40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 106 of 171  Not logged in ELOG logo
Entry  Thu Mar 21 10:29:12 2013, Manasa, Update, Computers, Computers down since last night down.pngdown.png
    Reply  Thu Mar 21 12:04:05 2013, Manasa, Update, Computers, Fixed up.png
       Reply  Thu Mar 21 12:33:51 2013, rana, Update, Computers, Fixed 
Entry  Fri Mar 22 01:28:56 2013, Manasa, Update, Lasers, Beam profile of NPRO from ATF 
Entry  Fri Mar 22 19:46:29 2013, Koji, Summary, LSC, Diode impedance test result 
Entry  Thu Mar 21 09:53:46 2013, Annalisa, Update, Locking, Finding the beat note 
    Reply  Thu Mar 21 10:19:28 2013, Koji, Update, Locking, Finding the beat note 
       Reply  Thu Mar 21 13:11:42 2013, Annalisa, Update, Locking, Finding the beat note Beat_note_setup.jpg
          Reply  Thu Mar 21 13:50:08 2013, Jamie, Update, Locking, incident angles 
             Reply  Thu Mar 21 14:02:45 2013, Annalisa, Update, Locking, incident angles 
                Reply  Fri Mar 22 23:23:38 2013, Annalisa, Update, Locking, Beat note still missing Beat_note_-_new_setup.jpg
Entry  Mon Mar 25 09:52:22 2013, Jenne, Update, Computers, c1lsc mxstream won't restart 
    Reply  Mon Mar 25 11:42:45 2013, Jamie, Update, Computers, c1lsc mx_stream ok 
Entry  Wed Mar 13 03:12:47 2013, Manasa, Jenne, Update, Locking, TWO arms TWO colors 
    Reply  Wed Mar 13 08:34:33 2013, yuta, Update, Locking, TWO arms TWO colors 
       Reply  Wed Mar 13 16:29:25 2013, Manasa, Update, Locking, TWO arms TWO colors 
    Reply  Wed Mar 13 10:26:58 2013, Manasa, Update, Locking, We're still good!! 
    Reply  Mon Mar 25 15:01:33 2013, Manasa, Update, Locking, TT1 drift 
       Reply  Mon Mar 25 15:24:41 2013, rana, Update, Locking, TT1 drift 
Entry  Mon Mar 25 16:51:43 2013, Chloe, Update, , Final QPD Circuit Design IMG-20130325-00244.jpg
Entry  Mon Mar 25 18:58:09 2013, Albert Yang, Update, optical tables, Optical Table Toolboxes 
Entry  Mon Mar 25 23:17:11 2013, rana, Summary, IOO, MC  MC-trans.pdf
Entry  Mon Mar 25 23:27:26 2013, Chloe, Update, , QPD Circuit 
Entry  Tue Mar 26 00:06:37 2013, Jenne, Update, Locking, AS beam put back on PD 
Entry  Tue Mar 26 08:50:02 2013, Steve, Update, General, janitor day 
Entry  Thu Mar 7 12:39:12 2013, Jenne, Update, Locking, Erudite discussion on PRMI locking 
    Reply  Thu Mar 7 16:55:28 2013, Koji, Update, Locking, Erudite discussion on PRMI locking 
    Reply  Tue Mar 26 00:17:47 2013, Jenne, Update, Locking, REFL pickoff fraction 
    Reply  Tue Mar 26 11:08:03 2013, Jenne, Update, Locking, PRMI locking should be possible - let's get it done! PRMI_SBres_plot_allTheFs_LowRes.pngLSC_sigmatrix_PRMI.pdf
Entry  Wed Mar 20 14:44:47 2013, Jamie, Update, Optics, updated calculations of PRC/SRC g-factors and ARM mode matching 
    Reply  Mon Mar 25 16:51:59 2013, Jenne, Update, Optics, updated calculations of PRC/SRC g-factors and ARM mode matching 
    Reply  Tue Mar 26 11:33:55 2013, Jamie, Update, Optics, HOWTO calculate effective RoC of flipped TT mirror.mtransmission.mTTflipped.mM2Reff.m
Entry  Wed Mar 13 16:25:16 2013, Manasa, Update, IOO, Tuning MC length/FSR 
    Reply  Tue Mar 26 01:40:49 2013, Koji, Update, IOO, Tuning MC length/FSR 
    Reply  Tue Mar 26 15:00:55 2013, Manasa, Update, IOO, Tuning MC length/FSR MC_spectrum.pngMC_spectrum.zip
       Reply  Tue Mar 26 15:43:45 2013, rana, Update, IOO, Tuning MC length/FSR 
       Reply  Tue Mar 26 17:27:17 2013, Koji, Update, IOO, Tuning MC length/FSR 
Entry  Tue Mar 26 17:32:30 2013, Chloe, Update, , QPD/ECDL Progress IMG-20130326-00245.jpg
Entry  Tue Mar 26 20:20:10 2013, Charles, Update, ISS, ISS Design Plans - Servo Noise Analysis ISS.pdf
Entry  Thu Mar 28 00:31:11 2013, Jenne, Update, SUS, PRMI optics' oplev servos tuned 8x
Entry  Wed Mar 27 15:46:13 2013, Jenne, Update, Locking, PRMI progress PRMI_sb_27Mar2013.png
    Reply  Thu Mar 28 01:59:33 2013, Jenne, Update, Locking, PRMI progress - even better! 
