40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 120 of 344  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  5994   Thu Nov 24 02:23:43 2011 KojiSummaryGeneralGPIB<->WIFIGPIB<->WIFI on Agilent Network Analyzer
4395A was broken.
The
  
  5995   Thu Nov 24 05:10:00 2011 KojiUpdateIOORFAMPD channels / EOM monitor channels added to DAQEOM TEMPMON and HEATER DRIVEMON have been
hooked up to the following channels.

C1:IOO-EOM_TEMPMON
  
  5996   Thu Nov 24 05:47:16 2011 KojiSummaryIOOStochmon runningNow stochmon for 11MHz and 55MHz is running.
The calibration / noise measurement are going
to be post later...
  
  5997   Thu Nov 24 10:27:07 2011 JenneUpdateIOORFAMPD channels / EOM monitor channels added to DAQHere is a drawing of where the monitors
are coming from:
 EOM_temp_sense_heater_drive_schematic_withMONs.png 
  5998   Thu Nov 24 12:45:12 2011 ZachUpdateIOORFAMPD channels / EOM monitor channels added to DAQJenne   
  5999   Thu Nov 24 13:54:31 2011 KojiUpdateIOORFAMPD channels / EOM monitor channels added to DAQThose clips for the readouts were the ones
who popped out. 
When I have restored the connections,
  
  6000   Thu Nov 24 14:05:10 2011 KojiUpdatePSLHEPA@50%I left the HEPA at the 50% level @5AM,
Nov 24
  
  6001   Thu Nov 24 14:42:57 2011 KojiUpdateelogelogd gained an immunity to googlebotI modified elogd.c as shown below in order
not to allow to display all of the entries
at once by specifying page number "0".
  
  6002   Thu Nov 24 15:27:15 2011 kiwamuUpdateCDSc1iscey hardware rebootedThe
c1iscey machine crashed around 1:00 AM last
night and I did a hard-ware reboot
  
  6003   Thu Nov 24 15:48:27 2011 IllustratorUpdateelogelogd gained an immunity to googlebot   elog_mario.pnggolden-monkey.jpeg 
  6004   Thu Nov 24 20:22:42 2011 MirkoUpdateIOOF2A filter for MCI calculated the F2A filters for the input
mode cleaner optics as described in T010140-01-D
eq (4). On Ranas recommendation I added an
 UpperCoils.pdfLowerCoils.pdf 
  6005   Fri Nov 25 12:46:13 2011 MirkoUpdateWienerFilteringWiener filtering tryoutTried the wiener filter with the TF from
p.5900
Tried it out with the TFs from p.5900:
 WienerFiltering.pdf 
  6006   Fri Nov 25 17:52:28 2011 ranaUpdateIOOF2A filter for MCWoo. Pretty crazy. The numerators should
only be ~10% larger than the denominator
below 1 Hz. Let's try again.
  
  6007   Fri Nov 25 18:45:31 2011 Den, RanaSummarySUSExcess Noise in Digital FilteringWe are now trying to understand why the
coherence between SUS-X_SUSPOS_IN1 and SUS-X_SUSPOS_OUT
is lost below 1 Hz for X = MC1, MC2, MC3,
 FiltNoise.png 
  6008   Fri Nov 25 19:45:36 2011 Mirco, DenSummarySUSExcess Noise in Digital Filtering


   
        
            
 sus_coh-crop.pdflsc_coh-crop.pdf 
  6009   Fri Nov 25 20:03:05 2011 KojiUpdateIOOStochmon update New RFAM mon calibration  stochmon_calib.pdf 
  6010   Fri Nov 25 20:41:48 2011 ranaUpdateSUSMC watchdogsIt seems as if someone was looking into
this on Wednesday, but as there's no elog,
I think probably not.
  
  6011   Fri Nov 25 22:11:12 2011 MirkoUpdateCDSBeware of fancy filter modules[Rana, Den, Mirko]
It seems you can shoot yourself in
the foot if your filter modules are too complex.
 ChebyTST3.pngCheby.pngCoherenceCheby.pdfChebyAt16kHzBlackand2kHzRed.png 
  6012   Fri Nov 25 23:25:24 2011 MirkoUpdateIOOF2A filter for MC


   
        
            
 F2aForMCcomparedToBS.pdf 
  6013   Sat Nov 26 02:05:43 2011 MirkoUpdateCDSBeware of fancy filter modules 
We replaced the complicated Cheby
filter module with three separate filter
  
  6014   Sat Nov 26 02:15:42 2011 MirkoUpdateSUSNot adaptive, still cool[Rana, Mirko]
I tried out the virtual pendulum
idea today. The idea is to compensate the
 PendulumQ0.1HzWithElip2comma5HzLpWfsOnCorrectedShape.pdfVirtualPendulumFilterShape.pdfSetupVirtualPendulumV2.png 
  6015   Sat Nov 26 07:18:11 2011 SureshUpdateIOOMC WFS related changes to c1ioo modelWhat I did:
    I have changed
the c1ioo model such that the signals which
 WFS_err_20111127.pngcioo_20111127.png 
  6016   Sat Nov 26 07:22:20 2011 sureshUpdateComputers c1sus has been shutdown so that the optics
dont bang around.  This is because the
watch dogs are not working.
  
