ID |
Date |
Author |
Type |
Category |
Subject |
6741
|
Fri Jun 1 10:00:03 2012 |
steve | Omnistructure | General | 40m Wireless Network |
Quote: |
Mike Pedraza came by today to install a new wireless network router configured for the 40m lab network. It has a 'secret' SSID i.e. not meant for public use outside the lab. You can look up the password and network name on the rack. Pictures below show the location of the labels.

|
Mike P swapped in a new network router Linksys E1000 |
6740
|
Fri Jun 1 09:50:50 2012 |
Jamie | Update | Computers | c1sus and c1iscex - bad fb connections |
Quote: |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better.
|
This is at least partially related to the mx_stream issue I reported previously. I restarted mx_stream on c1iscex and that cleared up the models on that machine.
Something else is happening with c1sus. Restarting mx_stream on c1sus didn't help. I'll try to fix it when I get over there later. |
6739
|
Fri Jun 1 08:17:47 2012 |
steve | Update | IOO | PMC trends |
Quote: |
IOO Angle & IOO Position QPDs centered.
|
PMC trend of 400 and 1200 days
The Innolight 2W based PSL- IOO was implemented in the ~ summer of 2010 |
Attachment 1: PMC400d.png
|
|
Attachment 2: PMC1200d.png
|
|
6738
|
Fri Jun 1 08:01:46 2012 |
steve | Update | Computers | c1sus and c1iscex are down |
Quote: |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better.
|
|
Attachment 1: compdown.png
|
|
6737
|
Fri Jun 1 02:33:40 2012 |
Jenne | Update | Computers | c1sus and c1iscex - bad fb connections |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better. |
6736
|
Fri Jun 1 02:13:00 2012 |
Jenne | Update | Green Locking | Attempt at Ygreen beat - failed |
[Yuta, Jenne]
We tried to find the Ygreen beat note, with no success yet. We calculate from Bryan's formula that the Yend laser should be ~34.68C. But Katrin has an elog saying that she was looking around 19C. I don't know why the discrepancy, but maybe this is part of our problem? Kiwamu elog-responded that the epics output had to be high (~9V) when the temp was 19C. So maybe we need a smaller offset setting in the slow servo with the 34C temperature?
We set the "T+" on the Ygreen laser controller to 34.68C using the dial, and then tried a few large steps with the offset in the Ygreen slow servo. The idea was to see if we could swing past the beat, so we would know vaguely where it was. But we never saw a resonance on the spectrum analyzer, even with a "hold max" trace.
We confirmed that there is signal going to the SLOW input of the laser controller's front panel. Yuta watched a voltmeter while I changed the epics value, and we successfully changed the signal. However, after plugging the SLOW cable back in, we noticed that no matter what we set the epics value to, we don't see any temperature change reported on the front panel display. There is something in the manual( according to Katrin) that the "LT" display is not accurate when a cable is plugged in. But none of the display values changed. I think there is a measured temp output on the back that Bryan mentioned that we could use to see if something is really changing inside.
Anyhow, no beatnote found yet tonight. We confirmed before starting that the alignment onto the beat PD was good, so that's not the problem. |
6735
|
Thu May 31 23:53:00 2012 |
Jenne | Update | LSC | LSC trigger update |
I modified the lsc model (after Jamie finished) to use a new triggering scheme. It HAS NOT yet been compiled and tested, since it's way past time for us to start beatnote-ing. I will compile, test, debug, etc. tomorrow. Don't compile the LSC model tonight.
Now we also have (assuming no bugs.....) triggering capability for the filter modules in the filter banks. Yay! Testing, etc will commence tomorrow. |
6734
|
Thu May 31 22:13:08 2012 |
Jamie | Update | CDS | c1lsc: added remaining SHMEM senders for ERR and CTRL, c1oaf model updated appropriately |
All the ERR and CTRL outputs in c1lsc now go to SHMEM senders. I renamed the the CTRL output SHMEM senders to be more generic, since they aren't specifically for OAF anymore. See attached image from c1lsc.
c1oaf was updated so that SHMEM receivers pointed to the newly renamed senders.
c1lsc and c1oaf were rebuilt, installed, and restarted and are now running. |
Attachment 1: lsc-shmem-out.png
|
|
6733
|
Thu May 31 17:47:25 2012 |
Suresh | Omnistructure | General | 40m Wireless Network |
Mike Pedraza came by today to install a new wireless network router configured for the 40m lab network. It has a 'secret' SSID i.e. not meant for public use outside the lab. You can look up the password and network name on the rack. Pictures below show the location of the labels.

