40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 100 of 344  Not logged in ELOG logo
    Reply  Thu Feb 21 19:55:46 2008, rana, Update, Electronics, 2 BNC Cables, 1 Tee 
I'm not sure where [COLOR=purple]Ward and Miller went to Analyzer school[/COLOR], but it was probably uncredited.
I turned it on and used 2 BNC cables and a T to hook up the source to the 2 inputs and measured the always-exciting TF of cable.
    Reply  Fri Feb 22 08:29:07 2008, Alberto, Update, Electronics, RF Monitor (StocMon) 
[quote]I put the amplifiers next to the monitor on the PSL table, layed the power and the RF SMA cables out to the rack. I'm powering the box and the amplifiers
with the power supply, waiting for someone to show me tomorrow how to connect it to the Sorensen (Steve, Ben?).
    Reply  Fri Feb 22 08:33:18 2008, Alberto, Update, Electronics, RF Monitor (StocMon) 
[quote]I put the amplifiers next to the monitor on the PSL table, layed the power and the RF SMA cables out to the rack. I'm powering the box and the amplifiers
with the power supply, waiting for someone to show me tomorrow how to connect it to the Sorensen (Steve, Ben?).
Entry  Fri Feb 22 11:11:00 2008, rob, Update, Electronics, REFLDD problem found 

I used a network analyzer that actually works to find a problem in the REFLDD electronics chain.  There was loose (=bad) SMA-BNC adaptor on the output
of channel one of the HP RF Amplifier.  It worked intermittently, so going onto the ISCT and fiddling with cables could sometimes temporarily fix the problem.
    Reply  Fri Feb 22 11:13:15 2008, rob, Update, Electronics, RF Monitor (StocMon) 
[quote] It took some times because the written procedure to start the chiller is not very precise.[/quote]

It is actually very precise.  Precisely wrong.
    Reply  Fri Feb 22 16:47:54 2008, rob, Update, Electronics, Baloney bustedHP.mov
Well I guess Rana didn't study too hard at Professor School, either.  If he'd even bothered to actually read John's entry, he might have looked at the RF
Out from the HP Analyzer.  As it is, this experience so far has been like taking your car to a highly respected mechanic, telling him it's having acceleration
problems, and then he takes a rag and wipes some dirt off the hood and then tells you "It's running fine.  That'll be 500 bucks."  
    Reply  Thu Feb 28 19:49:21 2008, rob, Update, Electronics, RF Monitor (StocMon) 

[quote]
With Ben, we hooked up the RF Monitor box into the PSL rack and created 4 EPICS channels for the outputs:
Entry  Sun Mar 23 10:42:54 2008, Valera, Summary, Electronics, RFAM of the RF stabilization box is measured RFAM.zipamplitudenoise.pdf
I reconstructed Tobin's setup to measure the RFAM after the RF stabilization box in the 166 MHz modulation path.
The setup consisted of the splitter and the mixer followed by the RF low pass filter and the SR560 (gain x100).
The RF level into splitter was 20 dBm. The Mini-Circuits ZLW-3H (17 dBm LO) mixer was used. The LO was taken 
Entry  Mon Mar 24 13:03:54 2008, rob, Update, Electronics, HP4195A is back 


[quote]The swept sine output looks totally normal from 500Mhz to 150MHz (measuring ~220mVrms below 300MHz -- 0dBm), where it abruptly transitions to a
Entry  Thu Jun 26 22:08:33 2008, Jenne, Update, Electronics, 3.7MHz bandstop filter in MC Servo  MCLoopGainBoth.pngTP1ASpectrumBoth.pngQmonWithFilt.pngMCOut2WithFilt.png
The 3.7MHz elliptical bandstop filter that I made during my SURF summer is now installed in the MC servo loop to reduce the noise at 3.7MHz. 

