ID |
Date |
Author |
Type |
Category |
Subject |
7089
|
Mon Aug 6 10:53:32 2012 |
steve | Update | VAC | status: vauum normal |
The power outage did not have any effect on the vacuum system. I had to open VM1 to the RGA because of flaky CC1 cold cathode gauge fluctuations.
We are running on the vertically positioned CC1 again.
Note: rga scans with closed VM1 are back ground scans. |
Attachment 1: CCgauges.png
|
|
7088
|
Mon Aug 6 09:46:31 2012 |
steve | Update | IOO | poweroutage turns laser off |
. Power outage turned off the PSL Innolight laser on Sunday afternoon. It was turned back on and locked happily right on. The green lasers were not effected.
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
UTILITY & SERVICE INTERRUPTION
**PLEASE POST**
Building: CAMPUS WIDE
Date: SUNDAY, AUGUST 6, 2012
Time: 3:41 PM
Interruption: ELECTRICAL POWER DISTRIBUTION
Contact: MIKE ANCHONDO, X-4999, OR TOM BRENNAN, X-4984
* THIS PAST SUNDAY AFTERNOON ABOUT 3:40 PM, PASADENA WATER AND POWER
EXPERIENCED A FAULT ON THEIR POWER DISTRIBUTION SYSTEM. THIS CAUSED
A SEVERE VOLTAGE SAG WHICH AFFECTED THE CALTECH CAMPUS. THE FAULT WAS
NOT ON A CALTECH CIRCUIT.
(If there is a problem with this Interruption, please notify
the Service Center X-4717 or the above Contact as soon as possible.
If no response is received we will proceed with the interruption.)
Jerry Thompson,
Interim Director of Campus Operations & Maintenance
|
7087
|
Mon Aug 6 07:59:33 2012 |
steve | Update | SUS | PRM oplevs servo is still bad |
Quote: |
Quote: |
Quote: |
Yuta claims he fixed the PRM oplev by centering it the other day, but no one has left it on and watched it for a long while, to make sure it's okay. We watched it now for ~2 min, and it was good, but we're leaving the oplevs off anyway for the night. Tomorrow we should restore PRM (it's currently restored), turn on the oplevs, and let it sit to make sure it doesn't go crazy.
|
PRM oplev servo was turned on with PITgain 0.5 and YAWgain -0.7
Note: gain settings were PIT 1.0 and YAW --0.5 on Jun 1, 2012 that I measured Feb 23, 2012
|
It is still oscillating. Gains turned down to zero.
|
Earthquake test our suspensions PRM damping restored. Oplev servo gains turned to zero. |
Attachment 1: PRMeq.png
|
|
7086
|
Sun Aug 5 13:48:40 2012 |
Den | Update | CDS | Move to RCG 2.5 tag release |
Quote: |
I moved the RCG to the advLigoRTS-2.5 tag
|
After that RFM -> OAF communication through PCIE became bad again. Inside CommData2.c cache flushing is not allowed
// If PCIE comms show errors, may want to add this cache flushing
#if 0
if(ipcInfo[ii].netType == IPCIE)
clflush_cache_range (ipcInfo[ii].pIpcData->dBlock[sendBlock][ipcIndex].data, 16);
#endif
As a result, a significant part of MC_F and other signals is lost during RFM -> OAF transmission (270 - 330 out of 2048 per second)

Last time when I replaced 0 for 1, it suspended SUS machine because of the code bug. Alex modified a couple of files in the old version and it started to work. Do you know if this bug is fixed in the new version?
|
7085
|
Sat Aug 4 17:32:31 2012 |
Den | Update | digital noise | filter checker | The script estimates digital noise produces by online filters. First version of Matlab files and complied c files are in scripts/digital_noise directory.
Algorithm for 1 filter bank (max number of filters = 10):
- extract sos - representation from Foton file for each filter (Matlab)
- download data from corresponding DQ channel using NDS (Matlab)
- find filters that are switched on (Matlab)
- filter signal using Df2 and BQF with single and double precision (C)
- estimate digital filter noise (Matlab)
- calculate power spectral density and plot the result (Matlab)
More details on (2)
Often DQ channels have reduced sampling rate. In this case the script will upsample data adding zeros.
AI filter is not applied. But in the end only the frequency range (0, DQ RATE / 2) is analyzed.
More details on (3):
This is done by reading C1:MODEL-BANK_NAME_SW1R and C1:MODEL-BANK_NAME_SW2R channels.
_SW1R channel value is the sum of the following numbers:
- input switch ON / OFF => 4 / 0
- filters 1 - 6 ON /OFF
- 1 => 48 / 0
- 2 => 192 / 0
- 3 => 768 / 0
- 4 => 3072 / 0
- 5 => 12288 / 0
- 6 => 49152 / 0
- If a switch is ON but there is no corresponding filter (one green and one red line under the switch) then the switch value is divided by 3
_SW2R channel value is the sum of the following numbers:
- decimation switch ON / OFF => 512 / 0
- output switch ON / OFF => 1024 / 0
- filters 7 - 10 ON /OFF
- 7 => 3 / 0
- 8 => 12 / 0
- 9 => 48 / 0
- 10 => 192 / 0
- If a switch is ON but there is no corresponding filter (one green and one red line under the switch) then the switch value is divided by 3
Note: as for now Matlab script assumes that input, output and decimation filters are switched ON and there are no turned ON filter switches that do not correspond to any filters
More details on (5)
Digital noise using double precision is estimated by extrapolation of digital noise with single precision. The last is calculated by subtracting outputs of the filters with single and double precision. Then this noise is multiplied by 3 * 10-7.
This extrapolation number was achieved by printf tests of the number 0.123456789012345678 with single and double precision on C. Using type 'float' variables 10 significant numbers show up, using type 'double' - 17.
I also did 'calibration tests' to achieve extrapolation number - signal was filters with an aggresive low-pass filter. At high frequencies filter output spectrum is flat => digital noise amplitude must be the same. The plot shows GUR1_X channel filtered with low-pass chebyshev type 1 filter.

However, extrapolation number is not the same for all cases. In the following example of analyzing BS_SUSPOS filter bank using extrapolation 3 * 10-7 we get noise that is slightly overestimated. In some other examples we need to take a larger number. But in average, I think, this is a good approximation.

