  8575   Tue May 14 20:30:29 2013 JamieSummaryIOOMC error spectrum at various FSS gain settings.

I used the Agilent 4395A and the GPIB network bridge to measure the MC error spectrum at the MC servo board.

I looked at various settings of the FSS Common and FAST gains.

Here is the spectrum of various Common gain settings, with a fixed FAST setting of 23.5:

f23.5.pdf

The peak at 34k is smallest at the largest Common gain setting of 13.0 (probably expected).  The other higher frequency peaks are higher, though, such as the ones at 24.7k, 29.6k, 34.5k, etc.:

f23.5z1.pdf

Here's a blow up of the peak at 1.06M, which peaks at about 9dB of common gain:

f23.5z2.pdf

 Here's the spectrum with a fixed Common gain of 10.5, and various FAST gains:

c10.5.pdf

and here's a zoom around that 1.06 MHz peak, which is smallest at a FAST gain of 23.5 dB:

c10.5z1.pdf

I'm not sure yet what this points to as the best gain settings.  We can of course explore more of the space.  I'm going to leave it at 13/23.5, which leaves the PC RMS at ~1.5 and the FAST Monitor at ~6.0.

If this does turn out to be a good setting we'll need to adjust some of the alarm levels.

Various settings:

MCS
  in1 gain: 15
  offset: 1.174
  boost enabled
  super boost: 2
  VCO gain: 25

FSS:
  input offset: -0.8537
  slow actuator: 0.6304

I include the python scripts I used to remotely control the AG4395 to take the measurements, and make the plots.

PS: I made some changes/improvements to the netgpib stuff that I'll cleanup and commit tomorrow.

 

Attachment 6: getdata
#!/usr/bin/env python

import os
import sys
import time
import numpy as np
sys.path.append('/opt/rtcds/caltech/c1/scripts/pylibs/')
import pyezcalib as ca
sys.path.append('/opt/rtcds/caltech/c1/scripts/general/netgpibdata/')
import netgpib
... 64 more lines ...
Attachment 7: plot
#!/usr/bin/env python

import os
#import numpy as np
from pylab import *

#name = sys.argv[1]

#atten = 10 # 10dB

... 31 more lines ...
  8587   Thu May 16 01:41:31 2013 JenneSummaryIOOFSS gain settings set

Quote:

I'm not sure yet what this points to as the best gain settings.  We can of course explore more of the space.  I'm going to leave it at 13/23.5, which leaves the PC RMS at ~1.5 and the FAST Monitor at ~6.0.

 I changed the value of the nominal FSS common gain in the PSL Settings screen (It's called the 'FSS global gain' there).  To get to this screen:  sitemap -> PSL_main -> PSL_settings.  The MC autolocker reads these settings from the screen and uses those values.  Now the FSS returns to this value of 13 that Jamie has chosen.  For the past few days, it's been going back to the old value of 10.1 .  The FAST gain was already set to this 23.5 value.

  8627   Thu May 23 10:48:42 2013 ManasaUpdateIOOMC autolocker and MCWFS enabled

Some strong seismic noise (not related to any earthquakes - watchdogs are all green) had got the MC unlocked this morning.

I found the MC autolocker and MCWFS disabled. Enabling them locked the MC right away. I don't see any updates in the elog  as to why these were left disabled and hence have left them ON now.

  8647   Tue May 28 11:11:37 2013 ManasaUpdateIOOMC aligned

[Jenne, Manasa]

Fixed crappy alignment of MC by moving MC mirrors. MC REFL PD measured 0.5 after alignment. Spot positions were measured using msassMCdecenter. Plot for the same is attached.

Attachment 1: MC_0528.png
MC_0528.png
  8673   Tue Jun 4 20:19:07 2013 ranaConfigurationIOOChanged threshold for FSS SLOW loop

The FSS SLOW actuator often runs off away from zero and into a region where the mode hopping is bad and makes a lot of frequency noise (e.g. that 8 hour period a few weeks ago when Jamie couldn't lock the MC).

It should not have this behavior. The SLOW loop should only be running when the MC is locked.

Today I found that the threshold was set back to 0.2 V (which is approximately the correct value for the RefCav locking). Its being compared to the MC TRANS, so the correct value should be ~1/2 of the maximum MC TRANS.

To find this out, I read this piece of text:

    # Make sure the loop is supposed to be active
    if (get_value("C1:IOO-MC_TRANS_SUM") < get_value("C1:PSL-FSS_LOCKEDLEVEL")) {
    print("Reference Cavity not locked -- control loop disabled.\n");
    next;
    }

from scripts/PSL/FSS/FSSSlowServo. I set the threshold using the commmand:

caput -c -t C1:PSL-FSS_LOCKEDLEVEL 12000

Then I restarted the code on op340m, by typing:

> nohup FSSSlowServo

and then closing the terminal. Seems to be behaving correctly now. Previously, the value was so low that the SLOW loop was never turning itself off.

  8718   Tue Jun 18 18:24:07 2013 ManasaUpdateIOOMC WFS turned OFF

[Jenne, Jamie, Manasa]

Jamie was working on the MC guardian today (I think he will elog about this soon).

After this, I received the MC locked in TEM00 with MC_REFL at ~2.5 counts from Jamie. Usually the WFS would do their job in this case to bring MC to a good locking condition and since this did not happen, I figured out that something was wrong with the MC_WFS.

What we did:

1. The WFS were turned off. 

2. As a first step, we wanted to run the WFS_OFFSET script (Koji's elog) which requires MC to be locked with MC_REFL<0.5 and spot positions centered. The autolocker was disabled and MC locked manually to MC_REFL<0.5. 