I have taken transfer functions with and without the filter between TP1A and TP2A, with EXCA at -20dBm, using the HP4195A Network Analyzer.  I have also
Entry  Fri Jun 27 18:03:46 2008, Jenne, Update, Electronics, Another bad cable in the MC servo 
Eric was helping me to measure the response of the LO input on the MC's Demod board, and when we disconnected the end of the cable between the demod board
and the delay line phase shifter for the 29.5MHz oscillator, we noticed that the phase shifter's end of the cable was loose, like the connector wasn't
fully connected. When we checked it by wiggling the connector, the SMA end fell off.  I made a new SMA end for the cable, and reinstalled the cable.  The
Entry  Fri Jun 27 18:21:01 2008, Jenne, Update, Electronics, Response of the LO input on the MC demod board 
The alarm handler has been flipping out saying that the LO input of the MC's demod board is too low, so at Rana's suggestion, Eric and I measured the response
of the LO input.  We used an SR345 function generator at 29.485MHz and several different amplitudes to make a table.  The demod board should see an input
from the LO between 0-2dBm.  When I measured what was going into the LO input from the 29.5MHz delay line phase shifter, the LO input was seeing 4dBm.
Entry  Mon Jun 30 15:56:22 2008, Jenne, Update, Electronics, Fixing the LO demod signal  
To make the alarm handler happy, at Rana and John's suggestion I replaced R14 of the MC's Demod board, changing it from 4.99 Ohms to 4.99 kOhms.  This increased
the gain of the LO portion of the demod board by a factor of 10.  Sharon and I have remeasured the table of LO input to the demod board, and the output
on the C1:IOO-MC_DEMOD_LO channel:
Entry  Tue Aug 26 18:19:16 2008, rana, Omnistructure, Electronics, Resistor Noise at the 40m SEI-RN_RNM.pdf
As Stefan points out in his recent ISS ilog entries at LLO, Daniel [COLOR=darkgreen]Sigg recently wrote a
recommendation memo on resistor and capacitor[/COLOR] choices: [URL=http://www.ligo.caltech.edu/docs/T/T070016-A/T070016-A.pdf]T070016[/URL].
Entry  Wed Sep 3 18:43:19 2008, Yoichi, Configuration, Electronics, Two more active probes Tektronix-P6201-active-probe.pdf
I found two active probes, an HP41800A and a Tektronix P6201.
Thanks John for telling me you saw them before.
Now we have three active probes, wow !
Entry  Wed Sep 10 13:28:25 2008, Yoichi, Summary, Electronics, IOO rack lost -24V (recovered) 
Alberto, Yoichi

This morning, the MC suddenly started to be unwilling to lock.
Entry  Wed Oct 8 22:23:43 2008, Yoichi, Configuration, Electronics, Electronics work bench cleanup Cleanup.jpg
Yesterday, I cleaned up the electronics work bench. I figured that keeping the work bench
in order has larger effect on the work efficiency than buying expensive soldering stations. 
Whoever works there should clean up the table after the work to the state shown on 
Entry  Fri Nov 14 17:41:50 2008, Jenne, Omnistructure, Electronics, Sweet New Soldering Iron newSolderingIron.JPG
The fancy new Weller Soldering Iron is now hooked up on the electronics bench.  

Accessories for it are in the blue twirly cabinet (spare tips of different types, CD, and USB cable to connect it to a computer, should we ever decide
Entry  Mon Nov 17 11:01:15 2008, Alberto, HowTo, Electronics, Calibrating the Frequency Standard of the Marconi 2023ASeriesOperatingManual.pdfSRS_FS275_Rubidium_Frequency_Standard.pdf
I locked the [COLOR=purple][I]SRS Rubidium Frequency Standard FS275[/I][/COLOR] to the the 1pps from the GPS. The specs from the manual provide a frequency
accuracy of 5x10^-11, that is 5x10-4 @ 10 MHz, since this is the reference signal frequency we're are going to use.
The Marconi internal frequency standard is provided by a TCXO oscillator. The instrument can be set in either one of these ways: 1) Indirect Synchronization,
Entry  Wed Nov 19 10:32:11 2008, Alberto, Configuration, Electronics, All the Marconi Set to the Rubidium Frequency Standard 
I placed the SRS Rubidium FS275 over the PSL rack, next to the frequency counter. This one and the Marconi on the PSL rack have been connected to the 10MHz
output of the frequency standard. I set also the first Marconi, the one that used to drive the others, to external, direct frequency reference. [I]Now
[SIZE=3]it reads 166981718 Hz versus 166981725 Hz[/SIZE] measured by the frequency counter[/I]: 8 Hz difference.
    Reply  Wed Nov 19 18:02:18 2008, rana, Configuration, Electronics, All the Marconi Set to the Rubidium Frequency Standard 
Not sure what was going on before. I changed the frequency counter to use an AC coupled input, and had it average
for 50 seconds. The output now agrees with the Marconi front panel to less than 1 Hz. Its still not 0.000 Hz,
but not bad.
Entry  Tue Dec 30 18:51:18 2008, rana,yoichi, Configuration, Electronics, Illuminator Power Supply reset 
[COLOR=blue][B]We noticed that none of the illuminators were working.[/B][/COLOR]