|
6732
|
Thu May 31 16:54:12 2012 |
Jenne | Update | Green Locking | Links to old elogs for green beatnote laser temps |
Because I keep taking a long time to search for these, since I can't remember the keywords in the different entries, here are the links:
elog 3759 : Green X end aux laser temperature setting vs. PSL laser temperature setting
elog 4439 : Green Y end aux laser temperature setting vs. PSL laser temperature setting
More words: beat note, doubling, second harmonic.
Relevant results:
T_Xend = 8.31 + 0.9293*T_PSL
T_Yend = 6.9825 + 0.87326*T_PSL
Also, C1:GCY-SLOW_SERVO2_OFFSET was 29725 (twenty nine thousand seven hundred twenty five) cts when we sat down to start today.
C1:GCX-SLOW_SERVO2_OFFSET was 80 (eighty) cts when we sat down to start today. Why the offsets are so different, I don't know. But I was able to find the X green beatnote with this small number offset, so it is approximately correct. |
6731
|
Thu May 31 16:19:07 2012 |
yuta | Update | Green Locking | temperature setting for PSL doubling crystal |
I fixed the temperature control of the oven for the PSL doubling crystal.
The PID settings were not good, and also, TC200 was beging DETUNED. So, I activated TUNE function and adjusted PID settings.
I'm not sure what the DETUNE function is for. The manual can be found here;
http://www.thorlabs.com/thorproduct.cfm?partnumber=TC200
Current settings for Thorlabs TC200 are (Red ones are what I changed from the previous setting);
parameters |
Xend |
Yend |
PSL |
TEMP SET (deg C) |
37.5 |
35.7 |
36.9 |
P |
250 |
250 |
250 |
I |
60 |
60 |
200 (was 117) |
D |
25 |
25 |
40 (was 19) |
(DE)TUNE on? |
TUNE |
TUNE |
TUNE (was DETUNE) |
TMAX (deg C) |
200 |
200 |
170 |
PMAX (Watts) |
18 |
18 |
18 |
temperature sensor |
PTC100 |
PTC100 |
PTC100 |
|
6730
|
Thu May 31 11:38:19 2012 |
Den | Update | PEM | isolation system |
I've put Guralps into the Steve's 2 box isolation system. Noise got better, coherence between 2 seismometers improved. We still need better performance. Probably, one device is noisy and we can not determine which one using these 2 seismometers. We need more seismometers. Sadly, STS-2 readout box is not working.