3. While running the WFS_OFFSETS script, Jamie pointed out that the inputs to the WFS servo had been turned off. After the WFS_OFFSET script finished running we turned ON the WFS inputs. 

4. Following this, the MC was relocked manually and MC spot positions were measured (all spot positions were decentered by < 2 mm). 

5. We ran the WFS_OFFSET script again and turned the WFS back ON. But this would still kick the MC out of lock. 
 

Status: MC is locked with WFS turned OFF. Jamie will be looking through what changes he had made earlier today to fix this problem. 

 

  8724   Wed Jun 19 15:07:20 2013 ranaUpdateIOOWFS debugging

Trying to figure out what's wrong with the MC WFS:

1) The symptom seems to be that the control signals become very large in the pitch and then the loop breaks when they saturate. Usually this is due to a degenerate matrix or improper inversion. Most likely some of the BURT restore is bad or the analog gain for one of the WFS has been switched when Jamie was doing the "Guardian" debugging.

2) In checking this out, I found that several buttons on the WFS  screens were not working (and apparently have never been working). Please try to test things in the future...The filter bank buttons in C1IOO_MC_TRANS_QPD were using relative path names; fixed these to use abs path names. The buttons in the WFS_MASTER for the IOO_PIT banks were using IOO_PITCH instead...

2.5) Recentered beams on WFS heads with MC alignment good and MC unlocked.

3) Main problem in the WFS still not found - disabling this in the autolocker.

  8733   Thu Jun 20 15:15:39 2013 ranaUpdateIOOWFS debugging

Tried a bunch of stuff, but eventually just turned off the TRANS_QPD loops and loops are stable. Needs more debugging.

  1. Modified the on/off scripts so that the Integrators are no longer toggled. No reason to turn them off since we are clearing the filter bank histories.
  2. With QPD feedback OFF, I have lowered the overall gain by 15x so that its just drift control.
  3. Deleted unused / bad filters from the main filter banks.
  4. Gautam is going to debug the QPD with a red laser pointer and then elog.
  5. Jamie is checking out the MC Coil dewhitening logic to see if that's in a funny state.
Attachment 1: Untitled.png
Untitled.png
  8735   Thu Jun 20 20:46:16 2013 gautamUpdateIOOWFS debugging-QPD debugging

 

 I wanted to make sure that the QPD map on the C1IOO_MC_TRANS_QPD.adl screen corresponded to the actual physical quadrants on the photodiode at the MC2 table. We turned MC_WFS_OUT  OFF before fiddling around with a red laser pointer to try and map the quadrants.

I initially verified the correspondence between the various quadrants and the text-fields displaying the outputs using PV_Info. I found that there was good agreement in this respect. So for instance, field adjacent to the quadrant marked "1" on the C1IOO_MC_TRANS_QPD.adl screen had the following input channel: IOO_MC_TRANS_SEG1_INMON. The filter banks were empty and there was just an overall gain on -1 on all four channels. The channels leading to the filter-banks were the 'right' ones: quadrant 1 for the top bank, then quadrants 2,3 and 4 down.

Next, a red laser pointer was used to map the quadrants. Here, there was some disagreement between the physical quadrants and the map on the C1IOO_MC_TRANS_QPD.adl screen, which is summarised in the attached image-the whole thing is sort of rotated 180degrees about the centre. 

The interpretation of the figure is as follows:

quadrant 1 on screen QPD=bottom right quadrant on QPD

quadrant 2 on screen QPD=top right quadrant on QPD

quadrant 3 on screen QPD=top leftt quadrant on QPD

quadrant 4 on screen QPD=bottom left quadrant on QPD

MC_WFS_OUT was turned back ON.

 

 

 MC2_QPD-map.png

 

 

  8756   Wed Jun 26 13:37:13 2013 JenneUpdateIOOMC very misaligned - put back

Not sure why it was so poorly aligned, since the misalignment "event" happened while we were all away at lunch, but I steered the MC optics until their SUSYAW and SUSPIT values were about the same as they were before they got misaligned.  MC autolocker took over, and things are back to normal.

  8794   Wed Jul 3 10:39:25 2013 manasaUpdateIOOMC aligned and WFS enabled

I found WFS had been left disabled from sometime yesterday. I don't see anyone mentioning  when and why they had turned OFF the WFS servo.

I aligned MC and turned ON the WFS servo. MC is back.

  8815   Tue Jul 9 20:09:53 2013 KojiUpdateIOOWFS debugging

The low UGFs of the MC WFS servos made the MC insane thesedays:
The servos are too slow and we kept having significant misalignment left uncompensated.

I increased the total gain of the MC WFS from 0.01 to 0.4 (x40) to make the UGFs of the
WFS paths to ~2Hz. This was too much gain for the QPD path so the gains for the QPD paths
were reduced by a factor of 4 (x10 in total).

The script mcwfsup was also modified accordingly.

  8843   Sun Jul 14 17:47:28 2013 KojiUpdateIOOMC WFS maintenance

Annalisa notified me that the MC autolocker could not keep the MC locked.

I found the initial alignment was not good and the MC was too much excited when the WFS kicked in.

There might have been the WFS offset issue due to the miscentering of the spots on the WFS diodes.

I used the usual procedure of the maintenance and it looked OK if I followed the switching procedure the mc autolocker suppoed to do.
http://nodus.ligo.caltech.edu:8080/40m/7452

I still could not get the autolocker running smoothly. I opened mcup script and compared what was the difference
between my manual sequence and what the script did. The only difference was the lines related to MCL.
It was still turning on the filter module. I checked the MCL path and found that the gain was not zero but 1.0.
So now the MCL gain is set to zero. This solved all the remaining issue.

  8906   Tue Jul 23 13:55:08 2013 KojiUpdateIOOMC manually aligned

The MC was manually aligned. The spot positions were measured and it is consistent with the measurements done yesterday.

