Fri Mar 20 12:07:19 2009 |
Yoichi | Configuration | ASC | ETMY beam centering | I forgot to put this in the elog.
Last Sunday night, I centered the beam on
the ETMY because it was too low.
|
|
1418
|
Mon Mar 23 15:50:44 2009 |
rana | Configuration | LSC | filters deleted, lsc rebooted | The LSC time had gone too high. I deleted
~20 filters and rebooted. CPU time came down
to 50 usec. |
|
1421
|
Tue Mar 24 13:10:07 2009 |
Alberto | Configuration | PSL | new mirror installed on the AP table | New flipping mirror installed on the AP
table on the beam path to the REFL199 PD.
If you're missing the double demod |
|
1442
|
Mon Mar 30 12:29:17 2009 |
Yoichi | Configuration | | MC1 glitches not seen during the weekend | The attached is the MC trend for the past
12 hours.
There is no MC1 glitches in the OSEM signals. |
|
1443
|
Mon Mar 30 12:46:36 2009 |
Yoichi | Configuration | IOO | IOO QPDs were missing the beam | When I re-locked the MC, I wanted to check
the trend of the IOO QPDs to see if the input
beam pointing has changed.
|
|
1446
|
Mon Mar 30 17:02:46 2009 |
Yoichi | Configuration | General | AP OSA aligned | I aligned the AP OSA, which had been mis-aligned
for a while. |
|
1457
|
Tue Apr 7 21:39:57 2009 |
Yoichi | Configuration | Computers | LSC code recompiled with a fix for denormalization problem | This is not my work but I will put it for
the record.
|
|
1459
|
Wed Apr 8 09:36:20 2009 |
steve | Configuration | VAC | valve condition changed to BG to calibrate the RGA | Vacuum
normal valve condition was changed to accommodate
SRS-RGA calibration. |
|
1460
|
Wed Apr 8 18:18:33 2009 |
rana | Configuration | Computers | LSC code recompiled with a fix for denormalization problem | Below is the link to the anti-denormalization
technique that Rolf and Alex implemented
at the sites,
|
|
1461
|
Wed Apr 8 18:46:50 2009 |
rana | Configuration | General | DMF, SVN, x2mc, and matlab | While waiting for the installation of the
32-bit Matlab 2009a to finish, I tried updating
our seisBLRMS.m code. |
|
1474
|
Sun Apr 12 01:19:30 2009 |
Yoichi | Configuration | Computers | New FE codes for suspensions not successful | Alex recompiled the suspension FE codes for
c1susvme1 and c1susvme2 to fix the denormalization
problem.
|
|
1483
|
Wed Apr 15 02:18:42 2009 |
rana | Configuration | Computers | nodus vfstab changed for rigel | nodus was hanging because it was trying
to mount the |
|
1486
|
Wed Apr 15 11:25:21 2009 |
steve | Configuration | VAC | RGA cal completed |
|
|
1492
|
Thu Apr 16 17:48:00 2009 |
Yoichi | Configuration | Computer Scripts / Programs | AutoDTT | As Peter mentioned in his entry on the last
night's locking, I imported AutoDTT from
Hanford.
|
|
1494
|
Fri Apr 17 11:37:32 2009 |
Yoichi | Configuration | Computer Scripts / Programs | AutoDTT | In order to get test point data with AutoDTT,
you have to pre-trigger test points you want
to use.
|
|
1498
|
Mon Apr 20 05:18:42 2009 |
Yoichi | Configuration | Locking | FM6 and FM10 of LSC-MC were restored | During tonight's locking work, I realized
that FM6 and FM10 (both resonant gains around
20Hz) were actually activated by cm_step.
|
|
1502
|
Mon Apr 20 19:51:51 2009 |
Jenne | Configuration | PSL | PMC has new Level 13 Mixer installed | The new Level 13 mixer on the PMC servo
board is installed (minicircuits SRA-3MH).