|
6729
|
Thu May 31 11:02:14 2012 |
steve | Update | Locking | ETMX 1064 trans camera |
Quote: |
Quote: |
...will be helpful for acquiring lock after the vent. We should install a camera at ETMX.
|
Do that.
|
Jenne and Steve
Sony CCD in place needs alignment and ND filter |
6728
|
Thu May 31 10:31:19 2012 |
Jamie | Update | IOO | MC beam spot oscillation |
Quote: |
This is a common occurrence when diagnostic scripts are written without the ability to handle exceptions (e.g. ctrl-c, terminal gets closed, etc.).
The first thing to do is make sure that the "new" script you are writing doesn't already exist (hint: look in the old scripts directory).
If you are writing a script that touches things in the interferometer, it must always return the settings to the initial state on abnormal termination:
http://linuxdevcenter.com/pub/a/linux/lpt/44_12.html
|
This is very good advice. However, "trap" is bash-specific. tcsh has a different method that uses a function called "onint". Here's a description of the difference.
A couple notes about bash traps:
- You can give a name instead of a number for the signal. So instead of
trap 'do stuff' 1 you can say trap 'do stuff' SIGHUP
- The easiest signal to use is EXIT, which covers all your bases (ie. anything that would cause the script to exit prematurely.
- You can define a function that gets executed in the trap
So the easiest way to use it is something like the following:
#!/bin/bash # define cleanup function function cleanup { # do cleanup stuff, like reset EPICS records to defaults .... } # set the trap on EXIT trap cleanup EXIT # the rest of your script below here
...
|
6727
|
Thu May 31 04:03:17 2012 |
yuta | Update | IOO | script for MC beam spot measurement |
I wrote a wrapping script for measuring MC beam spot. We had to run several scripts for the measurement (see elog #6688), but now, you only need to run /opt/rtcds/caltech/c1/scripts/ASS/MC/mcassMCdecenter.
The measured data file will be stored in /opt/rtcds/caltech/c1/scripts/ASS/MC/dataMCdecenter/ directory, with a timestamp.
The calculated beam spot position data will be logged in /opt/rtcds/caltech/c1/scripts/ASS/MC/dataMCdecenter/logMCdecenter.txt file.
I had to edit sensemcass.m file, in order to write the result into the log file. In this way, we can keep track of the beam displacement.
Currently, the calculation script is written in the MATLAB file(sensemcass.m), which isn't very nice.
To run a MATLAB file from the command line, you have to write something like this;
matlab -nodesktop -nosplash -r "sensemcass('./dataMCdecenter/MCdecenter201205210258.dat')"
|
6726
|
Thu May 31 02:27:24 2012 |
yuta | Update | IOO | script for reliefing MC WFS |
I wrote a simple script for reliefing MC WFS servo. The script is located at /opt/rtcds/caltech/c1/scripts/MC/reliefMCWFS.
It simply uses ezcaservo to minimize the offset of the WFS feedback signal using MC alignment sliders.
ezcaservo -r C1:SUS-MC${optic}_ASC${dof}_OUT16 -s 0 -g 0.0001 -t 10 C1:SUS-MC${optic}_${dof}_COMM
I put "MC WFS relief" button on the WFS medm screen (/opt/rtcds/caltech/c1/medm/c1ioo/master/C1IOO_WFS_MASTER.adl).
|
6725
|
Thu May 31 01:36:17 2012 |
yuta | Update | Green Locking | GREEN_TRX/GREEN_TRY PDs |
I did the cabling for monitoring DC transmission of the green beam from the end table.
The two PDs are called GREEN TRX and GREEN TRY, and the channel names are C1:GCV-GREEN_TRX and C1:GCV-GREEN_TRY.
