7546
|
Mon Oct 15 10:14:22 2012 |
Den | Update | PEM | AA board |
Quote: |
I'll leave accelerometers near ETMX table. It's interesting to measure table motion in the morning when trucks drive by.
|
That low frequency effect was due to AA board, now it is gone. |
7562
|
Tue Oct 16 21:57:47 2012 |
Den | Update | PEM | accelerometers |
All accelerometers are now at the table behind 1X4, cables are near readout box. |
7567
|
Wed Oct 17 09:01:37 2012 |
Steve | Update | PEM | ants on the PSL table |
Quote: |
We observed one or two ants climbing over PMC optics without booties and safety glasses.
The floor was mopped with strong Bayer Home Pest Control solution in the Vertex area.
Do not work inside the 40m lab if you are sensitive to chemicals!
|
The floor is mopped again with strong PEST CONTROL SOLUTION in water in the Vertex area.
Do not plane to work in the IFO-room till noon if you are sensitive to chemicals! |
7626
|
Thu Oct 25 21:02:34 2012 |
Den | Update | PEM | 1x7 dc power |
We now stop using bench DC power supplies for microphone preamp and PEM AA board. DC power is wired from 1x5 rack suppliers. I've installed a beam to mount fuse houses in the 1x7 as we did not have one.

|
7645
|
Wed Oct 31 14:31:34 2012 |
Steve | Update | PEM | high particle count |
High particle count confirmed with #2 counter |
Attachment 1: highparticlec.png
|
|
7650
|
Wed Oct 31 22:56:41 2012 |
Den | Update | PEM | acoustic noise |
Microphone preamp box had a low-pass filter at 2kHz, Ayaka changed it to 20 kHz by replacing 100pF capacitor with a 10pF.
We've measured frequency response of the box. Signal from the microphone was split into two. One path went to the box, while another was amplified by the gain 20 (and bandpass filter 1Hz - 300kHz) and sent to spectrum analyzer. Coherence and frequency response were measured using box output and amplified input. Low-pass filter in the box does not limit our sensitivity.
Acoustic noise significantly decreases at frequencies higher then 2kHz. So we need to modify the circuit by adding whitening filter.

I've plugged in PMC length channel into PEM board CH15 through and amplifier (gain=200) that is AC coupled to avoid ~2.5 DC V coming from PMC servo. I measured coherence with microphone that was located ~30 cm higher. Measurements show contribution of acoustic noise to PMC length in the frequency range 20-50 Hz. In this range PMC length / MC length coherence is ~0.5.
Acoustic noise couples to PMC length in a non-stationary way. 5 minutes after the first measurement I already see much higher contribution. This was already discussed here. I've made C1:X02-MADC3_TP_CH15 a DQ channel at 64kHz. This a fast PMC length channel.
Next step will be to use several microphones located around PMC for acoustic noise cancellation.

|
Attachment 3: pmc.pdf
|
|
Attachment 4: pmc_high.pdf
|
|
7680
|
Wed Nov 7 11:43:29 2012 |
Steve | Update | PEM | high particle count ALART |
The BS camber is open only. We should close ASAP
Outside air quality is 1.7- 2.2 million particles / cf min of 0.5 micron |
Attachment 1: highpartcount.png
|
|
7681
|
Wed Nov 7 14:59:35 2012 |
Steve | Update | PEM | high particle count ALART & oplevs |
Quote: |
The BS camber is open only. We should close ASAP
Outside air quality is 1.7- 2.2 million particles / cf min of 0.5 micron
|
Air is still bad and the chambers are closed. Before lunch Jamie repointed the PRM oplev. Manasa and I reset oplevs: BS and ITMX.
ETMX and ETMY are fine.
SRM and ITMY oplevs needs more work. |
Attachment 1: oplevs.png
|
|
7733
|
Tue Nov 20 15:24:52 2012 |
Ayaka | Update | PEM | Seismometers and a microphone |
I got two seismometers and one microphone back from Tara.
They are now near the Gurlap under the MC. |
7734
|
Tue Nov 20 16:03:37 2012 |
janosch | Update | PEM | Seismometers and a microphone |
Quote: |
I got two seismometers and one microphone back from Tara.
