kiwamu | Update | CDS | rebooted DAQ and all the front end machines | I found that all the front end machine showed the red light indicators of DAQ on the XXX_GDS_TP.adl screens.
Also I could not get any data from both test points and DAQ channels.
First I tried fixing by telneting and rebooting fb, but it didn't help.
So I rebooted all the front end machines, and then everything became fine.
|
4025
|
Wed Dec 8 12:26:56 2010 |
josephb | Update | CDS | megatron set up - as a test front end | [josephb, Osamu]
Megatron Setup:
To show Osamu how to setup a a front end as well as provide a test computer for Osamu's use, we used the new megatron (sunfire x4600 with 16 cores and 8 gigabytes of memory) as a front end without an IO chassis.
The steps we followed are in the wiki, here.
The new megatron's IP address is 192.168.113.209. It is running the c1x99 front end code. |
4027
|
Wed Dec 8 14:46:19 2010 |
josephb, kiwamu | Update | CDS | Why the ETMX daq channels were not recorded last night | When adding the ETMX DAQ channels using the daqconfig gui (located in /opt/rtcds/caltech/c1/scripts/) on C1SCX.ini, we forgot to set the acquire flag to 1 from 0.
So the frame builder was receiving the data, but not recording it.
We have since then added ETMX and the C1SCX.ini file to Yuta's useful "activateDAQ.py" script in /opt/rtcds/caltech/c1/chans/daq/, so that it now sets the sensor and SUSPOS like channels to be acquired at 2k when run. You still need to restart the frame builder (telnet fb 8087 and then shutdown) for these changes to take effect.
The script now also properly handles files which already have had channels activated, but not acquired. |
4028
|
Wed Dec 8 14:51:09 2010 |
josephb | Update | CDS | c1pem now recording data | Problem:
c1pem model was reporting all zeros for all the PEM channels.
Solution:
Two fold. On the software end, I added ADCs 0, 1, and 2 to the model. ADC 3 was already present and is the actual ADC taking in PEM information.
There was a problem noted awhile back by Alex and Rolf that there's a problem with the way the DACs and ADCs are number internally in the code. Missing ADCs or DACs prior to the one you're actually using can cause problems.
At some point that problem should be fixed by the CDS crew, but for now, always include all ADCs and DACs up to and including the highest number ADC/DAC you need to use for that model.
On the physical end, I checked the AA filter chassis and found the power was not plugged in. I plugged it in.
Status:
We now have PEM channels being recorded by the FB, which should make Jenne happier. |
4029
|
Wed Dec 8 17:05:39 2010 |
josephb | Update | CDS | Put in dolphin fiber between c1sus and c1lsc | [josephb,Suresh]
We put in the fiber for use with the Dolphin reflected memory between c1sus and c1lsc (rack 1X4 to rack 1Y3). I still need to setup the dolphin hub in the 1X4 rack, but once that is done, we should be able to test the dolphin memory tomorrow. |
4037
|
Thu Dec 9 12:28:52 2010 |
josephb, alex | Update | CDS | The Dolphin is in (Reflected memory that is) | Setting the Configurations files:
On the fb machine in /etc/dis/ there are several configurations files that need to be set for our dolphin network.
First, we modify networkmanager.conf.
We set "-dimensionX 2;" and leave the dimensionY and dimensionZ as 0. If we had 3 machines on a single router, we'd set X to 3, and so forth.
We then modify dishosts.conf.
We add an entry for each machine that looks like:
#Keyword name nodeid adapter link_width
HOSTNAME: c1sus
ADAPTER: c1sus_a0 4 0 4
The nodeids (the first number after the name) increment by 4 each time, so c1lsc is:
HOSTNAME: c1lsc
ADAPTER: c1lsc_a0 8 0 4
The file cluster.conf is automatically updated by the code by parsing the dishosts.conf and networkmanager.conf files.
Getting the code to automatically start:
We uncommented the following lines in the rc.local file in /diskless/root/etc on the fb machine:
# Initialize Dolphin
sleep 2
# Have to set it first to node 4 with dxconfig or dis_nodemgr fails. Unexplai ned.
/opt/DIS/sbin/dxconfig -c 1 -a 0 -slw 4 -n 4
/opt/DIS/sbin/dis_nodemgr -basedir /opt/DIS
For the moment we left the following lines commented out:
# Wait for Dolphin to initialize on all nodes
#/etc/dolphin_wait
We were unsure of the effect of the dolphin_wait script on the front ends without Dolphin cards. It looks like the script it calls waits until there are no dead nodes.
In /etc/conf.d/ on the fb machine we modified the local.start file by uncommenting:
/opt/DIS/sbin/dis_networkmgr&
This starts the Dolphin network manager on the fb machine. The fb machine is not using a Dolphin connection, but controls the front end Dolphin connections via ethernet.
The Dolphin network manager can be interacted with by using the dxadmin program (located in /opt/DIS/sbin/ on the fb machine). This is a GUI program so use ssh -X when logging into the fb before use.
Setting up the front ends models:
Each IOP model (c1x02, c1x04) that runs on a machine using the Dolphin RFM cards needs to have the flag pciRfm=1 set in the configuration box (usually located in the upper left of the model in Simulink). Similarly, the models actually making use of the Dolphin connections should have it set as well. Use the PCIE_SignalName parts from IO_PARTS in the CDS_PARTS.mdl file to send and receive communications via the Dolphin RFM. |
4045
|
Mon Dec 13 11:56:32 2010 |
josephb, alex | Update | CDS | Dolphin is working | Problem:
The dolphin RFM was not sending data between c1lsc and c1sus.
Solution:
Dig into the controller.c code located in /opt/rtcds/caltech/c1/core/advLigoRTS/src/fe/. Find this bit of code on line 2173:
2173 #ifdef DOLPHIN_TEST
2174 #ifdef X1X14_CODE
2175 static const target_node = 8; //DIS_TARGET_NODE;
2176 #else
2177 static const target_node = 12; //DIS_TARGET_NODE;
2178 #endif
2179 status = init_dolphin(target_node);
Replace it with this bit of code:
2173 #ifdef DOLPHIN_TEST
2174 #ifdef C1X02_CODE
2175 static const target_node = 8; //DIS_TARGET_NODE;
2176 #else
2177 static const target_node = 4; //DIS_TARGET_NODE;
2178 #endif
2179 status = init_dolphin(target_node);
Basically this was hard coded for use at the site on their test stands. When starting up, the dolphin adapter would look for a target node to talk to, that could not be itself. So, all the dolphin adapters would normally try to talk to target_node 12, unless it was the X1X14 front end code, which happened to be the one with dolphin node id 12. It would try to talk to node 8.