Attachment 1: MCalignment.png
MCalignment.png
Attachment 2: MCspot.png
MCspot.png
  8913   Tue Jul 23 21:32:43 2013 KojiUpdateIOOFound the cause of mysterious MC motion

Thesedays we were continuously annoyed by unELOGGED activities of the interferometer.

MC2 LOCKIN was left on and has continuously injected frequency noise and beam pointing modulation
during all of the comissioning / vent preparation.

C1:SUS-MC2_LOCKIN2_OSC_FREQ was 0.075
C1:SUS-MC2_LOCKIN2_OSC_CLKGAIN was 99

For more than a week ago we noticed that the curve of the MC WFS stripchart suddenly got THICKER.
MC WFS, arm transmission, beam pointing... everything was modulated.
It was not WFS instability, and it was not the cavity mirrors.

Today I made the investigation and finally tracked down the cause of this issue to be on MC2 suspension.
Then it was found that this LOCKIN was ON.

There is no direct record of this lockin in the frame files.
From the recorded channel "C1:IOO-WFS2-YAW_OUT16" (which is the trace on the StripTool chart on the wall)
It was turned on at July 10th, 2:00UTC (July 9th, 7PM PDT)

  8917   Wed Jul 24 14:26:24 2013 ranaUpdateIOOFound the cause of mysterious MC motion

Yes, this was not ELOG'd by me, unfortunately. This was the MC tickler which I described to some people in the control room when I turned it on.

As Koji points out, with the MCL path turned off this injects frequency noise and pointing fluctuations into the MC. With the MCL path back on it would have very small effect. After the pumpdown we can turn it back on and have it disabled after lock is acquired. Unfortunately, our LOCKIN modules don't have a ramp available for the excitation and so this will produce some transients (or perhaps we can ezcastep it for now). Eventually, we will modify this CDS part so that we can ramp the sine wave.

  9030   Mon Aug 19 11:30:20 2013 JenneUpdateIOOMC mirrors' ASC has non-zero inputs

[Masayuki, Jenne]

When I came in this morning, I noticed that the Mode Cleaner had not been locked for at least the past 8 hours.  We moved the MC SUS sliders until the MC SUSPIT and SUSYAW values for each mirror were back to approximately the place they were the last time the MC was nicely locked (~12 hours ago).  This got the MC flashing TEM00, so we thought we were doing well. 

However, if the servo was enabled, any time the cavity flashed a small-order mode (especially 00), the mirrors would get super kicked.  Not good

We went to investigate, and discovered that the RFPD aux laser was left on again.  We turned that off, however that didn't fix the situation. 

Manasa suggested checking that the WFS were really, really off.  When we looked at the WFS master screen, we noticed that although the WFS servos were off, the MC mirrors' ASC filter banks had non-zero inputs.  We checked, and this is not from the MCASS, nor is it from the MC WFS lockins.  At this point, I have no idea where these signals are coming from.  I have turned off the ASC outputs for all the MC mirrors (which means that we cannot turn on the WFS), and the MC locks fine

So, we need to know where the ASC signals are coming from.  There isn't anything that I can see, from any screen that I can find, that indicates some signals being sent over there.  Has anyone done anything lately?  I know Koji was working on IPC stuff the other day, but the MC was locking fine over the weekend until yesterday afternoon, so I suspect that's not the culprit. 

I have turned off the outputs of the WFS lockins, as part of my turning things off, so if whatever script needs them doesn't enable them, they should be turned back on by hand.

  9032   Mon Aug 19 15:23:07 2013 KojiUpdateIOOMC mirrors' ASC has non-zero inputs

[Jenne, Koji]

This disturbance in the MC ASC channels were fixed.

This craziness happened ~10pm last night. Was there any action at the time? >> Sunday-night workers? (RXA: No, Nakano-kun and I left before 9:30 PM)

We found that the signals came from c1ioo. However, restarting, recompiling c1ioo and c1mcs didn't help
to clean up this issue. Just in case we cleaned up the corresponding entries in the ipc file /opt/rtcds/caltech/c1/chans/ipc/C1.ipc
and recomplied c1ioo and c1mcs because these are the channels we touched last week to mitigate the timing out issue of c1rfm.

Incidentally, we fell into a strange mode of the RCG: IOPs could not restart. We ended up running "sudo shutdown -r now"
on each machine (except for c1lsc which was not affected by this issue). This solved the issue.

Even now c1oaf could not be running properly. This is not affecting the IFO operation right now, but we need to look into this issue again
in order to utilize OAF.

  9046   Wed Aug 21 19:26:19 2013 ranaUpdateIOOFound the cause of mysterious MC motion

Quote:

Yes, this was not ELOG'd by me, unfortunately. This was the MC tickler which I described to some people in the control room when I turned it on.

As Koji points out, with the MCL path turned off this injects frequency noise and pointing fluctuations into the MC. With the MCL path back on it would have very small effect. After the pumpdown we can turn it back on and have it disabled after lock is acquired. Unfortunately, our LOCKIN modules don't have a ramp available for the excitation and so this will produce some transients (or perhaps we can ezcastep it for now). Eventually, we will modify this CDS part so that we can ramp the sine wave.

 I've written a new TICKLE script using the newly found 'cavget' and 'cavput' programs. They are in the standard epics distribution as extension binaries. They allow multichannel read/write as well as ramping, delays, incremental steps, etc. http://www.aps.anl.gov/epics/tech-talk/2012/msg01465.php.

Running from the command line, they seem to work fine, but I've left it OFF for now. I'll switch it into the MC autolocker at some point soon.

