lsp model. I'm doing it the way the RCG does it - by applying a filter to white noise. I'm generating white noise by just using a random number generator and pwelch-ing it to get the power spectral density.

For the filters themselves, I picked z, p, k such that it shaped the white noise PSD to look like the PSD of the noise in question. This was fairly straightforward once I figured out how zeroes and poles affected PSD. Once I'd picked zpk, I applied a bilinear transform to get a discrete zpk out, then converted to a second order section to make computation faster. I then applied that to the white noise (matlab has a convenient "sosfilt" function) and pwelch-ed/graphed it to get the result.

Attached is my attempt at filtering white noise to look like 60 Hz. noise. I can't seem to find a way to pick z and p such that the peak is more narrow (i.e. other than having two complex conjugated poles at 60 Hz.). I took the spectrum of 60 Hz. noise from a terminated ADC channel (Masha kindly let me borrow one of her GURALP channels).

EDIT: I also remembered that I've been looking for how to get a good power spectrum for the rest of the noises. Jenne referred me to Kiwamu's work on this, and I'm mostly going off elog #6133. If you have any other good elogs/data on noises, please feel free to send them my way.

I then measured the PSD of the sensors on the real suspended optics and a PSD of the suspension model. It looks like the OSEMs on the suspension model are only reading white noise, which probably means a lost connection somewhere (Attachment 2 is what the model SHOULD produce, Attachment 3 is what the model ACTUALLY produces). I perused Jamie's model, but couldn't find anything. Not sure where else to check, but I'll continue thinking about it/trying to fix it.

Attachment 1: Screen_Shot_2012-08-06_at_9.20.02_PM.png
Screen_Shot_2012-08-06_at_9.20.02_PM.png
Attachment 2: Screen_Shot_2012-08-08_at_11.13.55_AM.png
Screen_Shot_2012-08-08_at_11.13.55_AM.png
Attachment 3: Screen_Shot_2012-08-08_at_11.08.23_AM.png
Screen_Shot_2012-08-08_at_11.08.23_AM.png
  7132   Thu Aug 9 04:26:51 2012 SashaUpdateSimulationsAll c1spx screens working

As the subject states, all screens are working (including the noise screens), so we can keep track of everything in our model! :D I figured out that I was just getting nonsense (i.e. white noise) out of the sim plant cause the filter matrix (TM_RESP) that controlled the response of the optics to a force (i.e. outputted the position of the optic DOF given a force on that DOF and a force on the suspension point) was empty, so it was just passing on whatever values it got based on the coefficients of the matrix without DOING anything to them. In effect, all we had was a feedback loop without any mechanics.

I've been working on getting the mechanics of the suspensions into a filter/transfer function form; I added something resembling that into foton and turned the resulting filter on using the shiny new MEDM screens. However, the transfer functions are a tad wonky (particularly the one for pitch), so I shall continue working on them. It had a dramatic effect on the power spectrum (i.e. it looks a lot more like it should), but it still looks weird.

Still haven't found the e-log Jamie and Rana referred me to, concerning the injection of seismic noise into the simulation. I'm not terribly worried though, and will continue looking in the morning. Worst case scenario, I'll use the filters Masha made at the beginning of the summer.

Masha and I ate some of Jamie's popcorn. It was good.

  7133   Thu Aug 9 07:24:58 2012 SashaUpdateSimulationsAll c1spx screens working

Quote:

As the subject states, all screens are working (including the noise screens), so we can keep track of everything in our model! :D I figured out that I was just getting nonsense (i.e. white noise) out of the sim plant cause the filter matrix (TM_RESP) that controlled the response of the optics to a force (i.e. outputted the position of the optic DOF given a force on that DOF and a force on the suspension point) was empty, so it was just passing on whatever values it got based on the coefficients of the matrix without DOING anything to them. In effect, all we had was a feedback loop without any mechanics.

I've been working on getting the mechanics of the suspensions into a filter/transfer function form; I added something resembling that into foton and turned the resulting filter on using the shiny new MEDM screens. However, the transfer functions are a tad wonky (particularly the one for pitch), so I shall continue working on them. It had a dramatic effect on the power spectrum (i.e. it looks a lot more like it should), but it still looks weird.

Still haven't found the e-log Jamie and Rana referred me to, concerning the injection of seismic noise into the simulation. I'm not terribly worried though, and will continue looking in the morning. Worst case scenario, I'll use the filters Masha made at the beginning of the summer.

Masha and I ate some of Jamie's popcorn. It was good.

 Okay! Attached are two power spectra. The first is a power spectrum of reality, the second is a power spectrum of the simPlant. Its looking much better (as in, no longer obviously white noise!), but there seems to be a gain problem somewhere (and it doesn't have seismic noise). I'll see if I can fix the first problem then move on to trying to find the seismic noise filters.