       Reply  Thu Mar 28 04:21:40 2013, rana, Update, Locking, PRMI progress - even better! 
Entry  Mon Jul 23 13:30:06 2012, Jenne, Update, Green Locking, Yarm ALS laser is funny / dying 
    Reply  Mon Jul 23 18:01:30 2012, Jenne, Update, Green Locking, Yarm ALS laser is funny / dying 
    Reply  Thu Mar 14 16:41:48 2013, Jenne, Update, Green Locking, Yarm ALS laser is funny / dying 
       Reply  Thu Mar 14 17:31:57 2013, Manasa, Update, Green Locking, X arm green locked in TEM00 
          Reply  Fri Mar 15 01:57:02 2013, Jenne, Update, Green Locking, X arm green locked in TEM00 
       Reply  Fri Mar 15 02:19:01 2013, Jenne, Update, Green Locking, Yarm ALS laser is funny / dying 
          Reply  Fri Mar 15 15:26:13 2013, Koji, Update, Green Locking, Yarm ALS laser is funny / dying 
             Reply  Mon Mar 18 14:58:15 2013, Steve, Update, Green Locking, repair or replace dead NPRO 
                Reply  Thu Mar 28 07:58:15 2013, Steve, Update, Green Locking, NPRO repair 
Entry  Thu Mar 28 10:44:30 2013, Manasa, Update, Computers, c1lsc down cds_FE.pngcds_fe1.png
    Reply  Thu Mar 28 12:50:52 2013, Jenne, Update, Computers, c1lsc is fine 
Entry  Mon Mar 25 23:20:57 2013, Annalisa, Summary, Auxiliary locking, Beat note found! 
    Reply  Thu Mar 28 19:32:22 2013, Annalisa, Summary, Auxiliary locking, Beat note found! BeatFreq.jpg
Entry  Wed Mar 27 21:53:21 2013, Annalisa, Update, ABSL, Beat note of ATF auxiliary laser 
    Reply  Thu Mar 28 23:00:30 2013, Annalisa, Update, ABSL, Beat note of ATF auxiliary laser found 
Entry  Tue Mar 12 00:35:56 2013, Jenne, Update, Computers, FB's RAID is beeping  
    Reply  Tue Mar 12 12:06:22 2013, Jamie, Update, Computers, FB recovered, RAID power supply #1 dead 
       Reply  Tue Mar 12 14:51:00 2013, Steve, Update, Computers, buy warranty or not ? 
    Reply  Fri Mar 29 17:24:43 2013, Jamie, Update, Computers, FB RAID power supply replaced 
Entry  Mon Apr 1 09:05:09 2013, Jenne, Gabriele, Configuration, LSC, POP22 configuration 
Entry  Fri Mar 29 19:56:02 2013, Gabriele, Metaphysics, LSC, Lock of PRMI on sidebands lock_prmi5.pdflock_prmi6.pdflock_prmi7.pdfoscillation.pdflock_prmi8.pdf
    Reply  Sun Mar 31 17:26:32 2013, rana, Update, LSC, Lock of PRMI on sidebands 
    Reply  Mon Apr 1 09:25:35 2013, Jenne, Metaphysics, LSC, Lock of PRMI on sidebands 
Entry  Mon Apr 1 16:13:50 2013, Chloe, Update, , QPD 
Entry  Fri Mar 29 19:23:49 2013, Gabriele, Jenne, Frogs, LSC, Analog whitening filter of REFL55 not switching 
    Reply  Fri Mar 29 19:58:24 2013, Gabriele, Jenne, Frogs, LSC, Analog whitening filter of REFL55 not switching 
    Reply  Mon Apr 1 16:24:09 2013, Jamie, Frogs, LSC, PD whitening switching fixed (loose connection at break-out box) 20130401_161858.jpg20130401_161917.jpg
Entry  Mon Apr 1 17:59:04 2013, Jenne, Update, Locking, PRMI videos 
Entry  Tue Apr 2 10:22:37 2013, Rana, Gabriele, Jenne, Update, LSC, PRMI lock lock_prmi_sb.pdf
    Reply  Tue Apr 2 11:08:16 2013, Koji, Update, LSC, PRMI lock 
Entry  Tue Apr 2 20:52:35 2013, rana, Update, Computers, iMac bashed 
