40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 140 of 344  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  6998   Sat Jul 21 14:05:21 2012 DenUpdatePSLPMC problems examined

    

       
            
 fss_slowm.png 
  6999   Sat Jul 21 14:48:33 2012 DenUpdateCDSRCGAs I've spent many hours trying to determine
the error in my C code for online filter
I decided to write about it to prevent people
  
  7000   Sat Jul 21 18:04:02 2012 DenUpdateAdaptive Filteringfrequency domain filterI've implemented online frequency domain
filter and applied it to MC_F.
 freq_af.png 
  7001   Mon Jul 23 07:39:55 2012 Ryan FisherSummaryComputer Scripts / ProgramsAlterations to base epics install for installing aLIGO conlog:Note:  The Conlog install instructions that
I started from were located here:
https://awiki.ligo-wa.caltech.edu/aLIGO/Conlog
  
  7002   Mon Jul 23 13:30:06 2012 JenneUpdateGreen LockingYarm ALS laser is funny / dyingJamie and I were doing some locking, and
we found that the Yarm green wasn't locking. 
It would flash, but not really stay locked
  
  7003   Mon Jul 23 17:39:34 2012 JenneUpdateIOOMC_F vs. MC_L[Rana, Jenne]
We looked at the different outputs
of the MC servo board to make sure they make
 MCF_vs_MCL_23July2012.pdf 
  7004   Mon Jul 23 18:01:30 2012 JenneUpdateGreen LockingYarm ALS laser is funny / dying I turned the Yend laser back on....it
hasn't turned itself off yet, but I'm watching
it.  As long as we leave the shutter
  
  7005   Mon Jul 23 18:16:13 2012 JamieUpdateSUSDQ block added to sus_single_control library partsI have added a DQ block to the sus_single_control
library part.  This means that all sus
models will automatically generate DQ channels
  
  7006   Mon Jul 23 18:38:58 2012 JenneUpdatePSLPSL channels added to IOO modelI added a subblock to the IOO model, and
gave it a top_names of PSL, so the channels
show up as C1:PSL-......
  
  7007   Mon Jul 23 18:41:15 2012 JamieUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThe end sus models (c1scx and c1scy) both
contain some ALS stuff.  This stuff
could maybe be moved to their own models,
 alsend.png 
  7008   Mon Jul 23 18:57:52 2012 JamieUpdateCDSc1scx and c1scy models recompiled and restartedAfter the changes listed in 7005
and 7007,
I have rebuilt, installed, and restarted
  
  7009   Mon Jul 23 19:00:26 2012 KojiUpdateGreen LockingALS_END.mdl model added for end station green ALS channelsThis is a good modification. We just need
to check how the ALS scripts are affected.

  
  7010   Mon Jul 23 19:13:12 2012 JenneUpdatePSLPSL channels added to IOO model

    

       
            
  
  7011   Mon Jul 23 19:50:43 2012 JamieUpdateCDSc1gcv model renamed to c1alsI decided to rename the c1gcv model to
be c1als.  This is in an ongoing effort
to rename all the ALS stuff as ALS, and get
  
  7012   Mon Jul 23 20:19:01 2012 LizUpdateComputer Scripts / ProgramsInput Needed (From everyone!)The summary pages
are now online
  
  7013   Mon Jul 23 20:34:38 2012 JamieOmnistructureComputersCHECK IN YOUR CHANGES TO THE SVNI'm seeing LOTS OF STUFF NOT CHECKED INTO
THE SVN!!!  both modified
  
  7014   Mon Jul 23 21:17:58 2012 LizUpdatePEMWeather Station Works!Rana and I traced the cables that ran from
c1pem1 to the
  
  7015   Mon Jul 23 21:54:48 2012 ranaUpdatePEMWeather Station Works!To get the code to run on c1pem1, we had
to move the old target back into the /cvs/cds/caltech/target/
directory.  It is in /cvs/cds/caltech/target/c1pem1/.
 Untitled.png 
  7016   Tue Jul 24 02:12:14 2012 MashaUpdatePEMBLRMS, MEDM, TriangulationToday I worked with the BLRMS channels,
re-triangulated the seismometers (the STS
is now on the very end of the Y-arm, while
  
  7017   Tue Jul 24 03:14:13 2012 JenneUpdateASSCalibration of MC ASS lockinsI wanted to check that the calibration
of the MC ASS lockins was sensible, before
trusting them forevermore.
  
  7018   Tue Jul 24 12:06:41 2012 MashaUpdatePEMNew RMS channels, New C1PEM OverviewAs Jenne suggested last night, I changed
the C1PEM overview in Epics. Previously,
the C1PEM_OVERVIEW.adl screen had two separate
 NewRMSFrames.png 
  7019   Tue Jul 24 15:17:10 2012 MashaUpdatePEMRMS Filters, PEM SitemapRMS Filters
How Den, Rana, and I chose RMS filters:
 GUR1Z0p3to1FilterCoherence.pngGUR1Z3to10FilterCoherence.pngGUR1Z3to10FilterSignal.png 
  7020   Tue Jul 24 18:33:12 2012 YaakovUpdateVIDEOCentering the MCR cameraJenne and I centered the MCR camera   
  7021   Tue Jul 24 21:16:55 2012 DenUpdatedigital noisequantization testI'm trying to get some intuition how digital
noise due to quantization shows up in iir
filters. I decided to do tests in C using
 iir_2.pngiir_8.png 
  7022   Wed Jul 25 10:31:33 2012 SashaSummarySimulationsSURF - Week 5 - SummaryThis week I've been working on refining
my simulation and getting it
 Screen_Shot_2012-07-24_at_10.46.05_AM.pngScreen_Shot_2012-07-24_at_10.45.43_AM.pngScreen_Shot_2012-07-25_at_10.16.58_AM.pngScreen_Shot_2012-07-25_at_10.25.27_AM.png 
  7023   Wed Jul 25 11:22:39 2012 LizUpdateComputer Scripts / ProgramsWeek 6 updateThis week,
I made several modifications to the Summary
 P7230026.JPGP7230031.JPG 
  7024   Wed Jul 25 11:25:27 2012 MashaUpdateGeneralSummaryThis week, I have been mainly working on
my new neural network project, and working
with the BLRMS channels.
  