To avoid extrapolation problem we can use long double precision (~19 digits). I was able to do this with gcc compiler. However, in mex compiler using long double in filter calculations, I do not get any better precision then using double precision. I'll think more about it. |
7084
|
Fri Aug 3 14:52:11 2012 |
Jenne | Update | PEM | shims |
Quote: |
As we do not have legs for Trillium, I was advised to use shims to adjust the levels. However, they produce extra resonance at ~30 Hz + harmonics. Coherence is lost at these frequencies.
|
Brian Lantz / Dan Clark are looking around their lab to see if they forgot to ship the feet with the T-240. They had taken the feet off to put it in a pod. |
7083
|
Fri Aug 3 13:05:28 2012 |
Den | Update | PEM | shims | As we do not have legs for Trillium, I was advised to use shims to adjust the levels. However, they produce extra resonance at ~30 Hz + harmonics. Coherence is lost at these frequencies.

|
7082
|
Fri Aug 3 03:24:13 2012 |
Jenne | Update | ASS | New ASS screens | I wanted to try out the ASS tonight, but I wanted some kinds of screens thrown together so I would know what I was doing. Turns out screens take longer than I thought. Am I surprised? Not really.
They're probably at the ~85% mark now, but I should be able to try out the ASS tomorrow I think. |
7081
|
Thu Aug 2 23:31:04 2012 |
Jenne | Update | ASS | Major cleanup of the ASS model | Jamie re-redid the ASS model a few hours ago.
I have just compiled it, and restarted c1ass. (The model from last night is currently called c1ass3.mdl) I had to delete and re-put inthe goto and from tags for the LSC signal coming in from the shmem. For some reason, it kept claiming that the inputs using the from tags were not connected, even when I redid the connections. Finally deleting and dragging in new goto and from tags made the model happy enough to compile. Whatever. I'm going to let Jamie do the svn-ing, since he's the one who made the changes. Before I had figured out that it was the tags, I was concerned that the shmem was unhappy, so there was no signal connecting to the input of the goto tag, and that was somehow bad....anyhow, I recompiled the LSC model to re-create the shmem sender, but that had no effect, since that wasn't the problem.
The change from last night is that now the library parts are by DoF. There is only one matrix in each library part, before the servo filters. Now we can DC-actuate on a single mode (ETM or ITM, pitch or yaw), and see how it affects all 4 sensors (the demodulated signals from the lockins). We need to measure the sensing matrix to go from the several sensors to the servo input. |
7080
|
Thu Aug 2 22:52:23 2012 |
Masha | Configuration | PEM | STS, GUR2, and Trillium in isolation box. | Den and I moved the Streckeisen, Guralp 2, and Trillium seismometers to the isolation box in order to measure the noise of the Streckeisen while we have the Trillium. |
7079
|
Thu Aug 2 21:40:55 2012 |
Jamie | Update | Simulations | ETMX simplant model revived | I revived the ETMX simplant model, c1spx. It's running on cpu4 on c1iscex, and interfaces with C1scx via SHMEM.
The channel names for the simplant suspensions will be SUP, so the channel from this model will C1:SUP-ETMX_.
Next I'll try to get the ITMX and LSC ("LSP") simplant models running so we can run a "full" cavity simulation.
Sasha has been working on LSP, so we should be ready to do something with that soon. In the mean time she's going to fix up the SPX MEDM screens, since some channel names have been changed since it was last run. |
7078
|
Thu Aug 2 11:09:52 2012 |
Eric | Summary | LSC | Free-Swinging Michelson Measurements | To take the free swinging Michelson measurements for the interferometer calibration Jamie aligned the beam splitter with ITMX and ITMY. I recorded the GPS time (1027827100 and for several hundred seconds later) when the Michelson was aligned in order to look at the correct data. I then copied the python script nds-test.py from Jamie, and modified it to take and plot data from C1:LSC-AS55_Q_ERR_DQ offline. I used dataviewer to verify that C1:LSC-AS55_Q_ERR_DQ and C1:LSC-AS55_Q_ERR were recording the same signal, and to check that I was taking the correct data with NDS. Taking data online worked as well, but it was easier to use a time when the Michelson was known to be free-swinging and take data offline. Attached is some sample data while free-swinging, with time in GPS time. |
Attachment 1: free_swing_MICH.png
|
|
7077
|
Thu Aug 2 04:58:00 2012 |
Masha | Update | PEM | 70 Meter Long Guralp 1 Cable | The parts Jenne and I ordered arrived today, so we made a long cable for Guralp 1 using a 24 + 1 wire 70 meter long cable, a female 37-pin DSub, and a 26-pin milspec. The pin map is the same as the one I specified in my previous E-log. I soldered both the milspec attachment and the DSub attachment, and used a Multimeter to check the connectivity of the cables. 20 of 20 connections worked (beeped), so I plugged the cable into the Gurlap 1 seismometer and the Guralp box.
The time series comparison for the two cables
Old cable:

New cable: (I had to move GUR 1, so it's still stabilizing in the X and Y time series)
New
The current signal spectrum

