  12141   Tue May 31 16:52:58 2016 SteveUpdatesafetyNONOPlease do not place anything on the top
of the cabinets that is not tied down. It
will end up on our head in an earth quake.
 nono.jpg 
  12140   Mon May 30 18:19:50 2016 JohannesUpdateCDSASS medm screen updateI noticed that the TRY button in the ASS
main screen was linking to LSC_TRX instead
of LSC_TRY. Gautam fixed it.
  
  12139   Fri May 27 11:54:22 2016 VarunUpdateGeneralPackage deliveryA package labelled 'UPS Ground'
has arrived.

-Varun
  
  12138   Fri May 27 02:52:53 2016 ericqUpdateLSCRestoring high BW single arm controlI've been futzing with the common mode
servo, trying to engage the AO path with
POY for high bandwidth control of a single
  
  12137   Thu May 26 18:10:48 2016 VarunUpdateGeneralSURF 2016Wrote and tested a function for downconversion.
It contains a mixer with a sinusoidal input
for modulation with the desired frequency
 input.pngoutput.png 
  12136   Wed May 25 14:29:31 2016 VarunUpdateGeneralSURF 2016Edited the AGC to include overlapping frames
yesterday. forgot to put an elog on it!

  
  12135   Wed May 25 14:21:29 2016 Max IsiUpdateGeneralSummary page configurationI have modified the c1summary.ini and c1lsc.ini
configuration files slightly to avoid overloading
the system and remove the errors that were
  
  12134   Wed May 25 11:51:40 2016 SteveUpdatesafetySURF 2016 safety


  
  12133   Wed May 25 08:32:55 2016 SteveUpdateSUSlocal EQ 3.5mLocal EQ 3.5 mag  at 2:28 UTC May
24, 2016 Rancho Cucamonga, Ca.....no damage

 
 3.5Cucam.pnglocal3.5cucam.png 
  12132   Wed May 25 02:54:09 2016 ericqUpdateGeneralOdds and endsWFS locking point seemed degraded; I hand
aligned and reset the WFS offsets as usual.

ITMX oplev recentered. While doing
  
  12131   Tue May 24 23:17:37 2016 ericqUpdateCOCFinesse modelling - mode overlap scansI think you should use the current actual
PRC & SRC cavity lengths as measured,
as it would be simplest to simply replace
  
  12130   Tue May 24 22:49:02 2016 gautamUpdateCOCFinesse modelling - mode overlap scansSummary:

Having played around with a toy finesse
model, I went about setting up a model in
 9x 
  12129   Tue May 24 17:55:17 2016 VarunUpdateElectronicsUsing AltiumContacted Charles regarding use of Altium.
Got to know that Altium is installed
on cit40m iMac in Win7 on VirtualBox.
  
  12128   Tue May 24 10:21:36 2016 ericqSummarySUSITMX Oplev loopsI did a quick measurement of the ITMX oplev
loops, both pitch and yaw have about the
same upper UGF as previous measurements with
  
  12127   Mon May 23 17:47:51 2016 VarunUpdateGeneralSURF 2016Tested the AGC today with LSC cavity transmission
signal and error signal. Not in real time
still.
 cav_tr-eps-converted-to.pdfcav_tr_out-eps-converted-to.pdferr-eps-converted-to.pdferr_out-eps-converted-to.pdf 
  12126   Mon May 23 15:51:32 2016 steveSummarySUSoplev laser summary updated 




 oplSum.png 
  12125   Mon May 23 10:55:49 2016 steveSummarySUSITMX oplev laser replaced 

     
May 23, 2016            
 ITMXoplev.png 
  12124   Fri May 20 17:36:06 2016 gautamUpdateLSCNew stands for TransMon/Oplev QPDsAs we realized during the EX table switch,
the transmitted beam height from the arm
is not exactly 4" relative to the endtable,
  
  12123   Fri May 20 00:06:19 2016 VarunUpdateGeneralSURF 2016I have written a basic version of AGC,
and have done some tests with a data file.
will do tests on whitening and agc today.
  
  12122   Thu May 19 16:29:20 2016 SteveUpdateendtable upgradeOptical layout almost complete 

 
 ETMX_4x3_closed.jpgsealedETMXenclosure.jpg 
  12121   Wed May 18 17:42:52 2016 VarunUpdateGeneralSURF 2016Finished writing the code on whitening.
I have to still test it. uploaded on github
noise cancellation repo. @eric could you
  
  12120   Wed May 18 01:10:22 2016 gautamUpdateCOCFinesse modellingI've been working on putting together
a Finesse model for the current 40m configuration.
The idea was to see if I could reproduce
 arms.pdfPRC.pdfSRC.pdfFinesse_model.zip 
  12119   Tue May 17 14:46:51 2016 SteveUpdateVACRGA scan at day 595We have good RGA scan now. There was no
scan for 3 months.
 RGAscan595d.pngpd78-560Hz-d600.png 
  12118   Tue May 17 05:50:43 2016 Varun KelkarUpdateGeneralSURF 2016Hello, I am Varun Kelkar. I will be working
at the 40m lab as a SURF student this summer
with Eric Quintero on Audio processing for
  
  12117   Sun May 15 19:48:08 2016 SteveUpdateVACrun out of N23-4 hrs ago we run out of nitrogen. We
are back to Vacuum Normal

 
 noN2.png 
  12116   Thu May 12 14:29:58 2016 gautamUpdateVACRGA back up and runningIt looks like the hardware reset did the
trick. Previously, I had just tried ssh-ing
into c0rga and rebooting it. At the time,
 RGAscan_12May2016.png 
  12115   Wed May 11 16:39:01 2016 ericqUpdateVACc0rga alive, output wonky


