40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 117 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  14966   Mon Oct 14 16:19:30 2019 KojiUpdateCDSCM servo board testingFor the CM board modeling purpose, the
transfer function from TESTA2 to TESTB2 was
needed. (Attachment 1)
 testb2.pdf 
  14967   Mon Oct 14 16:25:03 2019 KojiUpdateCDSCM servo board testingThe output stage (and AO GAIN stage) of
the MC board was modelled. The transfer function
was measured with the injection from EXC
 servo_out.pdf 
  14968   Mon Oct 14 16:34:42 2019 KojiUpdateCDSCM servo board testingInput referred offsets on the IN1/IN2 were
tested with different gain settings. The
two inputs were plugged by the 50 ohm terminators.
 in12_output_offset.pdfin12_input_offset.pdfin12_input_offset2.pdf 
  14970   Mon Oct 14 17:32:28 2019 KojiUpdateCDSPortal Elog entry for the recent CM servo board testsUpdated Circuit Diagram and photos:
https://dcc.ligo.org/D1500308-v2

- (1) and (6) of the diagram:
 CM_Servo_Diagram.png 
  14971   Tue Oct 15 17:19:38 2019 KojiUpdateGeneralWednesday cleaning work[Liz, Gautam, Chub, Jordan, Koji]

We removed a significant
amount of e-waste from the lab.
 P_20191015_161711.jpeg 
  14978   Fri Oct 18 18:13:55 2019 KojiUpdatesafetyLaser interlock looks OKI've checked the state of the laser
interlock switch and everything looked normal.
  
  15003   Wed Oct 30 23:12:27 2019 KojiUpdateSUSPRM suspension issuesSigh... hard loch   
  Draft   Wed Nov 6 20:34:08 2019 KojiUpdateIOOEOM resonant box installed 




  
  15019   Wed Nov 6 20:34:28 2019 KojiUpdateIOOPower combiner loss (EOM resonant box installed)Gautam and I were talking about some modulation
and demodulation and wondered what is the
power combining situation for the triple
 power_combiner.pdf 
  15043   Thu Nov 21 13:14:33 2019 KojiUpdateLSCCM board studyOne of the differences between the direct
POY and the CM_SLOW POY is the presence of
the CM Servo gain stages. So this might mean
  
  15063   Tue Dec 3 00:10:15 2019 KojiUpdateALSEY uPDH post mixer LPFI got confused. Why don't we see that
too-high-Q pole in the OLTF? 
  
  15196   Fri Feb 7 02:41:28 2020 KojiUpdateGeneraloffice area temperatureNot sure what's wrong, but the workstation
desk is freezing cold again and the room
temp is 18degC (64degF).
  
  15200   Fri Feb 7 19:39:10 2020 KojiUpdateLSCMore high BW POY experimentsThis measurement tells you how the gain
balance between the SLOW_CM and AO paths
should be. Basically, what you need is to
  
  15219   Fri Feb 21 13:02:53 2020 KojiUpdateALSPDH error signals?Check out this elog:
ELOG
4354
  
  15252   Wed Mar 4 21:02:49 2020 KojiUpdateElectronicsMore cabling removedWe are going to replace the old Sun c1ioo
with a modernized supermicro. At the opportunity,
remove the DAC and BIO cards to use them
  
  15267   Wed Mar 11 21:03:57 2020 KojiUpdateBHDSOS packages from SyracuseI opened the packages send from Syracuse.

- The components are not vacuum
clean. We need C&B.
 P_20200311_203449_vHDR_On.jpg 
  15280   Wed Mar 18 22:10:41 2020 KojiUpdateVACMain vol pressure jumpI was in the lab at the time. But did not
notice anything (like turbo sound etc). I
was around ETMX/Y (1X9, 1Y4) rack and SUS
  
  15293   Thu Apr 2 22:19:18 2020 KojiUpdateCDSC1AUXEY wiring + channel listWe want to migrate the end shutter controls
from c1aux to the end acromags. Could you
include them to the list if not yet?
  
  15301   Mon Apr 13 15:28:07 2020 KojiUpdateGeneralPower Event and recovery[Larry (on site), Koji
& Gautam (remote)]

Network recovery
  
  15303   Tue Apr 14 23:50:06 2020 KojiUpdateGeneral40m power glitch recovery[Koji / Gautam (Remote)]

Lab
status
  
  15317   Sat May 2 02:35:18 2020 KojiUpdateALSASY M2 PZT damagedYes, we are supposed to have a few spare
PI PZTs.
  
  15327   Tue May 12 20:16:31 2020 KojiUpdateLSCRelative importance of losses in the arm and PRCIs \eta_A the roundtrip loss for an arm?

Thinking about the PRG=10 you saw:
- What's the current PR2/3 AR?
  
  15340   Wed May 20 19:34:58 2020 KojiUpdateGeneralITM spares and New PR3 mirrors transported to Downs for phasemap measurementTwo ITM spares (ITMU01/ITMU02) and five
new PR3 mirrors (E1800089 Rev 7-1~Rev7-5)
were transported to Downs for phasemap measurement
 container.jpg 
  15358   Wed May 27 17:41:57 2020 KojiUpdateLSCPower buildup diagnosticsThis is very interesting. Do you have the
ASDC vs PRG (~ TRXor TRY) plot? That gives
you insight on what is the cause of the low
  
  15359   Wed May 27 19:36:33 2020 KojiUpdateLSCArm transmission RINMy speculation for the worse RIN is:

- Unoptimized alignment -> Larger
linear coupling of the RIN with the misalignment
  
  15360   Wed May 27 20:14:51 2020 KojiUpdateLSCLock acquisition sequenceI see. At the 40m, we have the direct transition
from ALS to RF. But it's hard to compare
them as the storage time is very different.
  
