ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
16961
|
Tue Jun 28 23:10:34 2022 |
Yehonathan | Update | BHD | Measurement of AS55 demod board conversion factor | {Yuta, Yehonathan}
We measured the AS55 demod board
conversion from the amplitude of a 55MHz |
|
16960
|
Tue Jun 28 22:27:11 2022 |
Yehonathan | Update | BHD | Measurement of input and output electronics noise | {Yuta, Yehonathan}
For MICH noise budgeting we measure
the input electronics noise which includes |
 |
16959
|
Tue Jun 28 18:53:16 2022 |
rana | Summary | ALS | ALS beat allan deviation (XARM) | what's the reasoning behind using df/f_beat
instead of df/f_laser ?
|
|
16958
|
Tue Jun 28 18:19:09 2022 |
Tomislav | Update | Electronics | Electronics noise | I measured electronics noise of WFSs and
QPD (of the WFS/QPD, whitening, ADC...) by
closing PSL and measuring the error signal. |
 |
16957
|
Tue Jun 28 17:07:47 2022 |
Anchal | Update | Calibration | Added Beatnote channels in demodulation of c1cal | I added today demodulation of C1:LSC-BEATX/Y_FINE_I/Q
in the c1cal demodulation where different
degrees of freedom can be dithered. For McCal |
|
16956
|
Tue Jun 28 16:59:35 2022 |
Paco | Summary | ALS | ALS beat allan deviation (XARM) | [Paco]
I took ~ 7 minutes of XALS beatnote
data with the XAUX laser locked to the XARM |
 |
16955
|
Tue Jun 28 16:26:58 2022 |
Cici | Summary | General | Vector fitting open loop transfer function/Audio cancellation of optical table enclosure | [Deeksha, Cici]
We attempted to use vectfit to
fit our earlier transfer function data, and |
   |
16954
|
Tue Jun 28 14:24:23 2022 |
yuta | Update | BHD | BHD DC PD signals now also sent to c1lsc to circumvent IPC error | [JC, Yuta]
To circumvent IPC error sending
BHD DC PD signals from c1sus2 to c1lsc, DB9 |
  |
16953
|
Tue Jun 28 09:03:58 2022 |
JC | Update | General | Organizing and Cleaning | The plan for
the tools in 40m
As of right now, there are 4 tool |
|
16952
|
Mon Jun 27 18:54:27 2022 |
yuta | Update | LSC | Modulation depths measurement using Yarm cavity scan | [Yehonathan, Yuta]
EDITED
by YM on 22:11 June 27, 2022 to correct for |
|
16951
|
Mon Jun 27 13:39:40 2022 |
Deeksha | Update | Electronics | Setting up the MokuLab | [Cici, Deeksha]
On Friday Cici and I set up the
Mokulab to take readings of our loop. The |
|
16950
|
Mon Jun 27 13:25:50 2022 |
Cici | Update | General | Characterizing the Transfer Loop | [Deeksha, Cici]
We first took data of a simple
low pass filter, and attempted to perform |
   |
16949
|
Mon Jun 27 12:32:45 2022 |
yuta | Update | IOO | WFS issues fixed | |
|
16948
|
Sat Jun 25 22:18:41 2022 |
Tomislav | Update | ASC | Simulation and reality comparisons | In the attachment please find plots comparing
controller output, local damping output,
and error signals. |
  |
16947
|
Sat Jun 25 20:23:59 2022 |
Koji | Update | IOO | WFS issues | I could run the WFS servo (6dofs) for more
than 15min by flipping the sign for the MC2
Pit and WFS1 Yaw. (See attachments) |
 |
16946
|
Sat Jun 25 14:29:48 2022 |
Anchal | Update | IOO | WFS issues | This issue is very weird and still unresolved.