  9148   Fri Sep 20 20:27:18 2013 ranaUpdateIOOmode cleaner not locking

 I used our procedure from this entry to set the IMC board offset as well as the FSS board offset.

I found this afternoon that the MC was having trouble locking: the PC path was railing as soon as the boost was engaged. Could be that there's some misalignment on the PSL which has led to some RAM having to be canceled by this new offset. Let's see if its stable for awhile.

  9153   Sun Sep 22 22:54:28 2013 ranaUpdateIOOmode cleaner not locking

Having trouble again, starting around 1 hour ago. No one in the VEA. Adjusted the offset -seems to be OK again.

  9175   Mon Sep 30 13:02:51 2013 Masayuki,ManasaUpdateIOOPMC and MC alignment

[Manasa, Masayuki]

The MC lost lock around 8+hrs ago. The transmission from PMC was 0.77 this morning, so we aligned the PSL to the PMC using the two steering mirrors before the PMC. We brought the PMC transmission to 0.841. We also aligned the MC, and the MC transmission reflection now is 0.59.

  9190   Thu Oct 3 01:24:31 2013 Jenne, RanaUpdateIOOPMC

The PMC transmission was around 0.78 all day, rather than the usual 0.83ish.  Rana went out to the PSL table and fixed up the PMC alignment.  This should not need to be done very often, so things to check before touching the alignment are FSS / PMC settings (digital stuff).  Make sure that the PC RMS (on the FSS screen) is low (at least below 2, preferably below 1), and that the FSS Fast monitor is near 5ish (not near 0 or 10).  

This is a capture of PMC REFL's camera after Rana was finished. If it doesn't look this good when you finish then you are not done. Never do PMC alignment without looking at the PMC REFL camera.

PMCR_1064822387.bmp

The attached trend shows 80 days of PMC REFL and TRANS. The bad alignment stuff started on Sep 21-24 time period. You know who you are.

Attachment 2: pmc80.png
pmc80.png
  9205   Sun Oct 6 17:05:49 2013 ranaSummaryIOOMC ASC problems

MC unlocked over the weekend and also got severely mis-aligned. It all started around midnight on Saturday.

At first I thought that this was due to the MCS CPU meter being railed at 60 us, so I deleted a bunch of filters in MC1,2,3 that are unused and left over from Den's quantization noise investigations. This reduced the CPU load somewhat, but didn't make any real improvements. Turning on the ASC filter banks in the MC SUS still mis-aligned the MC.

With the MC WFS and MC ASS turned off, there is still some digital junk coming in and misaligning things. Plot attached.

Similar stuff coming in on ITMX, but not ITMY.

Tried restarting various FEs, but there was no effect. Also tried rebooting c1lsc, c1ioo, & c1sus. Finally did 'shutdown -r now' on all 5 computers on the CDS overview screen and simultaneously (almost) pressed the reset button on the RFM switch above the old c1pem crate. Everything came back OK except for c1oaf (I had to manually button his BURT button) and now the ASC inputs on all the SUS are zero when they should be and MC is well locked and aligned.

Rob and I used to do this trick when he thought that a cosmic ray had corrupted a bit in the RFM network.

Attachment 1: mcasc.pdf
mcasc.pdf
  9209   Sun Oct 6 22:52:09 2013 Jenne, RanaUpdateIOOinput beam to PMC aligned again

pmcr.pngafter

I wonder what's drifting between the laser and the PMC? And why is it getting worse lately?

  9210   Sun Oct 6 23:43:07 2013 ranaUpdateIOOWFS debugging

Quote:

Tried a bunch of stuff, but eventually just turned off the TRANS_QPD loops and loops are stable. Needs more debugging.

  1. Modified the on/off scripts so that the Integrators are no longer toggled. No reason to turn them off since we are clearing the filter bank histories.
  2. With QPD feedback OFF, I have lowered the overall gain by 15x so that its just drift control.
  3. Deleted unused / bad filters from the main filter banks.
  4. Gautam is going to debug the QPD with a red laser pointer and then elog.
  5. Jamie is checking out the MC Coil dewhitening logic to see if that's in a funny state.

 Back around June 18, Jamie was debugging some Guardian code here to replace our MC autolocker. Afterwards our MC WFS stopped working. We never figured out what went wrong, but at the time we turned off the feedback from the MC trans QPD and it stabilized the response at DC.

Today, I noticed that the trans QPD feedback is on.  Did anyone do this on purpose?

Its problem causing behavior is slow, but you can catch it if you wait. With the nominal WFS gain of 0.4 the control signal ramps up monotonically at a rate of ~100 counts/minute. Depending upon the static alignment of the MC, this could let it take 10 minutes or a few hours before it rails the MC SUS actuators and breaks the lock. Very sneaky. Don't turn this loop back on without making sure its working and not breaking. I would trend it for you, but the SLOW channels associated with the TRANS QPD servo are not trended --- does anyone know how to get them in the channel list?

  9238   Mon Oct 14 17:51:40 2013 JenneUpdateIOOinput beam to PMC drifted again

Quote:

I wonder what's drifting between the laser and the PMC? And why is it getting worse lately?

 The PMC refl is bad in pitch today, and the transmission is only 0.76, rather than our usual 0.83ish.

I did a quick, rough tweak-up of the alignment, and now we're at 0.825 in transmission.

  9256   Mon Oct 21 13:15:52 2013 KojiUpdateIOOPMC aligned

PMC aligned. Trans 0.78 -> 0.83

  9296   Sat Oct 26 21:46:33 2013 RANAUpdateIOOMode Cleaner Tune-UP

 The MC had been unlocked for the last 4 hours and was crying out to me so I gave it some attention. Its happier now.

