Tue Nov 13 11:30:54 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser
|
Tue Nov 13 16:18:51 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : Circularize the 1W NPRO beam profile
|
Tue Nov 13 20:13:07 2012, Koji, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : Circularize the 1W NPRO beam profile
|
Mon Nov 19 20:03:53 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Mon Nov 19 20:17:53 2012, Jenne, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Mon Nov 19 22:42:14 2012, Koji, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Tue Nov 20 11:40:19 2012, rana, Configuration, Green Locking, End table upgrade for auxiliary green laser : ETMX layout on new table
|
Wed Dec 12 11:04:45 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Thu Jan 10 12:41:06 2013, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : wiki page
|
Tue Mar 5 00:24:52 2013, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : customized mount
|
Tue Mar 19 14:21:57 2013, Manasa, Update, 40m Upgrading, Endtable upgrade : INVENTORY
|
Tue Mar 19 19:19:50 2013, Jenne, Update, 40m Upgrading, Endtable upgrade : INVENTORY
|
Wed Mar 20 14:00:21 2013, Steve, Update, 40m Upgrading, Endtable upgrade
|
Wed Mar 20 15:51:54 2013, Manasa, Update, 40m Upgrading, Endtable upgrade
|
Thu Mar 21 08:11:53 2013, Steve, Update, 40m Upgrading, ETMY table swap
|
Thu Mar 21 08:46:46 2013, Manasa, Update, 40m Upgrading, ETMY table swap
|
Thu Mar 21 17:06:34 2013, Steve, Update, 40m Upgrading, ETMY table is out
|
Mon Mar 25 18:07:31 2013, Steve, Update, 40m Upgrading, ETMY table is out
|
Tue Mar 26 16:10:31 2013, Jamie, Update, 40m Upgrading, ETMY table leveling
|
Tue Mar 26 16:36:24 2013, Steve, Update, 40m Upgrading, table leveling mounts go here 
|
Fri Mar 29 16:30:27 2013, Steve, Update, 40m Upgrading, table leveling mounts go here
|
Fri Mar 29 16:35:54 2013, Steve, Update, 40m Upgrading, Endtable upgrade
|
Tue Apr 2 17:23:23 2013, Steve, Update, 40m Upgrading, new ETMY optical table & enclosure in place
|
Thu Apr 4 17:23:05 2013, Steve, Update, 40m Upgrading, ETMY optical table & enclosure is ready for optics
|
Fri Apr 5 01:18:34 2013, Manasa, Update, 40m Upgrading, Not a fan of the new plastic box yet
|
Sat Apr 6 09:21:36 2013, rana, Update, 40m Upgrading, Not a fan of the new plastic box yet
|
Mon Apr 8 16:37:26 2013, Steve, Update, 40m Upgrading, ETMY enclosure wall transmission
|
Mon Apr 22 17:43:09 2013, Steve, Update, 40m Upgrading, ETMY optical table & enclosure is ready for optics
|
Mon Apr 22 19:48:56 2013, Jenne, Update, 40m Upgrading, 4 pins enough?
|
Tue Apr 23 15:00:20 2013, Jenne, Update, 40m Upgrading, 4 pins enough?