The BLRMS on the seismic strip also look similar using the two cables - it's more visible on the wall, but I will include a StripTool picture:
New Cable BLRMS (similar to old cable BLRMS)
 |
7076
|
Thu Aug 2 03:06:57 2012 |
Sasha | Update | Simulations | LS Plant (LSP) is officially ONLINE | My ls plant compiled!! The RCG code can now be found in /opt/rtcds/rtscore/tags/advLigoRTS-2.5. I uploaded a copy of c1lsp.mdl onto the svn.
The weird "failed to connect" error was due to the fact that I named my inputs the same thing as my goto/from tags, so the RCG got confused. Once I renamed my inputs, it worked! I'm not sure what happened to the original "not enough parts" error; it didn't appear a single time during the rebuilding process. Anyway, I made the PDH block much neater, though the lines between PDH and ADC are looking wonky (this is purely an aesthetic problem, not a "oh god my simulation will DIE right now if I don't fix it" problem). I'll fix it in the morning; screenshot attached!
The original c1lsp was kind of sad. I updated it extensively and brought it into the modern era with color. The original c1lsp.mdl should also be on the svn. Tommorow, I'll get started on figuring out how to get LIGO specific noises from white noise. |
Attachment 1: Screenshot-1.png
|
|
7075
|
Thu Aug 2 00:43:55 2012 |
Jenne | Update | ASS | Major cleanup of the ASS model | [Jamie, Jenne]
We are trying to figure out what the story is with the ASS, and in order to make it more human parse-able, we cleaned up the c1ass.mdl.
So far, we have made no changes to how the signals are routed. The local oscillators from each lockin still get summed, and go directly to the individual optics, and the demodulated signals from each lockin go through the sensing matrix, the DoF filters, then the control output matrix, and then on to the individual optics. So far, so good.
Much of the cleanup work involved making a big library part, which is then called once for PIT and once for YAW in the ass top level, rather than have 2 code-copies, which give Jamie conniptions. Inside the library part GoTo and From tags were used, rather than having all the lines cross over one another in a big spaghetti mess.
One of the big actual changes to the ass was some name changes. Rather than having mysterious "ASS-LOCKIN(1-30)", they are now named something like "ASS-PIT_LOCKIN_ETMY_TRY", indicating that this is in the pitch set, actuating on ETMY, and looking at TRY for the demodulated signal. The "DOF" channels are similar to what they were, although we would like to change them in the future.....more on this potential change later. Previously they were "ASS-DOF(1-10)", but now they are "ASS-PIT_DOF(1-5)" and "ASS-YAW_DOF(1-5)". This channel naming, while it makes things make more sense, and is easier to understand, means that all of the ASS scripts need to be fixed. However, they all needed updating / upgrading anyway, so this isn't the end of the world.
This channel name fixing also included updating names of IPC (shmem/dolphin/rfm things) blocks, which required matching changes in the SUS, RFM and LSC models. All 4 models (ASS, SUS, RFM, LSC) were recompiled and installed. They all seem fine, except there appears to be a dolphin naming mismatch between OAF and SUS that showed up when the SUS was recompiled, which presumably it hadn't been in a while. We need to figure this out, but maybe not tonight. Den, if you have time, it would be cool if you could take a look at the OAF and SUS models to make sure the names match when sending signals back and forth.
______________________
We also had a long chat about the deeper meaning of the ASS.
What should we be actuating on, and what should we be sensing? A potential thought is to rename our DOF channels to actual DoF names: input axis translation, input axis angle, cavity axis translation, cavity axis angle. Then actuate the dither lines on a cavity degree of freedom, sense the influence on TRX, TRY and an LSC PD (as is currently done), then actuate on the cavity degree of freedom.
Right now, it looks like the actuation is for individual optics, the sensing is the influence on TRX, TRY and an LSC PD, then actuate on a cavity degree of freedom. So the only change with the new idea is that we actuate in the DoF basis, not the optics basis. So the Lockin local oscillators would go through the control output matrix. This makes more sense in my head, but Jamie and I wanted to involve more people in the conversation before we commit.
The next question would be: how do we populate the control output matricies? Valera (or someone) put something in there, but I couldn't find anything on the elog about how those values were measured/calculated/came-to-be. Any ideas? If we want to dither and then push on isolated degrees of freedom, we need to know how much moving of which optics affects each DoF. Is this something we should do using only geometry, and our knowledge of optic placements and relative distances, or is this measurable? |
7074
|
Wed Aug 1 22:37:21 2012 |
Jenne | Update | ASS | Filters installed in the ASS | As part of trying to figure out what is going on with the ASS, I wanted to figure out what filters are installed on which lockins.
Each "DoF"(1-6) has a zpk(0.1,0.0001,1)gain(1000), which is a lowpass with 60dB of gain at DC, and unity gain at high frequencies.
For the lockins, since there are so many, I made a spreadsheet to keep track of them (attached).
So, what's the point? The point is, I think that all of the LOCKIN_I filter modules should be the same, with a single low pass filter. The Q filter banks don't matter, since we don't use those signals, and the signals are grounded inside the model. The phase of each lockin was / should be tuned such that all of the interesting signal goes to I, and nothing goes to Q. The SIG filter modules seem okay, in that they're all the same, except for their band pass frequency. I just need to check to see what frequency the ASS scripts are trying to actuate at, to make sure we're bandpassing the correct things.
|
Attachment 1: ASS_lockin_filters_1Aug2012.pdf
|
|
7073
|
Wed Aug 1 18:20:58 2012 |
Jamie | Update | LSC | Yarm recovered | [Jenne, Jamie]
We recovered lock and alignment of the Y arm. TRY_OUT is now at ~0.9, after tweaking {I,E}TMY pit/yaw and PZT2. YARM_GAIN is 0.1.