Attachment 1: Screenshot.png
Screenshot.png
Attachment 2: Screenshot-1.png
Screenshot-1.png
  7141   Fri Aug 10 11:00:52 2012 SashaUpdateSimulationsMessing with ETMX

I've been trying to get the simPlant model to work, and my main method of testing is switching between the real ETMX and the simulated ETMX and comparing the resulting power spectrum (the closer the two are, the more our simulation works). While the simPlant is on, ETMX is NOT BEING DAMPED. I started this ~Wednesday, and the testing will continue today, then hopefully we'll get a similiar simPlant up for ITMX (at which point, testing will continue for both ITMX and ETMX).

TL;DR: ETMX is not being continuously damped, XARM will likely be exhibiting some wonky behavior next week.

  7151   Sat Aug 11 01:10:26 2012 SashaUpdateSimulationsSim_Plant Working!

Sim_Plant going okay. Adding seismic noise tomorrow - we'll see what happens. The gain is still semi-off, but I know how to fix it - its just nice to have it gained up while I play with noise.

P.S. JAMIE DO YOU NOTICE HOW PRETTY MY GRAPH IS?

Attachment 1: Plant_sen.jpg
Plant_sen.jpg
  7152   Sat Aug 11 18:05:49 2012 SashaUpdateSimulationsSim_Plant Working!

Quote:

Sim_Plant going okay. Adding seismic noise tomorrow - we'll see what happens. The gain is still semi-off, but I know how to fix it - its just nice to have it gained up while I play with noise.

P.S. JAMIE DO YOU NOTICE HOW PRETTY MY GRAPH IS?

Developed some seismic noise. I adapted the seismic noise filters we used for the MC model way back when.  They looked questionable to begin with, but I added some poles/zeroes to make it more accurate (see Attached).

Attachment 1: seismic_noise1.jpg
seismic_noise1.jpg
  7181   Tue Aug 14 16:33:51 2012 SashaUpdateComputer Scripts / ProgramsSimPlant indicator added

I added an indicator to the watch dog screen so that a little "SP" icon appears whenever the SimPlant is on. Since we only have one simplant (ETMX), only ETMX has the simPlant indicator. However, since assymetry is ugly, I moved all of the OL icons over so that they're in a line and so that there is room for future SP icons.

I also fixed the link to the Watchdogs on the main SUS screens (it was dead, but now it is ALIVE).

  7212   Fri Aug 17 04:13:45 2012 SashaUpdateSimulationsThe SimPlant Saga CONTINUES

THE GOOD: SimPlants ITMX and ETMX are officially ONLINE. Damping has been instituted in both, with varying degrees of success (see Attachment 1). An overview screen for the SimPlants is up (under XARM_Overview in the sitemap - you can ignore the seperate screens for ETMX and ITMX for now, I'll remove them later), C1LSP will be online/functional by Monday.

The super high low-frequency noise in my simPlant is from seismic noise and having a DC response of 1, so that the seismic noise at low frequencies is just passed as is and then amplified along with everything else in the m --> counts conversion. Not quite sure how to deal with this except by NOT having a DC response of 1 (which it technically doesn't have when you do the algebra - Rana said that "it made sense" for the optic to have unity gain at low frequencies, but the behavior is not matching up with reality).

THE BAD: It looks like the ITMX Switch from Reality to simPlant doesn't work (or some of the signals aren't getting switched). When switching from reality to simulation, it looks like the control system is receiving signals from the SimPlant, but is transmitting them to the real thing. As a result, when you flip the switch from reality to sim, ITMX goes seriously crazy and starts slamming back and forth against the stop. REALLY NOT GOOD. As soon as I saw what was going on, I turned back to reality and flipped the watch dogs on (YES THEY WERE OFF). I'll investigate the connections between the plant and control system some more in the morning (i.e. later today) (this is also probably what is causing the "lost connections" in c1sup/sus we can see in the machine status screen).

Attachment 1: plantvreality.jpg
plantvreality.jpg
  7218   Fri Aug 17 12:47:30 2012 SashaUpdateSimulationsThe SimPlant Saga CONTINUES

Quote:

THE GOOD: SimPlants ITMX and ETMX are officially ONLINE. Damping has been instituted in both, with varying degrees of success (see Attachment 1). An overview screen for the SimPlants is up (under XARM_Overview in the sitemap - you can ignore the seperate screens for ETMX and ITMX for now, I'll remove them later), C1LSP will be online/functional by Monday.