|
Mon Mar 25 18:42:38 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : Timeline
|
Fri Mar 29 00:27:06 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : Assembly 
|
Fri Apr 5 01:28:56 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : populating the table
|
Tue Apr 9 00:15:18 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : populating the table
|
Wed Apr 10 14:25:04 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : LWE Alberto laser beam profile 
|
Wed Apr 17 02:20:13 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress 
|
Wed Apr 24 15:27:59 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress: New layout
|
Tue May 7 19:06:45 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Thu May 9 01:36:32 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Thu May 9 22:29:23 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Fri May 10 20:05:21 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Mon May 13 21:35:55 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Tue May 14 14:24:56 2013, Steve, Update, 40m Upgrading, enclosure removal
|
Thu May 16 08:32:05 2013, Steve, Update, 40m upgrading, ETMY op table disabled
|
Fri May 17 00:32:32 2013, Annalisa, Update, 40m upgrading, ETMY - progress
|
Fri May 17 15:38:51 2013, Steve, Update, 40m upgrading, ETMY enclosure is on the way back
|
Fri May 17 16:06:14 2013, rana, Update, 40m upgrading, ETMY op table disabled
|
Fri May 17 18:24:04 2013, Annalisa, Update, 40m upgrading, ETMY - progress
|
Thu May 23 00:16:32 2013, Annalisa, Update, 40m upgrading, ETMY - progress
|
Thu May 23 12:02:48 2013, Steve, Update, endtable upgrade, ETMY - oplev
|
Thu May 30 11:10:00 2013, Steve, Update, endtable upgrade, ETMY - oplev
|
Thu May 30 20:45:53 2013, Annalisa, Update, endtable upgrade, ETMY - oplev
|
Fri May 31 11:15:01 2013, Annalisa, Update, endtable upgrade, ETMY - Mode Matching for green - new calculation
|
Fri Sep 11 10:56:47 2015, Steve, Update, endtable upgrade, ETMY optical table feedthrough
|
Tue Sep 15 16:49:08 2015, Steve, Update, endtable upgrade, ETMY optical table feedthrough
|
Thu Sep 17 02:22:53 2015, Steve, Update, endtable upgrade, ETMY optical table feedthrough
|
Fri May 24 02:12:50 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green  
|
Fri May 24 11:38:00 2013, Koji, Update, 40m upgrading, ETMY - Mode Matching for green
|
Fri May 24 12:50:25 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green
|
Sat May 25 02:03:48 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green - new calculation    
|
Mon May 27 21:38:53 2013, Annalisa, Update, 40m upgrading, ETMY - Beam Dumps
|
Tue May 28 22:11:23 2013, Annalisa, Update, 40m upgrading, ETMY - Yarm shutter cable
|
Tue May 21 17:03:45 2013, Steve, Update, endtable upgrade, enclosure tops are sealed   
|
Thu Jun 6 09:58:13 2013, Steve, Update, endtable upgrade, enclosure to chamber connection 
|
Tue Dec 22 16:39:42 2015, Steve, Update, endtable upgrade, ETMY optical table enclosure  
|
Tue May 14 21:03:15 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Wed May 15 21:27:39 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Thu May 2 01:19:41 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Tue Apr 9 00:32:57 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : TRY temporarily in place
|
Tue Apr 9 08:37:54 2013, Steve, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : TRY temporarily in place
|
Tue Apr 9 21:27:48 2013, Jenne, Update, 40m Upgrading, TRY temporarily in place