The two signal from the PDs go to the ADC_0 card of the c1ioo computer.
Now, C1:GCV-GREEN_TRX/Y are actually connected to the respective PDs, but green beams are not hitting on the PD. We need two pickoff mirrors. |
6724
|
Thu May 31 01:27:16 2012 |
yuta | Update | Green Locking | PSL and Y arm green beams aligned |
[Jenne, Yuta]
We aligned the PSL green optics so that the PSL green beam and Y arm green beam interfere. 2 beams are now hitting the Y arm beat PD. The DC level from the beat PD is about 13 mV.
We didn't try to see the beat signal for today, because the temperature of the doubling crystal seemed funny. We need to look into it tommorow.
Currently, the temperature control is enabled and the set point is 36.9 deg C, but the temperature is stuck at 33.0 deg C. |
6723
|
Thu May 31 01:20:41 2012 |
Jenne | Update | ASS | ASS filter outputs are non-zero with no input |
I was looking a little at ASS, while Yuta was doing some Green transmitted DC PD work, and I find that the output of some filters is totally insane with no deliberate input or excitation signals.
Note in the figure that the filter (which is a 2nd order butter bandpass in the C1:ASS-LOCKIN29_SIG filter bank) is ringing a lot - this needs fixing. But, more disconcertingly, sometimes (not every time) the arm flashes, the input to the filter bank gets a ~1 sample long spike that is ~9,000,000 counts. 9 million is a lot of counts. This is then making the filter go crazy.
Any ideas on how this can happen, and how we can stop / fix it? It's certainly a CDS issue, but I'm not sure where or how. |
Attachment 1: ASS_Yarm_crazyOutputs_30May2012.png
|
|
6722
|
Thu May 31 00:56:13 2012 |
Jamie | Metaphysics | Computers | Please remember to check in code changes |
I know it's really hard to remember, but our future selves will thank us dearly if we remember to commit all of our code changes to the svn with nice log messages. At the moment there's a LOT of modified stuff in the userapps working directory that needs to be committed:
controls@pianosa:/opt/rtcds/userapps/release 0$ svn status | grep '^M'
M cds/c1/models/c1rfm.mdl
M sus/c1/medm/templates/SUS_SINGLE.adl
M sus/c1/models/c1mcs.mdl
M sus/c1/models/c1sus.mdl
M sus/c1/models/c1scx.mdl
M sus/c1/models/c1scy.mdl
M isc/c1/models/c1pem.mdl
M isc/c1/models/c1ioo.mdl
M isc/c1/models/ADAPT_XFCODE_MCL.c
M isc/c1/models/c1oaf.mdl
M isc/c1/models/c1gcv.mdl
M isc/common/medm/OAF_OVERVIEW.adl
M isc/common/medm/OAF_DOF_BLRMS.adl
M isc/common/medm/OAF_OVERVIEW_BAK.adl
M isc/common/medm/OAF_ADAPTATION_MICH.adl
controls@pianosa:/opt/rtcds/userapps/release 0$
This doesn't even include things that haven't even been added yet. It doesn't take much time. Just copy and paste what you elog about the changes. |
6721
|
Wed May 30 22:51:32 2012 |
Den | Update | PEM | guralp isolation box |
When I've put Guralps inside the isolation box, the signal from seismometers increased and was out of AA board range. I've reduced the gain of the readout box by a factor of 2. Now R2 for channels 1-6 is (2000, 1050, 1050, 2000, 1050, 1050) Ohm.
The signal increased in the frequency range 30-50 Hz. Guralp noise become better. That's good. However, it is still worse then in the manual.
As Yuta is dancing on the isolation box, Guralp signal is most time out of the AA board range. So I calculated the noise based on 5 min data. This may be enough, but I'll repeat the experiment later with 30 min data.