I saved ITMY, ETMY, and PZT2 alignments in the IFO_ALIGN screen with the new alignment save/restore stuff I got working.
Working on getting Yarm ASS working now... |
7072
|
Wed Aug 1 17:04:22 2012 |
Jenne | Update | SUS | spare SRMU 03 optic moved |
Quote: |
There was one NOT MARKED SOS with two broken magnets on its face. This is labeled ???
|
While I'm not sure what specific optic this is, I think it's an older optic. (a) All of the new optics we got from Ramin were enscribed with their #. (b) This optic appears to have a short arrow scribe line (about the length of the guiderod), and then no scribe line (that I could see through the glass dish) on the other side. The new optics all have a long arrow scribe line, ~1/2 the full width of the optic, and have clear scribe lines on the opposite side. |
7071
|
Wed Aug 1 16:38:46 2012 |
steve | Update | SUS | spare SRMU 03 optic moved | SOS optics prepared to be hanged are moved from the South Flow Bench to S15 Clean Cabinet.
SRMU 03 (1-25-2010) specification summery E080460-05-D, older vintage SRM 01 and PRM 02 (need more specification)
There was one NOT MARKED SOS with two broken magnets on its face. This is labeled ???
This was done to prepare clean space for TIP-TILT drive- test set up.
The existing cable from 1X5 can reach only to the south end: from whitening filter to satelite amp. This will be good for future test of suspensions.
We need to make new cable from 1 X 1 to the south end = 40m long |
Attachment 1: IMG_1464.JPG
|
|
Attachment 2: IMG_1465.JPG
|
|
Attachment 3: IMG_1466.JPG
|
|
7070
|
Wed Aug 1 15:14:20 2012 |
Jenne | Update | IOO | PSL Pointing QPD signals lost in late-June 2012 | I was looking into why we don't have any light on the PSL pointing QPDs, and it turns out that it has been this way since ~June 29th 2012. I need to look back in the elog to see what was going on on the PSL table that day, but I suspect it has something to do with Yuta and I, working on the beat setup, since this is all very near that area.
Attached is a plot of the loss of signal on the QPDs.
UPDATE:
We lost IP POS on the same day as we lost the PSL pointing. See 2nd attachment. The _S_Calc is the sum, and it almost looks like the light got near the edge of the diode and just kept falling off until it was gone. The sum started getting lower on May 16th, and then was gone on June 29th.
So far I've gone back as far as Jan 2012, but I still haven't found any data where we *did* have light on IP ANG. Sad.
UPDATE, UPDATE (like P.P.S.): June 29th was the day of the vent...see elog 6895. |
Attachment 1: IOO_QPDs_lost_midJune2012.png
|
|
Attachment 2: IP_QPDs_lost_midJune2012.png
|
|
7069
|
Wed Aug 1 15:02:29 2012 |
Jenne | Update | IOO | IP POS QPD centered | Jamie went out to look at IP POS, and the beam was *way* off. Even though our alignment is still rough, we're kind of close right now, so Jamie put the beam back on the QPD, but we need to recenter IPPOS after we get good alignment. |
7068
|
Wed Aug 1 11:54:59 2012 |
Yaakov | Summary | STACIS | Geophone calibration and open loop gains | This week I've looked into finding an accurate sensitivity for the geophones in the STACIS. I found that when placing a geophone and accelerometer side by side, and using the sensitivity values I had from spec sheets, the readings were very different (see eLog 7054: http://nodus.ligo.caltech.edu:8080/40m/7054).
I cut the shunt resistor off one of the STACIS geos and found it to be 4000 Ohm, which is one of the standard values for this geophone model. When it is connected to the geophone the net resistance is 2000 Ohm (I took a more careful measurement, I took the geophone out). Then the internal coil resistance should be 4000 Ohm, if they are connected in parallel. However, the geophone spec sheet does not have a sensitivity value for this exact scenario, so I'll have to find a different way to determine the calibration (maybe by putting it next to a seismometer with a known sensitivity). So I know for sure that the sensitivity value I was originally using is wrong, because it assumed an internal coil resistance of 380 Ohm, but I have to check if the value I found by forcing the geophones to agree with the accelerometers (eLog 7054 --> 0.25 (m/s)/V) is correct.
I've also been looking again at the open loop gains of the STACIS (see eLog 7058: http://nodus.ligo.caltech.edu:8080/40m/7058). Attached is what TMC, which makes the STACIS, says it should look like (with a 4000 lb load on the STACIS). Today I am taking the open loop gains into higher frequencies to get a better comparison, but the plots look quite similar to what I have so far. So if it is an unstable open loop gain, then it's at least not new. |
Attachment 1: 08011201.pdf
|
|
7067
|
Wed Aug 1 11:50:49 2012 |
Jamie | Update | CDS | added input monitors to LSC_TRIGGER library part | I added an EPICS monitor to the input of the LSC_TRIGGER part, to allow monitoring the signal used for the trigger. I then added the monitors to the C1LSC_TRIG_MTRX screen (see below). This should hopefully aid in setting the trigger levels. |
Attachment 1: trigmtrx.png
|
|
7066
|
Wed Aug 1 11:46:16 2012 |
Masha | Summary | General | Week Summary | A lot of my time this week was spent struggling with implementing my neural network code in Simulink in order to experiment with using neural network control systems, as Rana suggested. Perhaps I'm inept at S-Functions, but I decided try to use the Model Reference Controller block in Simulink instead of my own code, and experiment with using that to control a driven, damped harmonic oscillator with noise. The block consists of two neural networks, one which is trained on a model of the plant to simulate the plant, and one that it trained on a reference model (which, in my case, is just input -> gain 0 -> output since my desired signal for now is 0. So far, I have managed to adjust the parameters enough to stop the neural network controller from outputting too much force (this causing the amplitude of the oscillator to increase with each iteration), but outputting enough to keep the plant oscillating with a maximal displacement of 2 m/s (with 30 neurons, 100 reference time delays, and 100 plant output time delays). I will continue to work on this, especially with added noise sources, and see how feasible it is to train such a controller to actually perform well.


