  11773   Tue Nov 17 15:49:23 2015 KojiConfigurationIOOMC Autolocker modified/opt/rtcds/caltech/c1/scripts/MC/AutoLockMC.csh 
was modified last night.

1. Autolocker sometimes forget
  
  11775   Tue Nov 17 16:21:10 2015 KojiSummaryPSLPMC servo circuit review, follow up measurementsI'm still analyzing the open loop TF
data. Here I report some nominal settings
of the PMC servo
  
  11780   Wed Nov 18 16:51:58 2015 KojiSummaryPSLPMC servo calibrationSummary

The PMC servo error (MIX OUT MON
on the panel) and actuation (HV OUT MON)
 PMC_err_cal.pdf 
  11781   Wed Nov 18 16:53:17 2015 KojiSummaryPSLPMC PZT capacitanceThe PMC PZT capacitance was measured.
- Turn off the HV supplies. Disconnect
HV OUT cable.
  
  11782   Wed Nov 18 17:09:22 2015 KojiSummaryPSLPMC Servo analysisSummary

The PMC servo was analysed. OLTF
was measured and modeled by ZPK (Attachment
 PMC_OLTF.pdfPMC_DSP.pdf 
  11791   Thu Nov 19 17:06:57 2015 KojiConfigurationCDSDisabled auto-launching RT processes upon FE bootingWe want to startup the RT processes one
by one on boot of FE machines.

Therefore /diskless/root/etc/rc.local
  
  11793   Fri Nov 20 15:44:12 2015 KojiSummaryPSLAdded 17.5kHz LPF to the PMC servoAs a final tune of the PMC servo, I've
added 1nF cap at the error signal amplification
stage. The diagram has been updated and uploaded
 PMC_OLTF.pdfPMC_noise_comparison.pdf 
  11794   Sat Nov 21 00:45:30 2015 KojiUpdateIOOIMC fixBased on the observation of the PMC error
signal, I started measuring the IMC OLTF.
Immediately, it
 PDRFsignal_cable.JPGQsignal_cable1.JPGQsignal_cable2.JPGQsignal_cable3.JPG 
  11795   Sat Nov 21 00:46:33 2015 KojiUpdateIOOIMC OLTFHere is the comparison before and after
the fix.

Before the work, the UGF was ~40kHz.
 IMC_OLTF.pdfPMC_noise_comparison.pdf 
  11797   Sun Nov 22 12:07:09 2015 KojiUpdateIOOIMC fixTO DO

Done (Nov 23, 2015) -
Check if the attenuator is still there in
  
  11798   Sun Nov 22 12:12:17 2015 KojiUpdateIOOIMC OLTFWell. I thought a bit more and now I think
it is likely that this is just the servo
bump as you can see in the closed-loop TF.
  
  11800   Mon Nov 23 20:32:43 2015 KojiUpdateLSCFrequency source fixed, IMC LO level adjustedThe frequency source was fixed. The IMC
LO level was adjusted.

IMC is locked => OLTF measured
  
  11801   Mon Nov 23 21:48:49 2015 KojiUpdateLSCFrequency source fixed, IMC LO level adjustedThe trouble we had: the 29.5 MHz
source had an output of 6 dBm instead
of 13 dBm.
 IMG_2136.JPGIMG_2129.JPGIMG_2133.JPG 
  11802   Mon Nov 23 22:12:10 2015 KojiUpdateIOOLO level check for the IMC demod boardIn order to check the proper LO level,
the IMC demod board was checked. As
a short summary, -8dBm is the proper input
 IMG_2137.JPGIMG_2138.JPG 
  11804   Tue Nov 24 01:14:23 2015 KojiUpdateLSCALSY recoveredSorry, I completely forgot to turn the
Marconi on...
  
  11808   Wed Nov 25 10:07:10 2015 KojiUpdateIOOLO level check for the IMC demod boardI didn't finish making the DCC entry
for this module yet.