  15369   Wed Jun 3 03:29:26 2020 KojiUpdateLSCLock acquisition update portalWoo
hoo!

Which 1f signals are
you going to use? PRCL has sign flipping
  
  15374   Thu Jun 4 00:21:28 2020 KojiSummaryCOCITM spares and New PR3 mirrors transported to Downs for phasemap measurementGariLynn worked on the measurement of E1800089
mirrros.
  
  15377   Thu Jun 4 21:32:00 2020 KojiUpdateSUSMC1 Slow Bias issuesWe can limit the EPICS values giving some
parameters to the channels. cf https://epics.anl.gov/tech-talk/2012/msg00147.php

But this does not solve the MC1
  
  15381   Mon Jun 8 12:49:07 2020 KojiUpdateBHDAstigmatism and scattering plotsCan you describe the mode matching 
in terms of the total MM? Is MM_total = sqrt(MM_vert
* MM_horiz)?
  
  15394   Fri Jun 12 01:23:32 2020 KojiUpdateVACPumpspool UPS needs battery replacement1. I agree that it's likely that it
was the temp signal glitch.
Recom #2: I approve to reopen the
  
  15396   Fri Jun 12 17:32:40 2020 KojiUpdateVACPumpspool UPS needs battery replacementJon and Koji remotely supported Jordan's
resetting the TP2 controller.

Here
 Screen_Shot_2020-06-12_at_17.22.23.png 
  15398   Fri Jun 12 19:23:56 2020 KojiUpdateVACPumpspool UPS needs battery replacementThe vacuum safety policy and design are
not clear to me, and I don't know what
the first and second defense is. Since we
  
  15401   Tue Jun 16 13:05:36 2020 KojiUpdateCOCITM spares and New PR3 mirrors transported to Downs for phasemap measurementITMU01 / ITMU02 as well as the five E1800089
mirrors came back to the 40m. Instead, the
two ETM spares (ETMU06 / ETMU08) were delivered
 40m_Optics.jpg 
  15440   Mon Jun 29 20:30:53 2020 KojiUpdateSUSMC1 sat-box de-liddedSigh. Do we have a spare sat box?   
  15470   Sat Jul 11 18:24:30 2020 KojiUpdateLSCMC2 coils need DC balancing?> Can't
we offload this DC signal to the laser crystal
  
  15477   Tue Jul 14 01:55:03 2020 KojiUpdateLSCLocking with POX for CARMThe usual technique is that keeping the
IFO locked with the old set of the signals
and the relative gain/TF between the conventional
  
  15486   Wed Jul 15 19:51:51 2020 KojiUpdateGeneralEmergency light on in control roomIt happened before too. Doesn't it
say it has occasional self-testing or something?
  
  15518   Wed Aug 12 20:14:06 2020 KojiUpdateCDSTiming distribution slot availabilityI believe we will use two new chassis at
most. We'll replace c1ioo from Sun to
Supermicro, but we recycle the existing timing
  
  15519   Wed Aug 12 20:15:42 2020 KojiUpdateElectronicsNumber of the beastGrrr. Let's repair the unit. Let's
get a help from Chub & Jordan.

Do you have a second unit in the
  
  15520   Wed Aug 12 20:16:52 2020 KojiUpdateElectronicsPhotodiode inventoryWhen I tested Q3000 for aLIGO, the failure
rate was pretty high. Let's get 10pcs.
  
  15522   Thu Aug 13 13:35:13 2020 KojiUpdateCDSTiming distribution slot availabilityThe new dolphin eventually helps us. But
the installation is an invasive change to
the existing system and should be done at
  
  15551   Tue Sep 1 01:49:49 2020 KojiUpdateElectronicsTeledyne AP1053 etc were transportedTeledyne AP1053 etc were transported from
Rich's office to the 40m. The box is
placed on the shelf at the entrance.
 20200831203756_IMG_9931.jpg20200831203826_IMG_9932.jpg20200831205126_IMG_9934.jpg 
  15559   Sat Sep 5 14:28:03 2020 KojiUpdateGeneralLO beam: Fiber coupling work2PM: Arrived at the 40m. Started the work
for the coupling of the RF modulated LO beam
into a fiber. -> I left the lab
 20200905212254_IMG_9938.JPG 
  15563   Tue Sep 8 01:31:43 2020 KojiUpdateBHDA first look at RF44 scheme- Loose fiber coupler: Sorry about that.
I could not detect something was loose there,
although some of the locks were not tightened.
  
  15568   Thu Sep 10 15:56:08 2020 KojiUpdateGeneralHEPA & Particle Level Status15:30
- PSL HEPA was running
at 33% and 
  
  15580   Sat Sep 19 01:49:52 2020 KojiUpdateGeneralM4.5 EQ in LAM4.5 EQ in LA 2020-09-19 06:38:46 (UTC)
/ -1d 23:38:46 (PDT) https://earthquake.usgs.gov/earthquakes/eventpage/ci38695658/executive

I only checked the watchdogs. All
  
  15582   Sat Sep 19 18:07:35 2020 KojiUpdateVACTP3 RP failureI came to the campus and Gautam notified
that he just had received the alert from
the vac watchdog.
 vac.pngScreen_Shot_2020-09-19_at_17.52.40.png 
  15584   Sat Sep 19 18:46:48 2020 KojiUpdateGeneralHand soapI supplied a bottle of hand soap. Don't
put water in the bottle to dilute it as it
makes the soap vulnarable for cotamination.
  
  15585   Sat Sep 19 19:14:59 2020 KojiUpdateGeneralITMX released / ETMY UR magnet knocked offThere were two SUSs which didn't look
normal.

- ITMX was easily released by the
 IMG_6218.jpeg 
ELOG V3.1.3-