  6696   Tue May 29 00:35:57 2012 DenUpdatePEMguralp readout boxI measured the frequency response of the
Guralp readout box and noise by providing
sin signal of amplitude 50 mV at 15 Hz for
 1_3.png 
  6697   Tue May 29 00:39:52 2012 DenUpdatePEMGuralp noiseI've connected Guralp output to the ADC
without readout box. I've got the same noise
at low frequencies and even worse noise at
 in_out.png 
  6698   Tue May 29 00:48:51 2012 DenUpdatePEMsts readout boxSTS readout box seems to be partly broken.
I've terminated inputs from the seismometer
and measured the output. I could not do this
 sts_box.png 
  6699   Tue May 29 00:53:57 2012 DenUpdateCDSproblemsI've noticed several CDS problems:

    Communication sign on
C1SUS model turns to red once in a while.
  
  6700   Tue May 29 10:08:21 2012 steveUpdateIOOcentered IOO monitoring qpdsIOO Angle & IOO Position QPDs centered.  40dtrendIOO.pngIOOcentered.png 
  6701   Tue May 29 14:58:28 2012 JenneUpdateLockingETMX trans camera...will be helpful for acquiring lock after
the vent.  We should install a camera
at ETMX.
  
  6702   Tue May 29 14:59:39 2012 JenneUpdateIOOPMC, MC alignment are shit[Yuta, Jenne]
PMC and MC alignment are both shit,
although with the WFS on, the MC is pretty
  
  6703   Tue May 29 15:29:16 2012 JamieUpdateComputerslatest pynds installed on all new control room machinesThe DASWG lscsoft package repositories
have a lot of useful analysis software. 
It is all maintained for Debian "sqeeze",
  
  6704   Tue May 29 15:48:31 2012 KojiUpdateIOOPMC, MC alignment are shitThe followings are a kind of daily check.
Do this without any notice:
- Align PMC.
  
  6705   Tue May 29 15:49:02 2012 KojiUpdateLockingETMX trans camera

    

       
            
  
  6706   Tue May 29 15:55:22 2012 steveUpdateSUSETMY oplev spot size reduced

    

       
            
 ETMYoplev.jpgIMG_1243.JPG 
  6707   Tue May 29 17:40:45 2012 JenneUpdateIOOPMC, MC alignment are shit

    

       
            
  
  6708   Tue May 29 19:50:01 2012 JenneUpdateIOOPMC, MC alignment are shit

    

       
            
  
  6709   Tue May 29 21:05:30 2012 yutaUpdateIOOPMC, MC alignment are shit

    

       
            
  
  6710   Tue May 29 21:34:08 2012 JenneUpdateSUSETMY oplev spot size reduced

    

       
            
  
  6711   Tue May 29 21:50:21 2012 JenneUpdateLockingYarm error spectraThe ~16Hz bounce mode of some optic is
showing up in the Yarm error signal. 
MC is kind of 'windy' looking, so
 LSC_POY_11_I_ERR_29May2012.pdf 
  6712   Tue May 29 22:48:37 2012 DenUpdatePEMGuralp noiseI've checked whether the Guralp noise that
we see comes not from seismometer but from
ADC or readout box. I did 2 separate measurements
 split_noises.png 
  6713   Wed May 30 01:35:15 2012 yutaUpdateGreen Lockingaligned Y arm green beam[Jenne, Yuta]
We aligned the Y arm for IR (C1:LSC-TRY_OUT
is now ~ 0.9), and aligned the green beam
  
  6714   Wed May 30 13:24:08 2012 JenneUpdateLockingYarm error spectra

    

       
            
  
  6715   Wed May 30 15:51:22 2012 yutaUpdateIOOMC beam spot oscillation[Koji, Suresh, Jenne, Yuta]
Background:
  We noticed that the beam spots
 specMC3_onoff_localdamping.pdf 
  6716   Wed May 30 18:08:40 2012 JamieUpdateLSCc1lsc: add error point pick-offs, moved ctrl pick-offs after feedforwardI made some modifications to the c1lsc
model in order to extract both the error
and control signals.
 LSCchain.png 
  6717   Wed May 30 18:16:44 2012 JamieUpdateLSCskeleton of new c1cal calibration model created[Jamie, Xavi Siemens, Chris Pankow]
We built the skeleton of a new calibration
model for the LSC degrees of freedom. 
  
  6718   Wed May 30 19:27:38 2012 yutaUpdateIOOMC beam spot oscillation[Koji, Yuta]  
We found that C1:SUS-MC{1,2,3}_TO_COIL_3_4_GAIN
  
  6719   Wed May 30 20:12:15 2012 ranaUpdateIOOMC beam spot oscillationThis is a common occurrence when diagnostic
scripts are written without the ability to
handle exceptions (e.g. ctrl-c, terminal
  
  6720   Wed May 30 22:04:13 2012 JenneBureaucracyGeneral40m Action Items.....including:
fix Q of Vio2 filter in SUS. - JENNE
Switch power source for beatnote
  