But the attenuators are
  
  11811   Wed Nov 25 16:46:10 2015 KojiUpdateIOOLO level check for the IMC demod boardAwwww. I found that the demod board has
the power splitter (PSCJ-2-1) with one output
unterminated.
 D990511-40m_151123.pdf 
  11817   Thu Nov 26 19:39:27 2015 KojiUpdateLSCCurrent state of the frequency source, and possible improvementUploaded on T1000461
too.
 RF_Frequency_Source.pdf 
  11822   Sun Nov 29 12:32:26 2015 KojiUpdateLSCCurrent state of the frequency source, and possible improvementI'm not claiming we need to modify
the frequency source immediately as we are
not limited by the oscillator amplitude or
  
  11826   Mon Nov 30 15:17:57 2015 KojiUpdateLSCLO level check for the LSC RF distribution boxT1000461
tells us that the nominal LO input is 2dBm
although we don't know what's the
  
  11829   Mon Nov 30 18:27:30 2015 KojiUpdateLSCstrange behavior of ASDCIt wasn't fully mentioned in ELOG
11814.
We checked the PD first and this behavior
  
  11834   Tue Dec 1 17:26:14 2015 KojiUpdateGeneralMegatron maitenenceSLOWDC servo was dead. I followed EricQ's
instruction.
  
  11835   Tue Dec 1 20:20:16 2015 KojiUpdateGeneralMegatron maitenenceMC Autolocker got stack somewhere. I had
to go to megatron and kill MC Autolocker.

init relaunched the autolocker
  
  11852   Sat Dec 5 21:28:33 2015 KojiHowToCamerasWhen image capture does not work...Do we need "make" everytime?
Do you mean just running "modprobe"
didn't work?
  
  11867   Wed Dec 9 18:45:58 2015 KojiSummaryGeneralNetwork Topology Check[Eric Q, Gautam, Koji]

We went through the network connections
to produce the mapping of the instruments.
 Network_topology_9Dec2015.xlsxNetwork_topology_9Dec2015.pdf 
  11873   Fri Dec 11 13:28:36 2015 KojiUpdateLSCPower recycling gain estimation from arm loss measurementCan I ask you to make a plot of the power
recycling gain as a function of the average
arm loss, indicating the current loss value?
  
  11876   Fri Dec 11 23:12:09 2015 KojiSummaryCOCLoss map measurement documentYutaro left detailed slides for his loss
map measurement

https://dcc.ligo.org/LIGO-G1501547
  
  11920   Thu Jan 7 19:04:25 2016 KojiUpdateLSCAUX X Freq Noise measuredThe next step is to compare this data with
the same measurement with the PSL and the
AUX laser on the PSL table (or the end Y
  
  11923   Fri Jan 8 22:37:17 2016 KojiUpdateGeneralNew WiFi routerI configured a new wifi bridge for a GPIB
Instruments.

The some facts are described on
  
  11941   Thu Jan 21 00:02:11 2016 KojiUpdateLSCHopeful signsThat's a good news. Only quantitative
analysis will tell us if it is true or not.

Also we still want to analyze the
  
  11964   Sat Jan 30 09:56:24 2016 KojiUpdateGreen LockingInnolight laser is 10 years oldIt is strange that there is no difference
between with and without NE, isn't it?
  
  11968   Mon Feb 1 15:43:18 2016 KojiUpdateGreen LockingInnolight laser is 10 years oldThis is the same one as what you got from
Steve. But you can find full pages.

https://wiki-40m.ligo.caltech.edu/PSL/NPRO
  
  11971   Tue Feb 2 18:54:02 2016 KojiUpdateGreen LockingLightwave NPRO moved from PSL table to SP tablejiIn fact, it is one of the most difficult
type mode profiling to measure a beam directly
out from a laser source.
  
