40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 13 of 170  Not logged in ELOG logo
Entry  Mon Jul 21 09:52:05 2008, Sharon, Update, , Adaptive code changes 
Entry  Mon Jul 21 10:00:42 2008, steve, Update, PEM, ifo room temp temp5y.jpg
Entry  Mon Jul 21 11:54:00 2008, Jenne, Update, General, MC Servo Board 
Entry  Mon Jul 21 14:26:11 2008, Max, Summary, PEM, Added Channels 
Entry  Mon Jul 21 15:52:22 2008, steve, Bureaucracy, SAFETY, fire alarms test 
Entry  Mon Jul 21 19:48:57 2008, Sharon, Update, , how tp restart C1ASS 
Entry  Mon Jul 21 19:55:16 2008, rana,jenne, Configuration, IOO, Noise in MC_F SCRN0024.GIF
Entry  Tue Jul 22 09:24:17 2008, steve, Update, PSL, laser power power120d.jpg
Entry  Tue Jul 22 11:55:22 2008, rana, Update, PSL, Note from R. Abbott re: the PMC 
    Reply  Tue Jul 22 13:15:14 2008, rob, Update, PSL, Note from R. Abbott re: the PMC 
Entry  Tue Jul 22 03:03:22 2008, John, Rob, Update, PSL, FSS open loop transfer function 
    Reply  Tue Jul 22 13:16:09 2008, John, Rob, Update, PSL, FSS open loop transfer function 
Entry  Tue Jul 22 16:50:09 2008, steve, Metaphysics, Environment, professorial clean up of work bench ranaclup.pngcleanup2.png
Entry  Tue Jul 22 22:11:58 2008, Yoichi, Update, LSC, X-arm g factor measurement 
Entry  Tue Jul 22 22:25:31 2008, rana, Update, LSC, Looptickle for existing 40m nb.png
Entry  Wed Jul 23 01:42:26 2008, rana, Configuration, PSL, FSS RFPD: Examined, "repaired", and re-installed Untitled.pdf
Entry  Wed Jul 23 10:47:05 2008, Sharon, Update, , Weekly update 
Entry  Wed Jul 23 10:49:37 2008, Max, Update, Computer Scripts / Programs, Weekly Progress Report 
Entry  Wed Jul 23 12:42:23 2008, Eric, Summary, Cameras, Weekly Summary PMCScanSinglePeak.tifPMCScanWide.tifPMCSlowSinglePeak.tif
Entry  Wed Jul 23 13:52:26 2008, Sharon, Update, , MEDM changes matrix
Entry  Wed Jul 23 16:31:02 2008, Alberto, Configuration, Computers, Megatron connected 
    Reply  Wed Jul 23 17:19:48 2008, Alberto, Configuration, Computers, Megatron connected 
Entry  Wed Jul 23 18:42:18 2008, Jenne, Update, PSL, Alignment of AOM 
Entry  Wed Jul 23 21:48:30 2008, rob, Configuration, General, restore IFO when you're done with it 
Entry  Thu Mar 13 02:52:06 2008, Lisa, Configuration, LSC, Locking with 3f 
    Reply  Thu Jul 24 01:04:01 2008, rob, Configuration, LSC, IFR2023A (aka MARCONI) settings 
Entry  Thu Jul 24 03:08:20 2008, rob, Update, Locking, +f2 DRMI+2ARMS 
Entry  Wed Jul 23 22:34:07 2008, Yoichi, Update, LSC, Arm cavity g-factor measurement 
    Reply  Thu Jul 24 01:27:00 2008, Koji, Update, LSC, Arm cavity g-factor measurement 
       Reply  Thu Jul 24 02:57:26 2008, rob, Update, LSC, Arm cavity g-factor measurement 
          Reply  Thu Jul 24 08:09:26 2008, Yoichi, Update, LSC, Arm cavity g-factor measurement 