Since the RF output of the LO board was ~16dBm, |
|
1503
|
Mon Apr 20 20:00:44 2009 |
rana | Configuration | IOO | McWFS gains re-allocated | Since it looks like the night time people
have been running with a WFS gain of 0.05
and I like the slider
|
|
1504
|
Mon Apr 20 20:45:25 2009 |
rana | Configuration | General | SVN: project area added | I added the [B]/cvs/cds/project/[/B] directory
to the SVN. I've noticed that we've been
using target/ for code which is not
|
|
1507
|
Wed Apr 22 11:16:26 2009 |
steve | Configuration | VAC | Cryo pump is ON and the Maglev is dead | The
CRYO pump cooled down and VC1 was opened.
This |
|
1520
|
Sat Apr 25 00:45:31 2009 |
Yoichi | Configuration | VAC | Reflector for the cryopump temperature monitor changed | The temperature of the cryopump head is monitored
by a photo switch looking at an aluminum
foil reflector attached to the needle of |
|
1521
|
Sat Apr 25 02:54:25 2009 |
Yoichi | Configuration | VAC | Reflector for the cryopump temperature monitor changed | [quote]The temperature of the cryopump head
is monitored by a photo switch looking at
an aluminum foil reflector attached to the |
|
1524
|
Mon Apr 27 18:31:44 2009 |
steve | Configuration | VAC | VC1 closed | CC1 5e-7 Torr, VC1 closed at 18:25,
IFO is not pumped, RGA is in bg-mode
|
|
1525
|
Tue Apr 28 01:48:45 2009 |
pete | Configuration | VAC | VC1 open | At about 1am or so Yoichi and I opened
VC1. CC1 had fallen to about 5e-5 torr. |
|
1527
|
Tue Apr 28 09:27:32 2009 |
steve | Configuration | VAC | cryopump deserves some credit | Congratulation Yoichi and Peter for full
rf locking at night. Let's remember that
the cryopump was shaking the hole vac envelope |
 |
1551
|
Wed May 6 16:56:35 2009 |
rana, alex, joe | Configuration | Computers | daqd log, cront, etc. | While Alex came over, we investigated the
log file problems with DAQD and NDS on FB0.
There was a lot of
|
|
1554
|
Thu May 7 12:21:36 2009 |
josephb, alex | Configuration | Computers | fb40m | Having determined that Rana (the computer)
was having to many issues with testing the
new Raid array due to age of the system, |
|
1555
|
Thu May 7 15:22:19 2009 |
josephb, alberto | Configuration | Computers | fb40m |
|
|
1556
|
Thu May 7 17:59:23 2009 |
Alberto | Configuration | | MC WFS | This afternoon the MC could not get locked.
I
first checked the Osems values at the MC
mirrors and compared them to the trend of |
|
1601
|
Mon May 18 19:44:52 2009 |
rana, steve | Configuration | VAC | Cryo Pump turned off and valved off: 1 beer can only | I was seeing some excess noise in the ETMY
oplev yaw and so we turned off the cryo and
restarted c1vac2 to get the turbo pump channels |
|
1602
|
Mon May 18 20:16:20 2009 |
rana | Configuration | VAC | not it | There was essentially no change in the ETMY
oplev spectrum with the cryo off!
|
|
1603
|
Mon May 18 21:34:18 2009 |
rana | Configuration | SUS | ETMY f2pRatio script run | Now that the ETMY optical lever is not so
bad, I ran the f2pRatio script and it seems
to have worked.
|
|
1604
|
Tue May 19 09:34:29 2009 |
steve | Configuration | VAC | IFO is not pumped & CRYO is being regenerated | Morning Vacuum condition: IFO is not being
pumped, P1 pressure is 1.8 mTorr and rising
(see P1 pressure plot of 100 min ).