From the trend (AtM #1), I saw that the MC2 suspension has moved by ~10 microradians. Since the MC cavity divergence angle is lambda/(pi*w0) ~ 200 microradians, this isn't so much, but enough to cause it to lock on bad modes sometimes. Attackmint too shows that there's not much in monotonic drift over the last 40 nights.

I moved back MC2 to its old alignment with these commands:

ezcaservo -r C1:SUS-MC2_SUSPIT_INMON -s -1017 -g 0.0009 C1:SUS-MC2_PIT_COMM -t 300

ezcaservo -r C1:SUS-MC2_SUSYAW_INMON -s 490 -g 0.0009 C1:SUS-MC2_YAW_COMM -t 332

Then I went out to the table and aligned the beam into MC using the last two steering mirrors good enough so that the WFS coming on doesn't make the visibility any better. In this nominal state, I unlocked the MC and then aligned the reflected beam onto the center of the LSC PD as well as the WFS. The beam on the first WFS is a little small - next time someone wants to improve our Gouy phase telescope, we might try to make it bigger there. On the LSC PD, the beam was off-center by a few hundred microns.

Attachment 1: MCtrend.pdf
MCtrend.pdf
Attachment 2: MC40days.png
MC40days.png
  9303   Mon Oct 28 14:12:48 2013 manasaUpdateIOOMode Cleaner relocked

Quote:

 The MC had been unlocked for the last 4 hours and was crying out to me so I gave it some attention. Its happier now.

From the trend (AtM #1), I saw that the MC2 suspension has moved by ~10 microradians. Since the MC cavity divergence angle is lambda/(pi*w0) ~ 200 microradians, this isn't so much, but enough to cause it to lock on bad modes sometimes. Attackmint too shows that there's not much in monotonic drift over the last 40 nights.

I moved back MC2 to its old alignment with these commands:

ezcaservo -r C1:SUS-MC2_SUSPIT_INMON -s -1017 -g 0.0009 C1:SUS-MC2_PIT_COMM -t 300

ezcaservo -r C1:SUS-MC2_SUSYAW_INMON -s 490 -g 0.0009 C1:SUS-MC2_YAW_COMM -t 332

Then I went out to the table and aligned the beam into MC using the last two steering mirrors good enough so that the WFS coming on doesn't make the visibility any better. In this nominal state, I unlocked the MC and then aligned the reflected beam onto the center of the LSC PD as well as the WFS. The beam on the first WFS is a little small - next time someone wants to improve our Gouy phase telescope, we might try to make it bigger there. On the LSC PD, the beam was off-center by a few hundred microns.

Masayuki was running LAN cables near the MC2 chamber. This caused the MC2 suspension to move and unlocked the MC. I looked at the long term (2 days) and short term (2 hours) trend of the MC suspensions. I restored the old alignment as described above using ezcaservo.

C1:SUS-MC2_SUSPIT_INMON was restored to 1020 and C1:SUS-MC2_SUSYAW_INMON was restored to 490.

Attachment: Dataviewer trend (2 hours)

Attachment 1: Screenshot-Untitled_Window-3.png
Screenshot-Untitled_Window-3.png
  9306   Mon Oct 28 21:33:55 2013 RANAUpdateIOOMode Cleaner Tune-UP

 

8 day minute trend of some of the IMC alignment signals.

That step ~2 days ago in the WFS2 yaw control signal shows that I didn't do such a good job on yaw.

Nic is going to come over some time and give us a new Gouy telescope that let's us have bigger beams on the WFS. At LLO, Hartmut demonstrated recently how bigger beams can reduce offsets somehow...mechanism TBD.

Also, we must angle the WFS and figure out how to dump the reflections at the same time that we rework the table for the telescope.

Steve, can you please put 2 mounted  razor dumps near the WFS for this purpose??    

            Tuesday: Razor dumps are waiting for you.

 

Attachment 1: Untitled.png
Untitled.png
  9315   Wed Oct 30 01:53:52 2013 JenneUpdateIOOMode Cleaner relocked

The MC (mostly MC2) decided a few minutes ago to move, so I put the SUSPIT and SUSYAW numbers back where they were, and the tweaked up the alignment from there to get a low MC REFL DC number.  Now the MC is staying locked again, after 20 minutes of not.

  9320   Wed Oct 30 16:46:17 2013 manasaUpdateIOOMC aligned

MC has not been very happy since last night. 

What I did to fix this:

1. Disabled autolocker and WFS and aligned the MC to bring MC REFL down to <0.50

2. When I re-enabled autolocker, MC was losing lock everytime WFS turned ON.

3. I relocked MC, measured the spot positions and moved MC spot positions by running /opt/rtcds/caltech/c1/scripts/ASS/MC/mcassMCdecenter 
and 
/opt/rtcds/caltech/c1/scripts/MC/moveMC2/

4. I reset the WFS offsets by running /opt/rtcds/caltech/c1/scripts/MC/WFS/WFS_FilterBank_offsets

5. MC is locked and looks happy right now with REFL DCMON at ~0.5

 

  9322   Thu Oct 31 15:34:28 2013 manasaUpdateIOOMC not happy since yesterday

Quote:

 

8 day minute trend of some of the IMC alignment signals.

That step ~2 days ago in the WFS2 yaw control signal shows that I didn't do such a good job on yaw.

Nic is going to come over some time and give us a new Gouy telescope that let's us have bigger beams on the WFS. At LLO, Hartmut demonstrated recently how bigger beams can reduce offsets somehow...mechanism TBD.

Also, we must angle the WFS and figure out how to dump the reflections at the same time that we rework the table for the telescope.

Steve, can you please put 2 mounted  razor dumps near the WFS for this purpose??    

            Tuesday: Razor dumps are waiting for you.