  11974   Thu Feb 4 09:16:46 2016 KojiUpdateGreen LockingLightwave NPRO moved from PSL table to SP tableI don't think the discrepancy is a
serious issue as long as the mode is clean.
The mode is determined by the NPRO crystal
  
  11989   Fri Feb 12 19:07:52 2016 KojiUpdateGreen LockingLaser swap - green light recovered but no flashes in the arm800e-6 / 0.225^2 = 0.016

=> 1.6%/W

I thought Kiwamu had roughtly 2%/W.
  
  11991   Mon Feb 15 13:09:33 2016 KojiUpdateGeneralSomething has gone wrong - was there a power outage?Looks like that's the case. LIGO GC
also sent an e-mail that there was a popwer
glitch.
  
  12000   Fri Feb 19 15:12:38 2016 KojiSummaryPEMGuralp Health CheckI measured the guralp raw outputs
and the TFs using the handheld unit and an
FFT analyzer.
 Guralp_Raw_PSD.pdflow_vel_comparison.pdfGuralp_TF.pdf 
  12037   Wed Mar 16 16:02:40 2016 KojiUpdateSUSwire standoff test cutIt looks almost OK, but we need a bit sharper
picture for both the groove and thw wire.
 ruby.png 
  12042   Tue Mar 22 21:30:15 2016 KojiUpdateIOOPMCIMC aligned, WFS offset adjustedThe alignment of the PMC adjusted on the
PSL table: Trans 0.737->0.749

The alignment of the IMC adjusrted
 08.png 
  12049   Sat Mar 26 18:28:24 2016 KojiUpdateelogelogd flakinessElogd have been restarted several times
today because it died everytime I submit
something.
  
  12052   Mon Mar 28 22:16:44 2016 KojiUpdateGeneralNew WiFi routerI configured three more mini wifi extender.
They are ready to use.

We should add these to the host
  
  12072   Tue Apr 12 22:41:00 2016 KojiUpdateIOOPMC/IMC aligned, WFS offset adjustedDid it again.

PMC Trans ~0.739
IMC Trans ~15000
  
  12146   Thu Jun 2 16:35:44 2016 KojiUpdateSUS wire standoffs updateGap of the prism from the mirror

Sag: s = R(1-Cos[ArcSin[d/2/R]])

- Mirror curvature sag for 2mm
 sapphire_stand_off_v3.pdfarrangement-v3.pdf 
  12223   Tue Jun 28 20:43:23 2016 KojiSummaryCOCFirst Contact cleaning practiceMade a dry run of the in-situ cleaning
for a 3inch optic.

Attachment 1: The Al dummy mass
 7x 
  12255   Wed Jul 6 19:36:45 2016 KojiUpdateGeneralSUS VmonI wanted to know what this Vmon exactly
is. D010001
is telling us that the
 HPF.png160706_ITMX_VMON2.pdf160706_ITMX_VMON1.pdf 
  12256   Wed Jul 6 20:51:00 2016 KojiUpdateGeneralSeismometer Enclosure Development | SURF 2016Circuit1: It is nice to
receive the voltage across the transimpedance
resistor with a high impedance buffer (or
  
  12257   Wed Jul 6 21:05:36 2016 KojiUpdateComputer Scripts / ProgramsNew Tabs and Working Summary PagesI started to receive emails from cron every
15min. Is the email related to this? And
is it normal? I never received these cron
 cron_mail.txt.zip 
  12260   Wed Jul 6 21:50:21 2016 KojiUpdateComputer Scripts / ProgramsNew Tabs and Working Summary PagesIt seemed something has been done. And
I got cron emails.
Then, it seemed something has been
  
  12267   Thu Jul 7 14:45:26 2016 KojiUpdateGeneralpianosa monitor deadJohannes, Koji

We obtained two monitors of the
same type from Larry.
  
  12269   Thu Jul 7 16:05:55 2016 KojiUpdateGeneralSUS VmonAh, thanks. That makes sense. In that case,
we should remove the texts "30Hz HPF"
from the suspension screens.
  