ID |
Date |
Author |
Type |
Category |
Subject |
3187
|
Fri Jul 9 12:07:26 2010 |
Razib | Update | Phase Camera | Weekly update |
Here are some more details about the current phasecam setup. We are using a He-Ne laser setup

A crude snap shot of the setup....
_annotated.jpg?lb=40m&thumb=1)
We sent light through SM2 (Steering Mirror 2) to BS1(Beam-Splitter 1) where the laser light is split into two parts, one going to the AOM and the other to the EOM. The EOM adds 40 MHz sidebands to the incoming carrier light after SM3, and the AOM shifts the frequency of the incident light on it to 40.000 005 MHz. The purpose for doing this juggling is to intentionally create a beat signal off the reference beam from the AOM with the sidebands added at the EOM. Note that, we are driving the AOM at 7dBm and the EOM at 13 dBm with 0 (nil) modulation. The two lights are combined at the BS2 and sent off through SM5 to the camera. The CMOS of the camera contains silicon based Micro MT9V022 chip which has a quantum efficiency of 50% at 633 nm. Thus we expected a fairly good response to this He-Ne setup from the camera.
Using a trigger circuit, we triggered the camera at 20 Hz by sending a 20Hz sinusoidal signal to it. The trigger circuit converts this to a positive square waves. Then I roughly figured out the optimum exposure time for the camera before the DC levels saturates it by writing a code for taking a series of 25 images at different exposure time. I found that 500µs seems to be a reasonable exposure time. So, using this data, I took 20 consecutive images and sent them through a short Fourier Transform segment using Matlab to see the beat signal. Note that the DC component from these processing of the images have some fringe pattern which is due to the ND 2.5 filter that we were using to reduce the light power incident on the camera. The FT method also gave us the presence of the beat signal at the corresponding bin of the FT (for example: for 5Hz beat signal, I got the DC at bin 1 of the FT and 5Hz component at bin 6 as expected). Then I changed the AOM driving frequency to 40.000 001 MHz in order to see a 1 Hz beat signal. The results for both is in my previous post.
Quote: |
I have completed the following tasks:
1. Find a simplified calibration of the exposure time for the current He-Ne setup. Basically, I triggered the camera to take 20 snapshots with a 20 Hz driving signal at different exposure time beginning from 100 us (microsecond) upto 4000 us with an increment of 200 us.
Result: The current power allows the camera to have an exposure time of ~500 us before the DC level begans to saturate.
2. Aidan and I did some alignment and connected the AOM and corrected the driving frequency of its PZT to 40 Mhz(which apparently was disconnected which in turn gets the credit of NO beat signal for me until Tuesday 07/06/2010 5:30 PST) .
Result: I got the beat signal of 1 Hz and 5 Hz. Image follows (the colormap shows the power in arbitrary units).
3. Finished writing my Progress Report 1 .
 
|
|
3186
|
Fri Jul 9 11:41:58 2010 |
Gopal | Summary | Optic Stacks | Top Optic Layer Complete; Mechanical Tests Giving Problems |
For the last week, I have been attempting to determine the mirror stack transfer function which relates mechanical mirror response to a given ground-motion drive. The idea is to model the stacks in COMSOL and ultimately apply mechanical tests for manual calculation.
Procuring the correct drawings to base my 3D models off of was no simple task. There are two binders full of a random assortment of drawings, and some of them are associated with the smaller chambers, while others are appropriate for the main chamber, which is what we're interested in right now. For future workers, I suggest checking that your drawings are appropriate for the task at hand with other people before wasting time beginning the painstaking process of CAD design in COMSOL.
The drawings that I ultimately decided to use are attached below. They detail four layers of stacks, each which arrange 15, 12, 8, and 5 (going from bottom to top) Viton damping springs in an orderly fashion. The numbers have been chosen to keep the load per spring as constant as possible, in order for all springs to oscillate with as close a resonant frequency to each other as possible.