Unfortunately, in our setup, we only had nodes 4 and 8. Thus, both our codes would try to talk to a nonexistent node 12. This new code has everyone talk to node 4, except the c1x02 process which talks to node 8 (since it is node 4 and can't talk to itself).
I'm told this stuff is going away in the next revision and shouldn't have this hard coded stuff.
Different Dolphin Problem and Fix:
Apparently, the only models which should have pciRfm=1 are the IOP models which have a dolphin connection. Front end models that are not IOP models (like c1lsc and c1rfm) should not have this flag set. Otherwise they include the dolphin drivers and causes them and the IOP to refuse to unload when using rmmod.
So pciRfm=1 only in IOP models using Dolphin, everyone else should not have it or should have pciRfm=-1.
Current CDS status:
MC damp |
dataviewer |
diaggui |
AWG |
c1ioo |
c1sus |
c1iscex |
RFM |
Dolphin RFM |
Sim.Plant |
Frame builder |
TDS |
|
|
|
|
|
|
|
|
|
|
|
|
|
4046
|
Mon Dec 13 17:18:47 2010 |
josephb | Update | CDS | Burt updates | Problem:
Autoburt wouldn't restore settings for front ends on reboot
What was done:
First I moved the burt directory over to the new directory structure.
This involved moving /cvs/cds/caltech/burt/ to /opt/rtcds/caltech/c1/burt.
Then I updated the burt.cron file in the new location, /opt/rtcds/caltech/c1/burt/autoburt/. This pointed to the new autoburt.pl script.
I created an autoburt directory in the /opt/rtcds/caltech/c1/scripts directory and placed the autoburt.pl script there.
I modified the autoburt.pl script so that it pointed to the new snapshot location. I also modified it so it updates a directory called "latest" located in the /opt/rtcds/caltech/c1/burt/autoburt directory. In there is a set of soft links to the latest autoburt backup.
Lastly, I edited the crontab on op340m (using crontab -e) to point to the new burt.cron file in the new location.
This was the easiest solution since the start script is just a simple bash script and I couldn't think of a quick and easy way to have it navigate the snapshots directory reliably.
I then modified the Makefile located in /opt/rtcds/caltech/c1/core/advLigoRTS/ which actually generates the start scripts, to point at the "latest" directory when doing restores. Previously it had been pointing to /tmp/ which didn't really have anything in it.
So in the future, when building code, it should point to the correct snapshots now. Using sed I modified all the existing start scripts to point to the latest directory when grabbing snapshots.
Future:
According to Keith directory documentation (see T1000248) , the burt restores should live in the individual target system directory i.e. /target/c1sus/burt, /target/c1lsc/burt, etc. This is a distinctly different paradigm from what we've been using in the autoburt script, and would require a fairly extensive rewrite of that script to handle this properly. For the moment I'm keeping the old style, everything in one directory by date. It would probably be worth discussing if and how to move over to the new system. |
4053
|
Tue Dec 14 11:24:35 2010 |
josephb | Update | CDS | burt restore | I had updated the individual start scripts, but forgotten to update the rc.local file on the front ends to handle burt restores on reboot.
I went to the fb machine and into /diskless/root/etc/ and modified the rc.local file there.
Basically in the loop over systems, I added the following line:
/opt/epics-3.14.9-linux/base/bin/linux-x86/burtwb -f /opt/rtcds/caltech/c1/burt/autoburt/latest/${i}epics.snap -l /opt/rtcds/caltech/c1/burt/autoburt/logs/${i}epics.log.restore -v
The ${i} gets replaced with the system name in the loop (c1sus, c1mcs, c1rms, etc)
|
4057
|
Wed Dec 15 13:36:44 2010 |
josephb | Update | CDS | ETMY IO chassis update | I gave Alex a sob story over lunch about having to go and try to resurrect dead VME crates. He and Rolf then took pity on me and handed me their last host interface board from their test stand, although I was warned by Rolf that this one (the latest generation board from One Stop) seems to be flakier than previous versions, and may require reboots if it starts in a bad state.
Anyways, with this in hand I'm hoping to get c1iscey damping by tomorrow at the latest. |
4058
|
Wed Dec 15 14:23:32 2010 |
Koji | Update | CDS | ETMY IO chassis update | Great!
I wish this board works fine at least for several days...
Quote: |
I gave Alex a sob story over lunch about having to go and try to resurrect dead VME crates. He and Rolf then took pity on me and handed me their last host interface board from their test stand, although I was warned by Rolf that this one (the latest generation board from One Stop) seems to be flakier than previous versions, and may require reboots if it starts in a bad state.
Anyways, with this in hand I'm hoping to get c1iscey damping by tomorrow at the latest.
|
|
4060
|
Wed Dec 15 17:21:20 2010 |
josephb | Update | CDS | ETMY controls status | Status:
The c1iscey was converted over to be a diskless Gentoo machine like the other front ends, following the instructions found here. Its front end model, c1scy was copied and approriately changed from the c1scx model, along with the filter banks. A new IOP c1x05 was created and assigned to c1iscey.
The c1iscey IO chassis had the small 4 PCI slot board removed and a large 17 PCI slot board put in. It was repopulated with an ADC/DAC/BO and RFM card. The host interface board from Rolf was also put in.
On start up, the IOP process did not see or recognize any of the cards in the IO chassis.
Four reboots later, the IOP code had seen the ADC/DAC/BO/RFM card once. And on that reboot, there was a time out on the ADC which caused the IOP code to exit.
In addition to the not seeing the PCI cards most of the time, several cables still need to be put together for plugging into the the adapter boards and a box need to be made for the DAC adapter electronics.
|
4065
|
Thu Dec 16 15:10:18 2010 |
josephb, kiwamu | Update | CDS | ETMY working at the expense of ETMX | I acquired a second full pair of Host interface board cards (one for the computer and one for the chassis) from Rolf (again, 2nd generation - the bad kind).
However, they exhibited the same symptoms as the first one that I was given.
Rolf gave a few more suggestions on getting it to work. Pull the power plugs. If its got slow flashing green lights, just soft cycle, don't power cycle. Alex suggested turning the IO chassis on before the computer.
None of it seemed to help in getting the computer talking to the IO chassis.
I finally decided to simply take the ETMX IO chassis and place it at the Y end. So for the moment, ETMY is working, while ETMX is temporarily out of commission.
We also made the necessary cables (2x 37 d-sub female to 40 pin female and 40 pin female to 40 pin female) . Kiwamu also did nice work on creating a DAC adapter box, since Jay had given me a spare board, but nothing to put it in. |
4068
|
Fri Dec 17 02:22:06 2010 |
kiwamu | Update | CDS | ETMY damping: not good | I made some efforts in order to damp ETMY, however it still doesn't happily work.