|
Tue Nov 10 19:25:42 2015, gautam, Update, General, FS725 Rubidium reference
|
Tue Dec 22 16:44:03 2015, gautam, Update, General, FS725 Rubidium reference - REPAIRED
|
Wed Dec 23 03:27:04 2015, rana, Update, Computer Scripts / Programs, LHO EPICS slow down
|
Wed Dec 23 15:43:02 2015, rana, Summary, PSL, PMC FSS IMC RF summing box
|
Sat Dec 26 10:34:43 2015, Steve, Update, General, today
|
Mon Jan 4 14:45:41 2016, rana, eq, koji, Configuration, Computer Scripts / Programs, nodus pwd change
|
Mon Oct 26 19:10:59 2015, gautam, Update, Green Locking, AUX PDH loop characterization
|
Tue Dec 8 23:24:08 2015, gautam, Update, Green Locking, Y end laser (Lightwave) PZT calibration
|
Sun Dec 13 21:55:28 2015, gautam, Update, Green Locking, Y end laser (Lightwave) PZT calibration   
|
Mon Dec 14 16:27:11 2015, gautam, Update, Green Locking, Y-end AUX PDH noise breakdown 
|
Mon Jan 4 16:45:11 2016, gautam, Update, Green Locking, Y-end AUX PDH noise breakdown  
|
Mon Jan 4 16:09:54 2016, gautam, Update, Green Locking, Y end laser (Lightwave) PZT calibration 
|
Wed Jan 6 08:09:04 2016, Steve, Update, PEM, 4.5 Mag Banning EQ
|
Tue Jan 12 07:54:23 2016, Steve, Update, SUS, ETMX damping restored
|
Thu Dec 17 01:55:16 2015, ericq, Update, LSC, Uncooperative AUX X
|
Fri Dec 18 17:37:04 2015, rana, Update, LSC, Uncooperative AUX X
|
Mon Dec 21 02:29:49 2015, ericq, Update, LSC, AUX X RIN measurements
|
Tue Jan 5 02:54:38 2016, ericq, Update, LSC, AUX X Freq Noise attempt
|
Tue Jan 5 13:17:06 2016, rana, Update, LSC, AUX X Freq Noise attempt
|
Tue Jan 5 16:33:45 2016, ericq, Update, LSC, AUX X Freq Noise attempt
|
Thu Jan 7 04:28:39 2016, ericq, Update, LSC, AUX X Freq Noise measured 
|
Thu Jan 7 16:52:32 2016, ericq, Update, LSC, AUX X Freq Noise measured 
|
Thu Jan 7 19:04:25 2016, Koji, Update, LSC, AUX X Freq Noise measured
|
Fri Jan 8 14:47:33 2016, ericq, Update, LSC, AUX Y Freq Noise measured 
|
Fri Jan 8 20:02:49 2016, rana, Update, LSC, AUX Y Freq Noise measured
|
Sat Jan 9 00:39:15 2016, gautam, Update, LSC, AUX Y Freq Noise re-measured
|
Mon Jan 11 19:01:56 2016, gautam, Update, LSC, PLL Marconi Investigation 6x
|
Tue Jan 12 03:03:55 2016, ericq, Update, LSC, Frequently making noise
|
Tue Jan 12 19:38:31 2016, gautam, Update, LSC, Frequently making noise    
|
Wed Jan 13 18:36:00 2016, gautam, Update, LSC, restoration of green beat electronics
|
Mon Dec 14 16:46:42 2015, ericq, Update, WienerFiltering, Noise Subtraction Puzzler
|
Thu Jan 7 15:29:54 2016, ericq, Update, WienerFiltering, Noise Subtraction Puzzler 
|
Thu Jan 14 15:08:37 2016, ericq, Update, WienerFiltering, Noise Subtraction Puzzler
|
Thu Jan 14 18:41:36 2016, rana, Update, WienerFiltering, Noise Subtraction Puzzler
|
Mon Feb 3 15:57:52 2014, Steve, Update, Green Locking, ETMX green power 
|
Tue Feb 4 01:02:03 2014, Koji, Update, Green Locking, ETMX green power
|
Tue Jan 19 17:27:58 2016, gautam, Update, Green Locking, AUX X power investigations
|
Thu Jan 14 02:33:37 2016, ericq, Update, LSC, ALSX Noise still anomalously high 
|
Tue Jan 19 17:54:39 2016, gautam, Update, LSC, ALSX Noise still anomalously high 
|
Wed Jan 20 02:53:18 2016, ericq, Update, LSC, Hopeful signs
|
Thu Jan 21 00:02:11 2016, Koji, Update, LSC, Hopeful signs
|
Wed Jan 20 23:26:10 2016, gautam, rana, Update, LSC, PSL and AUX-X temperatures changed
|
Thu Jan 21 18:34:04 2016, rana, Update, LSC, PSL and AUX-X temperatures changed
|
Fri Jan 22 01:56:01 2016, ericq, Update, LSC, Audio ALSX
|
