  618   Tue Jul 1 21:45:48 2008 JohnUpdatePSLMach Zehnder script and screenI've edited C1: PSL_MACH_ZEHNDER.adl and /cvs/cds/caltech/scripts/PSL/MZ/lockMZ
to reflect the changes described in entry
#616.
  
  2406   Sun Dec 13 20:50:45 2009 ranaSummaryIOOMach Zender CalibrationI ramped the MZ PZT (with the loop disabled
on the input switch) to calibrate it. Since
the transmission has been blocked, I used
 Untitled.png 
  1151   Fri Nov 21 16:11:26 2008 rana, alberto, robUpdatePSLMach Zender alignmentThe Mach Zender's dark port DC voltage had
gone up too high (~0.5 V)and was turning
yellow
 PB210051-1.JPG 
  1155   Fri Nov 21 20:29:43 2008 rana, alberto, robUpdatePSLMach Zender alignment[quote] So now the MZ alignment seems good;
Alberto is on the MC periscope alignment
like a cheap suit.[/quote]
  
  1160   Mon Nov 24 17:14:44 2008 ranaUpdatePSLMach Zender trendsIt looks like the MZ has gotten less drifty
after the alignment on Friday.
 Untitled.png 
  293   Fri Feb 1 17:17:05 2008 JohnSummaryPSLMach-Zender tweakingI helped Rob adjust the alignment of the Mach-Zender
to try and reduce any AM on the laser light.
Our goal was to reduce the large offsets
  
  7418   Thu Sep 20 08:50:14 2012 MashaUpdateMachineLearningMachine Learning Update Hi everyone,
I've been working a bit on neural
network code for a controller, and thus far
  
  14164   Wed Aug 15 12:15:24 2018 gautamUpdateCOCMacroscopic SRC length for SR tuningSummary:

It
 SRC_MCMC_shortTerm.pdfSRC_dists_shortTerm.pdf 
  6991   Thu Jul 19 02:14:37 2012 JenneUpdateVIDEOMade a video guiI learned a little bit of python scripting
while looking at the videoswitch script,
and I made a video medm screen. 
  
  1497   Sun Apr 19 11:51:05 2009 josephbUpdateCamerasMafalda may need an updateI tried installing libusb-dev on mafalda
in order to try getting the usb frame grabber
to work on it, but could not as it could
  
  1499   Mon Apr 20 11:57:27 2009 robUpdateCamerasMafalda may need an update


   
        
            
  
  1501   Mon Apr 20 18:36:37 2009 ranaUpdateCamerasMafalda may need an updateSadly, the sensoray crap doesn't seem to build
on CentOS. I too would prefer a homogenous
solution, 
  
  3714   Thu Oct 14 10:29:33 2010 josephbUpdateComputersMafalda ready for NDS2, updated Rosalba, Rossa reposAt John Zweizig's request, I installed
a couple of packages from the lscsoft repository,
along with libtools, automake, autoconf,
  
  345   Thu Feb 28 16:19:37 2008 josephbConfigurationComputersMafalda rewired and multiple cameras running1) Mafalda is now connected via an orange
Cat5E ethernet cord to the gigabit ethernet
switch in rack in the office space.    It
  
  1183   Sun Dec 7 16:02:46 2008 ranaUpdateGeneralMag 5.1 EQ halfway to VegasThere was a [URL=http://earthquake.usgs.gov/eqcenter/recenteqsww/Quakes/ci14408052.php#details]Mag
5.1 EQ[/URL] Friday night at 8:18 PM.
 g.pngUntitled.png 
  1513   Thu Apr 23 21:13:37 2009 YoichiSummaryEnvironmentMag. 4 earthquake in LA tripped the watchdogs of the most optics So far, no damage is noticeable.
restoreWatchdog script was useful :-)
  
  4120   Thu Jan 6 00:06:01 2011 JenneUpdateIOOMagical absorbing PZT mirror[Kiwamu, Jenne]
We have a measely 465mW going into
  