As far as classification, I took up that project again, and realized that I have been approaching it the wrong way the whole time - instead of using a neural network to classify an entire time series, I could just classify it online using a recurrent neural network. This, however, meant that my data (which used to be in packets of 900 seconds) had to be parsed through to generate time-dependent desired output vectors. I did this last night, and have been trying various combinations of neuron numbers, time delays, and learning parameters this morning. Below is my current best result for mean square error with time, obtained with 1 neuron in the hidden layer, 50 time delays (so that there are actually 51 neurons feeding into the hidden layer, and a subnetwork of 50 neurons connected to 50 neurons, and learning parameter 0.7). The peak is due to the fact that a large amount of sharp earthquakes occur around that time, essentially giving the neural network a surprise, and causing it to rapidly learn. However, I suspect this sharp rise would decrease if I were to stop decimating my data by a factor of 256, and using all of the inputs as they come in (this, however would be drastically slower). Currently, I have a massive loop running which tries different combinations of neurons and time delays.

In terms of other lab stuff, Jenne and I ordered parts to make a cable for Gurlap-1, and I updated the pin map for Gurlap-1. Also, I wrote my progress report.
|
7065
|
Wed Aug 1 10:45:38 2012 |
Sasha | Summary | Simulations | SURF - Week 6 - Summary | This week, I worked on transferring my Simulink simulation to the RCG. I made all relevant library parts, now under "SASHA library" in the main Simulink library browser. My main concern has been noises - I've added some rudimentry shot noise, amplitude noise, phase noise, and intensity noise. I have yet to add local oscillator noise, and plan to upgrade the existing noises to actually have the PSD they should (using equations from Rana's and Robb Ward's theses). I'm fairly certain this can be achieved by applying the correct transfer function to white noise (a technique I learned from Masha this week!), so the RCG should be able to handle it (theoretically).
I've also been tweaking my main simulation. After a brief (but scary) attempt at adding optical levers, I decided to shelve it in order to focus on noises/RCG simulating. This is not permanent, and I plan to return to them at some point this week or next. My main problem with them was that I knew how to get from optical lever input to pitch/yaw, but had no idea how to get from pitch/yaw to optical lever input. If I had a complete basis for one in terms of the other, I'd be able to, but I don't think this is the way to go. I'm sure there is a good way to do it (it was done SOMEHOW in the original simulation of the suspensions), I just don't know it yet.
In the aftermath of the optical lever semi-disaster, my simulation is once again not really outputting anything, but since it actually worked before adding the optical levers, I'm pretty sure I can get it to work again (this is why its important to use either git or BACKUPS, >.< (or both)).
We also wrote our progress reports this week. Mine includes some discussion on the basics of cavities/the mechanics of the suspensions/brief intro to PDH, and I'll add a section on noises in the next draft. Maybe this'll be of some use to someone someday? One can only hope.
|
7064
|
Wed Aug 1 10:38:11 2012 |
Eric | Summary | General | SURF Update | Since my last update I have modified the DARM control loop model to the extent that it resembles the
measured open loop transfer function much more closely. The phase especially is much more accurate, with
a phase margin of about 35 degrees at the unity gain frequency of 156 Hz. Right now I'm normalizing to
the unity gain frequency still to adjust the gain properly. Using the length response function from the
model, I can calibrate the error signal as well to find the simulated h(t) output. There were a number of
computational problems in calculating the length response function, but I eventually found a work-around.
Attached is an updated plot of the open loop transfer function and the length response function of the model.
This week Jamie showed me around the real-time Simulink models as well. The one specific to my project
is c1cal.mdl. It takes the output in the form of the error and control signals from c1lsc.mdl as its
input and produces the calibrated signal as output. In order to produce the calibrated signal we need the actuation
function and the inverse of the sensing function for the model as it stands now. We also built, installed,
and restarted the c1cal model because no data was showing up in data viewer, but the problem remained
after this attempt.
Jamie and I also started on calibrating the interferometer in the traditional way. Jamie aligned the beam
splitter and the input test masses so we could take free-swinging Michelson measurements. However, taking
the data with the nds system appears to be giving different results than what is showing up in data viewer.
The goal of this measurement is to get a value for the peak to peak amplitude of the Michelson error signal. |
Attachment 1: OLG_hendries.png
|
|
Attachment 2: Length_response_hendries.png
|
|
7063
|
Wed Aug 1 10:07:16 2012 |
Liz | Update | Computer Scripts / Programs | Week 7 Update | Over the past week, I have continued refining the summary pages. They are now online in their final home, and can be easily accessed from the 40 meter Wiki page! (It can be accessed by the Daily Summary link under "LOGS"). I have one final section to add plots to (the IFO section is currently still only "dummy" plots) but the rest are showing correct data! I have many edits to make in order for them to be more intelligible, but they are available for browsing if anyone feels so inclined.
I also spent quite a while formatting the pages so that the days are in PDT time instead of UTC time. This process was quite time consuming and required modifications in several files, but I tracked my changes with git so they are easy to pinpoint. I also did a bit of css editing and rewriting of a few html generation functions so that the website is more appealing. (One example of this is that the graphs on each individual summary page are now full sized instead of a third of the size.
This week, I also worked with the BLRMS mic channels I made. I edited the band pass and low pass filters that I had created last week and made coherence plots of the channels. I encountered two major issues while doing this. Firstly, the coherence of the channels decreases dramatically above 40 Hz. I will look at this more today, but am wondering why it is the case. If nothing could be done about this, it would render three of my channels ineffective. The other issue is that the Nyquist frequency is at 1000 Hz, which is the upper limit of my highest frequency channel (300-1000 Hz). I am not sure if this really affects the channel, but it looks very different from all of the other channels. I am also wondering whether the channels below 20 Hz are useful at all, or whether they are just showing noise.
The microphone calibration has been something I have been trying to figure out for quite some time, but I recently found a value on the website that makes the EM172 microphones and has a value for their sensitivity. I determined the transfer factor from this sensitivity as 39.8107 mV/Pa, although I am not sure if all of the mics will be consistent with this. |
7062
|
Tue Jul 31 20:59:35 2012 |
Jamie | Update | CDS | fixing up MEDM snapshots | I've started to try to fix all the old non-working medm snapshots. I've made a new snapshot directory, and some new snapshot scripts to handle taking the snapshots, and view old ones.
Snapshots are now in: /opt/rtcds/caltech/c1/medm/snap
There is one main script: /opt/rtcds/caltech/c1/medm/snap/snapcommands. This is linked by:
- updatesnap: update a snapshot
- viewsnap: view most recent snapshot
- viewold: view old snapshots
These commands take either the path to the screen in question, or it's relative path to the medm directory (/opt/rtcds/caltech/c1/medm). The snapshots for a specific screen are stored in a directory specific to the screen, in a place relative to the snap directory that mimics the screens relative path to the overall medm directory. So for instance, the snap directory for:
/opt/rtcds/caltech/c1/medm/c1lsc/master/C1LSC_OVERVIEW.adl
is:
controls@rossa:~ 0$ find /opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/
/opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/
/opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/2012-08-01-02:21:34-UTC.png
/opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/2012-08-01-02:21:04-UTC.png
/opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/2012-08-01-02:21:23-UTC.png
/opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/2012-08-01-03:41:34-UTC.png
/opt/rtcds/caltech/c1/medm/snap/c1lsc/master/C1LSC_OVERVIEW/current.png
controls@rossa:~ 0$
The "current.png" is a link to the most recent snapshot, and is what you get when you "viewsnap".
Below is an example medm snippet of what could be used in screens to enable this functionality. I've fixed up a couple of the screens, but there are a lot more that need to be updated.
"shell command" {
object {
x=666
y=597
width=40
height=40
}
command[0] {
label="Settings and Procedures"
name="emacs"
args="./help/IFO_ALIGN.txt &"
}
command[1] {
label="View Snapshot"
name="/opt/rtcds/caltech/c1/medm/snap/viewsnap"
args="MISC/IFO_ALIGN.adl &"
}
command[2] {
label="View old snapshots"
name="/opt/rtcds/caltech/c1/medm/snap/viewold"
args="MISC/IFO_ALIGN.adl &"
}
command[3] {
label="Update Snapshot"
name="/opt/rtcds/caltech/c1/medm/snap/updatesnap"
args="MISC/IFO_ALIGN.adl &"
}
clr=14
bclr=30
}
|
7061
|
Tue Jul 31 19:34:55 2012 |
Koji | Update | STACIS | Open loop gains and block diagram | With your definition of the open loop gain, G=+1 is the condition to have singularity in a closed loop transfer function 1/(1-G).
But this is not the sole criteria of the loop stability.
Basically, the closed loop transfer function should not have "unphysical" pole.
For more about loop instability, you should refer stability criteria in literature such as Nyquist's stability criterion.
Both of the X and Z loops look unstable with the current gain. |
7060
|
Tue Jul 31 18:59:59 2012 |
Jamie | Update | CDS | updated medm paths for MISC (IFO,CDS,VIDEO), IFO alignment scripts updated accordingly | In an attempt to clean up the medm situation, I did a bunch of further rearrangement and cleanup. Instead of having c1ifo, I moved a bunch of stuff into a MISC directory, including all of the CDS, IFO, and VIDEO screens:
controls@rossa:~ 0$ ls -1 /opt/rtcds/caltech/c1/medm/MISC | grep -v _BAK
CDS_BIO_STATUS.adl
CDS_FE_STATUS.adl
CDS_IPC_ERR.adl
help
ifoalign
IFO_ALIGN.adl
ifoalign.orig
IFO_CONFIGURE.adl
IFO_CONFIGURE.txt
IFO_OVERVIEW.adl
IFO_OVERVIEW_AIDAN.adl
IFO_STATE.adl
snap
VIDEO.adl
controls@rossa:~ 0$
I updated the sitemap and the relevant screens accordingly.
I also updated the IFO_ALIGN script infrastructure a bit. The new IFO ALIGN location is /opt/rtcds/caltech/c1/medm/MISC/ifoalign. The scripts are now called simply:
/opt/rtcds/caltech/c1/medm/MISC/ifoalign/misalign_soft.csh
/opt/rtcds/caltech/c1/medm/MISC/ifoalign/restore_soft.csh
/opt/rtcds/caltech/c1/medm/MISC/ifoalign/save_soft.csh
These run Jenne's new soft restore stuff, and store burt snapshots for optic alignment in /opt/rtcds/caltech/c1/medm/MISC/ifoalign/burt.
This has all been checked into the svn. |
7059
|
Tue Jul 31 15:33:17 2012 |
Masha | Configuration | PEM | Gurlap Pin Map | I checked the connections specified in the old Gulap Pin Map and found that they do not correspond to the current values. I mapped out the current connections (in this case, the letter refers to the labeled pin on the mil/spec while the number refers to the pin on the 37 pin DSub, labeled consecutively):
A-1, B-2, C-3, D-4, E-5, F-6, G-7, H-Unused, J-8, K-unused, L-9, M-10, N -11, P-12, S-13, T-Unused, U-14, V-15, W-16, X-17, Y-18, Z-Unused, a-Unused, b-19, c-20, UnlabeledPin-Unused.
There are 20 pins in use of 26 total, which is good because that means Jenne and I can use the ~70m long 24 wire cable to make a new Gurlap 1 cable.