 

The MC has not been able to hold lock for over a couple of hours since yesterday. I aligned the MC yesterday (elog 9320) and it lost lock in a couple of hours. I realigned the MC again around noon today only to see it drifting and lose lock again.

I have attached the MC trend for the 2 hours when the MC drifted slowly from its happy to sad state.

 

 

Attachment 1: MC_drift.png
MC_drift.png
  9323   Thu Oct 31 20:05:48 2013 RANAUpdateIOOMode Cleaner Tune-UP

Quote:

Steve, can you please put 2 mounted  razor dumps near the WFS for this purpose??    

            Tuesday: Razor dumps are waiting for you.

 I couldn't find any dumps near the WFS. Koji looked. I looked twice. Maybe they are spooky and absorbing all of the light?

The MC alignment was bad and the WFS were making it drift. Koji aligned the beam into the PMC. I then restored the MC suspensions to where they were 8 days ago (back when the transmission and reflection were good). With the WFS OFF, this gave us a MC trans ~ 16000. With WFS ON it goes to 17500 which is about as good as its been over the last 80 days.

I centered the beam on the WFS with the MC unlocked and also centered the beam on the whole WFS path (it was near clipping between WFS 1 & 2). Also for some reason that beamsplitter which steers the beam onto WFS1 is a R=33% (!? why is this not a R=50% ??).

Steve, please swap this out to a BS1-1064-50-1025-45S if we have one sitting around. If not, we want to add this to the CVI purchase list, but not buy until we get a bigger list together.

I also centered this newly aligned beam into the IMC onto the PSL QPDs. We should now use these as a pointing reference for the beam into the IMC.

While doing this I noticed that the beam was almost clipping on the Uniblitz shutter used to block the PSL beam. That shutter is mounted too short and was also not centered horizontally. I removed it for now so that Steve can find a more adjustable mount for it and put it back into play. The beam going into the IMC is BIG, so you have to very careful when centering the shutter. Might be that we cannot leave it at 45 deg and still get a big enough aperture.

Note #3 for Steve: please also replace the mount for last steering mirror into the IMC with a Polanski or a Superman, that black Ultima is no good. Also the dogs must be steel - no aluminum dogs for our sensitive places.

Attachment 1: drifty.png
drifty.png
  9324   Thu Oct 31 21:22:00 2013 rana, kojiSummaryIOOmodulation beat note in MC servo

I hooked up the 4395 to the MC servo board test out (TP2A) and looked at the spectrum using our new SPAG4395.py script. We noticed a huge peak at ~3.8 MHz and correctly guessed that it was due to the beat between the MC modulation frequency 29.5 MHz and 3*f1 (~33 MHz).

So we tuned the Marconi for the main mod. from 11065910 to 11066099 Hz and saw the beat note disappear (to within the 1 Hz tuning precision of our Marconi).

New MC length tuning method! Alert the LA Times!

13031.png13031_200.png13031_200b.png

My conjecture is that this temperature dependent mismatch between the modulation frequency (f1) and the MC length  is what leads sometimes to our nasty saturating PC DRIVE signal. TBD.

  9325   Fri Nov 1 09:45:32 2013 SteveUpdateIOObeam dumps to be find

Quote:

Quote:

Steve, can you please put 2 mounted  razor dumps near the WFS for this purpose??    

            Tuesday: Razor dumps are waiting for you.

 I couldn't find any dumps near the WFS. Koji looked. I looked twice. Maybe they are spooky and absorbing all of the light?

The MC alignment was bad and the WFS were making it drift. Koji aligned the beam into the PMC. I then restored the MC suspensions to where they were 8 days ago (back when the transmission and reflection were good). With the WFS OFF, this gave us a MC trans ~ 16000. With WFS ON it goes to 17500 which is about as good as its been over the last 80 days.

I centered the beam on the WFS with the MC unlocked and also centered the beam on the whole WFS path (it was near clipping between WFS 1 & 2). Also for some reason that beamsplitter which steers the beam onto WFS1 is a R=33% (!? why is this not a R=50% ??).

Steve, please swap this out to a BS1-1064-50-1025-45S if we have one sitting around. If not, we want to add this to the CVI purchase list, but not buy until we get a bigger list together.

I also centered this newly aligned beam into the IMC onto the PSL QPDs. We should now use these as a pointing reference for the beam into the IMC.

While doing this I noticed that the beam was almost clipping on the Uniblitz shutter used to block the PSL beam. That shutter is mounted too short and was also not centered horizontally. I removed it for now so that Steve can find a more adjustable mount for it and put it back into play. The beam going into the IMC is BIG, so you have to very careful when centering the shutter. Might be that we cannot leave it at 45 deg and still get a big enough aperture.

Note #3 for Steve: please also replace the mount for last steering mirror into the IMC with a Polanski or a Superman, that black Ultima is no good. Also the dogs must be steel - no aluminum dogs for our sensitive places.

No wonder they could not find the beam dumps. Last night was Haloween. They should of just said: Trick or treat! where are the beam dumps?

Attachment 1: razor_beam_dumps.jpg
razor_beam_dumps.jpg
  9334   Mon Nov 4 11:37:12 2013 SteveUpdateIOOPSL output shutter installed

 

 The PSL shutter is reinstalled.The base plate is delrin for isolation and the mount height is adjustable. The last steering mirror mount to be swapped in is ready. It is sitting on the top of the ITMX optical table cover with SS dogs.

There are two reflected spots on the north side of the Uniblitz shutter. They are coming from the vacuum window. They should be trapped also.

Attachment 1: Shutterisback.jpg
Shutterisback.jpg
  9336   Mon Nov 4 12:59:43 2013 JenneUpdateIOOMC alignment not so good after PSL output shutter installed

Quote:

  The PSL shutter is reinstalled.