  3100   Wed Jun 23 11:25:14 2010 Katharine and SharmilaUpdateWIKI-40M UpdateMaglevWeekly update

Lab work
  
  3212   Wed Jul 14 01:05:27 2010 Sharmila,KatharineSummaryelogMaglevYesterday we hooked up the Quadrant Maglev
control to the power supply to test the components
in the Input/Output part of the circuit.
 P7120284.JPGP7120278.JPGP7120281.JPGP7140292.JPG 
  3250   Tue Jul 20 11:55:15 2010 Sharmila,KatharineUpdateelogMaglevWe plotted the transfer functions for the
maglev control circuit and compared them
with the plots from the spectrum 
 tf.pngP7140292.JPG 
  3305   Wed Jul 28 12:09:06 2010 Sharmila,KatharineUpdateWIKI-40M UpdateMaglevWe have modeled our maglev setup in simulink
but we have a few corrections to make since
the system goes into undamped oscillations
 Picture_1.png 
  14262   Mon Oct 22 15:19:05 2018 SteveUpdateVACMaglev controller servicedGautam & Steve,

Our controller is back with Osaka
maintenace completed. We swapped it in this
 our_controller_is_back.png 
  9550   Mon Jan 13 16:50:55 2014 SteveUpdateVACMaglev controller needs service

    

       
            
  
  9776   Wed Apr 2 16:34:15 2014 SteveUpdateVACMaglev controller needs service

    

       
            
  
  14189   Wed Aug 29 09:56:00 2018 SteveUpdateVACMaglev controller needs serviceTP-1 Osaka maglev controller  [ 
model TCO10M,  ser V3F04J07 ] 
needs maintenance. Alarm led  on indicating 
  
  9834   Mon Apr 21 10:14:00 2014 SteveUpdateVACMaglev controller serviced

    

       
            
 ourControllerBack560Hz.png 
  9782   Thu Apr 3 17:05:52 2014 SteveUpdateVACMaglev controller swapped

    

       
            
 loanerControllerIn.png 
  3431   Tue Aug 17 23:59:46 2010 KatharineUpdateelogMaglev updateKatharine, Sharmila

Update:  
 repulsiveforce.pngOSEMcalibration.pngOSEMslopes.png 
  2193   Fri Nov 6 12:56:30 2009 HaixingUpdateSUSMagnet has been levitated  

 DSC_0964.JPGblock_diagram.PNG 
  12328   Sun Jul 24 03:43:56 2016 ericqUpdateGeneralMagnet positioningWhen Koji and I were gluing magnets to
ETMY, we decided to position the side magnet
based on the empirically observed offsets
  
  1933   Fri Aug 21 17:28:50 2009 Kevin, ranaSummaryPEMMagnetic Field Measurements Around the Lab


 AC-field.pngDC-field.png 
  2307   Fri Nov 20 11:32:48 2009 HaixingUpdateSUSMagnetic levitationI added an integrator to increase
the gain at low frequencies (below 5 Hz).
In addition, I increased
 IntDiff.PNGS8007340.jpgS8007333.jpg 
  691   Thu Jul 17 16:39:58 2008 Max JonesUpdateDAQMagnetometer InstalledToday I installed the magnetometer near the
beam splitter chamber. It is located on the
BSC chamber at head height on the inner part
  
  2629   Mon Feb 22 21:07:26 2010 JenneUpdateCOCMagnets glued to ITMX[Kiwamu, Jenne]
The magnets + dumbbell standoffs
have been glued to ITMX.  We're waiting
  
  3777   Mon Oct 25 11:39:06 2010 JenneUpdateSUSMagnets glued to PRMThis morning I glued the magnets to the PRM.
 Now we wait, and tomorrow afternoon (at
the earliest), Suresh and I can balance the
 StatusTable.png 
  14628   Tue May 21 00:15:21 2019 gautamUpdateSUSMain objectives of vent achieved (?)Summary:


ETMY now shows four suspension
eigenmodes, with sensible phasing between
 etmy_oplevs_20190520.pdfETMY_cplxTF.pdfETMY_diagComp.pdfScreen_Shot_2019-05-21_at_12.37.08_AM.png 
  15279   Wed Mar 18 21:43:26 2020 gautamUpdateVACMain vol pressure jumpThere was a jump in the main volume pressure
at ~6pm PDT yesterday. The cause is unknown,
but the pressure doesn't seem to be coming
 VacPresJump.png 
  15280   Wed Mar 18 22:10:41 2020 KojiUpdateVACMain vol pressure jumpI was in the lab at the time. But did not
notice anything (like turbo sound etc). I
was around ETMX/Y (1X9, 1Y4) rack and SUS
  
  14436   Tue Feb 5 19:30:14 2019 gautamUpdateVACMain volume at 20 uTorrPumpdown looks healthy, so I'm leaving
the TPs on overnight. At some point, we should
probably get the RGA going again. I don't
 PD83.png 
  11346   Fri Jun 5 11:59:59 2015 ericqBureaucracyGeneralMaintenance Tasks, IFO upgradesAt wednesday's
meeting, Rana, Koji, Steve, and I started
making a list of maintenence tasks that should
  
  7075   Thu Aug 2 00:43:55 2012 JenneUpdateASSMajor cleanup of the ASS model[Jamie, Jenne]
We are trying to figure out what
the story is with the ASS, and in order to
  
  7081   Thu Aug 2 23:31:04 2012 JenneUpdateASSMajor cleanup of the ASS modelJamie re-redid the ASS model a few hours
ago.
I have just compiled it, and restarted
  
  4993   Tue Jul 19 23:39:11 2011 Jamie, JenneUpdateLSCMajor overhaul of LSC rack; binary switching of whitening filters now workingYesterday we started going through the
LSC binary whitening switching to make sure
the new switching control in the LSC model
  
  14930   Thu Oct 3 12:08:47 2019 gautamUpdateGeneralMake the Jenne-laser setup fiber-coupledI propose the following re-organization
of the PDFR measurement breadboard. We have
all the parts on hand, just needs ~30mins
 PDFR_tabletop.pdfIMG_8014.JPG 
  14931   Thu Oct 3 14:32:37 2019 ranaUpdateGeneralMake the Jenne-laser setup fiber-coupledI'm
curious to see if we really need the 1611,
or if we can calibrate the diode laser vs.
  
  14932   Thu Oct 3 14:54:33 2019 KojiUpdateGeneralMake the Jenne-laser setup fiber-coupledI'm afraid that the RF modualtion of
the laser is nonlinear and the electrical
and optical resoponse is dependent on the
  
  14934   Thu Oct 3 21:05:04 2019 aaronUpdateGeneralMake the Jenne-laser setup fiber-coupledI measured the RF response of the fiber-coupled
NewFocus 1611, calibrating out the cable
delay. The laser current was set to 20.0
 PD_response.pdf 
  14936   Thu Oct 3 23:15:39 2019 KojiUpdateGeneralMake the Jenne-laser setup fiber-coupledThe 1GHz PD has a bit more flat response,
but the laser and the driving network have
more frequency dependence as you saw.
  
  14937   Fri Oct 4 00:30:31 2019 gautamUpdateGeneralMake the Jenne-laser setup fiber-coupledI think the metric of interest here is
the consistency of the AC transimpedance
of the proposed new "Reference PD"
  
  14940   Fri Oct 4 14:25:59 2019 aaronUpdateGeneralMake the Jenne-laser setup fiber-coupledSummary:

The fiber-coupled
PD seems to have a factor of ~1.5 difference
in responsivity compared to the free-space
 PD_norm.pdfPD_AB.pdfJenneAM_fiberPD_cals.pdf 
ELOG V3.1.3-