40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 138 of 344  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  10384   Thu Aug 14 15:10:47 2014 AndresUpdateIMCCalculation for the input mode cleaner

    

       
            
 SolutionForTheModeCleanerSetup00.pngSolutionForTheModeCleanerSetup11.pngPossibleSetupForModeCleaner.PNGalaModeSolution.zip 
  10383   Thu Aug 14 14:58:03 2014 JenneUpdateGeneralUpdated game plan   2014_Aug_14.pdf 
  10382   Thu Aug 14 02:51:46 2014 JenneUpdateGeneralGame plan[Jenne, Rana]
* Decided that earlier mode hop scan
won't give us the information that we were
 Y_ALS_FINE_PHASE_OUT_noisy_13Aug2014.pdf 
  10381   Wed Aug 13 23:58:49 2014 ranaHowToComputer Scripts / ProgramsHP8591E spectrum analyzer remote scan

    

       
            
 HP8591E_View.pdf 
  10380   Wed Aug 13 23:08:17 2014 ranaUpdateIOOFSS box TFsAs EQ pointed out recently, we're injecting
into the FSS error point just after an RF
pi filter, but before the VGA. We wondered
 FSScomm.pdf 
  10379   Wed Aug 13 22:01:57 2014 ranaUpdateIMCCalculation for the input mode cleanerNic,
Andres, and I discussed some more about the
MC WFS project today. We want
  
  10378   Wed Aug 13 19:23:09 2014 JenneUpdateLSCPSL, Aux laser mode hop checkThis afternoon Q helped me put in some
temporary PDs for checking for any mode hopping
behavior in our 3 main lasers. 
 ModeHopCheck_PSL_13Aug2014.pdfModeHopCheck_Xend_13Aug2014.pdfModeHopCheck_Yend_13Aug2014.pdf 
  10377   Wed Aug 13 17:37:43 2014 JenneUpdateGeneralGame plan   2014_Aug_13.pdf 
  10376   Wed Aug 13 16:12:55 2014 HarryUpdateGeneralFOL Layout DiagramPer Q's request, I've made up a diagram
of the complete FOL layout for general reference.
 FOLLayout2.png 
  10375   Wed Aug 13 13:08:24 2014 ranaUpdateIMCCalculation for the input mode cleanerCan you please give us some more details
on how this design was decided upon? What
were the design considerations?
  
  10374   Wed Aug 13 10:50:04 2014 AndresUpdateIMCCalculation for the input mode cleaner  Calculation for the input mode
cleaner
I have been working on the
calculation for the input mode cleaner. I
 ModeCleanerSetup0.PNGalaModeModeCleanersolution.png 
  10373   Wed Aug 13 10:49:39 2014 HarryUpdateGeneralWeekly Update In the past week, I designed and
assembled coupling telescopes for the PSL
and Y Arm Lasers
  
  10372   Wed Aug 13 03:03:37 2014 ericqUpdateGeneralGreen beatnote troubles[Jenne, Rana, ericq]
No luck locking tonight, as spent
a while trying to figure out the complete
  
  10371   Tue Aug 12 23:07:24 2014 HarryUpdateGeneralPSL TelescopeI put the PSL telescope in place, and started
coupling to it.
Unfortunately, I was only able to
 PSLTelescopePic.png 
  10370   Tue Aug 12 18:20:13 2014 ericqUpdateIOOFSS box TFsI made some measurements of the FSS box
today, to have TFs for a loop model, but
also to see what the difference between the
 FSSbox.pdfFSSfilt.pdfFSSdata.zip 
  10369   Tue Aug 12 14:29:01 2014 ericqUpdateGeneralReasonable alignment restored

    

       
            
 OLtrend.png 
  10368   Tue Aug 12 13:31:58 2014 JenneUpdatePEMSeismometer cables in place, ready for sensors[TaraV, Jenne]
The short cable from the slab to
the sensor has been assembled and installed
  
  10367   Tue Aug 12 02:09:39 2014 ericqUpdateGeneralReasonable alignment restoredI took over the IFO, after Jenne's locking
efforts, which included manual alignment,
since the ASS was doing bad things. 
  
  10366   Mon Aug 11 23:50:38 2014 ranaConfigurationWikiDokuWikis are back up

    

       
            
  
  10365   Mon Aug 11 23:32:54 2014 ericqSummaryIOOMC demod measurementHere's the magnitude plot of the board
TF. As mentioned above, this was done with
Marconi+Scope, so we were not able to get
 MCDemod.pdfdemodLP.txt 
  10364   Mon Aug 11 22:07:31 2014 KojiSummaryIOOMC demod measurementSCLF-5!? It's surprising as the cut off
of the OLTF is just above 1Hz. cf
this entry
  
  10363   Mon Aug 11 21:03:48 2014 ericq, ranaSummaryIOOMC demod measurementWe measured
the TF of the MC Demod board today. 
  
  10362   Mon Aug 11 10:23:39 2014 steveSummarySUSoplev laser summary updated

    

       
            
  
  10361   Mon Aug 11 08:04:01 2014 SteveUpdateSUSETMX damping restored    
  10360   Sun Aug 10 00:54:54 2014 HarryUpdateGeneralAUX CoupingThe Y End laser dumped SHG light has been
coupled into the yellow fiber that terminates
at the PSL table.
  