  
  12114   Tue May 10 03:44:59 2016 ericqUpdateLSCRelockedALSX noise is solidly within past acceptable
performance levels. The DRFPMI was locked
on four out of six attempts. 
 2016-05-10_DARMcoherence.pdf 
  12113   Sun May 8 08:39:21 2016 ranaUpdateLSCGreen PDH demod lowpassIndeed. This is why the LSC PDs have a
2f notch in addition to the 1f resonance.
In recent versions, we also put a 2f notch
  
  12112   Sat May 7 09:40:40 2016 ericqUpdateLSCGreen PDH demod lowpassAs I was looking at filter designs, it
seemed difficult to get 40dB of supression
at 2F with a bandpass without going to a
  
  12111   Fri May 6 19:08:52 2016 ranaUpdateLSCGreen PDH demod lowpassSeems weird to design a PD lowpass with
a corner at the modulation frequency. Recall
what our strategy is with the other photodetectors
  
  12110   Fri May 6 16:42:12 2016 ericqUpdateLSCGreen PDH demod lowpassI've build the filter, and it seems
to have the desired TF shape.

 pdh_lpf.pngAUX_X_PDH_OLG_May6.png 
  12109   Thu May 5 21:28:44 2016 gautamUpdateendtable upgradeInnolight PZT capacitanceI suggested
in an earlier elog that after the repair
  
  12108   Thu May 5 14:05:01 2016 ranaUpdateendtable upgradeALS status updateAll seems very fishy. Its not good to put
attenuators and filters in nilly-willy.


Once the post-PD bandpass
  
  12107   Thu May 5 14:03:52 2016 ericqUpdateLSCFurther Aux X PDH tweaksThis morning I poked around with the green
layout a bit. I found that the iris immediately
preceding the viewport was clipping the ingoing
 2016-05-05_newals.pdf 
  12106   Thu May 5 04:05:03 2016 ericqUpdateLSCAux X PDH checksWe took an OLG measurement of the green
PDH loop. It seems consistent with past measurements.
I've added a trace for the the post-mixer
 nom_noise.pngnom_olg.png 
  12105   Thu May 5 03:05:37 2016 gautamUpdateendtable upgradeALS status update[ericQ, gautam]

Today we spent some time looking
into the PDH situation at the X end. A summary
 ALS_noiseSpec_5May2016_2.pdfCoherence_5May2016.pdfimage.jpeg 
  12104   Mon May 2 19:14:18 2016 gautamUpdateendtable upgradeOptical layout almost completeWith Steve's help, I installed the
Oplev earlier today. I adjusted the positions
of the two lenses until I deemed the spot
 ETMX_wedge.pdf 
  12103   Mon May 2 17:11:55 2016 ranaUpdateCOCRC folding mirrorsAntonio/Gautam
are now developing a more up to date Finesse
model of our recycling cavities to see what
  
  12102   Mon May 2 17:06:58 2016 ranaSummaryCOCG&H optics to Fullerton/HWS for anneal testingSteve sent 4 of our 1" diameter G&H
HR mirrors to Josh Smith at Fullerton for
scatter testing. Attached photo is our total
 20160427_182305.jpg 
  12101   Fri Apr 29 16:13:36 2016 ericqUpdateLSCGreen PDH demod lowpassWe can get
as much, if not more, attenuation of the
1F line in the mixer output that we get from
 IMG_3186.jpgpdh_lpf.pngelp_liso.zip 
  12100   Fri Apr 29 16:05:23 2016 gautamUpdateendtable upgradeCleaning ETMX vacuum dirty windowAfter a second round of F.C. application,
I think the window is clean enough and there
are no residual F.C. pieces anywhere near
 IMG_0755.JPG 
  12099   Fri Apr 29 00:55:46 2016 gautamUpdateendtable upgradegreen PDH locked to XarmUsing the modulation frequency suggested
here,
I hooked up the PDH setup at the X-end and
  
  12098   Thu Apr 28 18:53:05 2016 ranaUpdateLSCGreen PDH demod lowpassOK - but give us a circuit diagram and
the expected before/after loop plots. Got
to make sure we keep the right impedance
  
  12097   Thu Apr 28 15:23:11 2016 ericqUpdateLSCGreen PDH demod lowpassThe 2F product out of the mixer is a natural
concern when demodulating. However, I think
this isn't so big of a deal in our green
  
  12096   Thu Apr 28 08:49:47 2016 SteveUpdatePEMpossible noise sources schedule
Building:        
Campus (see attached Map)        

       
 Campus_B&W_Map-2.pdf 
  12095   Thu Apr 28 00:41:08 2016 gautamUpdateendtable upgrademore progress - Transmon PD installedThe IR Transmon system is almost completely
laid out, only the QPD remains to be installed.
Some notes:
  
  12094   Wed Apr 27 15:04:47 2016 SteveUpdateendtable upgradeCleaning ETMX vacuum dirty windowIt looks very promising.

 
 1cETMX-Tcmp.jpg 
  12093   Wed Apr 27 14:06:31 2016 ranaSummaryGeneralmeeting notes
Gautam will get
help from Johannes and finish EX table by
Monday.
Steve
  
  12092   Wed Apr 27 09:45:56 2016 ranaUpdateSUSspare SOS towerBah, we need ruby slippers for all future