|
 |
1605
|
Tue May 19 12:30:41 2009 |
rob | Configuration | SUS | ETMY f2pRatio script run | [quote]Now that the ETMY optical lever is
not so bad, I ran the f2pRatio script and
it seems to have worked.
|
|
1609
|
Tue May 19 16:18:45 2009 |
steve | Configuration | VAC | IFO pressure is 4.2e-7 Torr with CRYO pump | [quote]Morning Vacuum condition: IFO is not
being pumped, P1 pressure is 1.8 mTorr and
rising (see P1 pressure plot of 100 min ).
|
|
1615
|
Thu May 21 12:58:32 2009 |
rob | Configuration | ALARM | PEM count-half disabled | I've disabled the alarm for PEM_count_half,
using the mask in the 40m.alhConfig file.
We can't do anything about it, and it's just |
|
1619
|
Fri May 22 00:43:24 2009 |
rob | Configuration | Computer Scripts / Programs | IFO configure scripts for XARM and YARM | I edited the configure scripts (those called
from the C1IFO_CONFIGURE screen) for restore
XARM and YARM. These used to misalign |
|
1632
|
Sat May 30 11:24:56 2009 |
rob | Configuration | PSL | NPRO slow scan | I'm setting SLOWDC to about -5.
I had to edit FSSSlowServo because
it had hard limits on SLOWDC at (-5 and 5). |
|
1637
|
Mon Jun 1 14:33:42 2009 |
rob | Configuration | Computer Scripts / Programs | op540m Monitor added to web status | I added op540m's display 0 (the northern-most
monitor in the control room) to the MEDM
screens webpage: https://nodus.ligo.caltech.edu:30889/medm/screenshot.html |
|
1642
|
Tue Jun 2 23:12:08 2009 |
rob | Configuration | Computers | ntp on op440m | I restarted ntpd on op440m to solve a "synchronization
error" that we were having in DTT.
I also edited the config file (/etc/inet/ntp.conf) |
|
1650
|
Thu Jun 4 01:32:20 2009 |
rob | Configuration | LSC | AS port mode scan | Here is a set of mode scans of the AS port,
using the OMC as a mode scanner. The
plot overlays various configurations of the |
|
1671
|
Fri Jun 12 09:56:38 2009 |
steve | Configuration | VAC | new maglev installed | Joe and Steve
The retrofitted Osaka 390 was installed |
|
1672
|
Fri Jun 12 15:34:49 2009 |
steve | Configuration | VAC | maglev is running |
|
|
1673
|
Mon Jun 15 15:17:33 2009 |
josephb, Steve | Configuration | VAC | Vacuum control and monitor screens | We updated the vacuum control and monitor
screens (C0VAC_MONITOR.adl and C0VAC_CONTROL.adl).
We also updated the /cvs/cds/caltech/target/c1vac1/Vac.db |
|
1674
|
Mon Jun 15 16:31:36 2009 |
steve | Configuration | VAC | RGA is scanning new Maglev |
|
|
1677
|
Tue Jun 16 09:02:30 2009 |
steve | Configuration | VAC | new maglev RGA scan | The maglev fore line pressure is 3e-6 torr
at CC2 after 4 days of pumping. Varian turbo
V-70 is pumping on it through V4 and VM2 |
 |
1682
|
Wed Jun 17 01:07:50 2009 |
rob | Configuration | Computers | matapps on /cvs/cds | I checked out a copy of matapps into /cvs/cds/caltech/apps/lscsoft
so that I could find the matlab function
strassign.m, which is necessary for some |
|
1686
|
Fri Jun 19 13:38:42 2009 |
Alberto | Configuration | Computers | elog rebooted | Today I found the elog down, so I rebooted
it following the instructions in the wiki. |
|
1688
|
Fri Jun 19 14:30:47 2009 |
Alberto | Configuration | Computers | elog rebooted |
|
|
1689
|
Sun Jun 21 00:08:26 2009 |
rana | Configuration | Computers | elog rebooted |
nodus:log>dmesg
|
|