|
6720
|
Wed May 30 22:04:13 2012 |
Jenne | Bureaucracy | General | 40m Action Items |
.....including:
fix Q of Vio2 filter in SUS. - JENNE
Switch power source for beatnote PD's amplifiers from temporary power supplies under PSL table to permanent taking the power from a rack. |
6719
|
Wed May 30 20:12:15 2012 |
rana | Update | IOO | MC beam spot oscillation |
This is a common occurrence when diagnostic scripts are written without the ability to handle exceptions (e.g. ctrl-c, terminal gets closed, etc.).
The first thing to do is make sure that the "new" script you are writing doesn't already exist (hint: look in the old scripts directory).
If you are writing a script that touches things in the interferometer, it must always return the settings to the initial state on abnormal termination:
http://linuxdevcenter.com/pub/a/linux/lpt/44_12.html |
6718
|
Wed May 30 19:27:38 2012 |
yuta | Update | IOO | MC beam spot oscillation |
[Koji, Yuta]
We found that C1:SUS-MC{1,2,3}_TO_COIL_3_4_GAIN was somehow changed to -1, and feedback signal for SIDE was fedback to LLCOIL, which is apparently not correct.
We checked the snapshots on May 25 and confirmed that it was used to be 0, so we fixed it.
We suspect that it happened during the beam spot measurement, because the measurement changes the TO_COIL matrix gains.
Now, we don't see any MC beam spot oscillation.
Quote: |
[Koji, Suresh, Jenne, Yuta]
Background:
We noticed that the beam spots on MC mirrors are oscillating in ~ 1 Hz yesterday. It means MC mirrors are actually oscillating. This was observable even if the WFS servo is off.
|
|
6717
|
Wed May 30 18:16:44 2012 |
Jamie | Update | LSC | skeleton of new c1cal calibration model created |
[Jamie, Xavi Siemens, Chris Pankow]
We built the skeleton of a new calibration model for the LSC degrees of freedom. I named it "c1cal". It will run on the c1lsc FE machine, in CPU slot 4, and has been given DCUID 50.
Right now there's not much in the model, just inputs for DARM_ERR and DARM_CTRL, filters for each input, and the sum of the two channels that is h(t).
Tomorrow we'll extract all the needed signals from c1lsc, and see if we can generate something resembling a calibrated signal for one of the IFO DOFs.
|
6716
|
Wed May 30 18:08:40 2012 |
Jamie | Update | LSC | c1lsc: add error point pick-offs, moved ctrl pick-offs after feedforward |
I made some modifications to the c1lsc model in order to extract both the error and control signals.
I added pick-offs for the error signals right before IFO DOF filter modules. These are then sent with GOTOs to outputs.
I also modified things on the control side. The OAF stuff was picking off control signals before feedforward in/outs. After discussing with Jenne we decided that it would make sense for the OAF to be looking at the control signals after feedforward. It also makes sense to define the control signal after the feedforward. These control signals are then sent with GOTOs to another set of outputs.
Finally, I moved the triggers to after the control signal pickoffs, and right before the output matrix. The final chain looks like (see attachment):
input matrix --> power norm --> ERR pickoff --> DOF filters --> FF out --> FF in --> CTRL pickoff --> trigger --> output matrix
The error pickoff outputs in the top level of the model are left terminated for the moment. Eventually I will be hooking these into the new c1cal calibration model.
The model was recompiled, installed, and restarted. Everything came up fine. |
Attachment 1: LSCchain.png
|
|
6715
|
Wed May 30 15:51:22 2012 |
yuta | Update | IOO | MC beam spot oscillation |
[Koji, Suresh, Jenne, Yuta]
Background:
We noticed that the beam spots on MC mirrors are oscillating in ~ 1 Hz yesterday. It means MC mirrors are actually oscillating. This was observable even if the WFS servo is off.
What we did:
1. By measuring the spectra of OSEM sensor outputs, we found that MC3 is the one that is oscillating.
2. Oscillation at ~ 1 Hz only happened when the local damping using OSEMs are on (see Attachment 1; REF is when the damping is on).
3. We found that this oscillation came from insufficiency in phase margin in SUSPOS loop. So, we increased the gain, C1:SUS-MC3_SUSPOS_GAIN, from 95 to 200. It helped a little, but oscillation is still there.
4. We measured openloop transferfunctions of SUSPOS, SUSPIT, SUSYAW, SUSSIDE loop, and concluded that diagonalization some how went wrong. The amplitude of the oscillation (peak height in the OSEM spectra) changed by pushing the MC SUS connectors.
Plan:
- Fix the connectors so that we don't have to push them any more.
- Redo the diagonalization of the MC suspensions. |
Attachment 1: specMC3_onoff_localdamping.pdf
|
|
6714
|
Wed May 30 13:24:08 2012 |
Jenne | Update | Locking | Yarm error spectra |
Quote: |
The ~16Hz bounce mode of some optic is showing up in the Yarm error signal.
MC is kind of 'windy' looking, so maybe it's from that? (Yuta's guess).
We need to make sure that the SUS damping and oplev paths both have notches at the correct bounce mode, not the old, old MOS frequency. If that doesn't work, may need to put a resgain in Yarm path.
|
Made the Bounce notch in the BounceRoll filter (ITMY OLPIT, ITMY OLYAW) wider, so it actually spans the peak we see in the error spectra. When we next lock the arm later today, I'll retake this spectra to see if the ETMY oplev fix (Koji, Yuta) and this notch fix both helped. |
6713
|
Wed May 30 01:35:15 2012 |
yuta | Update | Green Locking | aligned Y arm green beam |
[Jenne, Yuta]
We aligned the Y arm for IR (C1:LSC-TRY_OUT is now ~ 0.9), and aligned the green beam from the ETMY table. The Y arm green is now resonating in TEM00 mode, but we need some monitors (green trans or green refl) to maximize the coupling.
We noticed that the MC beam spot are oscillating at ~ 1 Hz, mostly in YAW. This wasn't observable before the PMC realignment (elog #6708). We should find out why and fix it. |
6712
|
Tue May 29 22:48:37 2012 |
Den | Update | PEM | Guralp noise |
I've checked whether the Guralp noise that we see comes not from seismometer but from ADC or readout box. I did 2 separate measurements . First, I've split 1 signal from Guralp into 2 before the input to AA board and subtracted one from another using Wiener filter. Second, I've connected inputs of channels 1 and 4 of the seismometer readout box and put the signal from seismometer to channel 1.