It looks like something wrong is going on around the whitening filters and the AA filter borad.
I will briefly check those analog parts tomorrow morning.
- - -(symptom)
Signs of the UL and the SD readouts are flipped, which I don't know why.
At the testpoints on the analog PD interface board, all the signs are the same. This is good.
But after the signals go through the whitening filters and AA filters, UL and SD become sign-flipped.
I tried compensating the sign-flips by changing the sign by means of the software, but it didn't help the damping.
In fact the suspension got crazy when I activated the damping. So I have no idea if we are looking at exactly right readouts or some sort of different signals.
- - -(fixing DAC connector)
I fixed a connector of the DAC ribbon cable since the solderless connector was loosely locked to its cable.
Before fixing this connector I couldn't apply voltages on some of the coils but now it is working well.
|
4075
|
Mon Dec 20 10:06:36 2010 |
kiwamu | Update | CDS | ETMY damped | Last Saturday I succeeded in damping the ETMY suspension eventually. 
This means now ALL the suspensions are happily damped.
It looked like some combination of gains and control filters had made unstabie conditions.

I actually was playing with the on/off switches of the control filters and the gain values just for fun.
Then finally I found it worked when the chebyshev filters were off. This is the same situation as Yuta told me about two months before.
Other things like the input and the output matrix looked nothing is wrong, except for the sign flips at ULSEN and SDSEN as I mentioned in the last entry (see here).
So we still should take a look at the analog filters in order to make sure why the signs are flipped. |
4097
|
Fri Dec 24 09:01:33 2010 |
josephb | Update | CDS | Borrowed ADC | Osamu has borrowed an ADC card from the LSC IO chassis (which currently has a flaky generation 2 Host interface board). He has used it to get his temporary Dell test stand running daqd successfully as of yesterday.
This is mostly a note to myself so I remember this in the new year, assuming Osamu hasn't replaced the evidence by January 7th. |
4101
|
Sat Jan 1 19:13:40 2011 |
rana | Update | CDS | c1pem now recording data | I found that there was no PEM data nor any other data (no SUS or otherwise. No testpoints, no DAQ).
I went through the procedure that Jenne has detailed in the Wiki but it didn't work.
1) Firstly, the 'telnet fb 8088' step doesn't work. It says "Connected to fb.martian" but then just hangs. To replicate the effect of this step I tried ssh'ing to fb and doing a 'pkill daqd'. That works to restart the daqd process.
2) The wiki instructions had a problem. In the GUI step, it should say 'Save' after the Acquire bit has been set to 1. Even so, this works to get the .ini file right and the DTT can see the correct channel list, but none of the channels are available. There are just 'Unable to obtain measurement data'.
3) I tried running 'startc1pem', but no luck. I also tried rebooting c1sus from the command line. That worked so far as to come back up with all the right processes running, but still no data. The actual /frames directory shows that there are frames, but we just can't see the data. I also tried to get data usind the DTT-NDS2 method, but still no luck. (*** ITMX and ITMY both came back with all their filters off; worth checking if their BURTs are working correctly.)
Using DataViewer, however, I AM able to see the data (although the channel name is RED). In fact, I am able to see the trend data ever since I changed the Acquire bit to 1. Plot attached as evidence. Why does DTT not work anymore??? |
Attachment 1: Untitled.png
|
|
4126
|
Sat Jan 8 21:12:12 2011 |
rana | Update | CDS | Megatron is back | I started reverting Megatron into a standard Ubuntu workstation after Joe/Osamu's attempt to steal it for their real time mumbo jumbo.
First, I installed a hard drive that was sitting around on top of it. That whole area is still a mess; I'm not surprised that we have so many CDS problems in such a chaotic state. There's another drive sitting around there called 'RT Linux' which I didn't use yet.
Second, I removed the ethernet cables and installed a monitor/keyboard/mouse on it.
Then I popped in the Ubuntu 10.04 LTS DVD, wiped the existing CentOS install and started the standard graphical installation of Ubuntu.

Megatron's specs attached: |
Attachment 2: sysinfo.text
|
4129
|
Mon Jan 10 16:39:36 2011 |
josephb, alex, rolf | Update | CDS | New Time server for frame builder and 1PPS | Alex and Rolf came over today with a Tempus LX GPS network timing server. This has an IRIG-B output and a 1PPS output. It can also be setup to act as an NTP server (although we did not set that up).
This was placed at waist height in the 1X7 rack. We took the cable running to the presumably roof mounted antenna from the VME timing board and connected it to this new timing server. We also moved the source of the 1PPS signal going to the master timer sequencer (big blue box in 1X7 with fibers going to all the front ends) to this new time server. This system is currently working, although it took about 5 minutes to actually acquire a timing signal from the GPS satellites. Alex says this system should be more stable, with no time jumps.
I asked Rolf about the new timing system for the front ends, he had no idea when that hardware would be available to the 40m.
Currently, all the front ends and the frame builder agree on the time. Front ends are running so the 1 PPS signal appears to be working as well. |
4130
|
Mon Jan 10 16:47:08 2011 |
josephb, alex, rolf | Update | CDS | Fixed c1lsc dolphin reflected memory | While Alex and Rolf were visiting, I pointed out that the Dolphin card was not sending any data, not even a time stamp, from the c1lsc machine.
After some poking around, we realized the IOP (input/output processor) was coming up before the Dolphin driver had even finished loading.
We uncommented the line
#/etc/dolphin_wait
in the /diskless/root/etc/rc.local file on the frame builder. This waits until the dolphin module is fully loaded, so it can hand off a correct pointer to the memory location that the Dolphin card reads and writes to. Previously, the IOP had been receiving a bad pointer since the Dolphin driver had not finished loading.
So now the c1lsc machine can communicate with c1sus via Dolphin and from there the rest of the network via the traditional Ge Fanuc RFM. |
4132
|
Tue Jan 11 11:19:13 2011 |
josephb | Summary | CDS | Storing FE harddrives down Y arm | Lacking a better place, I've chosen the cabinet down the Y arm which had ethernet cables and various VME cards as a location to store some spare CDS computer equipment, such as harddrives. I've added (or will add in 5 minutes) a label "FE COMPUTER HARD DRIVES" to this cabinet. |
4134
|
Tue Jan 11 13:32:52 2011 |
josephb, kiwamu | Update | CDS | Updated some DAQ channel names | [Joe, Kiwamu]
We modified the activateDAQ.py script which lives in /opt/rtcds/caltech/c1/chans/daq/ and updates the C1SUS.ini, C1MCS.ini, C1RMS.ini, C1SCX.ini and C1SCY.ini files. These files contain the DAQ channels for all the optics.