They are now near the Gurlap under the MC.
|
If anybody wants a fancy single-axis seismometer for a while (GS-13), then please let me know. |
7744
|
Mon Nov 26 10:58:20 2012 |
Steve | Update | PEM | air cond maitenance tomorrow |
Air conditioning maintenance is scheduled for tomorrow morning till noon. |
7745
|
Mon Nov 26 18:36:17 2012 |
Jenne | Update | PEM | BLRMS back |
Quote: |
I got two seismometers and one microphone back from Tara.
They are now near the Gurlap under the MC.
|
I have finally plugged GUR1 back in....it is down at ETMY for now, since that's where the cable was. BLRMS are back up on the projector. |
7754
|
Tue Nov 27 11:27:22 2012 |
Steve | Update | PEM | particle count is going up |
Jeff is still working on the filter banks. |
Attachment 1: 5yparticles.png
|
|
Attachment 2: particle_6m_6m.png
|
|
Attachment 3: 1y_particlec.png
|
|
Attachment 4: 10y_particle_c.png
|
|
7759
|
Wed Nov 28 23:18:35 2012 |
Charles | Update | PEM | Decreased RMS in Seismometers |
The attached plots display RMS noise from various accelerometers and seismometers over the past 90 days. One can see how after the reinstallation of the seismometers in November, RMS from the GUR1Z and GUR1X channels decreases by a factor of about 100 from data in August. Additionally, the RMS over the course of the last 90 days has notably decreased in all instruments. In many cases, the RMS is only the result of inherent electronics noise, rather than from a signal. |
Attachment 1: 8-31_11-29_PEM-RMS.jpg
|
|
7762
|
Thu Nov 29 02:43:48 2012 |
Ayaka | Update | PEM | Decreased RMS in Seismometers |
Quote: |
The attached plots display RMS noise from various accelerometers and seismometers over the past 90 days. One can see how after the reinstallation of the seismometers in November, RMS from the GUR1Z and GUR1X channels decreases by a factor of about 100 from data in August. Additionally, the RMS over the course of the last 90 days has notably decreased in all instruments. In many cases, the RMS is only the result of inherent electronics noise, rather than from a signal.
|
The Image is replaced
[Den, Ayaka]
We found that seismometer was working and the calibration in the filter banks should have been wrong.
We turned off the all FM2 filter in RMS filter banks.
We also installed STS seismometer. It is under the BS. Now we have spectrum of three seismometers.
 
RA: the above plot is kind of unreadable and useless. Please replace with something legible and put in some words about why there is a wrong filter, what exactly it is, etc., etc. etc. And why would you leave in a filter which is not supposed to be on? We might as well leave a few secretly broken chairs in the control room... |
Attachment 2: seismometers1129.jpg
|
|
7763
|
Thu Nov 29 09:58:06 2012 |
Den | Update | PEM | Decreased RMS in Seismometers |
Quote: |
[Den, Ayaka]
We found that seismometer was working and the calibration in the filter banks should have been wrong.
We turned off the all FM2 filter in RMS filter banks.
We also installed STS seismometer. It is under the BS. Now we have spectrum of three seismometers;
RA: the above plot is kind of unreadable and useless. Please replace with something legible and put in some words about why there is a wrong filter, what exactly it is, etc., etc. etc. And why would you leave in a filter which is not supposed to be on? We might as well leave a few secretly broken chairs in the control room...
|
First of all, STS-2 is in the end of X arm, GUR2 is under BS, GUR1 is in the end of Y arm.
BLRMS were small because we applied calibration from counts to um/s two times. In the past we had calibration in the RMS BP filter bank (vel2vel = FM2). Now we have calibration in the seismometer input filter bank so we can save calibrated _OUT channels. |
7777
|
Mon Dec 3 16:37:09 2012 |
Steve | Update | PEM | EM 172 microphones ordered |
Quote: |
I've put EM 172 microphones inside Steve's isolation box to measure their noise. I've attached mics to each other and aligned them using the tape.
At low frequencies (below 1 Hz) the noise is limited by ADC as there is a 10 Hz high-pass filter inside mic readout box.