Entry  Thu Jul 24 11:49:07 2008, Masha, Summary, Auxiliary locking, belated weekly summary filter_tr_function.pdffiltered_spectr0724.pdf
Entry  Thu Jul 24 19:29:26 2008, Yoichi, Configuration, PSL, C1:PSL-STAT_FSS_NOM_C_GAIN is changed from 30 to -0.7 
Entry  Thu Jul 24 21:04:58 2008, rana, Update, PSL, FSS 
Entry  Thu Jul 24 21:53:00 2008, rana, Summary, Treasure, High School Tour group and the PMC 
Entry  Fri Jul 25 13:30:53 2008, Sharon, Update, , Changes in ASS computer 
Entry  Fri Jul 25 17:32:46 2008, Sharon, Update, , ASS computer 
Entry  Fri Jul 25 19:57:18 2008, Jenne, Update, PSL, Ref Cav & PMC 
Entry  Sat Jul 26 15:09:57 2008, Aidan, Update, Computers, Reboot of op440m 
Entry  Sun Jul 27 20:25:49 2008, rana, Configuration, Environment, Office Temperature increased to 75 F 
Entry  Sun Jul 27 23:06:17 2008, rana, Update, PSL, PMC, MZ, MC-MMT, etc. 
Entry  Mon Jul 28 11:20:13 2008, Jenne, Update, PSL, Work on the FSS and Reference Cavity 
Entry  Mon Jul 28 12:02:32 2008, Sharon, Update, , accelerometers settings 
Entry  Mon Jul 28 17:44:07 2008, rana, Update, PSL, PMC PZT v. temperature Untitled.pdf
Entry  Mon Jul 28 17:58:05 2008, Sharon, Update, , TOP screen changes 
Entry  Mon Jul 28 23:41:07 2008, rob, Configuration, PSL, FSS/MC gains twiddled 
Entry  Tue Jul 29 01:03:17 2008, rob, Configuration, IOO, MC length measurement 
    Reply  Tue Jul 29 09:12:43 2008, Koji, Configuration, IOO, MC length measurement 
Entry  Tue Jul 29 11:50:01 2008, Jenne, Update, Environment, 5.6 Earthquake  
Entry  Tue Jul 29 18:15:36 2008, rob, Update, IOO, MC locked 
Entry  Tue Jul 29 13:54:08 2008, rana, Update, SUS, ETMY and PRM have EQ related problems Untitled.png
    Reply  Tue Jul 29 14:38:02 2008, rob, Update, SUS, ETMY and PRM have EQ related problems 
       Reply  Tue Jul 29 19:53:19 2008, Koji, Update, SUS, PRM photos from the south window PRM_from_South_Window1.jpgPRM_from_South_Window2.jpg
Entry  Tue Jul 29 21:04:55 2008, Sharon, Update, , OSEM's Power Spectrum 8x
Entry  Tue Jul 29 19:41:38 2008, Yoichi, Update, PSL, FSS loop transfer functions 7x
    Reply  Tue Jul 29 23:04:34 2008, Yoichi, Update, PSL, FSS loop transfer functions OpltfPZTOnlyRaw.epsOpltfPZTOnly.eps
Entry  Wed Jul 30 00:42:04 2008, rana, Update, SUS, Trends and file formats Untitled.png
Entry  Wed Jul 30 01:08:50 2008, rana, Summary, SUS, SUS Drift Screen infection-2.png
Entry  Wed Jul 30 12:03:44 2008, Masha, Summary, Auxiliary locking, weekly summary mz_fiber_noise0730.pngsetup0730.JPGMZnoise_sources0727.png
Entry  Wed Jul 30 12:36:19 2008, Sharon, Update, , Weekly update 
Entry  Wed Jul 30 13:08:44 2008, Max Jones, Update, Computer Scripts / Programs, Weekly Summary C1_NoiseBudgetPlot.pdf
ELOG V3.1.3-