|
7058
|
Tue Jul 31 15:24:53 2012 |
Yaakov | Update | STACIS | Open loop gains and block diagram | First, a quick note on the PZT I thought I killed- it was most likely something in the high voltage amplifier that broke, since I put the amplifier in another STACIS with a working y-axis PZT and it still didn't work properly. Conclusion: something in the y-axis amplifier circuitry is broken, not the PZT itself.
Today I retook the open loop gains in the X and Z axes (Y axis out of commission for now, see above). With the loop open, I input a swept sine signal from 0.1 to 100 Hz, and measure the output of the geophones. This way all the transfer function that are present in the closed loop are present here as well: the transfer functions of the physical STACIS, the geophone pre-amplifier circuit, the high-voltage amplifier, and the PZT actuators.
Here is a block diagram showing what I am measuring, with the various transfer functions in blue boxes (the measurement is their product):

 


These open loop gains show there is gain of at least 10x from 2 to 80 Hz in the z-axis and 2 to 60 Hz in the x-axis. This is the region I was seeing isolation in when I switched to closed loop, which is consistent. These measurements were with all the pots in the geophone preamplifier set very low, so more gain (and thus isolation) is hypothetically possible if I find a way to stop the horizontal axes from becoming unstable at higher gains. There is unity gain at around 0.5 Hz and 100 Hz for the z-axis, but the phase is nowhere near 180 deg. at these points so there shouldn't be instability due to this. The peak at around 15 Hz is consistent with old records of the STACIS open loop gain. |
7057
|
Tue Jul 31 15:17:58 2012 |
Jamie | Update | CDS | c1ifo medm screens checked into CSD userapps svn | I moved the medm/c1ifo directory into the CDS userapps svn at cds/c1/medm/c1ifo, and then linked it back into the medm directory:
controls@rossa:~ 0$ ls -al /opt/rtcds/caltech/c1/medm/c1ifo
lrwxrwxrwx 1 controls controls 56 2012-07-31 11:53 /opt/rtcds/caltech/c1/medm/c1ifo -> /opt/rtcds/caltech/c1/userapps/release/cds/c1/medm/c1ifo
controls@rossa:~ 0$
I then committed whatever useful was in there. We need to remember to commit when we make changes. |
7056
|
Tue Jul 31 08:01:22 2012 |
steve | Update | VAC | cc1 switched |
Quote: |
Quote: |
Our cold cathode 423 gauges are 10 years old. They get insulated by age and show no ionization current. We should replace them at the next vent. I'm buying 4 at $317ea
|
We have two CC1 gauges at the pump spool. One is in vertical position and the spare is in horizontal. Today I switched the cable from vertical to horizontal CC1
This one is reading higher pressure. It is an old dirty gauge. It may trigger the RGA protection when it's reading goes above 1e-5 torr
The real pressure is 2e-6 torr
|
cc1h spikes closed VM1 last night. VM1 is opened. |
Attachment 1: cc1h1d.png
|
|
7055
|
Tue Jul 31 00:27:52 2012 |
Den | Update | PEM | trillium | We have a Trillium for several days from Vladimir. I've put seismometer inside the foam box on linolium. I was not able to level the seismometer on granite as this Trillium does not have level screws. Does anybody know where they are? Readout box stands on the foam box as seismometer cable is short (~2 meters).
Cables go to STS1 inputs (7-9) on ADC 3. |
7054
|
Mon Jul 30 22:52:51 2012 |
Yaakov | Update | STACIS | Geophone calibration | Tonight I looked at the signal from a geophone and accelerometer side by side, in order to see if they show the same ground motion and if the sensitivity factor I am using to convert from V to m/s is right. This is plotted below, along with the current estimates for accelerometer and geophone noise:


From this it is pretty clear that at least one of the sensitivity factors (V/m/s) I am using is wrong (the noise levels are much lower than the ground motion, so they can't account for the difference). I suspect it is the geophone one, because Wilcoxon provided these sensitivities for each individual accelerometer, but I was just using the number I found in online specs for the geophones.
The reason the online value is wrong is probably because of the value of the shunt resistor, a resistor that just goes across the top of the geophone (its purpose is to provide damping, by Lenz's Law). The specs assume a value of 380 Ohm, but I measured the one in the STACIS to be about 1.85 kOhm.
Assuming the accelerometer signal is correct, I multiplied the geophone signal by different factors to try to get an idea of what the true calibration factor is, and found that a value of 0.25 (m/s)/V gives decent agreement at higher frequencies (below 10 Hz the sensitivity drops off, according to the online specs). This is shown below:


Above, the geophone noise was recalculated with the new sensitivity and assuming that both geophones in the noise measurement had the same sensitivity. I took the transfer function of two geophones side by side to see if their gains were dramatically different; this plot is shown below. The coherence is only good for a small band, but looking at that band the gain is approximately unity, implying very roughly that the sensitivity of each is approximately the same. The lack of coherence is strange, and I'm not sure what the cause is. Even using the shaker near the geophones only improved the coherence slightly.
 
|
Attachment 2: sensor_comp2.bmp
|
7053
|
Mon Jul 30 17:24:45 2012 |
Yaakov | Update | STACIS | Revised sensor noise plot; dead PZT | The geophone noise in my last eLog was taken before any amplification of the signal, but what really matters is the noise after amplification, since it is this signal that the PZTs are driven by. The noise goes on to be amplified about 1000x before the geophone signal gets to the PZTs.
To obtain a more relevant noise plot, I multiplied the geophone noise by 1,000, the approximate gain of the amplification stage for the geophones (called the "compensator board", the semicircular board that sits toward the top of the STACIS). Below is a plot ( ) that shows the noise for the geophones after amplification and the accelerometer noise (with accelerometers set with a gain of 100x, their highest).

The actual signal from both these sensors has the right magnitude to drive the PZTs (whereas it was much too small in my last plot, where I looked at the sensors before any gain)- this means that for these sensors, both of which are outputting signals that are ready to provide feedback to the STACIS, the accelerometer noise is significantly lower than the geophone noise. This is good news, because it means that there could be a real advantage to using the accelerometers instead of the geophones.
In the process of investigating further advantages of the accelerometers, I believe I killed one of the horizontal PZTs in the spare STACIS (the eBay one). The story: I had that axis in closed loop, and I saw the STACIS shudder, heard a noise, and there was a faint acrid smell. I shut the STACIS off and took out the high voltage card at the base but couldn't find any visible signs of damage (like the current-limiting resistors which burn when a PZT shorts, acc. to old STACIS records). I then tried driving the PZTs with a sine wave, and there was no response in that axis (the other axes looked fine), which leads me to believe I either did unseen damage to the high voltage amplifier (for the y-axis) or killed the PZT itself. |
Attachment 1: sensor_noise.bmp
|
7052
|
Mon Jul 30 16:05:36 2012 |
Den | Update | digital noise | filter checker | We decided to write a script that will check online filters for digital noise. One method can be implemented using the following algorithm:
- calculate filter output using single precision
- calculate filter output using double precision and assume that it is precise
- find digital noise at the output of the filter when single precision is used
- extrapolate the result to the double precision filter dividing by 2D-S ~ 107, D - number of bits used in double precision mantissa, S - in single precision
Restriction: Single precision filter internal variables must be checked for overflows.
I applied this method to filtering a 1 Hz sine wave with a notch filter. Precise output should also be a 1 Hz wave => at other frequencies we see noise => digital noise spectrum should coincide with filter output. The plot shows the method worked out for this example.

Using this method I estimated digital noise of butter("LowPass", 2, 0.001) applied to white noise. Sampling frequency was 16 kHz.

|
7051
|
Mon Jul 30 15:49:16 2012 |
steve | Update | VAC | cc1 switched |
Quote: |
Our cold cathode 423 gauges are 10 years old. They get insulated by age and show no ionization current. We should replace them at the next vent. I'm buying 4 at $317ea
|
We have two CC1 gauges at the pump spool. One is in vertical position and the spare is in horizontal. Today I switched the cable from vertical to horizontal CC1
This one is reading higher pressure. It is an old dirty gauge. It may trigger the RGA protection when it's reading goes above 1e-5 torr
The real pressure is 2e-6 torr |
Attachment 1: cc1changedfVtH.png
|
|
7050
|
Mon Jul 30 14:24:25 2012 |
Den | Update | digital noise | biquad key is working |
Quote: |
What is "DQF"? Is that the biquad? And what is the difference between DF1 and DF2? Why don't you just write out the name, so it's more clear.
|
DQF - biquad form
DF1 - direct form 1
DF2 - direct form 2
LNF - low-noise form
The difference between them is described in Matt's slides G0900928-v1. I think, LNF coefficients are incorrect in the presentation
|
7049
|
Mon Jul 30 12:38:45 2012 |
Jamie | Update | CDS | Move to RCG 2.5 tag release | I moved the RCG to the advLigoRTS-2.5 tag:
controls@c1iscey ~ 0$ ls -al /opt/rtcds/rtscore/release
lrwxrwxrwx 1 controls 1001 19 Jul 30 12:02 /opt/rtcds/rtscore/release -> tags/advLigoRTS-2.5
controls@c1iscey ~ 0$
There are only very minor differences between what we were running on the the 2.5 branch. I have NOT rebuilt all the models yet.
I was hoping that there was something in the tagged release that might fix this hard-crash-on-filter-load issue that we're seeing in the c1tst model. It didn't. Still have no idea what's going on there. |
7048
|
Mon Jul 30 10:05:29 2012 |
Jenne | Update | PSL | PMC is still not fixed |
Quote: |
The PMC was locking right the way, but it's transmission would not go up. Finally I get it back up by moving the "sticky" DC Gain slider up and down a few times.
|
The FSS was -2.9, and the PMC won't lock happily unless you bring this back to 0. The symptom that this is happening is that the PMC reflection camera is totally saturated, but the PMC still looks like it's locked on 00. |
7047
|
Mon Jul 30 09:00:18 2012 |
steve | Update | PSL | PMC is still not fixed | The PMC was locking right the way, but it's transmission would not go up. Finally I get it back up by moving the "sticky" DC Gain slider up and down a few times. |
Attachment 1: pmcA.png
|
|
Attachment 2: pmcB.png
|
|
7046
|
Fri Jul 27 16:32:17 2012 |
Jamie | Update | CDS | RCG bug exposed by simple c1tst model | As Den mentioned in 7043, attempting to run the c1tst model was causing the entire c1iscey machine to crash. Alex came over this morning and we spend a couple of hours trying to debug what was going on.
c1tst is the simplest possible model you can have: 1 ADC and 2 filter modules. It compiles just fine, but when you tried to load it the machine would completely freeze.
We eventually tracked this down to a non-empty filter file for one of the filter modules. It turns out that the model was crashing when it attempted to load the filter file. Once we completely deleted all the filters in the module, the model would run. But then if you added back a filter to the filter file and tried to "load coefficients", the model/machine would immediately crash again.
So it has something to do with the loading of the filter coefficients from the filter file. We tried different filters and it didn't seem to make a difference. Alex thought it might have something to do with zeros in some of the second-order sections, but that wasn't it either.
There's speculation that it might be related to a very similar bug that Joe reported at LLO a month ago: https://bugzilla.ligo-wa.caltech.edu/bugzilla/show_bug.cgi?id=398
Things we tried, none of which worked:
- adding a DAC
- turning on/off biquad
- disabling the float denormalization fix
This is a real mystery. Alex and I are continuing to investigate. |
7045
|
Fri Jul 27 14:30:49 2012 |
Jamie | Update | digital noise | biquad key is working | What is "DQF"? Is that the biquad? And what is the difference between DF1 and DF2? Why don't you just write out the name, so it's more clear. |
7044
|
Fri Jul 27 14:28:36 2012 |
steve | Update | VAC | cold cathode gauges | Our cold cathode 423 gauges are 10 years old. They get insulated by age and show no ionization current. We should replace them at the next vent. I'm buying 4 at $317ea
|
Attachment 1: cc_gauges.png
|
|
7043
|
Fri Jul 27 14:27:14 2012 |
Jamie | Update | CDS | new c1tst model for testing RCG code |
Quote: |
I wanted to test biquad form in this model. I added biquad=1 flag to cdsParameters, compiled, installed and restarted it. After that c1iscey suspended.
The same thing as we had several month ago
controls@c1iscey /opt/rtcds/caltech/c1/target/c1tst/c1tstepics 0$ cat iocC1.log
Starting iocInit
iocRun: All initialization complete
sh: iniChk.pl: command not found
Failed to load DAQ configuration file
|
I have fixed the iniChk.pl issue (which actually fixed a separate model startup-on-boot issue that we had been having). However, that is completely unrelated to the system freeze. I'll discuss that in a separate post. |
7042
|
Thu Jul 26 21:31:44 2012 |
Den | Update | digital noise | online biquad works |
Quote: |
Still I do not like huge (2n+1) harmonics in the output of the biquad filter, I do not get them in the simulations. They are absent in the time series as well. So this is not a psd-estimation effect.
|
Excitation generator created these harmonics. When I applied low-pass butterworth filter, I've got the result of online filtering close to simulations. On the second graph blue is biquad filter output spectrum, red corresponds to DF2. 1 Hz sin wave was filtered with a notch filter of Q=100, depth=300 at 1 Hz.