The super high low-frequency noise in my simPlant is from seismic noise and having a DC response of 1, so that the seismic noise at low frequencies is just passed as is and then amplified along with everything else in the m --> counts conversion. Not quite sure how to deal with this except by NOT having a DC response of 1 (which it technically doesn't have when you do the algebra - Rana said that "it made sense" for the optic to have unity gain at low frequencies, but the behavior is not matching up with reality).

THE BAD: It looks like the ITMX Switch from Reality to simPlant doesn't work (or some of the signals aren't getting switched). When switching from reality to simulation, it looks like the control system is receiving signals from the SimPlant, but is transmitting them to the real thing. As a result, when you flip the switch from reality to sim, ITMX goes seriously crazy and starts slamming back and forth against the stop. REALLY NOT GOOD. As soon as I saw what was going on, I turned back to reality and flipped the watch dogs on (YES THEY WERE OFF). I'll investigate the connections between the plant and control system some more in the morning (i.e. later today) (this is also probably what is causing the "lost connections" in c1sup/sus we can see in the machine status screen).

 Problem with ITMX solved! The ITMX block in c1sup hadn't been tagged as "top_names". I rebuilt and installed the model, and there are no longer lost connections, :D

  7225   Sat Aug 18 17:09:01 2012 SashaUpdateSimulationsC1LSP MEDM Screens Added

C1LSP has been added to the site map. I'll work on filling in the structure some more today and tomorrow (as well as putting up PDH and REFL/AS MEDM screens).

NOTE: Does anyone know how to access channels (or if they're even there) for straight Simulink inputs and outputs (i.e. I have some sort of input, do something to it in the simulink model, then get some output)? I've been trying to add ADC MEDM screens to c1lsp, but channels along the lines of C1LSP-ADC0_0_Analog_Input or C1LSP-ADC0_A0 don't seem to exist.

  7227   Sat Aug 18 19:40:47 2012 SashaUpdateSimulationsC1LSP MEDM Screens Added

Quote:

C1LSP has been added to the site map. I'll work on filling in the structure some more today and tomorrow (as well as putting up PDH and REFL/AS MEDM screens).

NOTE: Does anyone know how to access channels (or if they're even there) for straight Simulink inputs and outputs (i.e. I have some sort of input, do something to it in the simulink model, then get some output)? I've been trying to add ADC MEDM screens to c1lsp, but channels along the lines of C1LSP-ADC0_0_Analog_Input or C1LSP-ADC0_A0 don't seem to exist.

 NVM. Figured out that I can just look in dataviewer for the channels. It looks like there aren't any channels for ADC0...I'll try reinstalling the model and restarting the framebuilder.

  8101   Mon Feb 18 23:41:15 2013 SendhilUpdateAlignmentAligned IPPOS, IPANG and OPLEVS

[Yuta, Sendhil]

We aligned IPPOS, IPANG and all OPLEVs (except for ETMX and SRM).

 

1. First aligned the IPPOS by tweeking the steering mirrors inside the BS chamber.

2. Aligned the IPANG by tweeking the steering mirrors inside the BS chamber and ETMY chamber.

3. Aligned the OPLEVS for the BS and PRM was done by tweeking the steering mirrors inside the BS chamber and checked that OPLEV beams were not clipped. 

4. Centred the OPLEV beams for the ITMY and ETMY.

5. For the OPLEV of ITMX the alignment was done by tweeking the steering mirrors inside the ITMX chamber.

 

Attachment 1: IPANGIPPOSoplevs.png
IPANGIPPOSoplevs.png
  3145   Wed Jun 30 12:13:39 2010 Sharmila, KatharineUpdateWIKI-40M Updateweekly update

Weekly Project Update:

We are studying Haixing's circuit diagram for the quadrant maglev control circuit.  We have analyzed several of the sub-circuits and plotted transfer functions for these in MatLab.  To check the circuit, we will compare the calculated transfer functions with those obtained from the HP control systems analyzer.

To learn how to use the control systems analyzer, we are reading App Note 243 as well as an online manual (477 pages in the first volume).  We are beginning with a simple test circuit, and are comparing its measured frequencyresponse with calculated transfer functions.  We currently have obtained a response graph beginning at 100 Hz (which we have not yet figured out how to print), and we are planning to investigate behavior at lower frequencies.

We also have been continuing our reading on control systems after a failed attempt at magnetic levitation. 

  3165   Wed Jul 7 11:23:08 2010 Sharmila, KatharineUpdateWIKI-40M Update 

Weekly Update:

Last Weds-Thurs, we wrote and edited our progress reports.

Tuesday (and Weds morning):  Continued circuit analysis of Haixing's circuit and plotting transfer functions (almost have one for entire circuit).  Hooked up OSEM and circuit to power supply, but the LED didn't appear to light up in IR.  Now we are going to hook the OSEM directly to the power supply, sans circuit, to see if the problem is with the circuit or OSEM.