The plot shows that ADC and readout box do not contribute too much to the Guralp noise. |
6711
|
Tue May 29 21:50:21 2012 |
Jenne | Update | Locking | Yarm error spectra |
The ~16Hz bounce mode of some optic is showing up in the Yarm error signal.
MC is kind of 'windy' looking, so maybe it's from that? (Yuta's guess).
We need to make sure that the SUS damping and oplev paths both have notches at the correct bounce mode, not the old, old MOS frequency. If that doesn't work, may need to put a resgain in Yarm path. |
Attachment 1: LSC_POY_11_I_ERR_29May2012.pdf
|
|
6710
|
Tue May 29 21:34:08 2012 |
Jenne | Update | SUS | ETMY oplev spot size reduced |
Quote: |
Quote: |
Quote: |
The typical sign of a dying gas laser is that it glows for a few minutes only. The power supplies are fine.
Two new JDS - Uniphase 1103P lasers ( NT64-104 ) arriving on Monday, May 21
|
Yesterday I swapped in new He/Ne laser with output power 3.5 mW The return spot on qpd is large ~6mm in diameter and 20,500 counts
The spot size reduction require similar layout as ETMX oplev.
|
The oplev path is relayed and the spot size on the qpd is reduced. I still have to clean up and replace "Miki Mouse" lens holder.
|
Flipped the sign on the ETMY oplev servo gain, since it was wrong. (It was "-" for both, now it is "+" for both) |
6709
|
Tue May 29 21:05:30 2012 |
yuta | Update | IOO | PMC, MC alignment are shit |
Quote: |
[Keiko, Jenne]
PMC aligned. Suresh is fixing the measure MC spot positions script, then we'll remeasure MC spot positions.
|
[Suresh, Jenne, Yuta]
We measured the MC spot positions twice tonight. Procedure for measuring them is in elog #6688.
The results were;
spot positions in mm (MC1,2,3 pit MC1,2,3 yaw):
3.3359 3.9595 2.3171 -7.7424 -0.8406 6.4884
spot positions in mm (MC1,2,3 pit MC1,2,3 yaw):
3.2681 4.0052 2.2808 -7.3965 -0.7624 7.1302
The spot moved by about 0.5 mm since May 25, but we concluded that this displacement is negligible and difficult to be fixed by aligning PSL beam.
We'll align Y arm and X arm next. |
6708
|
Tue May 29 19:50:01 2012 |
Jenne | Update | IOO | PMC, MC alignment are shit |
Quote: |
The followings are a kind of daily check. Do this without any notice:
- Align PMC.
Quote: |
[Yuta, Jenne]
PMC and MC alignment are both shit, although with the WFS on, the MC is pretty good. We're leaving it for now, so that (a) we don't mess up Koji's work, and (b) we can work on the Xarm. Steve is doing Yarm oplev stuff, so we'll do Yarm later.
|
|
[Keiko, Jenne]
PMC aligned. Suresh is fixing the measure MC spot positions script, then we'll remeasure MC spot positions. |
6707
|
Tue May 29 17:40:45 2012 |
Jenne | Update | IOO | PMC, MC alignment are shit |
Quote: |
[Yuta, Jenne]
PMC and MC alignment are both shit, although with the WFS on, the MC is pretty good. We're leaving it for now, so that (a) we don't mess up Koji's work, and (b) we can work on the Xarm. Steve is doing Yarm oplev stuff, so we'll do Yarm later.
|
[Yuta, Jenne, Suresh]
We pushed on the MC SUS connectors at the back of the rack, and that helped bring MC3 back to where it should be. Then we looked at MC RFPD DC, and adjusted the optics with the WFS off, so that the refl is ~0.56. Then when we turn the WFS on, the alignment doesn't really change, so we have offloaded the WFS.
Now we're measuring the spot positions to check where the MC is. Then we'll align the arms, and align the green to the arms. |
6706
|
Tue May 29 15:55:22 2012 |
steve | Update | SUS | ETMY oplev spot size reduced |
Quote: |
Quote: |
The typical sign of a dying gas laser is that it glows for a few minutes only. The power supplies are fine.
Two new JDS - Uniphase 1103P lasers ( NT64-104 ) arriving on Monday, May 21
|
Yesterday I swapped in new He/Ne laser with output power 3.5 mW The return spot on qpd is large ~6mm in diameter and 20,500 counts
The spot size reduction require similar layout as ETMX oplev.
|
The oplev path is relayed and the spot size on the qpd is reduced. I still have to clean up and replace "Miki Mouse" lens holder.
There was no IP-ANG coming out of the chamber at this time! |
Attachment 1: ETMYoplev.jpg
|
|
Attachment 2: IMG_1243.JPG
|
|
6705
|
Tue May 29 15:49:02 2012 |
Koji | Update | Locking | ETMX trans camera |
Quote: |
...will be helpful for acquiring lock after the vent. We should install a camera at ETMX.
|
Do that. |
6704
|
Tue May 29 15:48:31 2012 |
Koji | Update | IOO | PMC, MC alignment are shit |
The followings are a kind of daily check. Do this without any notice:
- Align PMC.
- Check MC spot position with the script (where is it located?). Ignore MC2 result as it can be arbitrary set.
- If the MC1/MC3 spots have moved it means that the PSL beam has moved. If the beam has moved, we should have some discussion what we should do.