Without WFS loops, we'll have to realign
IMC often and we might loose IMC alignment |
|
16945
|
Fri Jun 24 17:16:59 2022 |
Paco | Update | ALS | XAUX cable in control room | [JC, Paco]
We took the long BNC cable that
ran from ETMX to ETMY and ran it from ETMX |
|
16944
|
Fri Jun 24 13:29:37 2022 |
Yehonathan | Update | General | OSEMs from KAGRA | The box was given to Juan Gamez (SURF)
|
|
16943
|
Fri Jun 24 12:13:16 2022 |
JC | Update | IOO | WFS issues | [Yuta, JC]
It seems that early this morning
MC got very misaligned. Yuta was able to |
|
16942
|
Thu Jun 23 15:05:01 2022 |
Water Monitor | Update | Upgrade | Water Bottle Refill | 22:05:02 UTC Jordan refilled his water
bottle at the water dispenser in the control
room. |
|
16941
|
Wed Jun 22 19:41:13 2022 |
Koji | Update | LSC | Daily alignment work; POY trouble solved | Before the final measurement of the DC
values for the transmissions, I aligned the
PMC. This made the PMC trans increased from |
|
16940
|
Wed Jun 22 18:55:31 2022 |
yuta | Update | LSC | Daily alignment work; POY trouble solved | [Koji, Yuta]
I found that Yarm cannot be locked |
 |
16939
|
Wed Jun 22 17:04:06 2022 |
Deeksha | Summary | Electronics | Characterising the AUX control loop | [Cici, Deekha]
Setup loop to measure transfer
function of control loop - the aim is |
  |
16938
|
Wed Jun 22 14:44:03 2022 |
Anchal | Update | BHD | Fixed DC error in c1su2, added new library model for suspensions | The 0x2000 error in c1su2 happens whenever
we make it and install it as the default
data acquisition rates are too much in the |
|
16937
|
Tue Jun 21 22:22:37 2022 |
Tomislav | Update | ASC | Plots | In the attachment please find a comparison
of error signals of simulation and reality
after including air turbulence as input noise. |
|
16935
|
Tue Jun 21 21:17:16 2022 |
yuta | Update | BHD | RTS models for BHD added but PCIE error remaining | [Anchal, Yuta]
RTS
models for BHD homodyne phase control (c1hpc) |
   |
16934
|
Tue Jun 21 18:41:46 2022 |
Tomislav | Update | ASC | Simulation plot | In the attachment please find a comparison
of error signals of simulation and reality.
For C1:IOO-WFS1/2_PIT_IN1 excess signal ('belly') |
|
16933
|
Tue Jun 21 14:59:22 2022 |
Cici | Summary | General | AUX Transfer Function Loop Exploration | [Deeksha, Cici]
We learned about the auxillary
laser control loop, and then went into the |
|
16932
|
Tue Jun 21 14:17:50 2022 |
yuta | Configuration | BHD | BHD DCPDs re-routed to c1sus2 | After discussing with Anchal, we decided
to route BHD related PD signals directly
to ADC of c1sus2, which handles our new suspensions |
 |
16931
|
Tue Jun 21 08:36:50 2022 |
Anchal | Update | SUS | Diagonalized input matrices for LO1, freeSwing on ITMY and ITMX | Over the weekend, I ran freeSwing test
with sequential kicks in specific DOFs for
LO1, ITMY, ITMX. LO1 results were successfully |
|
16930
|
Mon Jun 20 19:46:04 2022 |
Tomislav | Update | ASC | Simulation plots | In the attachment please find IMC ASC simulation
plots. Let me know what you think, if you
want some other plots, and if you need any |
    |
16929
|
Fri Jun 17 16:22:21 2022 |
yuta | Update | LSC | Actuator calibration of BS. ITMX, ITMY, updated MICH displacement spectra from c1cal | Following what we have done in 2013 (40m/8242),
actuator calibration was done using MICH. |
6x |
16928
|
Fri Jun 17 13:07:08 2022 |
Koji | Update | BHD | Comparison of MICH OLTF model with measurement | I'm curious why the actual OLTF included
the 60Hz comb...? It is undesirable to have
such structure in the OLTF around the UGF |
|
16927
|
Fri Jun 17 12:05:32 2022 |
Yehonathan | Update | BHD | Comparison of MICH OLTF model with measurement | I should write down what I didn't include
for completeness:
1. AA filters |
|
16926
|
Thu Jun 16 19:49:48 2022 |
Cici | Update | General | Using the SR785 | [Deeksha, Cici]
We used a python script to collect
data from the SR785 remotely. The SR785 is |
|
16925
|
Thu Jun 16 18:30:07 2022 |
Anchal | Update | SUS | New diagonalized input matrices applied | I used the same fre swing data to diagnolize
input matrices of following optics:
MC1, MC2, MC3 |
|
16924
|
Thu Jun 16 18:23:15 2022 |
Paco | Configuration | BHD | Recovering LO beam in BHD DCPDs | [Paco, Yuta]
We recovered the LO beam on the
BHD port. To do this, we first tried reverting |
|
16923
|
Thu Jun 16 17:40:15 2022 |
Yehonathan | Update | BHD | Comparison of MICH OLTF model with measurement | I made some progress in modeling MICH loop.