After making some minor simplifications, I have finished modeling the top stack:

After triangular meshing, before my many failed attempts at mechanical testing: 

Both the Viton and steel portions have been given their material properties, and so I should be (theoretically ) ready to perform some eigenfrequency calculations on this simplified system. If my predictions are correct, these eigenfrequencies shouldn’t be too far of the eigenfrequencies of the 4-layer stacked system, because of the layout of the springs. I’ve tried doing mechanical tests on the top stack alone, but there hasn’t been much progress yet on this end, mostly because of some boundary value exceptions that COMSOL keeps throwing at me.
In the next couple weeks or so, I plan to extend this model to combine all four layers into one completed stack, along with a simple steel base and mirror platform. I also plan to figure out how to make eigenfrequency and transfer function measurements.
Lastly, to anyone who is experienced with COMSOL, I am facing two major roadblocks and could really use your help:
1) How to import one model into another, merge models together, or copy and paste the same model over and over.
2) Understanding and debugging run-time errors during mechanical testing.
If you have any idea how to attack either of these issues, please talk to me! Thanks!
|
3185
|
Fri Jul 9 11:09:14 2010 |
josephb | Update | Computers | Fb40m and a few other machines turned off briefly just before 11am |
I turned off fb40m2 and fb40m temporarily while we added an extra power strip to the (new) 1X6 rack at the bottom in the back. This is to allow for the addition of the 4600 computer given to us by Rolf (which needs a good name) into the rack above the fb machine. The fb40m2 was unfortunately plugged into the main power connectors, so we unplugged two of its cables, and put them into the new strip. While trying to undo some of the rats nest of cables in the back I also powered down and unpluged briefly the c0dcu1, the pem crate, and the myrinet bypass box.
I am in the process of bringing those machines back up and restoring the network.
Also this morning, Megatron was moved from the end station into the (new) 1X3 rack, along with its router. This is to allow for the installation of the new end computer and IO chassis.
|
3184
|
Thu Jul 8 21:44:43 2010 |
nancy | Update | IOO | WFS calculations |
I just found the singular values and the condition number of the 4*4 matrix relating the WFS error signals and the MC1 and MC2 movements.
the condition number is ~12.5. I think its small enough to continue with the scheme. (if the measurements and all are reliable).
|
3183
|
Thu Jul 8 20:32:22 2010 |
nancy | Update | IOO | MC alignment values. |
I and Koji were trying to lock the mode cleaner for measuring the beam power at MC2 end. That is when we obtained the trans and refl values.
The beam characteristics at the MC2 were measured so that we could now use a dummy beam of similar power to test and characterize the QPD we are about to install at the MC2 end. This QPD wil provide two more signals in pitch and yaw, and hence complete 6 signals for 6 rotatioanl dof of the cavity. (4 are coming from WFS).
Once the QPD is characterised, it can be used to see the spot position at MC2. This is related to the mirror angles.
The width measurements were done using a beam scan. the beam scan was properly adjusted so that the maxima of the intensity of the sopt was at its center.
We also fitted gaussian curve to the beam profile, and it was a substantially good fit.
The whole idea is that I am trying to look how the Wavefront sensors respond to the perturbations in the mirror angles. Once this is known, we should be able to control the mirror-movements.
the starting point would be to do just the DC measurements (which I did today). For proper analysis, AC measurements are obviously required.(will be done later).
The matrices so calculated can be inverted, and if found enough singular, the method can be used to control.
The first shot is to see teh dependency of teh error signals only on MC1 and MC3, and see if that is kind of enough to control these two mirrors.
If this works, the QPD signals could be used to control MC2 movements.