|
7041
|
Thu Jul 26 17:39:49 2012 |
Den | Update | digital noise | biquad key is working | I've filtered a 1 Hz sin wave excitation with a notch filter inside c1sus and c1rfm models. The biquad key is switched on in the last one, c1sus uses DF2. The results are indeed different.

Still I do not like huge (2n+1) harmonics in the output of the biquad filter, I do not get them in the simulations. They are absent in the time series as well. So this is not a psd-estimation effect.
 
|
7040
|
Thu Jul 26 16:08:59 2012 |
Yaakov | Update | STACIS | Noise plot update | I have a tentative noise plot for the STACIS that includes accelerometer noise, geophone noise, and platform motion with the STACIS off. (Accelerometer noise was measured for the VEL and NONE setting, which are settings on the accelerometer box which make the accelerometer signal correspond to velocity and acceleration, respectively. ) I'm focusing on sensor noise because this is the variable I am looking at changing, and knowing how the sensor noise translates into STACIS platform motion is therefore important.


The accelerometer and geophone noise I determined as described in my last eLog (http://nodus.ligo.caltech.edu:8080/40m/7027) Along the way I found out several things of importance:
1) Horizontal geophones are ONLY horizontal geophones. This is obvious in retrospect, because the springs supporting the magnet inside must be oriented based on vertical/horizontal operation.
2) The geophones in the STACIS are GS-11D (geospace), with a sensitivity of 32 V/m/s (compared to about 3.9 V/m/s for the accelerometers in VEL setting).
3) The accelerometers have different V/m/s sensitivities. I noticed the voltage output of one was consistently higher than the other, leading to very high noise estimates, but then Jenne showed me the actual calibration factors of the individual accelerometers which differed by as much as 0.4 V/m/s (a few percent difference). Taking this into account made the noise plots much more reasonable, but variations in calibration could still create some error.
The accelerometer noise agrees fairly well with the specs on the Wilcoxon page (http://www.wilcoxon.com/prodpdf/731A-P31%2098079a1.pdf). The geophone noise seems surprisingly low; it is even better than the geophone below about 4 Hz.
To see how this noise translates into actual platform motion, I took PSDs of the STACIS while it was off, on with accelerometer feedback, and on with geophone feedback (the "off" PSD is in the above noise plot). Using this data I'm working on estimating a transfer function that shows how the sensor noise translates to motion so I can come up with a sensor noise budget.


This shows that the geophones are actually doing a better job of isolating than the accelerometers, which is not surprising if the noise plot is accurate and the geophones are actually lower noise. It must be noted, though, that the noise plot was for the horizontal geophones whereas the plot above is for the vertical axis which may have a different noise level. Also, the vertical have some extra isolation by being enclosed in a metal stack with rubber padding at its base.
The problem with the STACIS in the past was the differential motion it introduced. I think this might be because the horizontal isolation was not uniform for each chamber. This means that even what would be symmetric motion (no differential length change) would be translated to differential motion because one end is more fixed than the other. Having accelerometers or better-padded geophones (maybe like the vertical geophones) in the STACIS ought to help with this by making the horizontal isolation more consistent and thus reducing differential motion. So the key may not be the geophone noise as much as varying geophone sensitivities or variation in how well they're mounted in the STACIS. I can test this by swapping out the horizontal geophones with other spares, changing the tightness of the mount, and seeing if either of these changes the horizontal isolation significantly, since these are factors that may differ from unit to unit.
I will also compare horizontal closed loop response with geophone vs. accelerometer feedback to see if the geophones are only doing a good job in the above plot because of their extra padding (the vertical stack). |
|