  4554   Thu Apr 21 21:24:41 2011 kiwamuUpdateLSCdemod board : new 90 deg splitterA
new 90 degree splitter, PSCQ-2-51W, has arrived
today and I installed it on a demod board
 DSC_2949_ss.jpgDSC_2951.JPGDSC_2952_ss.jpg 
  4555   Thu Apr 21 21:46:22 2011 kiwamuUpdateLSCdemod board : new 90 deg splitterA less
LO power dependence on the relative phase
 relativephase.png 
  4556   Fri Apr 22 02:10:53 2011 ZachUpdateelogrestartedRestarted the elog with the script.   
  4557   Fri Apr 22 09:05:53 2011 SureshUpdateRF SystemRF Source Harmonics
As seen in the previous measurement the first
harmonic of both the 11 MHz and 55 MHz outputs
  
  4558   Fri Apr 22 09:25:43 2011 SureshUpdateRF SystemRF Source: Temperature sensor relocatedRF Amp operating temperature
Earlier measurement reported by Alberto
in LIGO-T10004-61-v1 based on the LM34 temperature
 P4220056.JPG 
  4559   Fri Apr 22 10:28:22 2011 ranaUpdateRF SystemRF Source HarmonicsYou should be able to resolve the other harmonics
by [B][COLOR=blue]decreasing the IF BW or
RBW[/COLOR][/B] on the analyzer. Even though
  
  4560   Fri Apr 22 11:08:50 2011 kiwamuUpdateLSCdemod board AS11 : amplitude imbalanceAmplitude
imbalance between I and Q in a demod board,
 IQamplitude.png 
  4561   Fri Apr 22 12:07:38 2011 josephb, steveUpdateCDSRemoved hanging D-sub to SCSI in 1X2Problem:
Way back, Jay had D-sub
to SCSI adapters made to adapt our existing
Sander box AA filters to the new SCSI based
  
  4562   Sun Apr 24 21:37:40 2011 kiwamuUpdateIOOreview of triple resonant EOM : model looks fineTo design a new resonant EOM box I started
reviewing the prototype that I've built.
 As a part of reviewing I checked
 Input_impedance.pngEOMcircuitmodel.png 
  4567   Mon Apr 25 22:38:49 2011 kiwamuUpdateLSCprepration for DRMI : Y arm flashingThis
week is going to be a recycled Michelson
  
  4568   Tue Apr 26 01:20:02 2011 ranaUpdateElectronicsPOX_11 debuggingThe performance plots for   
  4569   Tue Apr 26 22:03:49 2011 ranaUpdateElectronicsPOX_11 debuggingI used the Jenne AM laser to tune up the
PD (used to be POX_11 but now is called REFL_11).
In addition to the notch at 22 MHz, I have
 MM7.png 
  4570   Tue Apr 26 22:56:01 2011 kiwamuUpdateLSCc1iscaux2 and c1iscaux restratedWhile checking whitening filters on the
LSC rack, I found some epics controls for
the whitening looked not working.
  
  4571   Tue Apr 26 22:56:35 2011 ZachUpdateelogrestarted with script   
  4572   Wed Apr 27 15:34:38 2011 kiwamuUpdateElectronicsAS55 demod board with new 90 deg splitter : healthy
A new 90 deg splitter, PSCQ-2-51W,
  
  4573   Wed Apr 27 17:38:01 2011 kiwamuUpdateElectronicsRe : AS55 demod board with new 90 deg splitter : healthy   relativephase.pngIQamplitude.png 
  4574   Wed Apr 27 18:14:48 2011 kiwamuUpdateLSCpreparation for DRMI locking : RF status   RF_Work_Status.png 
  4576   Wed Apr 27 21:08:08 2011 ranaUpdateLSCAS11I worked
on AS_11 today. Its ready for its noise /
 AS11.png 
  4577   Wed Apr 27 21:19:25 2011 kiwamuUpdateLSCLSC whitening for PD1-4On
the back side of 1Y2 rack I found a cable,
CAB-1X2-LSC_7, which is supposed to be connected
 Screenshot-1.png 
  4578   Thu Apr 28 06:46:30 2011 SureshUpdateRF SystemRF Source installedRF Source
box has been mounted in the 1X2 rack. 
 P4280064.JPG 
  4579   Thu Apr 28 07:14:34 2011 SureshUpdateRF SystemRF Distribution box installedRF Distribution box has been mounted in
the 1Y2 rack and is ready for use.
 
 P4280066.JPG 
  4580   Thu Apr 28 10:53:50 2011 josephbUpdateCDSAdventures in Hyper-threadingWhat was done:
1) Turn off MC1,
MC2, MC3, BS, ITMX, ITMY, PRM, SRM watchdogs.
2) Turn c1sus computer off (sudo
  
  4581   Thu Apr 28 12:25:11 2011 josephbUpdateCDSFurther adventures in Hyper-threadingFirst, I disabled front end starts on boot
up, and brought c1sus up.  I rebuilt
the models for the c1sus computer so they
  
  4582   Thu Apr 28 15:31:36 2011 kiwamuUpdateIOOMC PDH lock : readjustment of demodulation phaseSince Suresh has installed the RF source
box and changed the cable configuration somewhat,
 
 DSC_2975_ss.jpg 
  4583   Thu Apr 28 16:12:19 2011 josephb, jamieUpdateCDSNew CDS model SVNNew SVN
We are now using the
LIGO CDS SVN for storing our control models.
The SVN is at:
  