It has been modified so that channels like C1:SUS-ITMX_ULSEN_OUT_DAQ become C1:SUS-ITMX_SENSOR_UL. Similarly the oplev signals go from C1:SUS-ITMX_OLPIT_OUT to C1:SUS-ITMX_OPLEV_PERROR.
After some debugging, we ran the script successfully and checked the output was correct. We then restarted the frame builder (telnet fb 8088 and then shutdown) and also hit the DAQ reload button for all the front ends.
I tested in dataviewer that I could go back several years as well as going back just 1 hour in the history and see data for C1:SUS-ITMX_SENSOR_LL as well as C1:SUS-ITMX_OPLEV_YERROR. I also tested realtime is also working for these channels.
The contents of the script are below.
inputfiles=["C1SUS.ini","C1RMS.ini","C1MCS.ini","C1SCX.ini","C1SCY.ini"]
prefix="[C1:SUS-"
optics=["BS_","ITMX_","ITMY_","PRM_","SRM_","MC1_","MC1_","MC2_","MC3_","ETMX_"]
#channels=["SUSPOS_IN1","SUSPIT_IN1","SUSYAW_IN1","SUSSIDE_IN1","ULSEN_OUT","URSEN_OUT","LRSEN_OUT","LLSEN_OUT","SDSEN_OUT","OL_SUM_IN1","OLPIT_IN1","OLYAW_IN1"]
channels_dict = {'SUSPOS_IN1':'SUSPOS_IN1_DAQ',
'SUSPIT_IN1':'SUSPIT_IN1_DAQ',
'SUSYAW_IN1':'SUSYAW_IN1_DAQ',
'SUSSIDE_IN1':'SUSSIDE_IN1_DAQ',
'ULSEN_OUT':'SENSOR_UL',
'URSEN_OUT':'SENSOR_UR',
'LRSEN_OUT':'SENSOR_LR',
'LLSEN_OUT':'SENSOR_LL',
'SDSEN_OUT':'SENSOR_SIDE',
'OLPIT_OUT':'OPLEV_PERROR',
'OLYAW_OUT':'OPLEV_YERROR',
'OL_SUM_OUT':'OPLEV_SUM'}
suffix="_DAQ]\n"
## set datarate
datarate=2048
## read the ini files
for inputfile in inputfiles:
print inputfile
outputfile=inputfile
ifile = open(inputfile,'r')
lines = ifile.readlines()
ifile.close()
for k in range(len(lines)):
for op in optics:
for ch in channels_dict:
if (prefix+op+ch+suffix) in lines[k]:
lines[k]=prefix + op + channels_dict[ch] + "]\n"
lines[k+1]=lines[k+1].lstrip("#").rstrip(lines[k+1].split("=")[1])+"1\n"
lines[k+2]=lines[k+2].lstrip("#")
lines[k+3]=lines[k+3].lstrip("#").rstrip(lines[k+3].split("=")[1])+str(datarate)+"\n"
lines[k+4]=lines[k+4].lstrip("#")
ofile = open(outputfile,'w')
for k in range(len(lines)):
ofile.write(lines[k])
#print lines[k]
ofile.close()
|
4136
|
Tue Jan 11 16:04:17 2011 |
josephb | Update | CDS | Script to update web views of models for all installed front ends | I wrote a new script that is in /opt/rtcds/caltech/c1/scripts/AutoUpdate/ called webview_simlink_update.m.
This m-file when run in matlab will go to the /opt/rtcds/caltech/c1/target directory and for each c1 front end, generate the corresponding webview files for that system and place them in the AutoUpdate directory.
Afterwards the files can be moved on Nodus to the /users/public_html/FE/ directory with:
mv /opt/rtcds/caltech/c1/scripts/AutoUpdate/*slwebview* /users/public_html/FE/
This was run today, and the files can be viewed at:
https://nodus.ligo.caltech.edu:30889/FE/
Long term, I'd like to figure out a way of automating this to produce automatically updated screens without having to run it manually. However, simulink seems to stubbornly require an X window to work. |
4144
|
Wed Jan 12 17:50:21 2011 |
josephb | Update | CDS | Worked on c1lsc, MC2 screens | [josephb, osamu, kiwamu]
We worked over by the 1Y2 rack today, trying to debug why we didn't get any signal to the c1lsc ADC.
We turned off the power to the rack several times while examining cards, including the whitening filter board, AA board, and the REFL 33 demod board. I will note, I incorrectly turned off power in the 1Y1 rack briefly.
We noticed a small wire on the whitening filter board on the channel 5 path. Rana suggested this was to part of a fix for the channels 4 and 5 having too much cross talk. A trace was cut and this jumper added to fix that particular problem.
We confirmed would could pass signals through each individual channel on the AA and whitening filter boards. When we put them back in, we did noticed a large offset when the inputs were not terminated. After terminating all inputs, values at the ADC were reasonable, measuring on from 0 to about -20 counts. We applied a 1 Hz, 0.1 Vpp signal and confirmed we saw the digital controls respond back with the correct sine wave.
We examined the REFL 33 demod board and confirmed it would work for demodulating 11 MHZ, although without tuning, the I and Q phases will not be exactly 90 degrees apart.
The REFL 33 I and Q outputs have been connected to the whitening board's 1 and 2 inputs, respectively. Once Kiwamu adds approriate LO and PD signals to the REFL 33 demod board he should be able to see the resulting I and Q signals digitally on the PD1 I and Q channels.
In an unrelated fix, we examined the suspensions screens, specifically the Dewhitening lights. Turns out the lights were still looking at SW2 bit 7 instead of SW2 bit 5. The actual front end models were using the correct bit (21 which corresponds to the 9th filter bank), so this was purely a display issue. Tomorrow I'll take a look at the binary outputs and see why the analog filters aren't actually changing.
|
4146
|
Wed Jan 12 22:33:24 2011 |
kiwamu | Update | CDS | MC2 dewhitening are healthy except for UR | I briefly checked the MC2 analog dewhitening filters.
It turned out that the switching of the dewhitening filters from epics worked correctly except for the UR path.
I couldn't get a healthy transfer function for the UR path probably because the UR monitor at the front panel on either the AI filter or the dewhitening filter maybe broken.
Need a check again.
Quote: #4144 |
Tomorrow I'll take a look at the binary outputs and see why the analog filters aren't actually changing.
|
|
4150
|
Thu Jan 13 14:21:13 2011 |
josephb | Update | CDS | Webview of front end model files automated | After Rana pointed me to Yoichi's MEDM snapshot script, I learned how to use Xvfb, which is what Yoichi used to write screens without a real screen. With this I wrote a new cron script, which I added to Mafalda's cron tab to be run once a day at 6am.
The script is called webview_update.cron and is in /opt/rtcds/caltech/c1/scripts/AutoUpdate/.
