40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 12 of 341  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  560   Tue Jun 24 22:43:23 2008 ranaSummarySEIStack TF   Screenshot.png 
  561   Wed Jun 25 00:35:40 2008 KojiSummaryGeneralOptical Layout on the AP tableI have visited the AP table in order to investigate
where we are going to put the optical setup
for the abs. length meas. 
 optical_layout_ap_table.pngoptical_layout_ap_table.pdf 
  562   Wed Jun 25 01:30:19 2008 JohnSummaryIOOFrequency noise after the MCI made some (very) rough estimates of the
contribution made to the noise after the
mode cleaner by three sources.
 MC2noise080623.png 
  563   Wed Jun 25 09:46:45 2008 SharonUpdate Adaptive FiltersI have been learning about different methods
for applying adaptive filters to improve
the Mode Cleaner lock in specific, and other
  
  564   Wed Jun 25 11:01:45 2008 MashaUpdateAuxiliary lockingfiber stabilizationFor the first week, I have been learning about
fiber noise cancellation, auxiliary locking
techniques, and other relevant helpful topics
  
  565   Wed Jun 25 11:36:14 2008 Max JonesUpdateComputer Scripts / ProgramsFirst Week UpdateFor the first week I have been modifying the
noise budget script in caltech/NB to run
with 40 m parameters and data. As per Rana's
 C1_NoiseBudgetPlot_Day.epsC1_NoiseBudgetPlot_Night.eps 
  566   Wed Jun 25 12:25:28 2008 EricSummaryCameras2D Gaussian Fitting CodeI initially wrote a script in MATLAB that
takes pictures of the laser beam's profile
and fits them to a two dimensional gaussian
  
  567   Wed Jun 25 13:38:22 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Placement of the 700mW NPRO on the AP tableThis morning I have put the 700mW NPRO on
the AP table for the abs length measurement.
 NPRO700mW_placement.jpg 
  568   Wed Jun 25 13:56:56 2008 JohnSummaryLockingTuesday night lockingRob, John

Worked to try and reduce the CARM offset
  
  569   Wed Jun 25 18:03:21 2008 YoichiConfigurationPSLFSS Input Offset slider problemWhile working on the PMC scanning, I noticed
that the FSS input offset slider is doing
nothing.
  
  570   Thu Jun 26 01:08:22 2008 ranaConfigurationGeneralAlarm Handler RevivedI have revived the Alarm Handler by turning
it on on op540m and adjusting the levels
of
 b.gif 
  571   Thu Jun 26 01:10:18 2008 ranaUpdatePEMAlarm Handler indicates that dust level is high[I]In its first useful act[/I], the Alarm
Handler started beeping indicating that the
[COLOR=purple]dust particle
 Untitled.png 
  572   Thu Jun 26 10:56:15 2008 Max JonesUpdatePEMRemoved MagnetometerI removed the Bartington Magnetometer on the
x arm to one of the outside benches. I'll
be trying to determine if and how it works
  
  573   Thu Jun 26 12:30:40 2008 JohnSummaryLockingCARM on REFL_DC[COLOR=blue]Idea:[/COLOR]

Try REFL_DC as the error signal for CARM
  
  574   Thu Jun 26 14:06:00 2008 MashaUpdateGeneral500mW INNOLIGHT NPRO infoBelow is the placement of 500mW INNOLIGHT
NPRO mephisto laser. It is set up on the
Symmetric Port table. [IMG]elog:574/1[/IMG]
 500mW_NPRO.JPG 
  575   Thu Jun 26 18:24:28 2008 YoichiUpdatePSLFSS input ofset slider problem - fixedI checked the FSS servo interface board and
found that a LT1125CSW used to differentialize
offset channel was broken (no virtual short).
  
  576   Thu Jun 26 18:27:04 2008 ranaUpdateComputer Scripts / ProgramsNo Dataviewer No CryDataviewer was hanging. It would open the
Grace window but then not plot anything.
Since DTT was working
  
  577   Thu Jun 26 18:29:44 2008 JenneUpdate MC Back onlineJenne, Rob, Yoichi

I was playing with the Mode Cleaner earlier
  
  578   Thu Jun 26 20:59:22 2008 ranaUpdateComputer Scripts / ProgramsAlarm Handler[COLOR=red][SIZE=5][B]Please do not turn off
the Alarm Handler on op540m.[/B][/SIZE][/COLOR]
  
  579   Thu Jun 26 21:07:11 2008 ranaConfigurationASSdust & MC1I realized today, that yesterday while we
were trying to debug the adaptive noise canceler,
I turned
 Screenshot-2.png 
  580   Thu Jun 26 22:08:33 2008 JenneUpdateElectronics3.7MHz bandstop filter in MC Servo The 3.7MHz elliptical bandstop filter that
I made during my SURF summer is now installed
in the MC servo loop to reduce the noise
 MCLoopGainBoth.pngTP1ASpectrumBoth.pngQmonWithFilt.pngMCOut2WithFilt.png 
  581   Fri Jun 27 09:20:15 2008 steveFrogsPEMdust particle count is up & alarm handler is onThis 3 years plot show the trend of seasons.
When outside air quality goes bad ( 0.5 micron
> 1 million ) the lab follows.
 dust3y.jpg 
  582   Fri Jun 27 14:36:39 2008 JohnSummaryLocking Rob, Yoichi, John

Some progress last night:
 gettingcloser.png 
  583   Fri Jun 27 15:20:52 2008 robDAQLSC.ini file change
I removed C1:LSC-XARM_CTRL from the frames
and added C1:LSC-CARM_ERR
  
  584   Fri Jun 27 18:03:46 2008 JenneUpdateElectronicsAnother bad cable in the MC servoEric was helping me to measure the response
of the LO input on the MC's Demod board,
and when we disconnected the end of the cable
  
  585   Fri Jun 27 18:21:01 2008 JenneUpdateElectronicsResponse of the LO input on the MC demod boardThe alarm handler has been flipping out saying
that the LO input of the MC's demod board
is too low, so at Rana's suggestion, Eric
  
  586   Fri Jun 27 19:59:44 2008 JohnUpdateComputersc1iovmeC1susvme2 and C1iovme crashed which sent the
optics swinging and tripped the watchdogs.
  
