40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 106 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  8905   Tue Jul 23 13:29:58 2013 KojiSummaryGeneral record of the initial state  initial_state_130723.png 
  8906   Tue Jul 23 13:55:08 2013 KojiUpdateIOOMC manually alignedThe MC was manually aligned. The spot positions
were measured and it is consistent with the
measurements done yesterday.
 MCalignment.pngMCspot.png 
  8908   Tue Jul 23 16:39:31 2013 KojiUpdateGeneralFull IFO alignment recovered[Annnalisa Koji]
Full alignment of the IFO was recovered.
The arms were locked with the green beams
 alignment.png 
  8913   Tue Jul 23 21:32:43 2013 KojiUpdateIOOFound the cause of mysterious MC motionThesedays
we were continuously annoyed by unELOGGED
activities of the interferometer.
  
  8918   Wed Jul 24 15:07:54 2013 KojiUpdateSUSSR2 flippedAfter the first flipping, X/Y arms were
aligned and locked. Then the ASS aligned
the arms.
  
  8921   Thu Jul 25 02:53:00 2013 KojiUpdateGeneralIFO Alignment after TT flipping - no progressThere was no progress tonight after Jenne
left. 
I could not find any reasonable fringes
  
  8926   Fri Jul 26 13:39:30 2013 KojiUpdateASCPOP QPD analysisIt was not actually easy to see from the
entry what signal was taken in what condition
but from the shape of the spectra
  
  8934   Mon Jul 29 16:15:13 2013 KojiUpdateVACAC removedPrior to the access connector removal,
Manasa and I aligned the IFO mirrors. 
The arms were locked and aligned by
  
  8936   Tue Jul 30 00:21:15 2013 KojiUpdateGeneralVent progress[Koji, Manasa, Sujan] 
Tomorrow we'll make final checks
  
  8938   Tue Jul 30 13:41:35 2013 KojiUpdateGeneralITMX oplevI wonder what optics is causing the halo
on the oplev beam.
It this comes from any uncoated lens
  
  8968   Mon Aug 5 19:10:01 2013 KojiUpdateCDSChoosing LO Amplitudes and Frequencies - I suppose the green transmission paths
were thoroughly inspected and aligned in
prior to the measurement
  
  8975   Wed Aug 7 10:09:30 2013 KojiUpdateLSCArms locked in IR, aligned. IFO at nominal powerI have a concern about the SRM suspension.
The yaw alignment bias produces huge pitch
coupling.
  
  8977   Wed Aug 7 15:32:37 2013 KojiUpdateASCASS setting up accelerated (slightly)I moved bunch of ezcawrite from the ASS
Dither On script to a snapshot file.
This accelerated a half of the "up"
  
  8982   Wed Aug 7 22:18:43 2013 KojiUpdateASCASS updateWhile Gautam is working on the Xarm green
ASS...
The EPICS monitor points for the
 Screenshot-Untitled_Window.png 
  8989   Thu Aug 8 21:25:36 2013 KojiUpdateGeneralPost-vent alignment cont'd- IPANG aligned on the QPD. The beam seems
to be partially clipped in the chamber.
- Oplev of the IFO mirrors are aligned.
  
  8991   Fri Aug 9 21:05:28 2013 KojiUpdateSUSfixed: SRM coils fine - problem with slow bias sliderNow the SRM Yaw bias in yaw is functional
without any strage behavior.
  
  8992   Fri Aug 9 22:51:37 2013 KojiUpdateLSCPRMI(sb) lock recoveredPRMI(sb) lock
was recovered
  
  8999   Mon Aug 12 17:30:03 2013 KojiUpdateASCPRCL ASS software in placeWhy POPDC???   
  9007   Tue Aug 13 17:20:54 2013 KojiUpdateCDS[Fixed] c1iscex needs helpc1x01 timing issue was solved. Now all
of the models on c1iscex are nicely running.
Symptons
  
  9009   Tue Aug 13 21:49:32 2013 KojiSummaryGeneralTesting new AG4395A network analyzerNew AG4395, sn MY41101114  for West
Bridge Labs was delivered. For the test purpose
it is at the 40m now.
 AG4395A_noise.pdf 
  9010   Tue Aug 13 22:21:12 2013 KojiSummaryGeneralMinicircuit Filter TFs (AG4395A test)As a part of the network analyzer test
in the previous entry, the transfer functions
of Mini-Circuits filters we have at the 40m
 Minicircuit_LPF.pdfMinicircuit_BPF.pdfMinicircuit_HPF.pdf130813.zip 
  9012   Thu Aug 15 01:51:50 2013 KojiSummaryGeneralRFM<->Dolphin bridge distributed to c1rfm and c1mcsSince the RFM-Dolphin bridges for the ASX
model was added to the c1rfm model, c1rfm
kept timing-out from the single sample time
  
  9018   Fri Aug 16 13:25:50 2013 KojiUpdateASSASX model/screen cleaning up[Koji Manasa]
Yesterday we cleaned up the ASX model
and screens to have more straight forward
  
  9025   Mon Aug 19 09:36:32 2013 KojiUpdateGreen LockingXend green aligned[Rana Koji]
This is an elog about the activity
on Friday night.
 ALS_OUTOFLOOP_130816.pdf 
  9032   Mon Aug 19 15:23:07 2013 KojiUpdateIOOMC mirrors' ASC has non-zero inputs[Jenne, Koji]
This disturbance in the MC ASC channels
were fixed.
  
