  16849   Thu May 12 20:11:18 2022 AnchalUpdateBHDBHDBS Output beams steered out to ITMY tableI successfully steered out the two output
beams from BHD BS to ITMY table today. This
required significant changes on the table,
 signal-2022-05-12-201844.jpeg 
  16850   Thu May 12 20:24:29 2022 yutaUpdateBHDPOX and POY investigation[Anchal, Yuta]

We checked POX and POY RF signal chains
 POY.JPG 
  16851   Fri May 13 14:26:00 2022 JCUpdateAlignmentLO2 Beam[Yehonathan, JC]

Yehonathan and I attempted to align
the LO2 beam today through the BS chamber
  
  16852   Fri May 13 18:42:13 2022 PacoUpdateAlignmentITMX and ITMY sat amp failures[Yuta, Anchal, Paco]

As described briefly by JC, there
were multiple failure modes going during
  
  16853   Sat May 14 08:36:03 2022 ChrisUpdateDAQDAQ troubleshootingI heard a rumor about a DAQ problem at
the 40m.

To investigate, I tried retrieving
  
  16854   Mon May 16 10:49:01 2022 AnchalUpdateDAQDAQ troubleshooting[Anchal, Paco, JC]

Thanks Chris for the fix. We are
able to access the testpoints now but we
  
  16855   Mon May 16 12:59:27 2022 ChrisUpdateDAQDAQ troubleshootingIt looks like the RFM problem started a
little after 2am on Saturday morning (attachment
1). It’s subsequent to what I did,
 timeseries.pngerr.png 
  16856   Mon May 16 13:22:59 2022 yutaUpdateBHDREFL and AS paths aligned at AP tableAfter Xarm and Yarm were aligned by Anchal
et al, I aligned AS and REFL path
in the AP table.
 REFLPOP.JPGPOPAS.JPG 
  16857   Mon May 16 14:46:35 2022 TommyUpdateElectronicsRFSoC MTS WorkWe followed the manual's guide for
setting up MTS to sync on external signal.
In the xrfdc package, we update the RFdc
  
  16858   Mon May 16 16:13:01 2022 YehonathanUpdateBHDInitial BHD modeling: Damped suspension modelI was finally able to set up a stable suspension
model with the help of Yuta and I'm now
ready to start doing some MICH noise
 Damped_SUS.pngETMY_SUSPOS_GOL.pdfSUS_Response.png 
  16859   Mon May 16 19:14:17 2022 AnchalUpdateBHDCamera set on AS path and BHDBS output path[Anchal, Paco, Yuta]


We aligned AS path avoiding
any clipping to the AP table where we setup
  
  16860   Tue May 17 18:43:38 2022 AnchalUpdateBHDPlaced SRM in ITMY Chamber[Anchal, Paco, Yuta]

SRM Placement


SRM
was moved from its parked location to the
  
  16861   Wed May 18 08:30:29 2022 PacoUpdateBHDSRM OpLev[Paco]

The SRM Oplev injection and detection
paths interfere heavily with the POY11. Due
  
  16862   Wed May 18 09:02:52 2022 AnchalUpdateBHDWFS1 PD centeredI centered WFS1 PD so that IMC WFS Servo
does not go out of range.

 
  
  16863   Wed May 18 17:23:15 2022 AnchalUpdateBHDPlaced PRM in BS Chamber[Anchal, Paco, Yuta, JC]

SRM Oplev setup


We
setup SRM oplev path for the aligned position
  
  16864   Thu May 19 08:51:40 2022 PacoUpdateBHDSRM OpLev[Paco, Ian]

After agreement from Yuta/Anchal,
I moved POYM1 yaw to clear the aforementioned
  
  16865   Thu May 19 18:56:08 2022 yutaUpdateBHDCurrent OSEM sensor values with all the suspensions alignedCurrent OSEM sensor values with all the
suspensions aligned are attached.
For 'BS','ITMX','ETMX','ITMY','ETMY','PRM','SRM','LO1','LO2',
 OSEMS.txt 
  16866   Thu May 19 19:05:59 2022 AnchalUpdateBHDBS Chamber all work finished, BHD path setup[Anchal, Paco, Yuta]

BS Oplev Path


The
changed position of PRM (40m/16863)
  
  16867   Fri May 20 12:42:23 2022 TegaUpdateVACDoor installation on the end stations[JC, Tega, Chub]

Today we installed the 200 lbs
doors on the end station chambers.
  
  16868   Fri May 20 20:03:48 2022 PacoUpdateBHDITMY chamber work finished - LO and AS overlapped[Paco, Anchal, Yuta]

Today, in short we:


Recovered alignment of
 Screenshot_2022-05-20_20-38-25.pngOSEMs.txt 
  16869   Mon May 23 13:16:59 2022 PacoUpdateBHDEnd of vent - checks[Paco, Yuta]

Prep for closing and pump down.


Aligned IFO to maximize
 OSEMs20220523.txtScreenshot_2022-05-23_13-24-06_IFOaligned_GTRY_still_clipping_but_less.pngPR3position.JPG 