  587   Sat Jun 28 03:10:25 2008 robUpdateComputersc1iovme[quote]C1susvme2 and C1iovme crashed which
sent the optics swinging and tripped the
watchdogs.
  
  588   Sat Jun 28 14:56:44 2008 JohnUpdateComputersini filesIn short, I was editing the ini files yesterday
evening, I didn't e-log it and after some
investigation this afternoon it apears
  
  589   Sat Jun 28 23:23:50 2008 JohnUpdateComputersRebootingAll of the computers are now showing green
lights.
  
  590   Sun Jun 29 02:33:28 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Optical setup (I)I have constructed the beam injection optics
for the abs length measurement.
 optical_configuration.pngoptical_layout_ap_table2.pngoptical_layout_ap_table2.pdf 
  591   Sun Jun 29 11:31:52 2008 JohnSummaryPSLISSI reduced the gain of the ISS (C1: PSL-ISS_VGAGAIN)
from 5dB to 2dB. Any higher and it constantly
saturates.
  
  592   Sun Jun 29 14:53:02 2008 robUpdateComputersRebooting[quote]All of the computers are now showing
green lights.
  
  593   Sun Jun 29 18:58:43 2008 ranaSummaryComputers1e20 is too big for AWG and/or IOVMEWhile testing out my matlab/awgstream based
McWFS diagnostic script I accidentally put
a
  
  594   Sun Jun 29 19:19:47 2008 ranaSummaryIOOTrends of the PSL/IOO Quads over 1000 daysOnly IOO POS has been working for the past
2 years. I guess we should recommission the
IOO ANG and REFL QPDs
 a.png 
  595   Sun Jun 29 19:53:26 2008 JohnSummaryPSLISS[quote]I reduced the gain of the ISS (C1:
PSL-ISS_VGAGAIN) from 5dB to 2dB. Any higher
and it constantly saturates.[/quote]
  
  596   Sun Jun 29 20:09:40 2008 JohnSummaryIOOmcup and mcdown indicatorsI edited the mcup and mcdown scripts so that
C1IFO_STATE shows when these scripts are
running.
 mcscreen.pngifostate.png 
  597   Sun Jun 29 20:29:48 2008 ranaUpdatePSLCorrelation of PSL SLOW control v. Room temperature   slowtemp.png 
  598   Mon Jun 30 01:49:06 2008 JohnUpdateIOOMC workI'm in the process of aligning the mode cleaner/
input beam.
  
  599   Mon Jun 30 05:33:38 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Optical setup (II)o The position of the iris was adjusted so
as not to disturub the beam for OMCR CCD.
  
  600   Mon Jun 30 08:59:23 2008 steveUpdateIOOIOO-MC_DEMOD_LO is lowThe alarm handler is beeping relentlessly:
asking for help in high partical count and
low demod signal
 demlo.jpg_____ 
  601   Mon Jun 30 09:46:15 2008 JohnUpdateIOOMC WFSMC WFS are on. They seem to do some good during
the day.
  
  602   Mon Jun 30 13:48:47 2008 John, RobConfigurationPSLDon't put the bin in front of the air conditioning unitWe spotted that the laser power was dropping.

[SIZE=5][COLOR=blue][FONT=Verdana]The air
 binremoval.png 
  603   Mon Jun 30 14:07:26 2008 RobConfigurationPSLDon't put the bin in front of the air conditioning unit[quote]We spotted that the laser power was
dropping.
[/quote]
 DSC_0140.png 
  604   Mon Jun 30 15:08:52 2008 JohnSummaryPSLMZ alignmentI adjusted the alignmnet of the Mach-Zehnder's
two North mirrors (downstream of the EOMs).
 mzalign.png 
  605   Mon Jun 30 15:56:22 2008 JenneUpdateElectronicsFixing the LO demod signal To make the alarm handler happy, at Rana and
John's suggestion I replaced R14 of the MC's
Demod board, changing it from 4.99 Ohms to
  
  606   Mon Jun 30 16:00:02 2008 josephb, samConfigurationComputers Sam and I setup Cat6 cable from Megatron to
the 1Y6 Switch (131.215.113.252) and also
connected the 1Y6 Hub to the control room
  
  607   Mon Jun 30 18:36:01 2008 YoichiUpdatePSLMZ alignment againJohn, Yoichi

We re-adjusted the MZ alignment. The reason
  
  608   Tue Jul 1 09:26:33 2008 steveUpdateComputersRFM network is down    
  609   Tue Jul 1 10:15:22 2008 steveUpdatePSLeventfull two daysThe laser recovered from a short temp rise.
The MZ was aligned and realigned. The suspentions
were kicked up accidentally. 
 2d.jpg 
ELOG V3.1.3-