Quote: |
Hmm. I expect that you will put more details of the work tomorrow.
i.e. motivation, method, result (the previous entry is only this),
and some discussiona with how to do next.
Quote: |
Nancy and Koji:
This is what I and Koji measured after aligning the MC in the afternoon.
MC_Trans 4.595 (avg)
MC_Refl 0.203 (avg)
MC2_trans :
power = 1.34mW
13.5% width : x=6747.8 +- 20.7 um , y = 6699.4+- 20.7 um
|
|
|
3182
|
Thu Jul 8 19:43:16 2010 |
nancy | Update | IOO | WFS calculations |
The WFS error signals were recorded in the order
WFS1_PIT
WFS1_YAW
WFS2_PIT
WFS2_YAW
these measurements are made in the linear region, that is the MC is nearly perfectly aligned.
This is the average and std. dev.of 5 measurements taken of the same signals over 10 secs each. The std. dev are under 10%. And hence, I will be using 10 secs for measurements for the WFS signals after perturbations to the mirrors.
avg =
829.4408
-517.1884
297.4168
-944.7892
std_dev =
9.0506
22.9317
15.4580
8.9827
I perturbed the Pitch and Yaw of the Three mirrors (in order MC1,2,3), using ezcastep and calculated the coefficients that relate these perturbations to the WFS error signals.
The perturbation made is of -0.01 in each dof , and after measuring the WFS error for it, the system is reverted back to the previous point before making the other perturbation.
I was able to calculate the coefficients since I have assumed a linear relationship..
Following are the coefficients calculated using 10 secs measurements
coef_mat =
1.0e+05 *
MC1_P MC1_Y MC2_P MC2_Y MC3_P MC3_Y constant
WFS1_PIT -0.1262 0.3677 -0.4539 -0.6297 -0.1889 -0.1356 0.013664
WFS1_YAW -0.0112 -0.7415 -0.1844 2.4509 -0.0023 -0.3531 -0.016199
WFS2_PIT 0.1251 0.4824 -0.2028 -0.6188 0.0099 -0.1490 0.006890
WFS2_YAW 0.0120 -0.7957 -0.1793 0.9962 -0.0493 0.2672 -0.013695
Also, I measured the same thing for 100s, and to my surprize, even the signs of coeficients are different.
coef_mat =
1.0e+05 *
MC1_P MC1_Y MC2_P MC2_Y MC3_P MC3_Y constant
WFS1_PIT -0.1981 0.3065 -0.6084 -0.9349 -0.4002 -0.3538 0.009796
WFS1_YAW 0.0607 -0.6977 0.0592 2.8753 0.3507 0.0373 -0.008194
WFS2_PIT 0.0690 0.4769 -0.2859 -0.7821 -0.1115 -0.2953 0.004150
WFS2_YAW 0.0580 -0.8153 -0.0937 1.1424 0.0650 0.4203 -0.010629
The reason I can understand is that the measurements were not made at the same time, and hence conditions might have changed.
A thing to note in all these coefficients is that they relate the error signals to the 'perturbation' around a certain point (given below). That point is assumed to lie in the linear region.
MC1_PIT 2.6129
MC1_YAW -5.1781
MC2_PIT 3.6383
MC2_YAW -1.2872
MC3_PIT -1.9393
MC3_YAW -7.518
|
3181
|
Thu Jul 8 17:29:20 2010 |
Katharine, Sharmila | Update | elog | |
Last night, we successfully connected and powered our circuit, which allowed us to test whether our OSEMs were working. Previously, we had been unable to accomplish this because (1) we weren't driving it sufficiently high voltage, and (2) we didn't check that the colored leads on our circuit actually corresponded to the colored ports on the power supply (they were all switched, which we are in the process of rectifying), so our circuit was improperly connected to the supply . Unfortunately, we didn't learn this until after nearly cooking our circuit, but luckily there appears to have been no permanent damage .
Our circuit specs suggested powering it with a voltage difference of 48V, so we needed to run our circuit at a difference of at least 36-40 V. Since our power supply only supplied a difference of up to 30V in each terminal, we combined them in order to produce a voltage of up to double that. We decided to power our circuit with a voltage difference of 40V (+/- 20V referenced to true ground). The current at the terminals were 0.06 and 0.13 A.
To test our circuit, we used a multimeter to check the supplied voltage at different test points, to confirm that an appropriate input bias was given to various circuit elements. We identified the direction of LED bias on our OSEM, and connected it to our circuit. We were extremely gratified when we looked through the IR viewer and saw that, in fact, the LED in the OSEM was glowing happily .

