  17613   Fri Jun 2 11:47:33 2023 KojiUpdatePEMMass for temperature controlHow about measuring the actual weight with
a scale? There are a couple of scales on
Yuta's desk.
  
  17614   Fri Jun 2 16:45:46 2023 advaitUpdatePEMMass for temperature controlThanks, I was actually looking for a scale
earlier but could not find it after asking
a couple of people. One of the scales reads
  
  17615   Fri Jun 2 17:01:20 2023 ReubenUpdateALSGetting comfortable with the ALS[Reuben, Radhika]

Checked out the AUX PDH locking
system at the XARM. Started by locking the
 test.pdf2023-06-01_XAUX_PDH_OLTF_20230601_112313_Traces.csv 
  17616   Fri Jun 2 19:03:57 2023 PacoUpdateCDSC1SUS DAC failure (Re: ITMX UL coil and BS oplev rms)Vertex
SUS DAC-0 card is kaput 
 actcalibITMBS_20230602Failure.pngPXL_20230603_005109646~2.jpgBS_PRM_ITMX_ITMY_DACTest.pngSRM_MC1_MC2_MC3_DACTest.png 
  17618   Sat Jun 3 19:56:59 2023 PacoUpdateCalibrationITMY calibration with ALS and swept lineITMY
actuator calibrated with higher resolution
using ALS
 itmy_act_sweep_alscal.pdfitmy_act_novio_sweep_alscal.pdf 
  17619   Mon Jun 5 10:01:41 2023 YehonathanUpdateSUSETMX fast-channel-watchdog was implemented{Mayank, Yehonathan}

We updated the c1auxex db file
ETMXaux.db. Backup was saved under the same
 Screenshot_2023-06-05_11-14-34.png 
  17620   Mon Jun 5 15:34:27 2023 PacoUpdateCDSC1SUS DAC-0 replacementVertex
c1sus DAC-0 card replaced 
 6x 
  17621   Mon Jun 5 18:42:13 2023 PacoUpdateCalibrationITMY calibration with ALS and swept lineITMY
actuator calibrated with higher resolution
using ALS after c1sus-DAC0 replacement
 ITMY_ALSCAL_Screenshot_2023-06-06_10-34-50.png 
  17622   Tue Jun 6 21:23:37 2023 advaitUpdatePEMEarly heater prototypePaco suggested I start putting together
the beginnings of a heating system so that
I can get a better idea of what parts and
 prototype_heater.jpeg71d670c9-368c-4409-b2a2-ba04390b6a65.jpeg 
  17623   Wed Jun 7 10:35:42 2023 RadhikaUpdateDaily ProgressT&R measurement setup for PR2[Radhika, Aaron, Mayank, Paco]

Here I'll describe the setup
for 
 IMG_4916.PNGlightwaveNPRO.pdfIMG_4908.JPGIMG_4912.PNG 
  17624   Wed Jun 7 15:51:47 2023 KojiUpdateCalibrationITMY calibration with ALS and swept lineCan you make this flat by compensating
the gain bump due to the UGF of the phase
tracker?
  
  17625   Wed Jun 7 17:05:36 2023 yutaSummaryLSCRF FPMI recovered after c1sus DAC card replacement[Paco, Yuta]

 Screenshot_2023-06-07_16-17-15_OLTFs_FPMI.pngScreenshot_2023-06-07_15-51-09_MC1MC3_FM9_OFF.pngScreenshot_2023-06-07_17-04-18_FPMI60Hznoise_AFTERFIX.png 
  17626   Thu Jun 8 10:31:46 2023 yutaUpdateCDSc1sus2 all FE models crashed spontaneously again and IMC/vertex optics damping stopped[Mayank, Yuta]

We noticed that 
 Screenshot_2023-06-08_10-36-08_Yarm.pngScreenshot_2023-06-08_10-36-51_c1sus2.pngScreenshot_2023-06-08_10-41-16_c1x02.png 
  17627   Fri Jun 9 11:12:05 2023 RadhikaUpdateDaily ProgressT&R measurement setup for PR2After talking with Koji, the layout
was revised as in Attachment 1. Instead of
using reflection from the first PBS to obtain s-polarization,
 IMG_4927.PNGIMG_4925.PNGIMG_4932.JPGIMG_4936.JPG 