 I'm not sure if Steve bumped something, or if it was just a fluke, but the MC didn't come back very nicely after Steve finished re-installing the shutter.

Earlier today, after Steve locked the PMC, MC trans looked good for over an hour (according to the striptool plot on the wall).  Then, the MC was unlocked for about an hour, presumably while Steve was working, he had the light blocked.  When he finished, the MC transmission was around 5,000 while usually it is around 17,000.  The reflection was around 3.4, rather than a best of below 0.5 (unlocked refl is 4.5).

Using Rana's ezcaservo trick to get the suspensions back to where they were at last good lock usually works (I used to do it by hand though).  However, today, it only got the reflection down to about 2.0.  So, I did the rest of the alignment by hand. 

After I did this, the reflection is down to 0.48.  Engaging the WFS makes the MC much more noisy, so I have them disabled currently. 

I have measured the spots, and if I compare them to the measurements that (I think it was Manasa) took last week, they look pretty bad. 

I think that we need to swap out the 2nd zigzag mirror, and then do a careful MC realignment.  It's certainly not worth doing the work, and then re-doing it after we swap out the zigzag mirror.

MCspots_4Nov2013.png

  9342   Tue Nov 5 00:39:43 2013 manasaUpdateIOOIFO alignment tuning

Information acknowledged from Steve:

The last steering mirror mount for IR on the PSL was swapped for a more robust one. Prior to swapping the ibeam positions on the PSL IOO QPDS in ang and pos were recorded.

What I did henceforth:

1. Once the last steering mirror was installed, I walked the beam to restore input pointing using the last 2 steering mirrors. It needed a lot of work in yaw as expected.

2. When the input pointing was recovered, MC locked right away in TEM00. I measured the MC spot positions and compared it with Jenne's measurement made prior to the swap. The spot positions were pretty close.

3. The input pointing was adjusted in pitch and yaw (on the last steering mirror) in small steps. MC alignment was recovered and spot positions were measured each time. After several iterations, the MC spot positions were pretty much centered. I recentered the WFS and reset the WFS offsets. MC is now locked with WFS enabled at ~16900 counts.

MC_spot.png

4. Since the arms were aligned this morning, I used the Y arm as reference and corrected for the input pointing using tip-tilts.

5. Arms locked right away. Note: ASS doesn't seem to be doing it's job. I had to manually align the arms for maximum on TRX and TRY.

6. MICH and PRMI lock were also recovered.

7. I started to check the status with ALS as well. But for reasons unknown, I don't see any ADC counts corresponding to the beat note. Looking at the beatbox there aren't any signs of disconnected cables.  I am saving this as a morning job to fix it.

  9343   Tue Nov 5 08:44:21 2013 SteveUpdateIOOafter last steering mirror mount swap

 The IOO Angle and IOO Position qpds  were recentered after this entry.

 Suggested corrections in elog entry #9323 are completed:

 1,  last steering mirror mount replaced by Polanski mount

 2,  PSL output shutter mount reconfigured

 IOO qpds are not centered. I failed to connect laptops to 40MARSian network.

Attachment 1: after_Shutter_SMm_installed.png
after_Shutter_SMm_installed.png
Attachment 2: afterlastSMmountswap.jpg
afterlastSMmountswap.jpg
  9352   Wed Nov 6 08:33:53 2013 SteveUpdateIOOPoiting changes of PSL

Quote:

 Full list tomorrow: IP-Ang & Pos, ETMY-T, ETMY-Oplev, ETMX-T, IOO-Ang & Pos

 RA: No one in the control room this evening can understand what this ELOG means. Please use more words.

 Yesterday the last steering mirror mount on the PSL was changed, Manasa recovered the MC alignment and Jenne locked the arms.

 I centered the following qpds:  ASC-IBQPD, LSC-TRY, SUS-ETMY_OPLEV, LSC-TRX, SUS_ETMX_OPLEV

 Touching the PSL pointing IOO-QPD_ANG & POS was a mistake. We lost the reference of the well refined MC input.

 

One and 20 days TRENDS  plot showing the PSL output drift in pitch can be power drop

However initial pointing is amazingly good. ( I wonder about the lens in front of the qpd ?)

Attachment 1: 1dayTRENDofPOITING.png
1dayTRENDofPOITING.png
Attachment 2: 20dayTRENDioo.png
20dayTRENDioo.png
  9358   Thu Nov 7 08:57:20 2013 SteveUpdateIOOPSL pointing monitoring

 The qpd sees the power drop as position change.

The laser  monitoring screen shows little changes of the Innolight 2W output. See elog 9292 to compare

So why does the PMC downgrade if the laser output is stationary ?

The PMC-T power is down to 0.75V  The auto locker does maximize power output.

It needs a manual alignment touch up.

 

 

Attachment 1: PMC11072013.jpg
PMC11072013.jpg
Attachment 2: PMCTqpdMon.png
PMCTqpdMon.png
  9365   Mon Nov 11 22:35:45 2013 RANAUpdateIOOPSL pointing monitoring

Since the pointing has gone bad again, I went to the PSL to investigate. Found some bad things and removed them:

1) There was a stopped down iris AGAIN in the main beam path, after the newly installed mirror mount. I opened it. Stop closing irises in the beam path.

2) The beam dump for the IOO QPD reflection was just some black aluminum. That is not a real dump. I removed it. We need two razor blade dumps for this.

3) There was an ND filter wheel (???) after one of the PMC steering mirrors. This is not good noise / optics practice. I removed it and dumped the beam in a real dump. No elog about this ?!#?

 

The attached trend shows the last 20 days. The big step ~2 weeks ago is when Steve replaced the steering mirror mount with the steel one. I don't understand the drift that comes after that.