ADC noise is measured by splitting the signal from 1 mic into 2 ADC channels.

|
BT EM172 microphones are ordered. |
7780
|
Tue Dec 4 10:44:36 2012 |
Steve | Update | PEM | short power outage |
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
**PLEASE POST**
Building: Campus
Date: Thursday October 04,2012
This morning at 2:17 a.m. much of the City of Pasadena including our Campus experienced a electric power sag of short duration, approximately 1/10 of a second. The cause was a fault on one of Pasadena’s 17KV circuits. Some sensitive equipment have been impacted.
Contact: Mike Anchondo x-4999 |
7807
|
Tue Dec 11 08:53:52 2012 |
Steve | HowTo | PEM | cables needs care |
How NOT to:
The janitor can not clean in areas like this. He may only steps on these cables accidentally as he dust wiping our chambers. |
Attachment 1: IMG_1839.JPG
|
|
7809
|
Tue Dec 11 10:09:04 2012 |
Ayaka | HowTo | PEM | cables needs care |
Quote: |
How NOT to:
The janitor can not clean in areas like this. He may only steps on these cables accidentally as he dust wiping our chambers.
|
Sorry for the mess. I fixed it. |
7819
|
Thu Dec 13 01:49:53 2012 |
rana | Update | PEM | seismometers |
Quote: |
I've installed Guralp readout box back and it turned out that it does not work with voltage provided from the rack (+13.76 0 -14.94). +/-12 voltage regulators inside the box convert it to -0.9 0 -12. I've connected the box to +/-15 DC voltage supply to measure seismic motion at the ETMY table. Readout box works fine with +/- 15.
Seismic noise on the ETMY table measured to be a few times higher then on the floor in horizontal direction in the frequency range 50 - 200 Hz. Attached are compared spectrums of X, Y and Z motions.
|
Looking at the PEM BLRMS, I noticed that the GUR1Z channel had a much reduced microseism compared to the GUR1X. Looking at the BLRMS screens everything seems ON, although its a mess (too many filters in the banks, etc. - clean this up, PEM people).
Looking at the Z channel in DTT, I see that the Z spectra looks double high pass filtered below ~1 Hz. Needs some attention in the daytime.
From Den and Ayaka's elog entry from Nov 29, its clear that this problem is there at that time. It seems that the seismometer was not even hooked up before then. Perhaps Tara returned the seismometer around Thanksgiving and then someone here hooked it up but neglected to log this work? If so, please make an elog now describing the installation of this sensor at the 40m and log any future work which takes place at the 40m lab even if you think it is inconsequential. |
Attachment 1: a.pdf
|
|
7825
|
Thu Dec 13 21:21:34 2012 |
Den | Update | PEM | seismometers |
Quote: |
Looking at the PEM BLRMS, I noticed that the GUR1Z channel had a much reduced microseism compared to the GUR1X. Looking at the BLRMS screens everything seems ON, although its a mess (too many filters in the banks, etc. - clean this up, PEM people).
Looking at the Z channel in DTT, I see that the Z spectra looks double high pass filtered below ~1 Hz. Needs some attention in the daytime.
From Den and Ayaka's elog entry from Nov 29, its clear that this problem is there at that time. It seems that the seismometer was not even hooked up before then. Perhaps Tara returned the seismometer around Thanksgiving and then someone here hooked it up but neglected to log this work? If so, please make an elog now describing the installation of this sensor at the 40m and log any future work which takes place at the 40m lab even if you think it is inconsequential.
|
Yesterday I wanted to recenter Guralps. I turned them off, understood that would be able to center them because we do not have power cable to Guralp box from Tara yet and turned them back on.
I've switched Guralp cables and spectrums are fine now. |
Attachment 1: gur.pdf
|
|
Attachment 2: gur_fix.pdf
|
|
7831
|
Fri Dec 14 09:05:04 2012 |
steve | Update | PEM | TT after eq 6.1 |
SRM, ITMY and MC3 moved some what, but how are the TT? It may worth looking at them before we vent. |
Attachment 1: eq6.1.png
|
|
7841
|
Mon Dec 17 19:47:15 2012 |
rana | Update | PEM | Seismic StripTool config updated |
I have updated the Seismic Striptool display which is plotted on the wall in the control room. Please take a look and make comments. We should finalize it and not change it anymore.