  7025   Wed Jul 25 11:34:31 2012 EricSummarySimulationsSURF UpdateI am continuing work on simulating the
DARM control loop. There is now a block for the length response
 DARM_control_loop_hendries.PNGOLG_old_hendries2.png 
  7026   Wed Jul 25 11:41:00 2012 YaakovUpdateVIDEOCentering the MCR camera

    

       
            
  
  7027   Wed Jul 25 12:00:21 2012 YaakovUpdateSTACISWeekly updateThe past few days I've been working on
making a noise budget for the
  
  7028   Wed Jul 25 14:35:45 2012 SashaSummarySimulationsSURF - Week 5 - Summary

    

       
            
 Screen_Shot_2012-07-25_at_2.20.01_PM.pngScreen_Shot_2012-07-25_at_2.20.15_PM.pngScreen_Shot_2012-07-25_at_2.20.29_PM.pngScreen_Shot_2012-07-25_at_2.23.05_PM.png 
  7029   Wed Jul 25 15:33:55 2012 janoschUpdateLSCringdown measurementWe did our first ringdown measurement on
the Y arm. First we tried to keep the arm
locked in green during the ringdown, but
 Rindown1.png 
  7030   Wed Jul 25 16:31:01 2012 JenneUpdateLSCYarm green locking to arm - PDH box saturating

    

       
            
  
  7031   Wed Jul 25 16:55:01 2012 DenUpdatedigital noisenotch, lowpass filters Direct Form 2 is noisy in the first
test. This is the one similar to Matt's in
his presentation. Input signal was a sine
 6x 
  7032   Wed Jul 25 17:35:44 2012 LizUpdateComputer Scripts / ProgramsSummary Pages are in the right place!The summary pages can now be accessed from
the "Daily Summary" link under
LOGS on the 40 meter Wiki page.
  
  7033   Wed Jul 25 22:16:36 2012 KojiUpdateLSCringdown measurementIs this the step response of the single
pole low pass???
It should have an exponential decay,
  
  7034   Wed Jul 25 23:03:22 2012 ranaUpdatedigital noisenotch, lowpass filtersIf the problem is the precision in DTT,
then why would the noise change when the
corner frequency of the filter is changed?
  
  7035   Thu Jul 26 02:44:17 2012 JenneUpdateIOOCentering the MCR camera[Yaakov, Jenne]
The
short version:
  
  7036   Thu Jul 26 10:22:03 2012 DenUpdatedigital noisenotch, lowpass filters

    

       
            
 same_bw.png16384_bw0p8.pngcorners_bw0p1.pngcorners_bw0p01.png 
  7037   Thu Jul 26 12:10:28 2012 DenUpdateCDSnew c1tst model for testing RCG code

    

       
            
  
  7038   Thu Jul 26 13:10:51 2012 janoschUpdateLSCmodelled ringdownWe fitted shutter and ringdown functions
to the ringdown data. It is not perfectly
clear how the power change due to the shutter
 Ringdown.png 
  7039   Thu Jul 26 15:43:03 2012 ranaUpdateLSCmodelled ringdownYou cannot use the digital system for this.
You hook up a scope to the transmitted light
as well as the incoming light (after the
  
  7040   Thu Jul 26 16:08:59 2012 YaakovUpdateSTACISNoise plot updateI have a tentative noise plot for the STACIS
that includes accelerometer noise, geophone
noise, and platform motion with the STACIS
 stacy_noise.bmpstacy_noise.figfeedbacks.bmpfeedbacks.fig 
  7041   Thu Jul 26 17:39:49 2012 DenUpdatedigital noisebiquad key is working I've filtered a 1 Hz sin wave excitation
with a notch filter inside c1sus and c1rfm
models. The biquad key is switched on in
 df2_bqf.pngdf2_bqf_spec.pngiir_psd_notch.pngiir_time_notch.png 
  7042   Thu Jul 26 21:31:44 2012 DenUpdatedigital noiseonline biquad works

    

       
            
 df2_bqf_lp.pngdf2_bqf_lp_spec.png 
  7043   Fri Jul 27 14:27:14 2012 JamieUpdateCDSnew c1tst model for testing RCG code

    

       
            
  
  7044   Fri Jul 27 14:28:36 2012 steveUpdateVACcold cathode gaugesOur cold
cathode 423 gauges are 10 years old.
They get insulated by age and show no ionization
 cc_gauges.png 
  7045   Fri Jul 27 14:30:49 2012 JamieUpdatedigital noisebiquad key is workingWhat is "DQF"?  Is that
the biquad?  And what is the difference
between DF1 and DF2?  Why don't you
  
  7046   Fri Jul 27 16:32:17 2012 JamieUpdateCDSRCG bug exposed by simple c1tst modelAs Den mentioned in 7043,
attempting to run the c1tst model was causing
the entire c1iscey machine to crash. 
  
  7047   Mon Jul 30 09:00:18 2012 steveUpdatePSLPMC is still not fixedThe PMC was locking right the way, but
it's transmission would not go up. 
Finally I get it back up by moving the "sticky"
 pmcA.pngpmcB.png 
ELOG V3.1.3-