Putting all the LSC and SUS filters
together with the MICH Finesse model I constructed |
|
16922
|
Thu Jun 16 15:29:03 2022 |
yuta | Update | PSL | PMC input beam aligned again, IMC | [Paco, Tomislav, Yuta]
Somehow, when we were trying to measure |
|
16921
|
Wed Jun 15 17:12:39 2022 |
Cici | Summary | General | Preparation for AUX Loop Characterization | [Deeksha, Cici]
We went to the end Xarm station
and looked at the green laser setup and electronics. |
|
16920
|
Wed Jun 15 17:03:17 2022 |
yuta | Update | SUS | ITMY ULCOIL issue solved, loose connection in sat amp box | [Anchal, Yuta]
We fixed the issue of ITMY ULCOIL |
   |
16919
|
Wed Jun 15 15:45:37 2022 |
yuta | Update | SUS | LO1 LLCOIL now working, it was loose connection | We tracked the issue of LO1 LLCOIL not
actuating LO1, and found that the DB9 cable
from the coil driver to the sat amp was loose. |
  |
16918
|
Wed Jun 15 15:07:07 2022 |
Koji | Update | SUS | LO2 SUS stuck fixed | I checked the state of the LO2 suspension.
I found that the coil driver Enable
Mon was all red. |
 |
16917
|
Wed Jun 15 15:03:41 2022 |
Koji | Update | PSL | PMC input beam aligned | The commissioners complained about the
PMC alignment. The PMC input beam was aligned.
It made the transmission improved from 0.72 |
 |
16916
|
Wed Jun 15 07:26:35 2022 |
JC | Update | VAC | Beginning Pumpdown | [Jordan, JC]
Jordan and I went in to retore
the Vacuum System back to it's original |
|
16915
|
Tue Jun 14 20:57:15 2022 |
Anchal | Update | ASC | Yarm ASS working now | I finally got YARM AS to work today. It
is hard to describe what worked, I did a
lot of monkey business and some dirty offset |
|
16914
|
Tue Jun 14 19:34:06 2022 |
yuta | Update | SUS | Resonant frequency identification from the free swing test | [JC, Anchal, Yuta]
We are working on resonant frequency
idendification from the free swing test done |
7x |
16913
|
Tue Jun 14 18:45:43 2022 |
Anchal | Update | SUS | LO2 lower magnets are stuck in coil, won't come off | [Anchal, Yuta]
In the weekend, I ran a free swing
test on all optics. During this test, LO2 |
|
16912
|
Tue Jun 14 08:41:36 2022 |
JC | Update | OPLEV Tables | BS Oplev Table Sketch | [JC]
Lately, I have been working on
a 3d sketch of the BS OPLEV Table on SolidWorks. |
|
16911
|
Mon Jun 13 20:26:09 2022 |
yuta | Update | ASC | Yarm ASS re-tuning in progress -part 2- | [Anchal, Yuta]
We are still in the progress of re-commissioning |
 |