By having an unchanging display, we can get used to small changes in the seismic environment which disrupt our locking.
- y-scale is now linear; the log-scale was suppressing the factor of 2-3 variations which are important to us.
- Just as the rainbow does, the colors now go from red to purple to represent the noise from 0.1 - 30 Hz: the red traces are 0.1-0.3 Hz, the green/yellow traces are 0.3-3 Hz, and the blue/purple traces are 3-30 Hz.
- This is just showing GUR1. Let's try to keep this seismometer working so that we can have some long term record of the seismicity here. This means don't click off the buttons, disconnect the sensor, reboot the machine, etc. When you do do these things, elog them.
|
Attachment 1: SeismicRainbow.png
|
|
7923
|
Tue Jan 22 09:10:19 2013 |
Steve | Update | PEM | big foot is dirty |
Please wipe, clean car wheels and wear booties entering the 40m lab.
Obviously this person has no idea about our clean room rules. |
Attachment 1: IMG_1873.JPG
|
|
Attachment 2: IMG_1874.JPG
|
|
7942
|
Thu Jan 24 16:31:46 2013 |
Steve | Update | PEM | building exterier wall painted |
The wood exteier walls, gutters and doors were painted at CES-Annex building #69 |
Attachment 1: IMG_1880.JPG
|
|
7954
|
Tue Jan 29 14:34:42 2013 |
Jenne | Update | PEM | Secret Seis filters |
The BLRMS have been bad again, since the computer crash of last week. Finally getting around to looking into it, I discovered that there are filter banks that have the microns/sec calibration filters, which are not accessible from the sitemap. I have added links to them for GUR1 and GUR2. We need to make the PEM/BLRMS screens macro-expansion-y, so that I don't have to change each screen individually.
Anyhow, the BLRMS are back.
|
7999
|
Tue Feb 5 09:08:11 2013 |
Steve | Update | PEM | exterier doors to be painted |
Quote: |
The wood exteier walls, gutters and doors were painted at CES-Annex building #69
|
The east and south end of the 40m emergency exit doors are sealed- tapped off temporarily. They will be painted on the out side only. This job will be done by tomorrow noon
Do not open chamber if you smell the paint ! |
Attachment 1: IMG_0055.JPG
|
|
8001
|
Tue Feb 5 10:18:54 2013 |
Steve | Update | PEM | high particle count ALART |
Quote: |
Quote: |
The BS camber is open only. We should close ASAP
Outside air quality is 1.7- 2.2 million particles / cf min of 0.5 micron
|
Air is still bad and the chambers are closed. Before lunch Jamie repointed the PRM oplev. Manasa and I reset oplevs: BS and ITMX.
ETMX and ETMY are fine.
SRM and ITMY oplevs needs more work.
|
The bad outside air quality is pushing up the inside counts.
The outside air is 5 million counts / cf min for 0.3 micron and 2 million counts / cf min for 0.5 micron particles
Do not open chamber over 10,000 counts / cf min of 0.5 micron |
Attachment 1: badair.png
|
|
Attachment 2: 100d_airq.png
|
|
8010
|
Wed Feb 6 15:10:22 2013 |
Steve | Update | PEM | new safety signs on exterier doors |
Quote: |
Quote: |
The wood exteier walls, gutters and doors were painted at CES-Annex building #69
|
The east and south end of the 40m emergency exit doors are sealed- tapped off temporarily. They will be painted on the out side only. This job will be done by tomorrow noon
Do not open chamber if you smell the paint !
|
The east and south end of the 40m emergency exit doors received new safety signs. |
Attachment 1: IMG_0068.JPG
|
|
8202
|
Thu Feb 28 14:51:43 2013 |
Jenne | Update | PEM | "Rock Monster" causing low frequency noise |
Manasa and I have been wondering why the low frequency seismic noise has been different in the last few days/weeks. I went over to visit the Rock Monster, a.k.a. the Earth Surface Dynamics Laboratory next door, and the grad student turned it up for me (increased water flow significantly) for a few minutes. Then I came back to look at the BLRMS, and you can see the low frequency increase a few minutes ago, when he turned it up on high. He said that they run it on low almost all the time, 9am-5pm ish, and on high for an hour or so at a time periodically during the day.

