  7747   Mon Nov 26 19:27:59 2012 RijuHowTo Testing AG4395A+GPIBRiju, Jenne
We have checked the transfer function
of a bandpass filter using AG4395A network
 tfmag.jpgtfphase.jpg 
  7756   Tue Nov 27 19:06:16 2012 RijuUpdate Testing AG4395A+GPIB I ve tested another bandpass filter
today with similar set-up. This time I took
the data with corrected reference level.
 tfmag1.jpgtfphase1.jpg 
  7794   Wed Dec 5 17:38:41 2012 RijuHowTo Photodiode transimpedanceI have started making the circuit to measure
the transimpedance for the photodiode PDA10CF
using Jenne's laser. I will continue it tomorrow.
  
  7817   Wed Dec 12 17:26:47 2012 RijuUpdate Testing AG4395A+GPIBI repeated my experiment to get noise level.
To get that I disconnected the bandpass filter
SBP-10.7  from channel A of network
 TFbandpassfilter.pdf 
  7834   Fri Dec 14 14:40:31 2012 RijuUpdate Photodiode transimpedancePhotodiode PDA10CF was under test. The
RF out signal of AG4395A had been divided
by splitter with one output of the splitter
 PDA10CF.pdf 
  7870   Fri Dec 21 19:49:39 2012 RijuUpdate Photodiode transimpedanceI have repeated the transimpedance measurement
of PDA10CF. Also made the dark current noise
measurement by connecting the PDA10CF output
 PDA10CFrepeat.pdfdarknoiseVpda10cf.pdfdarknoiseApda10cf.pdfPDA10CF_z.pdf 
  7874   Thu Jan 3 20:34:43 2013 RijuUpdate Photodiode transimpedanceToday I have measured the transimpedance
and dark-noise of the MC-REFL PD.
For transimpedance measurement I
  
  7880   Tue Jan 8 14:01:21 2013 RijuUpdate Photodiode transimpedance Here I upload the plots corresponding
to my last day's measurements.
 
 TFreflpd.pdfREFL_z.pdfdarknoiseVreflpd.pdfdarknoiseAreflpd.pdf 
  7881   Tue Jan 8 14:07:04 2013 RijuUpdateElectronicsPhotodiode transimpedance

    

       
            
  
  7882   Tue Jan 8 15:28:41 2013 RijuUpdateElectronicsPhotodiode transimpedance

    

       
            
 analyzernoiseV.pdf 
  7887   Wed Jan 9 19:32:24 2013 RijuUpdate Photodiode transimpedanceSummary:
Today I have tested the MC transmission-end
RF photodiode PDA255 for transimpedance and
 PDA255.pdfPDA255_z.pdfdarknoiseVpda255.pdfdarknoiseApda255.pdfdarknoise_comparison.pdf 
  7907   Wed Jan 16 18:58:08 2013 RijuUpdate Photodiode transimpedanceToday I have taken the reading for shot
noise intercept current for the PDA255 -
MC transmission RF PD. To do that I have
  
  7926   Tue Jan 22 17:29:29 2013 RijuUpdate Photodiode transimpedanceRiju
Summary:  I am stuck with the
measurement of shot-noise-intercept-current
 pda255shotnoiseintercept.pdf 
  7929   Wed Jan 23 11:43:19 2013 RijuUpdate Photodiode transimpedance

    

       
            
 pda255shotnoiseintercept1.pdf 
  7933   Wed Jan 23 20:27:05 2013 RijuUpdate Photodiode transimpedanceToday I have repeated the expt for shot
noise intercept current. Koji found that
the Spectrum analyzer is going to saturation,
  
  7946   Mon Jan 28 17:59:02 2013 RijuUpdate Photodiode transimpedanceSummary: Measurement and plot of
shot-noise-intercept-current for PDA255.
 shotnoiseinterceptpda255.pdf 
  7956   Tue Jan 29 18:40:20 2013 RijuUpdate Photodiode transimpedanceToday I have taken data for shot noise
intercept current for PDA10CF. I will process
the data and report.
  
  7972   Thu Jan 31 12:44:42 2013 RijuUpdate Photodiode transimpedanceToday I collected the data for shot noise
intercept current for MC REFL PD. I didn't
get many data points at higher DC voltage
  
  7976   Thu Jan 31 15:34:22 2013 RijuUpdateRF SystemPhotodiode transimpedance

    

       
            
  
  7977   Thu Jan 31 15:56:38 2013 RijuUpdate Photodiode transimpedanceSummary: Measurement  shotnoiseinterceptpda10cf.pdf 
  7984   Fri Feb 1 14:47:17 2013 RijuUpdate Photodiode transimpedance Summary:  shotnoiseinterceptmcreflpd.pdf 
  8027   Thu Feb 7 19:24:57 2013 RijuUpdate Photodiode transimpedance Summary:  reflshotnoise.pdf 
  8186   Wed Feb 27 17:43:54 2013 RijuUpdate Photodiode transimpedanceHere is the transimpedance for the other
PD used for MC REFL
 TFnewreflpd.pdfNewREFL_z.pdf 
  8188   Wed Feb 27 18:17:05 2013 RijuUpdate Photodiode transimpedance

    

       
            
  
  8189   Wed Feb 27 18:38:51 2013 RijuUpdate Photodiode transimpedance

    

       
            