The switches were off on all the ports. After turning them on it still didn't work.
Entry  Sat Jan 24 11:50:24 2009, Alberto, Configuration, Electronics, Photodiode Filters' Transfer Functions 
I found an elog entry by Jenne with the measurement of the transfer functions of the filters of some of our photodetectors. Since it might turn useful to
us these days, while I'm thinking about posting them on the wiki sometime, I also copy the link here:
[URL=http://www.ldas-sw.ligo.caltech.edu/ilog/pub/ilog.cgi?group=40m&task=view&date_to_view=08/18/2006&anchor_to_scroll_to=2006:08:18:13:58:35-jenned]Jenne's
Entry  Mon Feb 16 23:09:52 2009, rana, Update, Electronics, MC Servo Board offset gone bad! mcoff.png
The attached plot shows that someone broke the MC_SUM_MON channel around 10:30 AM this past Wednesday the 11th. This is the EPICS monitor of the MC error
point.
Come forward now with your confession and I promise that I won't let Steve hurt you.
Entry  Thu Feb 19 22:40:33 2009, Kiwamu, Update, Electronics, PSL angle QPD 
I checked a broken QPD, which was placed for PSL angle monitor, and finally I cocluded one segment of the quadrant diode was broken.
The broken segment has a offset voltage of -0.7V after 1st I-V amplifier. It means the diode segment has a current offset without any injection
of light.
Entry  Mon Mar 2 16:27:40 2009, Alberto, Configuration, Electronics, MC Drum Mode SR560 Preamplifier Replaced 
Today I checked out the SR560 around the lab. I confirmed that the one with the label "channel A noisy" is effectively mulfuctioning.
It was coonected to the lock-in amplifier set up for the drum mode peak readout.
I repleaced that with a working one.
Entry  Mon Mar 16 15:19:52 2009, Osamu, DAQ, Electronics, SR785 
I borrowed SR785 to measure AA, AI noise and TF.
Entry  Mon Mar 30 15:51:27 2009, steve, Update, Electronics, HP4291A left the lab to be repaired 
Eric Gustafson is handling the old HP4291A rehabilitation. Tarac picked both units up today.
March of 2008 Tucker Electronics failed to fix it's intermittent ~25MHz 0.5V oscillation at the swept sine output
See 40m-elog id:398 on 3-24-2008 by Rob Ward
Entry  Sun Apr 12 19:31:43 2009, rana, Summary, Electronics, Amphony 2500 Headphones 
We bought the Amphony 2500 Digital Wireless headphones recently. The other cheapo headphones we have are OK for control room use, but have a lot of noise
and are, therefore, not useful for noise hunting.
Entry  Wed Jun 10 01:52:34 2009, Alberto, Update, Electronics, MC length and Marconis' frequencies 
Pete, Rob, Alberto,
yesterday we thought that some of the problems we were having in locking the IFO might be related to a change of the length of the mode cleaner.
So today we decided to measure it again.
Entry  Tue Jun 16 20:03:41 2009, Alberto, Update, Electronics, Requirements on Wenzel Multiplier SummaryOfResult.pdf
For the 40m Upgrade, we plan to eliminate the Mach-Zehnder and replace it with a single EOM driven by all three modulation frequencies that we'll need: f1=11MHz, f2=5*f1=55MHz,
fmc=29.5MHz.
Entry  Wed Jul 8 18:46:56 2009, Dmass, AoG, Electronics, Beam Scan Funky beamscanhead3.pngbeamscanhead6.png
The beam scan (which has been living in the bridge subbasement for a bit now) is in a state of imperfection.
I noticed that:

    The waist reading seems to change by not insignificant amounts as you move the spot across the head, even for just small perturbations
Entry  Mon Sep 28 23:13:14 2009, Jenne, Configuration, Electronics, Rob is breaking stuff.... 
Koji and I were looking for an extender card to aid with MZ board testing.  Rob went off on a quest to find one.  He found 2 (in addition to
the one in the drawer near the electronics bench which says "15V shorted"), and put them in some empty slots in 1X1 to test them out.  Somehow,
this burned a few pins on each board (1 pin on one of them, and 3 pins on the other). We now have 0 functioning extender cards: 
    Reply  Tue Sep 29 16:14:44 2009, rob, Configuration, Electronics, Rob is breaking stuff.... 


    
        
            Quote:
        
        
            
            Koji and I were looking for an extender card to aid with MZ board testing.  Rob went off on a quest to find one. 
Entry  Wed Oct 7 11:18:40 2009, kiwamu, Summary, Electronics, racks of electronics 
 
I took the pictures of all racks of electronics yesterday, and then uploaded these pictures on the wiki.
http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics
Entry  Sun Oct 18 19:55:45 2009, rana, Configuration, Electronics, IP POS is back: ND filter gone, new resistors in IMG_0068.JPGIMG_0072.JPG
Its back in and re-centered. Our next move on IPPOS should be to replace its steering mirror with something bigger and more rigid.
Electronics changes:
20K -> 3.65 K  (R6, R20, R42, R31) (unused)
    Reply  Sun Oct 18 22:06:15 2009, rana, Configuration, Electronics, IP POS is back: ND filter gone, new resistors in Untitled.png
I tried to compare the IP_POS time series with the IPANG and MC_TRANS but was foiled at first:
1) The IPANG scan rate was set to 0.5 second, so it doesn't resolve the pendulum motions well. Fixed in
the .db file.
    Reply  Mon Oct 19 14:48:15 2009, rana, rob, Summary, Electronics, piezo jena measuring box PA160153.JPGPA160151.JPG
Attached is the schematic of the Piezo Jena driver measuring box made in a Pomona box:

[CODE]
Entry  Wed Nov 11 20:57:06 2009, kiwamu, Update, Electronics, Multi-resonant EOM --- LC tank circuit --- DSCN0160.JPGLCtank_complete.png
I have been working about multi-resonant EOM since last week.
In order to characterize the behavior of the each components, I have made a simple LC tank circuit.
You can see the picture of the circuit below.
Entry  Fri Nov 13 03:38:47 2009, kiwamu, Update, Electronics, multi-resonant EOM --- impedance of LC tank circuit ---- LCtank_impedance.pngLCtank_model.png
I have measured the impedance of the LC tank circuit which I referred on my last entry.
The configuration of the circuit is exactly the same as that time.
In order to observe the impedance, by using Koji's technique I injected
Entry  Fri Nov 13 05:03:09 2009, kiwamu, Update, Electronics, multi-resonant EOM --- input impedance of LC tank ---- input_impedance.pnginput_impedance2.png
I measured the input impedance of the LC tank circuit with the transformer. The result is attached.
It looks interesting because the input impedance is almost dominated
by the primary coil of
the transformer with inductance of 75nH (see attachment 1).
The impedance at the resonance is ~100 [Ohm], I think this number
Entry  Tue Nov 17 21:10:35 2009, rana, Summary, Electronics, Busby Low Noise Box: Photos and Upgrades IMG_0217.JPGbusby-noise.png

It looked like the Busby Low Noise Box had too much low frequency noise and so I upgraded it. Here is a photo of the inside - I have changed
    Reply  Wed Nov 18 00:38:33 2009, rana, Summary, Electronics, Voltage Noise of the SR560's OUTPUTs (the back panel) sr560.png
I've measured the voltage noise of the SR560's lead acid battery outputs; they're not so bad.
Steve ordered us some replacement lead-acid batteries for our battery powered pre-amps (SR560). In the unit he replaced, I measured the noise using
the following setup:
Entry  Wed Nov 18 14:55:59 2009, kiwamu, Update, Electronics, multi-resonant EOM --- circuit design ---- whole_circuit.pngdesigned.pngmont.png
The circuit design of multi-resonant EOM have proceeded.
By using numerical method, I found the some best choice of the parameters (capacitors and inductors).
In fact there
are 6 parameters (Lp, L1, L2, Cp, C1, C2) in the circuit to be determined.
Entry  Wed Nov 18 16:58:36 2009, kiwamu, Update, Electronics, multi-resonant EOM --- EOM characterization --- EOM_impedance.png
In designing the whole circuit it is better to know the characteristic of the EOM.
I made impedance measurement with the EOM (New Focus model 4064) and I found it has capacitance of 10pF.
This is good agreement with the data sheet which says "5-10pF".
    Reply  Wed Nov 18 22:38:17 2009, Koji, Update, Electronics, multi-resonant EOM --- EOM characterization --- 
How can I get those values from the figure?


    
        
            Quote:
        
        
            
Entry  Wed Nov 25 20:44:48 2009, kiwamu, Update, Electronics, Multi-resonant EOM --- Q-factor ---- trans.pngeq1.pngimpedance.pngeq2.png
Now I am studying about the behavior of the Q-factor in the resonant circuit because the Q-factor of the circuit directly determine the performance as
the EOM driver.
Here I summarize the fundamental which explains why Q-factor is important.
    Reply  Thu Nov 26 02:08:34 2009, Koji, Update, Electronics, Multi-resonant EOM --- Q-factor ---- 
The key point of the story is:
"The recipe to exploit maximum benefit from a resonant EOM"
- Make a resonant EOM circuit. Measure the impedance 
    Reply  Sat Dec 12 07:36:56 2009, rana, HowTo, Electronics, How to Measure the Length of a Cable: Interferometry 
Need to measure the length of the
cable, but too lazy to use a measuring tape?
Then you too can become an expert cable length measurer by just using
Entry  Mon Dec 21 01:14:08 2009, rana, Summary, Electronics, Noise measurement of the Rai Weiss FET preamp box IMG_0242.JPGPicture_2.pngRWnoise.png
 I shorted the input to the box and then put its output into the SR560 (low noise, G = 100, AC). I put the output of the SR560 into the SR785.
*** BTW, the 2nd channel of the SR785 is kind of broken. Its too noisy by a factor of 100. Needs to go back for repair once we get started in the
vac.
ELOG V3.1.3-