Fri Jan 22 11:33:20 2016, gautam, Update, Green Locking, AUX-X AM/PM investigations  
|
Fri Jan 22 13:33:37 2016, ericq, Update, Green Locking, AUX-X AM/PM investigations
|
Fri Jan 22 17:22:06 2016, gautam, Update, Green Locking, AUX-X AM/PM investigations 
|
Fri Jan 22 18:46:03 2016, rana, Update, Green Locking, AUX-X AM/PM investigations
|
Tue Jan 26 15:07:47 2016, Steve, Update, PEM, accelerometers moved to ETMX 
|
Wed Jan 27 08:17:38 2016, Steve, Update, PEM, ETMX floor vs table noise 6x
|
Wed Jan 27 20:51:00 2016, rana, Update, PEM, ETMX floor vs table noise
|
Wed Jan 27 23:14:25 2016, gautam, Update, PEM, ETMX floor vs table noise 
|
Thu Jan 28 14:54:49 2016, ericq, Update, LSC, Status of the green PDH circuits
|
Thu Jan 28 19:10:16 2016, gautam, Update, LSC, Status of the green PDH circuits
|
Mon Feb 1 14:08:06 2016, Steve, Update, PEM, roof condtion is good
|
Wed Feb 3 08:39:17 2016, Steve, Update, CDS, blank daily summary pages
|
Thu Feb 4 10:19:05 2016, Steve, Update, safety, fire marshal inspection
|
Mon Dec 28 14:12:23 2015, Steve, Update, SUS, 4.2M EQ 
|
Wed Dec 30 11:09:52 2015, Steve, Update, SUS, 4.4M EQ 
|
Thu Jan 14 13:44:05 2016, Steve, Update, SUS, earthquake 3.6M 
|
Tue Jan 19 10:25:53 2016, Steve, Update, SUS, EQ 3.6M Ludlow
|
Wed Jan 20 09:36:11 2016, Steve, Update, SUS, ETMX damping restored
|
Mon Jan 25 08:36:46 2016, Steve, Update, SUS, PRM damping restored  
|
Thu Feb 4 10:14:52 2016, Steve, Update, SUS, earthquake 3.5M
|
Mon Feb 8 09:37:07 2016, Steve, Update, SUS, EQ 3.9m
|
Wed Feb 17 09:05:07 2016, Steve, Update, VAC, forepump replaced
|
Thu Feb 18 02:52:27 2016, ericq, Update, IOO, Some housekeeping
|
Fri Sep 23 16:25:01 2011, steve, Update, VAC, vac rack UPS battery replaced 
|
Fri Mar 27 10:38:40 2015, steve, Update, VAC, vac rack UPS battery replaced
|
Tue Mar 1 09:37:15 2016, steve, Update, VAC, vac rack UPS batteries replaced
|
Fri Mar 4 13:52:41 2016, ericq, Update, IOO, PSL Laser Opened
|
Sat Mar 5 10:37:48 2016, rana, Update, IOO, PSL Laser Opened
|
Sun Mar 6 15:24:05 2016, gautam, Update, CDS, FB down again
|
Mon Mar 7 20:40:02 2016, ericq, Update, CDS, FB down again
|
Tue Feb 2 18:35:47 2016, gautam, Update, Green Locking, Lightwave NPRO moved from PSL table to SP table
|
Tue Feb 2 18:54:02 2016, Koji, Update, Green Locking, Lightwave NPRO moved from PSL table to SP table
|
Wed Feb 3 23:23:47 2016, gautam, Update, Green Locking, Lightwave NPRO moved from PSL table to SP table 
|
Thu Feb 4 09:16:46 2016, Koji, Update, Green Locking, Lightwave NPRO moved from PSL table to SP table
|
Fri Feb 5 00:23:01 2016, gautam, Update, Green Locking, Lightwave NPRO moved from PSL table to SP table   
|
Fri Feb 5 16:50:24 2016, gautam, Update, Green Locking, First pass at mode-matching   
|
Mon Feb 8 15:36:37 2016, gautam, Update, Green Locking, Alternative mode-matching scheme
|
Tue Feb 9 04:37:10 2016, ericq, Update, Green Locking, Laser swap initiated
|
Tue Feb 9 11:49:47 2016, gautam, Update, Green Locking, Laser swap initiated
|
Tue Feb 9 19:15:36 2016, gautam, Update, Green Locking, Laser swap - updates 
|
Wed Feb 10 17:57:15 2016, gautam, Update, Green Locking, Laser swap - updates
|
Fri Feb 12 17:05:40 2016, gautam, Update, Green Locking, Laser swap - green light recovered but no flashes in the arm
|
Fri Feb 12 19:07:52 2016, Koji, Update, Green Locking, Laser swap - green light recovered but no flashes in the arm
|
Fri Feb 19 00:42:19 2016, gautam, Update, Green Locking, Laser swap - beam ellipticity from laser?  