#!/bin/bash
DISPLAY=:6
export DISPLAY
#Check if Xvfb server is already running
pid=`ps -eaf|grep vfb | grep $DISPLAY | awk '{print $2}'`
if [ $pid ]; then
echo "Xvfb already running [pid=${pid}]" >/dev/null
else
# Start Xvfb
echo "Starting Xvfb on $DISPLAY"
Xvfb $DISPLAY -screen 0 1600x1200x24 >&/dev/null &
fi
pid=$!
echo $pid > /opt/rtcds/caltech/c1/scripts/AutoUpdate/Xvfb.pid
sleep 3
#Running the matlab process
/cvs/cds/caltech/apps/linux/matlab/bin/matlab -display :6 -logfile /opt/rtcds/caltech/c1/scripts/AutoUpdate/webview.log -r webview_simlink_update
|
4152
|
Thu Jan 13 16:41:07 2011 |
josephb | Update | CDS | Channel names for LSC updated | I renamed most of the filter banks in the c1lsc model. The input filters are now labeled based on the RF photodiode's name, plus I or Q. The last set of filters in the OM subsystem (output matrix) have had the TO removed, and are now sensibly named ETMX, ETMY, etc.
We also removed the redundant filter banks between the LSCMTRX and the LSC_OM_MTRX. There is now only one set, the DARM, CARM, etc ones.
The webview of the LSC model can be found here. |
4160
|
Fri Jan 14 20:39:20 2011 |
rana | Update | CDS | Updated some DAQ channel names | I like this activateDAQ script, but someone (Jenne with Joe's help) still needs to add the PEM channels - we still cannot see any seismic trends. |
4171
|
Thu Jan 20 00:39:22 2011 |
kiwamu | HowTo | CDS | DAQ setup : another trick | Here is another trick for the DAQ setup when you add a DAQ channel associated with a new front end code.
Once you finish setting up the things properly according to this wiki page (this page ), you have to go to
/cvs/cds/rtcds/caltech/c1/target/fb
and then edit the file called master.
This file contains necessary path where fb should look at, for the daqd initialization.
Add your path associated with your new front end code on this file, for example:
/opt/rtcds/caltech/c1/chans/daq/C1LSC.ini
/opt/rtcds/caltech/c1/target/gds/param/tpchn_c1lsc.par
After editing the file, restart the daqd on fb by the usual commands:
telnet fb 8088
shutdown |
4173
|
Thu Jan 20 04:03:02 2011 |
kiwamu | Update | CDS | c1scy error | I found that c1scy was not running due to a daq initialization error.
I couldn't figure out how to fix it, so I am leaving it to Joe.
Here is the error messages in the dmesg on c1iscey
[ 39.429002] c1scy: Invalid num daq chans = 0
[ 39.429002] c1scy: DAQ init failed -- exiting
Before I found this fact, I rebooted c1iscey in order to recover the synchronization with fb.
The synchronization had been lost probably because I shutdowned the daqd on fb.
|
4175
|
Thu Jan 20 10:15:50 2011 |
josephb | Update | CDS | c1scy error | This is caused by an insufficient number of active DAQ channels in the C1SCY.ini file located in /opt/rtcds/caltech/c1/chans/daq/. A quick look (grep -v # C1SCY.ini) indicates there are no active channels. Experience tells me you need at least 2 active channels.
Taking a look at the activateDAQ.py script in the daq directory, it looks like the C1SCY.ini file is included, by the loop over optics is missing ETMY. This caused the file to improperly updated when the activateDAQ.py script was run. I have fixed the C1SCY.ini file (ran a modified version of the activate script on just C1SCY.ini).
I have restarted the c1scy front end using the startc1scy script and is currently working.
Quote: |
Here is the error messages in the dmesg on c1iscey
[ 39.429002] c1scy: Invalid num daq chans = 0
[ 39.429002] c1scy: DAQ init failed -- exiting
|
|
4179
|
Thu Jan 20 18:20:55 2011 |
josephb | Update | CDS | c1iscex computer and c1sus computer swapped | Since the 1U sized computers don't have enough slots to hold the host interface board, RFM card, and a dolphin card, we had to move the 2U computer from the end to middle to replace c1sus.
We're hoping this will reduce the time associated with reads off the RFM card compared to when its in the IO chassis. Previous experience on c1ioo shows this change provides about a factor of 2 improvement, with 8 microseconds per read dropping to 4 microseconds per read, per this elog.
So the dolphin card was moved into the 2U chassis, as well as the RFM card. I had to swap the PMC to PCI adapter on the RFM card since the one originally on it required an external power connection, which the computer doesn't provide. So I swapped with one of the DAC cards in the c1sus IO chassis.
But then I forgot to hit submit on this elog entry.............. |
4183
|
Fri Jan 21 15:26:15 2011 |
josephb | Update | CDS | c1sus broken yesterday and now fixed | [Joe, Koji]
Yesterday's CDS swap of c1sus and c1iscex left the interfometer in a bad state due to several issues.
The first being a need to actually power down the IO chassis completely (I eventually waited for a green LED to stop glowing and then plugged the power back in) when switching computers. I also plugged and plugged the interface cable from the IO chassis and computer while powered down. This let the computer actually see the IO chassis (previously the host interface card was glowing just red, no green lights).
Second, the former c1iscex computer and now new c1sus computer only has 6 CPUs, not 8 like most of the other front ends. Because it was running 6 models (c1sus, c1mcs, c1rms, c1rfm, c1pem, c1x02) and 1 CPU needed to be reserved for the operating system, 2 models were not actually running (recycling mirrors and PEM). This meant the recycling mirrors were left swinging uncontrolled.
To fix this I merged the c1rms model with the c1sus model. The c1sus model now controls BS, ITMX, ITMY, PRM, SRM. I merged the filter files in the /chans/ directory, and reactivated all the DAQ channels. The master file for the fb in the /target/fb directory had all references to c1rms removed, and then the fb was restarted via "telnet fb 8088" and then "shutdown".
My final mistake was starting the work late in the day.
So the lesson for Joe is, don't start changes in the afternoon.