  
  8484   Wed Apr 24 14:24:40 2013 RijuUpdate PD frequency response Here I am attaching the first schematic
diagram of the PD frequency response set-up,
I will keep updating it with relevant informations
 PD_freq_resp.pdf 
  8488   Thu Apr 25 00:59:37 2013 RijuUpdateRF SystemPD frequency response

    

       
            
  
  8492   Thu Apr 25 17:56:28 2013 RijuConfiguration PD frequency response [Eric, Riju]
Today we have routed the fibers from
1x16 fiber splitter to POX table for POX11
 IMG_0495.JPG 
  8497   Fri Apr 26 17:08:42 2013 RijuConfiguration PD frequency response

    

       
            
  
  8506   Mon Apr 29 17:26:22 2013 RijuConfigurationRF SystemPD frequency response Today I have rerouted the fibers
on AP table to remove the fiber rolls out
of the AP table.  I removed the fibers
 7x 
  8512   Tue Apr 30 19:39:14 2013 RijuConfigurationRF SystemPD frequency responseToday I have rerouted the fibers on POX
table. The aim was to lay it overhead through
the plastic pipe. A pipe ~50ft (~15.5m) long
 IMG_0511.JPGIMG_0512.JPGIMG_0513.JPGIMG_0514.JPGIMG_0515.JPG 
  8520   Wed May 1 17:36:26 2013 RijuConfigurationRF SystemPD frequency response Today I routed fiber from 1x16 splitter
to POY table. Manasa helped me doing that.
The fiber(25m) was laid on overhead
 IMG_0517.JPGIMG_0518.JPGIMG_0519.JPG 
  8573   Tue May 14 19:52:58 2013 RijuConfigurationRF SystemPD frequency response [Eric, Riju, Annalisa]
Today we have cleared up the fiber
spool near AP table. We have put the 1x16
 IMG_0520.JPGIMG_0521.JPG 
  7486   Thu Oct 4 23:01:49 2012 RijuparnaConfiguration cavitymode scan Here I am attaching the schematic
diagram of the experimental set-up for IMC
cavitymode scanning. A 30- 45MHz scanning
 diagram1.pdf 
  7519   Wed Oct 10 15:31:59 2012 RijuparnaUpdate cavitymode scan Rijuparna, Jenne
Today I checked the optical lay-out
in MC REFL board of the
  
  7537   Fri Oct 12 15:31:03 2012 RijuparnaConfiguration cavitymode scan Rijuparna, Manasa
Today I have checked the optical
layout of the MC transmission RFPD table
  
  7351   Thu Sep 6 17:06:25 2012 Rijuparna ChakrabortyConfigurationelogCavitymode scan Aim: to scan the cavitymodes of IMC
The circuit used: 
 Attachment4
 3.pdf2.pdf1.pdfcavityscanconnections.pdf 
  7363   Fri Sep 7 15:58:29 2012 Rijuparna ChakrabortyUpdate cavitymode scan IMC transmission photodiode has been
aligned.
  
  7368   Sat Sep 8 00:15:57 2012 Rijuparna ChakrabortyUpdate cavitymode scan

    

       
            
  
  7376   Wed Sep 12 19:26:08 2012 Rijuparna ChakrabortyUpdate cavitymode scan Summary: Recorded the presence of
higher order modes in IMC
What I did: Misaligned the flat mirror
 7x 
  603   Mon Jun 30 14:07:26 2008 RobConfigurationPSLDon't put the bin in front of the air conditioning unit[quote]We spotted that the laser power was
dropping.
[/quote]
 DSC_0140.png 
  1306   Sun Feb 15 15:53:21 2009 RobUpdateLSCLocking status[quote]
  I didn't get a chance to do much testing
since the sus controller (susvme1) went nuts.
  
  623   Wed Jul 2 13:56:10 2008 Rob, Yoichi, JohnUpdateLocking24.5 Hz resonanceWork continues on trying to reduce the CARM
offset using dc signals from PO_DC. Got up
to arm powers of
 locking080702.png 
  630   Thu Jul 3 13:12:32 2008 Rob, Yoichi, JohnUpdateLockingMore oscillationsBounce/ roll filters were added to the short
degrees of freedom to reduce the effect of
the 24Hz line seen on Tuesday night.
 LOL.pngNoisyX080702.pngPOXforCARM080702.png 
  13823   Mon May 7 20:01:14 2018 RorpheusUpdateGeneralUse anti-dewhitening + show CARMA/DARMA    
  6422   Thu Mar 15 08:48:40 2012 RyanSummaryCDSSummary of Syracuse Visit to 40m Mar 5-9 2012JIMS Channels in PEM Model
The
PEM model has been modified now to include
the JIMS(Joint Information Management System)
  
  6518   Wed Apr 11 12:25:11 2012 RyanUpdateComputersUpdating aLIGO ConlogOver the next few days, I will be working
on upgrading the aLIGO Conlog install to
include new bugfixes distributed by Patrick
  
  6539   Tue Apr 17 10:55:50 2012 RyanUpdateComputersUpdating aLIGO Conlog

    

       
            
  
  6373   Wed Mar 7 13:59:07 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:In order to install the necessary extensions
to epics to make the aLIGO conlog work, I
have edited one file in the base epics install
  
  6377   Wed Mar 7 18:00:39 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:


   
        
            
  
ELOG V3.1.3-