|
Mon Feb 22 13:56:52 2016, gautam, Update, Green Locking, Laser swap -reflected beam from ETM aligned
|
Tue Feb 23 23:01:16 2016, gautam, Update, Green Locking, Laser swap - Green PDH locking 
|
Wed Feb 24 19:29:13 2016, gautam, Update, Green Locking, Laser swap - Green PDH locked
|
Fri Feb 26 01:52:44 2016, gautam, Update, Green Locking, Laser swap - Green PDH OLTF
|
Mon Feb 29 17:17:26 2016, gautam, Update, Green Locking, Laser swap - still no green beatnote
|
Wed Mar 2 17:42:19 2016, gautam, Update, Green Locking, Laser swap - some progress
|
Thu Mar 3 01:25:50 2016, gautam, Update, Green Locking, Laser swap - 2 IR + 1 green beatnotes found
|
Fri Mar 4 01:11:41 2016, gautam, Update, Green Locking, Laser swap - both green beatnotes found
|
Sat Mar 5 23:31:01 2016, gautam, Update, Green Locking, Laser swap - some updates    
|
Mon Mar 7 23:51:36 2016, gautam, Update, Green Locking, Laser swap - some improvement   
|
Tue Mar 8 18:22:20 2016, rana, Update, Green Locking, Laser swap - some improvement
|
Thu Mar 10 03:03:11 2016, ericq, Update, LSC, DRFPMI Power stable, but no RF handoff
|
Sat Mar 12 22:23:37 2016, rana, Summary, IOO, PMC relocked
|
Wed Mar 16 15:36:03 2016, Steve, Update, SUS, wire standoff test cut
|
Wed Mar 16 16:02:40 2016, Koji, Update, SUS, wire standoff test cut
|
Fri Mar 18 11:04:56 2016, Steve, Update, SUS, inverted pendulum
|
Mon Mar 21 10:07:45 2016, Steve, Update, SUS, ETMX enclosure update
|
Tue Mar 15 10:31:58 2016, Steve, Update, IOO, Laser is turned back on
|
Tue Mar 22 14:12:18 2016, Steve, Update, IOO, Laser is turned back on
|
Mon Mar 11 10:20:36 2013, Max Horton, Summary, Computers, Attempted Smart UPS 2200 Battery Replacement 
|
Thu Jun 6 15:46:10 2013, Max Horton, Summary, General, Smart UPS 2200 Batteries Replaced
|
Wed Mar 23 11:55:47 2016, Steve, Update, General, Smart UPS 2200 Battery Replaced
|
Sat Mar 26 18:28:24 2016, Koji, Update, elog, elogd flakiness
|
Mon Mar 28 08:30:09 2016, Steve, Update, SUS, PRM damping restored
|
Mon Sep 29 11:17:14 2008, steve, Update, SAFETY, horizontal viewports are protected with lexan
|
Wed Mar 30 11:35:24 2016, steve, Update, safety, BS visitor's viewport is protected with lexan
|
Fri Apr 1 13:11:26 2016, ericq, Update, WienerFiltering, Bilinear Noise Testing 
|
Thu Mar 10 16:29:32 2016, gautam, Update, endtable upgrade, Inventory check 
|
Thu Mar 10 16:32:45 2016, rana, Update, endtable upgrade, Inventory check
|
Mon Mar 14 22:42:23 2016, gautam, Update, endtable upgrade, Inventory check
|
Mon Mar 28 10:43:18 2016, Steve, Update, endtable upgrade, ETMX 4'x2' optical table pictures  
|
Wed Mar 30 17:38:52 2016, gautam, Update, endtable upgrade, X end table proposed layout  
|
Thu Mar 31 09:38:41 2016, Steve, Update, endtable upgrade, Y end 4x3 existing layout
|
Thu Mar 31 19:49:31 2016, gautam, Update, endtable upgrade, proposed layout v2
|
Mon Apr 4 10:59:12 2016, gautam, Update, endtable upgrade, proposed layout v3    
|
Mon Apr 4 15:04:14 2016, gautam, Update, endtable upgrade, COMPONENT REMOVAL
|