Koji has been helping me test the damping and confirm things are really running. We were having some issues with some of the matrix values. Unfortunately I had to add them by hand since the previous snapshots no longer work with the models. |
4184
|
Fri Jan 21 17:59:27 2011 |
josephb, alex | Update | CDS | Fixed Dolphin transmission | The orientation of the Dolphin cards seems to be opposite on c1lsc and c1sus. The wide part is on top on c1lsc and on the bottom on c1sus. This means, the cable is plugged into the left Dolphin port on c1lsc and into the right Dolphin port on c1sus. Otherwise you get a wierd state where you receive but not transmit. |
4200
|
Tue Jan 25 15:20:38 2011 |
josephb | Update | CDS | Updated c1rfm model plus new naming convention for RFM/Dolphin | After sitting down for 5 minutes and thinking about it, I realized the names I had been using for internal RFM communication were pretty bad. It was because looking at a model didn't let you know where the RFM connection was coming from or going to. So to correct my previous mistakes, I'm instituting the following naming convention for reflected memory, PCIE reflected memory (dolphin) and shared memory names. These don't actually get used anywhere but the models, and thus don't show up as channel names anywhere else. They are replaced by raw hex memory locations in the actual code through the use of the IPC file (/opt/rtcds/caltech/c1/chans/ipc/C1.ipc). However it will make understanding the models easier for anyone looking at them or modifying them.
The new naming convention for RFM and Dolphin channels is as follows.
SITE:Sending Model-Receiving Model_DESCRIPTION_HERE
The description should be unique to that data being transferred and reused if its the same data. Thus if its transfered to another model, its easy to identify it as the same information.
The model should be the .mdl file name, not the subsystem its a part of. So SCX is used instead of SUS. This is to make it easier to track where data is going.
In the unlikely case of multiple models receiving, it should be of the form SITE:Sending Model-Receiving Model 1-Receiving Model 2_DESCRIPTION_HERE. Seperate models by dashes and description by underscores.
Example:
C1:LSC-RFM_ETMX_LSC
This channel goes from the LSC model (on c1lsc) to the RFM model (on c1sus). It transfers ETMX LSC position feedback. The second LSC may seem redundant until we look at the next channel in the chain.
C1:RFM-SCX_ETMX_LSC
This channel goes from the RFM model to the SCX model (on c1iscex). It contains the same information as the first channel, i.e. ETMX LSC position feedback.
I have updated all the models that had RFM and SHMEM connections, as well as adding all the LSC communciation connections to c1rfm. This includes c1sus, c1rfm, c1mcs, c1ioo, c1gcv, c1lsc, c1scx, c1scy. I have not yet built all the models since I didn't finish the updates until this afternoon. I will build and test the code tomorrow morning.
|
4203
|
Tue Jan 25 22:49:13 2011 |
Koji | Update | CDS | Front End multiple crash | STATUS:
- Rebooted c1lsc and c1sus. Restarted fb many times.
- c1sus seems working.
- All of the suspensions are damped / Xarm is locked by the green
- Thermal control for the green is working
- c1lsc is frozen
- FB status: c1lsc 0x4000, c1scx/c1scy 0x2bad
- dataviewer not working
1. DataViewer did not work for the LSC channels (liek TRX)
2. Rebooted LSC. There was no instruction for the reboot on Wiki. But somehow the rebooting automatically launched the processes.
3. However, rebooting LSC stopped C1SUS processes working
4. Rebooted C1SUS. Despite the rebooting description on wiki, none of the FE processes coming up.
5. Probably, I was not enough patient to wait for the completion of dorphine_wait? Rebooted C1SUS again.
6. Yes. That was true. This time I wait for everything going up automatically. Now all of c1pemfe,c1rfmfe,c1mcsfe,c1susfe,c1x02fe are running.
FB status for c1sus processes all green.
7. burtrestored c1pemfe,c1rfmfe,c1mcsfe,c1susfe,c1x02fe with the snapshot on Jan 25 12:07, 2010.
8. All of the OSEM filters are off, and the servo switches are incorrectly on. Pushing many buttons to restore the suspensions.
9. I asked Suresh to restore half of the suspensions.
10. The suspensions were restored and damped. However, c1lsc is still freezed.
11. Rebooting c1lsc freezed the frontends on c1sus. We redid the process No. 5 to No.10
12. c1x04 seems working. c1lsc, however, is still frozen. We decided to leave C1LSC in this state.
|
4206
|
Wed Jan 26 10:58:48 2011 |
josephb | Update | CDS | Front End multiple crash | Looking at dmesg on c1lsc, it looks like the model is starting, but then eventually times out due to a long ADC wait.
[ 114.778001] c1lsc: cycle 45 time 23368; adcWait 14; write1 0; write2 0; longest write2 0
[ 114.779001] c1lsc: ADC TIMEOUT 0 1717 53 181
I'm not sure what caused the time out, although there about 20 messages indicating a failed time stamp read from c1sus (its sending TRX information to c1lsc via the dolphin connection) before the time out.
Not seeing any other obvious error messages, I killed the dead c1lsc model by typing:
sudo rmmod c1lscfe
I then tried starting just the front end model again by going to the /opt/rtcds/caltech/c1/target/c1lsc/bin/ directory and typing:
sudo insmod c1lscfe.ko
This started up just the FE again (I didn't use the restart script because the EPICs processes were running fine since we had non-white channels). At the moment, c1lsc is now running and I see green lights and 0x0 for FB0 status on the C1LSC_GDS_TP screen.
At this point I'm not sure what caused the timeout. I'll be adding some more trouble shooting steps to the wiki though. Also, c1scx, c1scy are probably in need of restart to get them properly sync'd to the framebuilder.
I did a quick test on dataviewer and can see LSC channels such as C1:LSC-TRX_IN1, as well other channels on C1SUS such as BS sensors channels.
Quote: |
STATUS:
- Rebooted c1lsc and c1sus. Restarted fb many times.
- c1sus seems working.
- All of the suspensions are damped / Xarm is locked by the green
- Thermal control for the green is working
- c1lsc is frozen
- FB status: c1lsc 0x4000, c1scx/c1scy 0x2bad
- dataviewer not working
|
|
4207
|
Wed Jan 26 12:03:45 2011 |
Koji | Update | CDS | Front End multiple crash | This is definitely a nice magic to know as the rebooting causes too much hustles.
Also, you and I should spend an hour in the afternoon to add the suspension swtches to the burt requests.
Quote: |
I killed the dead c1lsc model by typing:
sudo rmmod c1lscfe
I then tried starting just the front end model again by going to the /opt/rtcds/caltech/c1/target/c1lsc/bin/ directory and typing:
sudo insmod c1lscfe.ko
This started up just the FE again
|
|
4208
|
Wed Jan 26 12:04:31 2011 |
josephb | Update | CDS | Explanation of why c1sus and c1lsc models crash when the other one goes down | So apparently with the current Dolphin drivers, when one of the nodes goes down (say c1lsc), it causes all the other nodes to freeze for up to 20 seconds.
This 20 seconds can force a model to go over the 60 microseconds limit and is sufficiently long enough to force the FE to time out. Alex and Rolf have been working with the vendors to get this problem fixed, as having all your front ends go down because you rebooted a single computer is bad.