  10359   Sat Aug 9 14:35:28 2014 KojiSummaryIOOMC servo analysisEric's OLTF turned out consistent with
the AO path TF that has been measured by
me on Jul 31 (entry
 MC_OLTF_Fit.pdfliso.zipMC_CLTF_Fit.pdfMC_CLTF_new.pdfMC_OLTF_new.pdf 
  10358   Fri Aug 8 20:22:12 2014 JenneMetaphysicsGeneralkitchen sink water off

    

       
            
  
  10357   Fri Aug 8 19:42:59 2014 JenneMetaphysicsGeneralkitchen sink flooding When I got back to the lab, there
was enough water that it was seeping under
the wall, and visible outside. Physical plant
  
  10356   Fri Aug 8 18:08:12 2014 KojiSummaryIOOMC servo analysisThe closed gain I meant is the AO path:
Use IN2 to excite the MC loop and measure
IN1 using MON2(?). 
  
  10355   Fri Aug 8 16:45:40 2014 NichinUpdateWikiPDFR wiki updated The PDFR system has been documented
in the 40m wiki and all the relevant information
about making changes and keeping it updated
  
  10354   Fri Aug 8 15:57:29 2014 ericqSummaryIOOMC servo analysis I did some further measurements,
to try and see what corresponds to what.
In the end I performed four measurements:
 OLTFs.pdfCLTFs.pdfmcLoopAug8.zip 
  10353   Fri Aug 8 14:42:41 2014 AkhilUpdateGeneralPID loop Design for beat note stabilization The attached in a zip file are the
Simulink feedback loop models for the FOL
for both X and Y ends. The controller PID
 PID.zip 
  10352   Fri Aug 8 14:27:18 2014 AkhilUpdateComputer Scripts / ProgramsFOL Scripts The scripts written for interfacing
the FC with R Pi, building EPICS database,
piping data into EPICS channels,PID loop
  
  10351   Fri Aug 8 12:39:19 2014 ericqSummaryIOOMC servo analysisI have measured the current boosted MC
CLG below 100kHz with an SR785. Swept sine
only could get me down to 10kHz, but I was
 mcLoopAug8.zipMCloopAug8.pdf 
  10350   Fri Aug 8 11:22:35 2014 steveSummarySUSoplev laser summary 
         
        2005             
  
  10349   Thu Aug 7 17:09:53 2014 HarryUpdateGeneralAUX Coupling In Progress I'm currently in the process of coupling
dumped SHG light from the Y arm end table
into fibers for FOL.
  
  10348   Thu Aug 7 16:47:35 2014 ericqUpdateSUSOplev Checkup I noticed some weird behavior on
the ETMY oplev that led me to check them
all out. 
  
  10347   Thu Aug 7 14:50:43 2014 HarryUpdateGeneralPER Measurement Purpose
I wanted to do a more robust measurement
of PER of PM fibers for FOL, so I thought
 PERFinalSetup.pngPDCalibration.pngPolarization_Intensity_Variation.pngExtrema.pngPEReport.zip 
  10346   Thu Aug 7 13:39:41 2014 NichinUpdateComputer Scripts / ProgramsWrapping up PDFR1)The PDFR scripts have all been migrated
into /scripts/PDFR/
2) The MEDM screen to run PDFR is
  
  10345   Thu Aug 7 12:34:56 2014 JenneUpdateLSCSuspensions not kicking?Yesterday, Q helped me look at the DACs
for some of the suspensions, since Gabriele
pointed out that the DACs may have trouble
  
  10344   Thu Aug 7 12:25:14 2014 JenneUpdateIOOFSS offset changed

    

       
            
  
  10343   Thu Aug 7 11:57:59 2014 KojiSummaryIOOMC servo analysisLISO Fit for the IMC open loop TF. The
data and liso source for the fitting were
attached in the ZIP file.
 MC_OLTF_Fit.pdfIMC_OLTF.zipMC_OLTF_estimated.pdf 
  10341   Wed Aug 6 21:22:09 2014 KojiUpdateIOOFSS offset changedThe fast feedback
should be around zero now!
  
  10340   Wed Aug 6 17:29:36 2014 JenneUpdateIOOFSS offset changedThe MC has been unstable and unhappy for
the last several hours.  When I looked,
I saw that the FSS_FAST monitor has been
  
  10339   Wed Aug 6 13:17:21 2014 ericqOmnistructureCDScdsutils: multifarious upgradesI've checked out cdsutils-274 to /opt/rtcds/cdsutils,
and updated the /ligo/apps/ligoapps-user-env.sh
to have the newer machines use it by default.
  
  10338   Wed Aug 6 12:44:52 2014 KojiUpdateASCPOP QPD signalsThis is nice. Can we test this idea with
POP22 + a razor blade?
Just to take transfer functions in
  
  10337   Wed Aug 6 10:45:56 2014 GabrieleUpdateASCPOP QPD signals In addition to the simulation described
in my
previous elog, I simulated the signal
 pop_qpd_2f.png 
  10336   Wed Aug 6 10:10:45 2014 HarryUpdateGeneralWeekly Plan 8.6.14Last Week
 
Took first round of PER measurements
  
  10335   Wed Aug 6 00:14:10 2014 JenneUpdateLSCALS is iffy tonightThe ALS system is iffy tonight.
After putting the cable back to the
RF spectrum analyzer (it had been taken to
  
  10334   Tue Aug 5 19:20:05 2014 AkhilUpdateGeneralPID loop Design for beat note stabilization Today I and EricQ went inside the
lab and set up the cables running from the
a DAC channel into  PZT input so that
  
ELOG V3.1.3-