40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 341 of 341  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Wed Dec 18 03:29:48 2013, Den, Update, LSC, yarm locked on mc MC_ARM.pdf
As a CM slow path test I locked free swinging yarm by actuating on MC length with bandwidth of 200 Hz. Crossover with AO is not stable so far.
I used xarm as an ool frequency noise sensor. MC2 violin mode is at 645 Hz, I have added a notch filter to LSC-MC2 bank.
Entry  Sat May 17 14:48:06 2014, den, Update, PEM, yend sei isolation kit is set IMG_1405.JPGIMG_1406.JPG
Yend seismometer isolation kit (elog 8461) hosts Guralp seismometer. I made a cable for inside
connection, assembled the kit and relocated the instrument from its previous position at the yend inside the kit.
Seismometer is connected to the readout box and running.
Entry  Mon Jul 7 08:13:41 2014, steve, Update, General, yes,there was firework 8days.png
 
Entry  Mon Apr 19 13:23:03 2010, josephb, Configuration, Computers, yum update fixed on control room machines 
I went to Ottavia, and tried running yum update.  It was having dependancy issues with mjpegtools, which was a rpmforge provided package. 
In order to get it to update, I moved the rpmforge priority above (a lower number) that of epel ( epel -> 20 from 10, rpmforge -> 10 to 20). 
This resolved the problem and the updates proceeded (all 434 of them). yum update on Ottavia now reports nothing needs to be done.
Entry  Thu Mar 5 02:24:19 2009, rana, Configuration, Computers, yum.repos.d 
I added the following repos which I found on allegra to megatron and then did a 'yum install sshfs' on both machines:
allegra:yum.repos.d>l
total 28
Entry  Tue May 5 09:22:46 2009, caryn, Update, PEM, zeros zerotest2.pngzerotest.png
For several of the channels on the PEM ADCU, zeros are occuring at the same time. Does anyone know why that might happen or how to fix it?
    Reply  Thu Jun 7 12:49:50 2012, Jamie, Update, Computers, zita network configured 
Added zita to the martian host table, and configured his network accordingly:

zita            A       192.168.113.217

https://wiki-40m.ligo.caltech.edu/Martian_Host_Table
    Reply  Tue Nov 12 21:50:01 2013, rana, Update, , zita network configured 
 
 I installed 'nfs-client' on zita (the StripTool terminal). It now has mounted all the shared disks, but still can't do StripTool since its
a 32-bit machine and our StripTool is 64.
Entry  Wed Jun 6 22:25:05 2012, Jamie, Update, Computers, zita now running ubuntu 10.04 
I'll finish the rest of the config to turn it into a full-fledged workstation tomorrow.
    Reply  Wed Nov 6 17:45:34 2019, gautam, Update, LSC, ~ 
Here is a comparison of the response of various DoFs in our various RFPD sensors for two different CARM offsets. Even in the case of the smaller CARM
offset of ~1kHz, we are several linewidths away from the resonance. Need to do some finesse modeling to make any meaningful statement about this - why
is the CARM response in REFL11 apparently smaller for the smaller CARM offset?
ELOG V3.1.3-