[40184.120912] c1rfm: sync error my=0x3a6b2d5d00000000 remote=0x0
[40184.120914] c1rfm: sync error my=0x3a6b2d5d00000000 remote=0x0
[44472.627831] c1pem: ADC TIMEOUT 0 7718 38 7782
[44472.627835] c1mcs: ADC TIMEOUT 0 7718 38 7782
[44472.627849] c1sus: ADC TIMEOUT 0 7718 38 7782
[44472.644677] c1rfm: cycle 1945 time 17872; adcWait 15; write1 0; write2 0; longest write2 0
[44472.644682] c1x02: cycle 7782 time 17849; adcWait 12; write1 0; write2 0; longest write2 0
[44472.646898] c1rfm: ADC TIMEOUT 0 8133 5 7941
The solution for the moment is to start the computers at exactly the same time, so the dolphin is up before the front ends, or start the models by hand after the computer is up and dolphin running, but after they have timed out. This is done by:
sudo rmmod c1SYSfe
sudo insmod /opt/rtcds/caltech/c1/target/c1SYS/bin/c1SYSfe.ko
Alex and Rolf have been working with the vendors to get this fixed, and we may simply need to update our Dolphin drivers. I'm trying to get in contact with them and see if this is the case. |
4212
|
Thu Jan 27 15:16:43 2011 |
josephb | Update | CDS | Updated generate_master_screens.py | I modified the generate_master_screens.py script in /opt/rtcds/caltech/c1/medm/master/ to handle changing the MCL (and MC_L) listings to ALS for the two ETM suspension screens and associated sub-screens.
The relevant added code is:
custom_optic_channels = ['ETMX',
{'MCL':'ALS','MC_L':'ALS'},
'ETMY',
{'MCL':'ALS','MC_L':'ALS'}]
for index in range(len(custom_optic_channels)/2):
if optic == custom_optic_channels[index*2]:
for swap in custom_optic_channels[index*2+1]:
sed_command = start_sed_string + swap + "/" + custom_optic_channels[index*2+1][swap] + middle_sed_string + optic + file
os.system(sed_command)
When run, it generates the correctly named C1:SUS-ETMX_ALS channels, and replaces MCL and MC_L with ALS in the matrix screens.
|
4220
|
Fri Jan 28 12:15:58 2011 |
josephb | Update | CDS | Updating conlog channel list/ working on "HealthCheck" script | I've updated the scan_adls script (currently located in /cvs/cds/caltech/conlog/bin) to look at new location of our medm screens. I made a backup of the old conlog channel list as /cvs/cds/caltech/conlog/data/conlog_channels.old-2011-01-28.
I then ran the update_chanlist script in the same directory, which calls the scan_adl script. After about 5 minutes it finished updating the channel list. I restarted the conlogger just to be sure, and checked that our new model channels showed up in the conlog (which they do).
I have added a cron job to the op340m cron tab to once a day run the update_conlog script at 7am.
Next, I'm working on a HealthCheck script which looks at the conlog channel list and checks to see if channels are actually changing over short time scales, and then spit back a report on possibly non-functioning channels to the user. |
4241
|
Wed Feb 2 15:07:20 2011 |
josephb | Update | CDS | activateDAQ.py now includes PEM channels | [Joe, Jenne]
We modified the activateDAQ.py script to handle the C1PEM.ini file (defining the PEM channels being recorded by the frame builder) in addition to all the optics channels. Jenne will be modifying it further so as to rename more channels. |
4246
|
Thu Feb 3 16:45:28 2011 |
josephb | Update | CDS | General CDS updates | Updated the FILTER.adl file to have the yellow button moved up, and replaced the symbol in the upper right with a white A with black background. I made a backup of the filter file called FILTER_BAK.adl. These are located in /opt/rtcds/caltech/c1/core/advLigoRTS/src/epics/util.
I also modified the Makefile in /opt/rtcds/caltech/c1/core/advLigoRTS/ to make the startc1SYS scripts it makes take in an argument. If you type in:
sudo startc1SYS 1
it automatically writes 1 to the BURT RESTORE channel so you don't have to open the GDS_TP screen and by hand put a 1 in the box before the model times out.
The scripts also points to the correct burtwb and burtrb files so it should stop complaining about not finding them when running the scripts, and actually puts a time stamped burt snapshot in the /tmp directory when the kill or start scripts are run. The Makefile was also backed up to Makefile_bak.
|
4249
|
Fri Feb 4 13:31:16 2011 |
josephb | Update | CDS | FE start scripts moved to scripts/FE/ from scripts/ | All start and kill scripts for the front end models have been moved into the FE directory under scripts: /opt/rtcds/caltech/c1/scripts/FE/. I modified the Makefile in /opt/rtcds/caltech/c1/core/advLigoRTS/ to update and place new scripts in that directory.
This was done by using
sed -i 's[scripts/start$${system}[scripts/FE/start$${system}[g' Makefile
sed -i 's[scripts/kill$${system}[scripts/FE/kill$${system}[g' Makefile
|
4262
|
Tue Feb 8 16:04:58 2011 |
josephb | Update | CDS | Hard coded decimation filters need to be fixed | [Joe, Rana]
Filter definitions for the decimation filters to epics readback channels (like _OUT16) can be found in the fm10Gen.c code (in /opt/rtcds/caltech/c1/core/advLigoRTS/src/include/drv).
At the moment, the code is broken for systems running at 32k, 64k as they look to be defaulting to the 16k filter. I'd like to also figure out the notation and plot the actual filter used for the 16k.
Rana has suggested a 2nd order, 2db ripple low pass Cheby1 filter at 1 Hz.
51 #if defined(SERVO16K) || defined(SERVOMIXED) || defined(SERVO32K) || defined(SERVO64K) || defined(SERVO128K) || defined(SERVO256K)
52 static double sixteenKAvgCoeff[9] = {1.9084759e-12,
53 -1.99708675982420, 0.99709029700517, 2.00000005830747, 1.00000000739582,
54 -1.99878510620232, 0.99879373895648, 1.99999994169253, 0.99999999260419};
55 #endif
56
57 #if defined(SERVO2K) || defined(SERVOMIXED) || defined(SERVO4K)
58 static double twoKAvgCoeff[9] = {7.705446e-9,
59 -1.97673337437048, 0.97695747524900, 2.00000006227141, 1.00000000659235,
60 -1.98984125831661, 0.99039139954634, 1.99999993772859, 0.99999999340765};
61 #endif
62
63 #ifdef SERVO16K
64 #define avgCoeff sixteenKAvgCoeff
65 #elif defined(SERVO32K) || defined(SERVO64K) || defined(SERVO128K) || defined(SERVO256K)
66 #define avgCoeff sixteenKAvgCoeff
67 #elif defined(SERVO2K)
68 #define avgCoeff twoKAvgCoeff
69 #elif defined(SERVO4K)
70 #define avgCoeff twoKAvgCoeff
71 #elif defined(SERVOMIXED)
72 #define filterModule(a,b,c,d) filterModuleRate(a,b,c,d,16384)
73 #elif defined(SERVO5HZ)
74 #else
75 #error need to define 2k or 16k or mixed
76 #endif |
4265
|
Wed Feb 9 15:26:22 2011 |
josephb | Update | CDS | Updated c1scx with lockin, c1gcv for green transmission pd | Updated the c1scx model to have two Lockin demodulators (C1:SUS-ETMX_LOCKIN1 and C1:SUS-ETMX_LOCKIN2). There is a matrix C1:SUS-ETMX_INMUX which directs signals to the inputs of LOCKIN1 and LOCKIN2. Currently only the GREEN_TRX signal is the only signal going in to this matrix, the other 3 are grounds. The actual clocks themselves had to be at the top level (they don't work inside blocks) and thus named C1:SCX-ETMX_LOCKIN1_OSC and C1:SCX-ETMX_LOCKIN2_OSC.
