Entry  Fri Mar 6 00:59:13 2015, rana, Summary, IOO, MC alignment not drifting; PSL beam is drifting MCdrfit.png
    Reply  Fri Mar 6 19:54:15 2015, rana, Summary, IOO, MC alignment not drifting; PSL beam is drifting Untitled.png
    Reply  Thu Mar 19 16:58:19 2015, Steve, Summary, IOO, MC alignment not drifting; PSL beam is drifting driftingInputBeam2.jpg
    Reply  Fri Mar 20 10:51:09 2015, Steve, Summary, IOO, MC alignment not drifting; PSL beam is drifting eom4.jpgeom3.jpg
    Reply  Mon Nov 4 12:59:43 2013, Jenne, Update, IOO, MC alignment not so good after PSL output shutter installed MCspots_4Nov2013.png
Entry  Fri Mar 16 16:03:03 2012, kiwamu, Update, IOO, MC alignment servo : put some offsets in the TRANS QPD signal 
Entry  Sun Feb 10 21:43:16 2008, rob, Configuration, IOO, MC alignment tweaked 
Entry  Wed Jul 7 22:58:08 2010, nancy, Update, IOO, MC alignment values. 
    Reply  Wed Jul 7 23:11:08 2010, Koji, Update, IOO, MC alignment values. 
    Reply  Thu Jul 8 20:32:22 2010, nancy, Update, IOO, MC alignment values. 
Entry  Wed Feb 16 01:03:59 2011, Jenne, Update, IOO, MC alignment work 
    Reply  Thu Feb 17 14:52:27 2011, Jenne, Update, IOO, MC alignment work 
Entry  Tue Oct 16 11:54:05 2012, Jenne, Update, IOO, MC alignment?? 
Entry  Fri May 2 02:22:56 2014, rana, Q, Update, IOO, MC alignments 
    Reply  Wed Mar 13 02:48:13 2013, Jenne, Update, IOO, MC all better 
Entry  Thu May 24 19:39:18 2012, Suresh, Update, IOO, MC and WFS alignment adjusted 
Entry  Fri Aug 1 01:57:24 2014, Koji, Summary, IOO, MC auto locker 
    Reply  Fri Aug 1 08:55:34 2014, Koji, Summary, IOO, MC auto locker MC.png
Entry  Wed Oct 31 08:38:35 2007, rana, Problem Fixed, IOO, MC autolocker 
Entry  Tue Nov 20 20:37:51 2012, Koji, Update, IOO, MC autolocker 
    Reply  Tue Jun 17 12:04:40 2014, manasa, Update, Computer Scripts / Programs, MC autolocker NOT running, FB needs some attention FE_red.png
Entry  Mon Jul 21 13:58:33 2014, ericq, Update, IOO, MC autolocker acting up 
Entry  Thu May 23 10:48:42 2013, Manasa, Update, IOO, MC autolocker and MCWFS enabled 
    Reply  Tue Oct 18 22:47:09 2011, Suresh, Configuration, IOO, MC autolocker script edited to shutdown and restart WFS loops  
Entry  Tue Nov 23 18:02:05 2021, Anchal, Update, IMC, MC autolocker shifted to python3 script running in docker 
Entry  Wed Aug 8 18:01:58 2012, Jenne, Update, IOO, MC autolocker threshold changed 
Entry  Tue Aug 3 03:15:06 2010, nancy, Update, IOO, MC back to locked mode 
Entry  Sun May 8 16:32:52 2011, valera, Update, IOO, MC beam spot centering 
    Reply  Sun May 8 17:29:01 2011, rana, Update, IOO, MC beam spot centering 
Entry  Sat May 7 18:08:54 2011, valera, Update, IOO, MC beam spot centering script mcditherlines2.pdf
Entry  Wed May 30 15:51:22 2012, yuta, Update, IOO, MC beam spot oscillation specMC3_onoff_localdamping.pdf
    Reply  Wed May 30 19:27:38 2012, yuta, Update, IOO, MC beam spot oscillation 
    Reply  Wed May 30 20:12:15 2012, rana, Update, IOO, MC beam spot oscillation 
    Reply  Thu May 31 10:31:19 2012, Jamie, Update, IOO, MC beam spot oscillation 
Entry  Mon Jun 25 15:07:49 2012, yuta, Update, IOO, MC beam spot trend MCdecenter.png
Entry  Wed Jan 4 00:43:06 2012, kiwamu, Update, IOO, MC became flaky 
    Reply  Thu May 1 14:45:44 2014, Jenne, Update, LSC, MC board back in IMG_1394.JPGIMG_1395.JPGIMG_1398.JPGIMG_1402.JPG
Entry  Mon Jun 9 23:08:58 2014, Jenne, Update, IOO, MC board checkout 
    Reply  Thu May 1 13:03:34 2014, Jenne, Update, LSC, MC board pulled for AC coupling 
Entry  Wed Mar 5 19:27:24 2014, manasa, Update, IOO, MC calmed down 
    Reply  Thu Mar 6 19:17:05 2014, manasa, Update, IOO, MC calmed down MC_spots_Mar6.png
Entry  Fri Aug 6 12:22:04 2010, Jenne, Update, IOO, MC data taking over the weekend 
    Reply  Fri Aug 6 12:44:29 2010, Koji, Update, IOO, MC data taking over the weekend 
Entry  Mon Aug 11 21:03:48 2014, ericq, rana, Summary, IOO, MC demod measurement 
    Reply  Mon Aug 11 22:07:31 2014, Koji, Summary, IOO, MC demod measurement 
    Reply  Mon Aug 11 23:32:54 2014, ericq, Summary, IOO, MC demod measurement MCDemod.pdfdemodLP.txt
Entry  Thu Jan 8 19:02:42 2015, Jax, Summary, Electronics, MC demod modifications demodprocessI.pngdemodprocessQ.pngIMG_0247.JPGIMG_0239.JPGIMG_0243.JPG
Entry  Wed Jan 12 17:22:47 2011, Suresh, Configuration, Locking, MC demod phase adjusted to minimise the I output TEK00000.PNG
    Reply  Tue Jan 7 10:44:13 2014, Steve, Update, IOO, MC drift 2dTrend.pngdriftNotKick.png
    Reply  Tue Jan 7 11:11:36 2014, rana, Update, IOO, MC drift 