  6721   Wed May 30 22:51:32 2012 DenUpdatePEMguralp isolation boxWhen I've put Guralps inside the isolation
box, the signal from seismometers increased
and was out of AA board range. I've reduced
 lin_box_noise.png 
  6722   Thu May 31 00:56:13 2012 JamieMetaphysicsComputersPlease remember to check in code changesI know it's really hard to remember, but
our future selves will thank us dearly if
we remember to commit all of our code changes
  
  6723   Thu May 31 01:20:41 2012 JenneUpdateASSASS filter outputs are non-zero with no inputI was looking a little at ASS, while Yuta
was doing some Green transmitted DC PD work,
and I find that the output of some filters
 ASS_Yarm_crazyOutputs_30May2012.png 
  6724   Thu May 31 01:27:16 2012 yutaUpdateGreen LockingPSL and Y arm green beams aligned[Jenne, Yuta]
We aligned the PSL green optics so
that the PSL green beam and Y arm green beam
  
  6725   Thu May 31 01:36:17 2012 yutaUpdateGreen LockingGREEN_TRX/GREEN_TRY PDsI did the cabling for monitoring DC transmission
of the green beam from the end table.
The two PDs are called GREEN TRX and
  
  6726   Thu May 31 02:27:24 2012 yutaUpdateIOOscript for reliefing MC WFSI wrote a simple script for reliefing MC
WFS servo. The script is located at /opt/rtcds/caltech/c1/scripts/MC/reliefMCWFS.
  
  6727   Thu May 31 04:03:17 2012 yutaUpdateIOOscript for MC beam spot measurementI wrote a wrapping script for measuring
MC beam spot. We had to run several scripts
for the measurement (see elog #6688),
  
  6728   Thu May 31 10:31:19 2012 JamieUpdateIOOMC beam spot oscillation

    

       
            
  
  6729   Thu May 31 11:02:14 2012 steveUpdateLockingETMX 1064 trans camera

    

       
            
  
  6730   Thu May 31 11:38:19 2012 DenUpdatePEMisolation systemI've put Guralps into the Steve's 2 box
isolation system. Noise got better, coherence
between 2 seismometers improved. We still
 lin_box_noise2.pnglin_box_coh.png 
  6731   Thu May 31 16:19:07 2012 yutaUpdateGreen Lockingtemperature setting for PSL doubling crystalI fixed the temperature control of the
oven for the PSL doubling crystal.
The PID settings were not good, and
  
  6732   Thu May 31 16:54:12 2012 JenneUpdateGreen LockingLinks to old elogs for green beatnote laser tempsBecause I keep taking a long time to search
for these, since I can't remember the keywords
in the different entries, here are the links:
  
  6733   Thu May 31 17:47:25 2012 SureshOmnistructureGeneral40m Wireless NetworkMike Pedraza came by today to install a
new wireless network router configured for
the 40m lab network.  It has a 'secret'
 40m_Wifi.png 
  6734   Thu May 31 22:13:08 2012 JamieUpdateCDSc1lsc: added remaining SHMEM senders for ERR and CTRL, c1oaf model updated appropriatelyAll the ERR and CTRL outputs in c1lsc now
go to SHMEM senders.  I renamed the
the CTRL output SHMEM senders to be more
 lsc-shmem-out.png 
  6735   Thu May 31 23:53:00 2012 JenneUpdateLSCLSC trigger updateI modified the lsc model (after Jamie finished)
to use a new triggering scheme.  It
HAS NOT yet been compiled and tested, since
  
  6736   Fri Jun 1 02:13:00 2012 JenneUpdateGreen LockingAttempt at Ygreen beat - failed[Yuta, Jenne]
We tried to find the Ygreen beat
note, with no success yet.  We calculate
  
  6737   Fri Jun 1 02:33:40 2012 JenneUpdateComputersc1sus and c1iscex - bad fb connectionsSomething bad happened to c1sus and c1iscex
~20 min ago.  They both have "0x2bad"
's.  I restarted the daqd on the framebuilder,
  
  6738   Fri Jun 1 08:01:46 2012 steveUpdateComputersc1sus and c1iscex are down

    

       
            
 compdown.png 
  6739   Fri Jun 1 08:17:47 2012 steveUpdateIOOPMC trends

    

       
            
 PMC400d.pngPMC1200d.png 
  6740   Fri Jun 1 09:50:50 2012 JamieUpdateComputersc1sus and c1iscex - bad fb connections

    

       
            
  
  6741   Fri Jun 1 10:00:03 2012 steveOmnistructureGeneral40m Wireless Network

    

       
            
  
  6742   Fri Jun 1 14:40:24 2012 JamieUpdateComputersc1sus and c1iscex - bad fb connections

    

       
            
  
  6743   Fri Jun 1 14:56:08 2012 JamieUpdateSUSOplevs all different, messed upFor some reason the state of the oplevs
is completely different for almost every
suspension.  They have different sets
 oplevs.png 
  6744   Fri Jun 1 18:07:32 2012 steveUpdateSUSOplevs servo values

    

       
            
  
  6745   Fri Jun 1 19:48:54 2012 ranaUpdateSUSOplevs all different, messed up 
 Its a good question, but the
answer is yes. At some level all of the OL
  