There is a signal (IPC name is C1:GCV-SCX_GREEN_TRX) going from the c1gcv model to the c1scx model, which will contain the output from Jenne's green transmission PD which will eventually be placed. I've placed a filter bank on it in the c1gcv model as a monitor point, and it corresponds to C1:GCV-GREEN_TRX.
The suspension control screens were modified to have a screen for the Matrix feeding signals into the two lockin demodulators. The green medm screen was also modified to have readbacks for the GREEN_TRX and GREEN_TRY channels.
So on the board, the top channel (labeled 1, corresponds to code ADC_0_0) is MCL.
Channel 2 (ADC_0_1) is assigned to frequency divided green signal.
Channel 3 (ADC_0_2) is assigned to the beat PD's DC output.
Channel 4 (ADC_0_3) is assigned to the green power transmission for the x-arm.
Channel 5 (ADC_0_4) is assigned to the green power transmission for the y-arm. |
4270
|
Thu Feb 10 14:07:18 2011 |
josephb | Update | CDS | Updating dolphin drivers to eliminate timeouts when one dolphin card is shutdown | [Joe,Alex]
Alex came over and we installed the new Dolphin drivers so that the front ends using the Dolphin PCIe RFM network don't pause for a long time when one of the other nodes in the network go down. Generally this pause would cause the code to time out and quit. Now you can take c1lsc or c1sus down without having the other have problems.
We did note on reboot however, that the Dolphin_wait script sometimes (not always) seems to hang. Since this is run at boot up, to ensure the dolphin card has had enough to allocate memory space for data to be written/read from by the IOP process, it means nothing else in the startup script gets run if it does happen. In this case, running "pkill dolphin_wait" may be necessary.
Note that you may still have problems if you hit the power button to force a shutdown (i.e. holding it for 4 seconds for immediate power off), but as long as you do a "reboot" or "shutdown -r now" type command, it should come down gracefully.
What was done:
Alex grabbed the code from his server, and put it /home/controls/DIS/ on fb.
He ran the following commands in that directory to build the code.
./configure '--with-adapter=DX' '--prefix=/opt/DIS'
make
sudo make install
He proceeded to modify the /diskless/root/etc/rc.local to have the line:
insmod /lib/modules/2.6.34.1/kernel/drivers/dis/dis_kosf.ko
In that same file he commented out
cd /root
and
exec /bin/bash/
He then modified the run levels in /diskless/root/etc/inittab. Level 0, level 3, and level 6 were changed:
l0:0:wait/etc/rc.halt
l3:3:wait:etc/rc.level3
l6:6:wait:/etc/rc.reboot
Then he created the scripts he was refering to:
rc.level3 is just:
exec /bin/bash
rc.halt is:
/opt/DIS/sbin/dxtool prepare-shutdown 0
sleep 3
halt -p
rc.reboot is:
reboot
Basically rc.halt calls a special code which prepares the Dolphin RFM card to shutdown nicely. This is why just hitting the power button for 4 seconds will cause problems for the rest of the dolphin network.
We then checked out of svn the latest dolphin.c in /opt/rtcds/caltech/c1/core/advLigoRTS/src/fe
The Dolphin RFM cards have a new numbering scheme. 4 is reserved for special broadcasts to everyone, so the Dolphin node IDs now start at 8. So we needed to change the c1lsc and c1sus Dolphin node IDs.
To change them we went to /etc/dis/dishosts.conf on the fb machine, and changed the following lines:
HOSTNAME: c1sus
ADAPTER: c1sus_a0 4 0 4
HOSTNAME: c1lsc
ADAPTER: c1lsc_a0 8 0 4
to
HOSTNAME: c1sus
ADAPTER: c1sus_a0 8 0 4
HOSTNAME: c1lsc
ADAPTER: c1lsc_a0 12 0 4
The FE models for the c1lsc and c1sus machines were recompiled and then the computers were rebooted. After having them come back up, we tested that there was no time out by shutting down c1lsc and watching c1sus. We then reveresed and shutdown c1sus while watching c1lsc. No problems occured. Currently they are up and communicating fine.
|
4282
|
Mon Feb 14 01:19:18 2011 |
rana | Update | CDS | Today's CDS problems | This is just a listing of CDS problems I still notice today:
-
MC2-MCL button was left ON due to BURT failure. This, of course, screws up our Green locking investigations because of the unintended feedback. Please fix the BURT/button issue.
- The GCV - FB0 status is RED. I guess this means there's something wrong? Its really a bad idea to have a bunch of whited out or falsely red indicators. No one will ever use these or trust these in the future.
- MC1/2/3 Lockins are all white. Also, the MODE switches for the dewhitening are all white.
- Is the MC SIDE coil dewhitening filter synced with anything? It doesn't seem to switch anything. Maybe the dewhite indicators at the top right of the SUS screens can be made to show the state of the binary output instead of just the digital filter
- MC WFS is all still broken. We need a volunteer to take this on - align beams, replace diodes, fix code/screens.
|
4283
|
Mon Feb 14 01:40:14 2011 |
Koji | Omnistructure | CDS | Name of the green related channels | I propose to use C1:ALS-xxx_xxx for the names of the green related channels, instead of GCV, GCX, GCY, GFD...
Like C1:SUS or C1:LSC, we name the channels by the subsystems first, then probably we can specify the place.
We can keep the names of the processes as they are now. |
4285
|
Mon Feb 14 07:58:43 2011 |
Suresh | Update | CDS | Today's CDS problems |
I am concentrating on the RF system just now and will be attending to the RF PDs one by one. Also plan to work on some of the simpler CDS problems when I overlap with Joe. Will be available for helping out with the beam alignment.
|
|