Entry  Thu Mar 28 23:06:48 2013, Annalisa, Update, Auxiliary locking, "Alberto" NPRO laser again on PSL table 
    Reply  Mon Apr 1 23:22:17 2013, Annalisa, Update, Auxiliary locking, Beat note between "Alberto" NPRO laser and PSL laser Beat_Note.jpg
       Reply  Tue Apr 2 22:39:17 2013, Annalisa, Update, Auxiliary locking, Beat note between "Alberto" NPRO laser and PSL laser Beat_note_3col.jpg
Entry  Mon Mar 5 20:31:33 2012, Koji, Update, LSC, 22/110MHz path for POP 
    Reply  Tue Mar 6 22:23:04 2012, Koji, Update, LSC, 22/110MHz path for POP 
       Reply  Wed Mar 7 15:56:36 2012, Koji, Update, LSC, 22/110MHz path for POP RFseparator.pngimpedance.pdftransmission.pdf
          Reply  Wed Feb 27 20:50:41 2013, Manasa, Update, LSC, 22/110MHz path for POP POP.png
             Reply  Tue Apr 2 23:14:02 2013, rana, Update, LSC, 22/110MHz path for POP 
Entry  Wed Apr 3 03:18:23 2013, Jenne, Update, Locking, PRMI locked with REFL55 I&Q for more than 1 minute PRMI_sb_80sec_2Apr2013.png
Entry  Wed Apr 3 01:32:04 2013, Jenne, Update, Computers, updated EPICS database (channels selected for saving) 
    Reply  Wed Apr 3 14:45:34 2013, Jamie, Update, Computers, updated EPICS database (channels selected for saving) 
Entry  Wed Apr 3 15:00:24 2013, Jamie, Summary, Electronics, Sorensen supplies in LSC rack (1Y2) 20130403_141842.jpg
Entry  Wed Apr 3 18:22:00 2013, Jenne, Update, Electronics, POP110 re-implemented 
Entry  Wed Apr 3 16:03:59 2013, Chloe, Update, , QPD Voltage Regulators 
    Reply  Wed Apr 3 18:27:03 2013, Koji, Update, , QPD Voltage Regulators 
Entry  Thu Apr 4 10:12:55 2013, Gabriele, Summary, LSC, POP22 and POP110 pop110_2.pdf
Entry  Thu Apr 4 10:32:42 2013, Gabriele, Summary, LSC, REFL55 error signals prmi_refl_signals.pdf
    Reply  Thu Apr 4 10:46:54 2013, Koji, Summary, LSC, REFL55 error signals 
Entry  Thu Apr 4 13:39:12 2013, Max Horton, Update, Summary Pages, Graph Limits 
Entry  Mon Apr 8 22:43:44 2013, rana, Update, PSL, MC locking troubles: MC/FSS servo unstable Untitled.png
Entry  Sun Apr 7 20:49:19 2013, Zach, Update, General, Restarted elog 
    Reply  Tue Apr 9 01:46:40 2013, Zach, Update, General, Restarted elog 
Entry  Tue Apr 9 14:55:13 2013, Jamie, Update, CDS, overbooked test points cause of DAQ problems lsc-gds.png
Entry  Wed Apr 10 01:10:22 2013, Jenne, Update, Locking, Configure screen and scripts updated 
Entry  Tue Apr 9 00:32:39 2013, rana, Configuration, IOO, Turn on MCL 
    Reply  Wed Apr 10 03:59:41 2013, Den, Configuration, IOO, Turn on MCL MCL.pdf
Entry  Mon Apr 8 08:05:41 2013, Steve, Update, PSL, PMC locked 
    Reply  Mon Apr 8 10:19:46 2013, Jenne, Update, PSL, LSC left enabled 
    Reply  Tue Apr 9 07:48:10 2013, Steve, Update, PSL, PMC locked pmc10d.png
       Reply  Wed Apr 10 07:37:33 2013, Steve, Update, PSL, PMC locked pmc4d.png
Entry  Wed Apr 10 15:49:22 2013, Annalisa, Configuration, COMSOL Tips, Yend table eigenfrequency simulation with COMSOL Pics_end_table.pdf
Entry  Thu Apr 11 02:49:18 2013, Den, Update, Locking, PRCL on carrier pop_rin.pdfpower.png
Entry  Thu Apr 11 03:23:12 2013, Den, Update, General, MCL threshold 
ELOG V3.1.3-