  4584   Thu Apr 28 22:38:38 2011 AidanUpdateGreen LockingElectronics schematic for vertex beatbox With some assistance from Kiwamu
and Koji, I've drawn up the electronics design
for the Beat Box for the vertex green locking.
 Canvas_1.pngCanvas_2.png 
  4586   Fri Apr 29 05:48:52 2011 kiwamuUpdateLSCY arm lockedThe
Y arm has been locked with the IR beam. The
purpose is to use the arm as an alignment
 DSC_2978_ss.jpg 
  4587   Fri Apr 29 12:18:48 2011 kiwamuUpdateLSCY arm locked : detailsFirst of all, the conclusions / results
from the exercise of the Y arm locking yesterday
are:
  
  4588   Fri Apr 29 13:15:04 2011 kiwamuUpdateLSCY arm locked : detailsAs far as I know, this button works only
once after the launch of MEDM...

  
  4589   Fri Apr 29 13:58:36 2011 ranaUpdateLSCY arm locked : details

    
        
  
  4590   Fri Apr 29 14:36:36 2011 josephb, steveUpdateCDSRemoved hanging D-sub to SCSI in 1X5

    

       
            
 P1070621.JPG 
  4591   Fri Apr 29 18:24:05 2011 SureshUpdateRF SystemRF system: 1X2 Rack cabling[Joe, Jamie, Suresh]
We have installed the IDE to SCSI
adaptor module into the 1X2 rack and have
 P4290070.JPG 
  4592   Sat Apr 30 00:15:26 2011 kiwamuUpdateSUSDRMI prep : suspension diagnosticAs a part of the DRMI preparation,
I leave all
  
  4593   Sat Apr 30 05:14:33 2011 KojiUpdateGreen LockingElectronics schematic for vertex beatbox- AC coupling for the comparator
circuit of the green locking
In order to relieve the power consumption
 freq_divider.png 
  4594   Mon May 2 11:14:27 2011 kiwamuUpdateSUSscript : opticshutdownJust FYI.
There is a useful script for this
particular job : shutting down all the suspensions
  
  4595   Mon May 2 12:51:52 2011 kiwamuUpdateLSCPRMI locking : planToday we will try to
lock the PRMI. 
  
  4596   Mon May 2 13:30:13 2011 kiwamuUpdateSUSPRMI locking prep: PRM oplevI had a quick look at PRM optical lever.
The He-Ne beam is still successfully
coming out from the chamber and I could guide
  
  4598   Mon May 2 15:53:27 2011 kiwamuUpdateLSCPRMI locking prep : demodulation boardsI swapped the name of two demodulation
boards (AS55 and REFL55).
Now
 RF_Work_Status.png 
  4599   Mon May 2 17:10:55 2011 steveUpdateSUSPRM oplevThe returning spot diameter on the qpd
~10 mm. In order to reduce the spot size
I moved the f 1145 mm lens toward the PRM
  
  4600   Mon May 2 18:16:24 2011 kiwamuUpdateLSCPRMI locking : status update(done)
- AS55 RFPD
  With a help from Jamie the
  
  4601   Mon May 2 21:14:55 2011 kiwamuUpdateElectronicstoo loose Heliax connectors on 1Y2 rackI found that
all the Heliax cables landing on the bottom
 DSC_2982_ss.jpgDSC_2984_ss.jpg 
  4602   Mon May 2 23:29:57 2011 SureshUpdateElectronicstoo loose Heliax connectors on 1Y2 rackThe countersink
gives rise to another problem when we mount
the N-type-to-SMA bulkhead adaptor. 
  
  4604   Tue May 3 03:53:20 2011 kiwamuUpdateLSCPRMI locking : doneThe PRMI has been successfully
locked 
 PRMI_locking.png 
  4605   Tue May 3 04:09:53 2011 KojiUpdateLSCREFL55 PD update[Rana, Koji]
REFL55 was modified. The noise level
confirmed. The PD is now ready to be installed.
 REFL55.pdf 
  4606   Tue May 3 05:32:04 2011 kiwamuUpdateLSCdaytime tasksDaytime tasks : 
 - PRM & BS oplev (Steve)
  
  4607   Tue May 3 10:21:25 2011 KojiUpdateLSCdaytime tasksI think the installation of the PD DC
signals are quite important. What to do
1) Connect the DC signals to the right
  
  4608   Tue May 3 10:41:35 2011 josephbUpdateCDSMorning maintenance1) Filled in the C1SUS_BS_OLMATRIX properly
so as to make the BS oplev work for Steve.
2) Turned on the ITMX damping. 
  
  4609   Tue May 3 10:59:31 2011 josephbUpdateCDS1Y2 binary output adapter board now poweredI temporarily turned off the power to the
1Y2 rack this morning while wiring in the
binary output adapter board power (+/- 15V)
  
  4610   Tue May 3 11:49:03 2011 KojiUpdateLSCdaytime tasksDone. C1:PSL-PMC_PMCTRANSPD was improved
from ~0.75 to 0.87.

  
  4611   Tue May 3 13:22:13 2011 LeoUpdateSUSRe: DRMI prep : suspension diagnosticHere are the free-swinging spectra for
the BS, ETMX, ETMY, ITMX, ITMY, MC1, MC2,
MC3, and PRM chambers.  Kiwamu left
 10x 