  9035   Mon Aug 19 19:08:35 2013 KojiUpdateGreen LockingXend green layout corrections- An Aluminum mirror instead of 2"
unknown mirror for the pick-off for the rejected
beam from the green faraday isolator (Steve)
  
  9040   Tue Aug 20 11:41:30 2013 KojiUpdateLSCREFL investigationsAs I always tell everyone: Don't use a 10% reflector
which produce ghost beams. Use a 90% reflector.
  
  9048   Wed Aug 21 23:50:40 2013 KojiUpdateSUSPRM SUS_LSC violin (FM5) set to correct frequency[Jenne Koji]
It seems that the PRM violin mode
freqs shifted from 625-ish to 640Hz.
  
  9053   Thu Aug 22 13:20:54 2013 KojiUpdateLSCDRMI Locked for 1+ minute!!!!!!Don't go for a hacky solution. We want
to climb a staircase step by step.
Prepare an independent 110MHz demod
  
  9060   Sat Aug 24 00:11:07 2013 KojiUpdateLSCDRMI Locked with improved lock streatchesFriday night  Screenshot-Untitled_Window.png 
  9064   Mon Aug 26 19:13:38 2013 KojiUpdateLSCLSCoffset script updatedWhat do you mean???
What is the effect of the anti-whitening
filter?
  
  9073   Tue Aug 27 18:58:52 2013 KojiConfigurationElectronics110 MHz LO options- Do we have an appropriate amplifier?
- True challenge could be to find
a feedthrough for the new port. (or to find
  
  9076   Tue Aug 27 20:43:34 2013 KojiConfigurationCDSfront end IPC configurationThe reason we had the PCIe/RFM system was
to test this mixed configuration in prior
to the actual implementation at the sites.
  
  9116   Fri Sep 6 23:01:08 2013 KojiUpdateLSCStable DRMI lock was recovered from the impact on the RF system modificationSummary
 DRMI.pngSensMat_PRMI_1000cts_580Hz_2013-08-26_235635.pngSensMat_PRMI_1000cts_580Hz_2013-09-06_201137.png 
  9124   Wed Sep 11 23:43:10 2013 KojiSummaryGreen LockingALS locking in both armsWhat was the beat freq for each arm?
The HF noise level depends on the
frequency of the beat note.
  
  9189   Thu Oct 3 01:18:57 2013 KojiHowToLSCsteps to full IFOI vote on PRMI+1arm -> PRFPMI   
  9251   Thu Oct 17 18:29:28 2013 KojiUpdateLSCPRMI+2arm attempt (not really yet)While Manasa, Jenne, and Masayuki are working
on the preparing the interferometer, I write
the elog for them.
  
  9256   Mon Oct 21 13:15:52 2013 KojiUpdateIOOPMC alignedPMC aligned. Trans 0.78 -> 0.83   
  9280   Thu Oct 24 15:19:58 2013 KojiUpdateLSCPRMI + 2 ALS arms> all of complications
of handing off
  
  9284   Thu Oct 24 21:46:18 2013 KojiUpdateGreen LockingALS OFFSETTER calibration

    

       
            
  
  9327   Fri Nov 1 17:44:06 2013 KojiSummaryLSCSimulation of REFL_3f signal when the arms come inYes, the resonance of the 2nd-order sidebands
to the IFO screws up the 3f scheme.
2f (~22MHz) and 10f (~110MHz) are
  
  9340   Mon Nov 4 18:24:15 2013 KojiUpdateLSCThoughts on Transition to IR You have the data. Why don't you
just calculate 1/SQRT(TRX)?
...yeah, you can calculate it but
  
  9363   Sat Nov 9 10:25:43 2013 KojiUpdateLSCNew Broadband PD for POP 22/110General Remarks on the BBPD

- To form the LC network: Use fixed
  
  9390   Fri Nov 15 09:27:58 2013 KojiUpdateIOOWFS with beam dumpsUnfortunately this does not work. These
WFSs are not the detectors which we can move
freely.
  
  9394   Fri Nov 15 12:00:28 2013 KojiUpdateCDSCan't talk to AUXEY?

    

       
            
  
  9403   Mon Nov 18 21:26:13 2013 KojiUpdateSUSPRM picturesCan't we somehow hook up this camera to
the MUX with the movie mode? 
I think both the MUX and the sensoray
  
  9404   Mon Nov 18 21:40:24 2013 KojiUpdateLSCPRM oplev measured and modeled TFI forgot how we could turn on the PRM oplev
servo and the PRM ASC servo at the same time
without conflict.
  
  9425   Mon Nov 25 10:57:14 2013 KojiUpdateCDSwoes on the X-end hostsThis morning I came in the 40m then found 
1) c1auxex was throwing out the same
 Screenshot.png 
  9430   Wed Nov 27 18:31:26 2013 KojiSummaryLSCAdittion of the ALS error signals to the LSC input matrixThe
Phase tracker outputs (= ALS X/Y error signals)
are now conveyed to the LSC model.
  
  9436   Tue Dec 3 17:08:06 2013 KojiUpdateCDScomputer problemsIt seems that the front fan unit was running
at the full speed. The fan itself seems still
OK.
  
ELOG V3.1.3-