  6017   Sat Nov 26 10:55:40 2011 ranaUpdateCDSBeware of fancy filter modules 
 Could be that what we're seeing
is the noise floor of the Direct Form II
  
  6018   Sat Nov 26 19:07:40 2011 kiwamuSummaryGreen LockingAM trnasfer function of the Y end laser with doublin crystal

    

       
            
 AMTF_lightwave.pngAMTF_cailbrated.bod.zip 
  6019   Sat Nov 26 19:37:12 2011 DenUpdateGeneralfoton files I've checked foton files for small
numbers. There are several other filters
besides "
  
  6020   Mon Nov 28 06:53:30 2011 kiwamuUpdateCDSc1sus shutdownI have restarted the c1sus machine around
9:00 PM yesterday and then shut it down around
4:00 AM this morning after a little bit of
  
  6021   Mon Nov 28 10:54:40 2011 ranaUpdateSUSF2A filter for MCOur
approach to making the F2A or F2P filters
  
  6022   Mon Nov 28 14:27:35 2011 JenneUpdateRF SystemEOM temp driverHere is 5 days of trend of the EOM temp
sensor and the heater driver monitor. 
Unfortunately, it looks like we're regularly
 EOM_temp_driver_3days.png 
  6023   Mon Nov 28 14:40:43 2011 KojiUpdateRF SystemEOM temp driver

    

       
            
  
  6024   Mon Nov 28 15:00:20 2011 kiwamuUpdateGreen LockingY arm ALS engaged
    

       
            
  
  6025   Mon Nov 28 15:43:36 2011 steveUpdateRF SystemEOM temp zoomed


   
        
            
 eomtempmon.png 
  6026   Mon Nov 28 16:46:55 2011 kiwamuUpdateCDSc1sus is now upI have restarted the c1sus machine and
burt-restored c1sus and c1mcs to the day
before Thank giving, namely 23rd of November.
  
  6027   Mon Nov 28 16:51:57 2011 kiwamuUpdateLSCmodulation frequency resetI reset the modulation frequency to 11065910
Hz (#5530).
It had been at 11065399 Hz probably since
  
  6028   Mon Nov 28 18:19:53 2011 kiwamuUpdateIOOStochmon seems workingHere is a 48 hours trend of the RFAM
monitor (a.k.a StochMon):
 RFAM_48hours.png 
  6029   Mon Nov 28 18:53:35 2011 DenSummaryWienerFilteringseismic noise substractionThere is still a problem why GUR, STS signals
are poorly coherent to MC_L.  But at
least we can see coherence at 2-5 Hz. It
 9x 
  6030   Mon Nov 28 19:24:51 2011 JenneUpdateCDSBeware of fancy filter modules[Rana, Jenne]
Some of the funniness is some kind
of mysterious interaction between 2 filter
 SUSPOS_ETMY_30and0_measured_vs_idealTF.pdfSUSPOS_ETMY_Cheby_measured_vs_idealTF.pdfSUSPOS_ETMY_30and0andCheby_measured_vs_idealTF.pdfSUSPOS_ETMY_30and0andCheby_compareCoherence.pdfSUSPOS_ETMY_30and0andCheby_compareCoherence.pdf 
  6031   Mon Nov 28 22:09:24 2011 ranaUpdateCDSBeware of fancy filter modulesTo see what might be causing the problem,
I used a version of the filter noise test
matlab code that Matt had in the elog.
 noise.pdf 
  6032   Tue Nov 29 02:09:15 2011 ZachUpdateRF SystemEOM temp stabilization fixedI inspected the temperature stabilization
circuit today to see why it wasn't working.
It didn't make sense that it just kept railing
 EOM_temp.png 
  6033   Tue Nov 29 04:47:49 2011 kiwamuUpdateCDSc1sus shut down againI have shut down the c1sus machine at 3:30
AM.
  
  6034   Tue Nov 29 07:45:56 2011 rana, joshSummaryComputer Scripts / Programs40m Daily News web pages As part of the initiative to
get a good daily summary page for aLIGO commissioning,
Josh is spearheading his
  
  6035   Tue Nov 29 14:22:03 2011 ZachUpdateRF SystemEOM temp stabilization performanceI left the EOM stabilization running overnight,
so we can finally see how the EOM temperature
stabilization does over long periods of time.
 Screen_shot_2011-11-29_at_1.33.50_PM.pngScreen_shot_2011-11-29_at_1.34.06_PM.pngScreen_shot_2011-11-29_at_1.41.03_PM.png 
  6036   Tue Nov 29 15:25:29 2011 steveUpdateRF SystemEOM temp stabilization performance It is not obvious what is working.
 
 2days.png 
  6037   Tue Nov 29 15:30:01 2011 jamieUpdateCDSlocation of currently used filter functionSo I tracked down where the currently-used
filter function code is defined (the following
is all relative to /opt/rtcds/caltech/c1/core/release):
  
  6038   Tue Nov 29 15:57:43 2011 DenUpdateCDSlocation of currently used filter function 
We are interested in the following
question : Can the structures defined in
  
  6039   Tue Nov 29 17:10:39 2011 DenUpdatedigital noiseSOS creationOne of the possibilities that we see a
large low-frequency digital noise is due
to Foton. I've checked the SOS coefficients
  
  6040   Tue Nov 29 18:17:27 2011 ZachUpdateRF SystemEOM temp stabilization performance


   
        
            
  
  6041   Tue Nov 29 18:31:40 2011 DenUpdatedigital noiseFoton error In the previous elog we've compared
Matlab and Foton SOS representations using
low-order filter. Now we move on to high
  
  6042   Tue Nov 29 18:54:29 2011 kiwamuUpdateCDSc1sus machine up[Zach / Kiwamu]
 Woke up the c1sus machine in
order to lock PSL to MC so that we can observe
  
  6043   Tue Nov 29 19:08:53 2011 ZachUpdateRF SystemEOM heater disconnectedI disconnected the heater at ~2:20
UTC, leaving the sensor circuit
operational. Don't be fooled by the apparent
 Screen_shot_2011-11-29_at_7.03.36_PM.png 
ELOG V3.1.3-