|
8219
|
Mon Mar 4 11:30:47 2013 |
Steve | Update | PEM | air cond problem |
The air cond is out of order at the area covered by racks 1 X 1 through 1 X 7
The arm X and Y AC units are working. |
Attachment 1: 40dAC.png
|
|
8270
|
Mon Mar 11 16:29:29 2013 |
Steve | Update | PEM | proposed seismometer locations |
Granite base 20" x 20" x 5" locations are on the CES side of our IFO arms: as shown ETMY_ south-west, ETMX_north-east, ITMX_south-east . No height limitation. This side of the tube has no traffic.
SS cover McMaster# 41815T4 (H) SS container cov |
Attachment 1: ETMY_sw.jpg
|
|
Attachment 2: ITMX_se.jpg
|
|
Attachment 3: ETMX_ne.jpg
|
|
8272
|
Mon Mar 11 19:01:21 2013 |
Jenne | Update | PEM | proposed seismometer locations |
This is my interpretation of where Steve is proposing to place the seismometers (he wrote ITMX southwest, but I'm pretty sure from the photo he means southeast).
I think his point is that these locations are on the less-used side of the beam tube, so they will not be in the way. Also, they are not underneath the tube, so we will not have any problems putting the covers on/taking them off.

|
8314
|
Wed Mar 20 08:59:24 2013 |
Steve | Update | PEM | air cond maitenance is today |
Outside air quality at 8:30am 1.1 million of 0.5 micron particles cf / min with MET counter #2
AC unit output measured directly at the outlet of east end 6,000 and south end 3,000 of 0.5 micron particles cf / min with counter #2
Lab measurement at the top of IOOC 20K of 0.5 micron particles cf / min with MET #1
HEPA filters: 2 mobile units at the middle of the east arm at speed 100%, PSL enclosure 20% and south end flow bench are running.
The PSL, south flow bench and mobile unit (Envirco sn69406003 ) measured zero counts of 0.5 & 0.3 micron particles
Envirco HEPA filter unit sn 69406001 measured 50 particles of 0.5micron and 320 of 0.3 micron particles cf / min with counter #2
This filter will be replaced.
NOTE: inside air quality peaks we can not control. It depends on the weather and our house keeping.
When your work is particle sensitive keep your eyes on the particle counter.
|
Attachment 1: 100dPEM.png
|
|
8456
|
Mon Apr 15 16:10:52 2013 |
Den | Update | PEM | seismometer isolation kit |
We got granite bases today from the manufacturer. We plan to set them up on Wednesday, 8 am. Please note, there will be an installation mess at Xend, Yend and corner during ~4 hours. Let us know if you have any objections to do this at this particular time.
Installation locations are specified in elog 8270, scheme attached is valid except for Xend. Instrument will be installed on the place of nitrogen containers.
( next to the wall at corner sout-east of the south end ) |
8461
|
Thu Apr 18 15:08:14 2013 |
Steve | Update | PEM | seismometer isolation kit in place |
Quote: |
We got granite bases today from the manufacturer. We plan to set them up on Wednesday, 8 am. Please note, there will be an installation mess at Xend, Yend and corner during ~4 hours. Let us know if you have any objections to do this at this particular time.
Installation locations are specified in elog 8270, scheme attached is valid except for Xend. Instrument will be installed on the place of nitrogen containers.
( next to the wall at corner sout-east of the south end )
|
The carpenter shop finished the installation of the 3 granite bases.Rapid Set Cement All high strength non-shrink grout was used.
Compressive strength 3000 PSI at 1 hour and 9000 PSI at day 28 The janitor is still cleaning up after them at the south end.