- If the spot positions are about the same as before, align the MC mirrors. This should be done by nulling the WFS feedback. (Someone should make a simple script for this WFS offloading.)
------------
Then, start locking both arms
Quote: |
[Yuta, Jenne]
PMC and MC alignment are both shit, although with the WFS on, the MC is pretty good. We're leaving it for now, so that (a) we don't mess up Koji's work, and (b) we can work on the Xarm. Steve is doing Yarm oplev stuff, so we'll do Yarm later.
|
|
6703
|
Tue May 29 15:29:16 2012 |
Jamie | Update | Computers | latest pynds installed on all new control room machines |
The DASWG lscsoft package repositories have a lot of useful analysis software. It is all maintained for Debian "sqeeze", but it's mostly installable without modification on Ubuntu 10.04 "lucid" (which is based on Debian squeeze). Basically the only thing that needs to access the lscsoft repositories is to add the following repository file:
controls@rossa:~ 0$ cat /etc/apt/sources.list.d/lscsoft.list
deb http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze contrib
deb-src http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze contrib
deb http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze-proposed contrib
deb-src http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze-proposed contrib
controls@rossa:~ 0$
A simple "apt-get update" then makes all the lscsoft packages available.
lscsoft includes the nds2 client packages (nds2-client-lib) and pynds (python-pynds). Unfortunately the python-pynds debian squeeze package currently depends on libboost-python1.42, which is not available in Ubuntu lucid. Fortunately, pynds itself does not require the latest version and can use what's in lucid. I therefore rebuilt the pynds package on one of the control room machines:
$ apt-get install dpkg-dev devscripts debhelper # these are packages needed to build a debian/ubuntu package
$ apt-get source python-pynds # this downloads the source of the package, and prepares it for a package build
$ cd python-pynds-0.7
$ debuild -uc -us # this actually builds the package
$ ls -al ../python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
-rw-r--r-- 1 controls controls 69210 2012-05-29 11:57 python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
I then copied the package into a common place:
/ligo/apps/debs/python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
I then installed it on all the control room machines as such:
$ sudo apt-get install libboost-python1.40.0 nds2-client-lib python-numpy # these are the dependencies of python-pynds
$ sudo dpkg -i /ligo/apps/debs/python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
I did this on all the control room machines.
It looks like the next version of pynds won't require us to jump through these extra hoops and should "just work". |
6702
|
Tue May 29 14:59:39 2012 |
Jenne | Update | IOO | PMC, MC alignment are shit |
[Yuta, Jenne]
PMC and MC alignment are both shit, although with the WFS on, the MC is pretty good. We're leaving it for now, so that (a) we don't mess up Koji's work, and (b) we can work on the Xarm. Steve is doing Yarm oplev stuff, so we'll do Yarm later. |
6701
|
Tue May 29 14:58:28 2012 |
Jenne | Update | Locking | ETMX trans camera |
...will be helpful for acquiring lock after the vent. We should install a camera at ETMX. |
6700
|
Tue May 29 10:08:21 2012 |
steve | Update | IOO | centered IOO monitoring qpds |
IOO Angle & IOO Position QPDs centered. |
Attachment 1: 40dtrendIOO.png
|
|
Attachment 2: IOOcentered.png
|
|
6699
|
Tue May 29 00:53:57 2012 |
Den | Update | CDS | problems |
I've noticed several CDS problems:
- Communication sign on C1SUS model turns to red once in a while. I press diag reset and it is gone. But after some time comes back.
- On C1LSC machine red "U" lamp shines with a period ~5 sec.
- I was not able to read data from the SR785 using netgpibdata.py. Either connection is not established at all, or data starts to download and then stops in the middle. I've checked the cables, power supplies and everything, still the same thing.
|
6698
|
Tue May 29 00:48:51 2012 |
Den | Update | PEM | sts readout box |
STS readout box seems to be partly broken. I've terminated inputs from the seismometer and measured the output. I could not do this for vertical channel because it outputs 7 V DC + 500 mV AC signal. All the switches work fine, 5 V DC is indeed shown when auto zero, calibration, 1 sec resp, sig select are enables. The box has AC power supply that seems to work ok, all measured DC values are equal to the labels. Something is wrong with amplification.