Tue Apr 5 11:42:17 2016, gaericqutam, Update, endtable upgrade, TABLE REMOVAL
|
Wed Apr 6 17:52:21 2016, gautam, Update, endtable upgrade, First contact cleaning commenced
|
Thu Apr 7 12:51:24 2016, gautam, Update, endtable upgrade, Beam height differences
|
Thu Apr 7 14:30:58 2016, Steve, Update, endtable upgrade, ETMX table height    
|
Fri Apr 8 09:13:20 2016, Steve, Update, endtable upgrade, ETMX-T beam height 
|
Tue Mar 29 03:16:21 2016, ericq, Update, LSC, DRFPMI Locked Once More  
|
Wed Mar 30 16:40:24 2016, ericq, Update, LSC, 2016 vs 2010
|
Mon Apr 11 16:06:30 2016, ericq, Update, LSC, DRFPMI Data Archived
|
Tue Jan 26 17:50:22 2016, gautam, Update, Green Locking, Lightwave frequency noise measurement
|
Wed Jan 27 18:19:45 2016, gautam, Update, Green Locking, Lightwave frequency noise measurement
|
Thu Jan 28 00:29:30 2016, gautam, Update, Green Locking, Lightwave frequency noise measurement 
|
Mon Feb 1 18:11:25 2016, gautam, Update, Green Locking, Lightwave frequency noise measurement
|
Fri Jan 29 14:43:47 2016, Steve, Update, Green Locking, Innolight laser is 10 years old
|
Fri Jan 29 16:55:27 2016, rana, Update, Green Locking, Innolight laser is 10 years old
|
Sat Jan 30 00:12:22 2016, gautam, Update, Green Locking, Innolight laser is 10 years old
|
Sat Jan 30 09:56:24 2016, Koji, Update, Green Locking, Innolight laser is 10 years old
|
Mon Feb 1 15:16:28 2016, gautam, Update, Green Locking, Innolight laser is 10 years old
|
Mon Feb 1 15:43:18 2016, Koji, Update, Green Locking, Innolight laser is 10 years old
|
Fri Feb 5 15:02:13 2016, gautam, Update, Green Locking, X-end NE cable
|
Fri Feb 12 11:10:49 2016, Steve, Update, Green Locking, Innolight laser is 10 years old
|
Mon Mar 21 14:29:32 2016, Steve, Update, Calibration-Repair, 1W Innolight laser repair diagnoses
|
Thu Mar 24 07:56:09 2016, Steve, Update, Calibration-Repair, NO Noise Eater for 1W Innolight
|
Mon Apr 11 17:03:41 2016, Steve, Update, Calibration-Repair, 1W Innolight repair completed
|
Tue Mar 22 21:30:15 2016, Koji, Update, IOO, PMCIMC aligned, WFS offset adjusted
|
Tue Apr 12 22:41:00 2016, Koji, Update, IOO, PMC/IMC aligned, WFS offset adjusted
|
Thu Apr 14 17:30:18 2016, ericq, Update, General, PLL measurement ongoing
|
Fri Apr 15 03:02:44 2016, ericq, Update, General, New AUX laser measurements  
|
Fri Apr 15 18:35:57 2016, gautam, Update, General, New AUX laser measurements 
|
Fri Apr 15 23:11:49 2016, gautam, Update, General, Innolight 1W moved to SP table
|
Mon Apr 18 00:29:00 2016, gautam, Update, General, Beam profiling + injection current scan 6x
|
Fri Mar 11 16:52:53 2016, Steve, Update, PEM, leaky roof 
|
Fri Apr 22 13:58:13 2016, Steve, Update, PEM, leaky roof is fixed
|
Wed Apr 27 09:05:10 2016, Steve, Update, General, AP viewport  
|
Mon Apr 25 11:07:06 2016, Steve, Update, SUS, spare SOS tower
|
Wed Apr 27 09:45:56 2016, rana, Update, SUS, spare SOS tower
|
Wed Apr 27 14:06:31 2016, rana, Summary, General, meeting notes
|
Thu Apr 28 08:49:47 2016, Steve, Update, PEM, possible noise sources schedule
|
|