The soft silicon gas kits are working well with the SS can. Den is making the adaptor plate drawing for the feedthrough. |
Attachment 1: grouting1.jpg
|
|
Attachment 2: grouting2.jpg
|
|
Attachment 3: grouting3.jpg
|
|
Attachment 4: grouting4.png
|
|
8466
|
Fri Apr 19 15:19:25 2013 |
Jamie | Update | PEM | Trilliums moved from bench to concrete |
I moved the two Trillium seismometers that Den left on the electronics bench out onto the new concrete blocks in the lab that will be their final resting places. I moved one onto the slab at the vertex and the other to the slab at the Y end. I left them both locked and just sitting on the concrete.
The pile of readout electronics that were sitting next to them I moved on to the yellow foam box half way down the MC tube, between the MC tube and the X arm tube. This is obviously not a good place to store them, but I couldn't think of a better place to put them for the moment. |
8477
|
Tue Apr 23 16:17:45 2013 |
Den | Update | PEM | seismometer isolation kit in place |
Quote: |
The carpenter shop finished the installation of the 3 granite bases.Rapid Set Cement All high strength non-shrink grout was used.
Compressive strength 3000 PSI at 1 hour and 9000 PSI at day 28 The janitor is still cleaning up after them at the south end.
The soft silicon gas kits are working well with the SS can. Den is making the adaptor plate drawing for the feedthrough.
|
To put everything in one place I add a final drawing of the base to this elog.
Next time we continue with wiring and putting temperature and pressure sensors inside the box. Connector support plate drawing is attached. We'll have sensors inside the kit with STS-2 or Trillium as their connector is small enough (19 pin vs 26 pin for Guralps) that we can put an additional 4 pin lemo connecor (2 pins for each sensor). I think EGG.0B.304.CLL is good for this application. Temperature and pressure sensor we can by from omega. |
Attachment 1: Base.pdf.pdf
|
|
Attachment 2: ConnectorPlate.pdf
|
|
8526
|
Fri May 3 08:55:55 2013 |
Steve | Update | PEM | 3.2 M earthquake |
|
Attachment 1: 3.2eqChannelIland.png
|
|
Attachment 2: 3.2eq.png
|
|
8558
|
Thu May 9 02:47:23 2013 |
Jenne | Update | PEM | T240 at corner station - cabling thoughts |
Something that I want to look at is the coherence between seismic motion and PRM motion. Since Den has been working on the fancy new seismometer installations, I got caught up for the day with getting the new corner seismometer station set up with a T240. Later, Rana pointed out that we already have a Guralp sitting underneath the POX table, and that will give us a good first look at the coherence. However, I'm still going to write down all the cable thoughts that I had today:
The cables that came with the electronics that we have (from Vladimir and tilt meter -land) are not long enough to go from the seismometer to 1X7, which is where I'd like to put the readout box (since the acquisition electronics are in that rack). I want to make a long cable that is 19pin MilSpec on one end, and 25pin Dsub on the other. This will eliminate the creative connector type changes that happen in the existing setup. However, before making the cable, I had to figure out what pins go to what. So.
25pin Dsub 19pin MilSpec
1 P
2 N
3 E
4 No conn
5 D
6 R and V
7 H
8 J
9 No connection
10 T
11 F
12 L
13 No conn
14 B
15 A
16 R and V
17 No conn
18 C
19 G
20 G
21 K
22 U
23 No conn
24 S
25 M
I am not sure why R and V are shorted to each other, but this connection is happening on the little PCB MilSpec->ribbon changer, right at the MilSpec side. I need to glance at the manual to see if these are both ground (or something similar), or if these pins should be separate. Also, I'm not sure why 19 and 20 are shorted together. I can't find (yet) where the short is happening. This is also something that I want to check before making the cable.
Den had one Female 19 pin MilSpec connector, meant for connecting to a T240, but the cable strain relief pieces of the connector have 'walked off'. I can't find them, and after a solid search of the control room, the electronics bench, and the place inside where all of Den's connectors were stored, I gave up and ordered 2 more. If we do find the missing bits for this connector, we can use it for the 2nd T240 setup, since we'll need 2 of these per seismometer. If anyone sees mysterious camo-green metal pieces that could go with a MilSpec connector, please let me know. |
8567
|
Mon May 13 23:05:51 2013 |
Jenne | Update | PEM | GUR1 masses recentered |
[Evan, Jenne]
Evan brought the Guralp handheld readout paddle and cables back from the ATF (Zach is using GUR2 and one of the T240s for gyro stuff this week), and we recentered the GUR1 masses. N/S and Vert were okay (within 0.1 V), but E/W was at -0.5 V, so we set it at zero. We then plugged the Guralp back in, and turned on the readout box.