|
6697
|
Tue May 29 00:39:52 2012 |
Den | Update | PEM | Guralp noise |
I've connected Guralp output to the ADC without readout box. I've got the same noise at low frequencies and even worse noise at high frequencies. However, readout box was still used as DC supply and the signal was read from INPUT test points. I'll do the same experiment without touching readout box at all.

|
6696
|
Tue May 29 00:35:57 2012 |
Den | Update | PEM | guralp readout box |
I measured the frequency response of the Guralp readout box and noise by providing sin signal of amplitude 50 mV at 15 Hz for channels 1-3.

It turns out that the gain is ~250, while my liso model simulated it to be 200. This is because it is hard to approximate AD620 amplifier.
Noise of the box does not seem to be too bad at low frequencies. |
6695
|
Sun May 27 23:15:22 2012 |
Den | Update | PEM | experiments with seismometers |
I wondered if linoleum is a reason of high Guralp noise. I measured Guralp noise in 3 cases: they stand on a very soft piece of paper, linulium and stone.

I've calibrated the noise to units m/s/sqrt(Hz). Using soft paper we get the worst noise, stone - the best, but noises do not differ that much and still much worse then declared noise in the manual.

|
6694
|
Sun May 27 17:19:27 2012 |
rana | Summary | lore | Strawberries |
We have placed some sweet giant strawberries in the fridge; free for eating for anyone working in the lab today or tomorrow:

|
6693
|
Sat May 26 23:57:11 2012 |
Den | Update | PEM | Guralp noise |
I've looked through the Guralp manual to figure out what noise do they declare. They present it in acceleration units in dB relative to 1 m2 / s4 / Hz. I've converted my measurements to this units and got

They declare much better noise. May be linoleum makes an effort. Do we have any isolation boxes? |
6692
|
Sat May 26 20:40:48 2012 |
Den | Update | PEM | experiments with seismic noise |
I measured relative motion of 2 seismometers separated by 4, 18 and 38 feet.

Relative motion for difference distances between seismometers is presented below.

Al frequencies f < fcrit relative motion becomes smaller then motion of each point. At these frequencies, the ratio relative / absolute motion can be approximated as ratio = C fa . The following table summarizes fcrit, C and a for different length between seismometers.
L, ft |
fcrit, Hz
|
C |
a |
4 |
45 |
0.0074 |
1.30 |
18 |
30 |
0.0057 |
1.52 |
38 |
15 |
0.0208 |
1.43 |
Using this approximation we can estimate the desired noise floor of the seismometer to subtract seismic noise from MC_F

Desired seismometer noise should be 100 times less then Guralp's. ADC noise is still less then this level, so this will not be a problem.
Note: for longer cavities condition for seismometer noise becomes more week as fcrit decreases with length.
|