 

Today I also spent ~1 hour repairing the Aldabella laptop. Whoever moved it from the PSL area to the SP table seems to have corrupted the disk by improper shutdown. Please stop shutting the lid and disconnecting it from the AC power unless you want to be fixing it. Its now running in some recovery mode. Lets leave it where it is next to the PSL and MC1.

I steered the MC suspensions back to where they were on the trends before the PSL mirror mount swap and then aligned the PSL beam into it by touching the last 2 steel mounts. Once the alignment was good without WFS, I centered the beams on the IOO QPDs. If it behaves good overnight, I will center the unlocked beams on the MC WFS.

 

Please stay off the PSL for a couple days if you can so that we can watch the drift. This means no opening the doors, turning on the lights, or heavy work around there.

Attachment 1: qpd.pdf
qpd.pdf
  9370   Tue Nov 12 23:48:23 2013 RANAUpdateIOOPSL pointing monitoring

Since I saw that the trend was good, I aligned the MC refl path to the existing IMC alignment:

  1. removed a broken IRIS that was clipping the reflected beam (and its mount)
  2. moved the first 1" diameter steering mirror on the high power path after the 2" diameter R=10% steering mirror. It was not centered.
  3. Moved the lens just upstream of the LSC RFPD away from the PD by ~5 mm. The beam going towards the WFS was too close to this mount and I could see some glow.
  4. Centered the beam on all optics in the WFS path and then the WFS DC.
  5. Centered beam on LSC RFPD.

The reflected spots from the PD are not hitting the dump correctly. WE need to machine a shorter post to lower the dump by ~1 cm to catch the beams.

  9389   Fri Nov 15 09:24:41 2013 SteveUpdateIOOWFS with beam dumps

This is a proposal to move WFSs such way that their reflected beam can be trapped.

Later ps: Nic will take care of the Gouy phase telescopes.

Attachment 1: MCwfsRefTraped.jpg
MCwfsRefTraped.jpg
  9390   Fri Nov 15 09:27:58 2013 KojiUpdateIOOWFS with beam dumps

Unfortunately this does not work. These WFSs are not the detectors which we can move freely.
In order to move the WFS detectors, we need the precise design of the Gouy phase for each WFS heads.
Without the design, we can't move the detectors.

  9421   Thu Nov 21 16:32:20 2013 SteveUpdateIOOPMC needs a touch of love

 

 The PMC power degrading on this 3 days plot. MC2 -T = 14,200 counts. C1:IOO-MC_TRANS_SUM can not be ploted in dataviewer. The MEDM screen has a valid number.

Initial pointing is not so bad (what does "not so bad" mean ???)

C1iscey comes and goes again.

 

Attachment 1: PMCplus.png
PMCplus.png
  9431   Sat Nov 30 23:50:28 2013 ranaUpdateIOOmode cleaner not locking

Quote:

 I used our procedure from this entry to set the IMC board offset as well as the FSS board offset.

I found this afternoon that the MC was having trouble locking: the PC path was railing as soon as the boost was engaged. Could be that there's some misalignment on the PSL which has led to some RAM having to be canceled by this new offset. Let's see if its stable for awhile.

 I felt in my bones that the MC was in trouble so I came by and noticed that it hadn't locked for a couple hours. The FSS SLOW was at -1.6V, but putting it back to zero didn't fix things. I adjusted the FSS error point offset to +1 and that took the FSS_FAST off of the +10 V rail. Relocked and seems OK.

We need to plan to make the M Evans mod to the FSS box to make the PC drive less angry.

Last 40 days of MC Alignment trends  show that the recent MC WFS tuning / offseting worked out OK. MC REFL seems low and flat.

Attachment 1: mcdrift.png
mcdrift.png
  9448   Fri Dec 6 15:57:41 2013 SteveUpdateIOObeam dumps for PSL pointing monitoring

Quote:

Since the pointing has gone bad again, I went to the PSL to investigate. Found some bad things and removed them:

1) There was a stopped down iris AGAIN in the main beam path, after the newly installed mirror mount. I opened it. Stop closing irises in the beam path.

2) The beam dump for the IOO QPD reflection was just some black aluminum. That is not a real dump. I removed it. We need two razor blade dumps for this.

3) There was an ND filter wheel (???) after one of the PMC steering mirrors. This is not good noise / optics practice. I removed it and dumped the beam in a real dump. No elog about this ?!#?

 

The attached trend shows the last 20 days. The big step ~2 weeks ago is when Steve replaced the steering mirror mount with the steel one. I don't understand the drift that comes after that.

 

Today I also spent ~1 hour repairing the Aldabella laptop. Whoever moved it from the PSL area to the SP table seems to have corrupted the disk by improper shutdown. Please stop shutting the lid and disconnecting it from the AC power unless you want to be fixing it. Its now running in some recovery mode. Lets leave it where it is next to the PSL and MC1.

I steered the MC suspensions back to where they were on the trends before the PSL mirror mount swap and then aligned the PSL beam into it by touching the last 2 steel mounts. Once the alignment was good without WFS, I centered the beams on the IOO QPDs. If it behaves good overnight, I will center the unlocked beams on the MC WFS.

 

Please stay off the PSL for a couple days if you can so that we can watch the drift. This means no opening the doors, turning on the lights, or heavy work around there.

 IOO pointing monitoring qpds received razor beam dumps on their refs.

The Pos QPD was rotated and recentered.

The Ang QPD was left untouched.

TREND plot of 23 days is attached.

Attachment 1: IOO_QPD_MONS.jpg
IOO_QPD_MONS.jpg
Attachment 2: PointingTrend23d.png
PointingTrend23d.png
ELOG V3.1.3-