There isn't much of a change on the BLRMS on the wall, so it's possible that we weren't actually having any trouble anyway. |
8634
|
Thu May 23 20:58:49 2013 |
Jenne | Update | PEM | PRM, ITMX optics tripped, restored |
- Time
- Location
- 40.190°N 121.064°W
- Depth
- 0.0km
|
8752
|
Wed Jun 26 01:30:31 2013 |
rana | Summary | PEM | Variation in 10-30 Hz seismic RMS |
For quite a while (no one knows how long), we've seen fluctuations in the 10-30 Hz seismic motion. This shows up as the purple trace on the seismic BLRMS on the wall projector.
The second plot shows that this is not only a periodic increase in the usual 29.5 Hz HVAC peak, but also an anomolous 32.2 Hz peak. Probably some malfunctioning machinery - maybe in the 40m or maybe on the roof. |
Attachment 1: gur1z_rms.pdf
|
|
Attachment 2: gur1z.pdf
|
|
8764
|
Thu Jun 27 15:50:03 2013 |
Jenne | Update | PEM | BLRMS are going crazy |
The BLRMS are totally crazy today! I'm not sure what the story is, since it's been this way all day (so it's not an earthquake, because things eventually settle down after EQs). It doesn't seem like anything is up with the seismometer, since the regular raw seismic time series and spectrum don't look particularly different from normal. I'm not sure what's going on, but it's only in the mid-frequency BLRMS (30mHz to 1Hz).
Here are some 2 day plots:



|
8765
|
Thu Jun 27 15:58:27 2013 |
Steve | Update | PEM | PSL enclosure particle counts |
Particle counts were measured inside the PSL enclosure at 40VAC variac setting.
Directly under HEPAs, on the east half of the optical table : 0.3 micron 20 particles / cu ft, 0.5 micron 0 p / cu ft, 0.7 micron 0 p / cu /ft
Away from the HEPAs, on the west edge of the op table: 0.3 micron 960 particles / cu ft, 0.5 micron 50 p / cu ft, 0.7 micron 20 p / cu ft
We may want to increase the RPM a little bit.
Checked our counters against recently calibrated Met One GT-526:
#1 is right on, #2 measured 25% less (it will go for calibration)
Flow bench at the south end : zero particle for all 3 sizes
IOO chamber particle logging measures 0.5 and 1 micron. Chamber opening limit is set to 10,000 particles max of 0.5 micron
At 10,000 p of 0.5 micron means ~100,000 - 180,000 p of 0.3 micron
We may have to lower the limit. |
8773
|
Thu Jun 27 21:45:48 2013 |
rana | Update | PEM | BLRMS are going crazy |
Its an increase in the microseismic peak. Don't know what its due to though. |
Attachment 1: useism.pdf
|
|
8856
|
Tue Jul 16 13:48:26 2013 |
Steve | Update | PEM | cranes cleaned |
Keven and Steve,
The 3 cranes tested and wiped off as preparation for upcoming vent. |
8925
|
Thu Jul 25 14:45:06 2013 |
rana | Update | PEM | Guralp specgram with ligoDV and NDS2 |
Once you install a matlab newer than 2012a, you can install ligoDV as a matlab app and get the NDS2 client software for free. So you can easily get the 40m data from the outside world now and do the analysis on your own computer rather than login through nodus. |
Attachment 1: a.pdf
|
|
8954
|
Thu Aug 1 16:33:39 2013 |
Sujan | Update | PEM | Guralp2 seismometer installed at North side of POX table |
1)Power to the seismometers were turned down,
2)Guralp2 was moved to North side of POX table
3)Guralp2 was aligned in N-s Direction and leveled before connecting
4)Power to seismometers was turned on once Guralp2 was connected

|