We hooked up two oscilloscopes and measured the current through the coil, and also through the LED and photodiode in the OSEM. We observed a change in the photodiode signal when we blocked the LED light, which was expected. The signal at the PD and the LED were both sinusoidal waves around ~3 kHz.

We then went back to our levitation setup, and crudely tried to levitate a magnet with attached flag by using our hands and adjusting the gain (though we also could have been watching the PD current). The first flag we tried was a soldering tip; we couldn't levitate this but achieved an interesting sort of baby-step "levitation" (levitation .15) which allowed us to balance the conical flag on its tip on top of the OSEM (stable to small disturbances). After learning that conical flags are a poor idea, we switched our flag to a smaller-radius cylindrical magnet. We were much closer to levitating this magnet, but were unable to conclusively levitate it .

Current plan:
Adjust the preset resistors to stabilize feedback
Check LED drive circuit.
Finish calculating the transfer function, and hook up the circuit to the spectrum analyzer to measure it as well.
Observe the signal from the photocurrent as disturbances block the LED light.
Play with the gain of the feedback to see how it affects levitation.
|
Attachment 1: P7070254.JPG
|
|
3180
|
Thu Jul 8 16:24:30 2010 |
Gopal | Update | Optic Stacks | Completion of single stack layer |
Single layer of stack successfully modeled in COMSOL. I'm working on trying to add Viton springs now and extend it to a full stack. Having some difficulty with finding consistent parameters to work with. |
3179
|
Thu Jul 8 15:43:58 2010 |
rana | Update | Computers | Some channels not being recorded!!! |
Quote: |
This has been fixed, thanks to some help from Alex. It doesn't correspond to new computers being put in, but rather corresponds to a dcu_id change I had made in the new LSC model.
|
Just as I expected, since these hunuman didn't actually check MC_L after doing this stuff, MC_L was only recording ZERO. Joe and I reset and restarted c1susmve2 and then
verified (for real this time) that the channel was visible in both the Dataviewer real time display as well as in the trend.

The lesson here is that you NEVER trust that the problem has been fixed until you check for yourself. Also, we must always
specify a very precise test that must be used when we ask for help debugging some complicated software problem.
|
3178
|
Thu Jul 8 15:19:27 2010 |
josephb, koji | Configuration | Computers | Added Zonet camera to IP table on linux1 |
We gave the Zonet camera the IP 192.168.113.26 and the name Zonet1.
We did this by modifying the /var/named/chroot/var/named/113.168.192.in-addr.arpa.zone and martian.zone files on linux1 as root. |
3177
|
Thu Jul 8 14:32:42 2010 |
josephb | Update | CDS | Daily Downs Update |
After talking with Rolf, and clarifying exactly which machine I wanted, he gave me an 4600 Sun machine (similar to our current megatron). I'm currently trying to find a good final place for it, but its at least here at the 40m.
I also acquired 3 boards to plug our current VMIPMC 5565 RFM cards into, so they can be installed in the IO chassis. These require +/- 5V power be connected to the top of the RFM board, which would be not possible in the 1U computers, so they have to go in the chassis. These style boards prevent the top of the chassis from being put on (not that Rolf or Jay have given me tops for the chassis). I'm planning on using the RFM cards from the East End FE, the LSC FE, and the ASC FE.
I talked to Jay, and offered to upgrade the old megatron IO chassis myself if that would speed things up. They have most of the parts, the only question being if Rolf has an extra timing board to put in it. Todd is putting together a set of instructions on how to put the IO chassis together and he said he'd give me a copy tomorrow or Monday. I'm currently planning on assembling it on Monday. At that point I only need 1 more IO chassis from Rolf.
NEW CDS SETUP CHANGE:
When I asked about the dolphin IO chassis, he said we're not planning on using dolphin connections between the chassis and computer anymore. Apparently there was some long distance telecon with the dolphin people and they said the Dolphin IO chassis connection and RFM doesn't well together (or something like that - it wasn't very clear from Rolf's description). Anyways, the other style apparently is now made in a fiber connected version (they weren't a year ago apparently), so he's ordered one. When I asked why only 1 and what about the IOO computer and chassis, he said that would either require moving the computer/chassis closer or getting another fiber connection (not cheap).
So the current thought I hashed out with Rolf briefly was:
We use one of the thin 1U computers and place that in the 1Y2 rack, to become the IOO machine. This lets us avoid needing a fiber. Megatron becomes the LSC/OAF machine, either staying in 1Y3 or possibly moving to 1Y4 depending on the maximum length of dolphin connection because LSC and the SUS machine are still supposed to be connected via the Dolphin switch, to test that topology.
I'm currently working on an update to my CDS diagram with these changes and will attach it to this post later today. |
3176
|
Thu Jul 8 14:11:16 2010 |
josephb | Update | Computers | Some channels not being recorded!!! |
This has been fixed, thanks to some help from Alex. It doesn't correspond to new computers being put in, but rather corresponds to a dcu_id change I had made in the new LSC model.
The fundamental problem is way back when I built the new LSC model using "lsc" as the name instead of something like "tst", I forgot to go to the current frame builder master file (/cvs/cds/caltech/chans/daq/master) and comment out the C1LSC.ini line. Initially there was no conflict with c1susvme, because the initially was dcu_id 13. The dcu_id was eventually changed to 10 from 13 , and thats when it conflicted with the c1susvme2 dcu_id which was also 10. I checked it against wiki edits to my dcu_id list page and I apparently updated the list on May 20th when it changed from 13 to 10, so the time frame fits. Apparently it was previously conflicting with C0GDS.ini or C1EXC.ini, which both seem to have dcu_id = 13 set, although the C1EXC file is all commented out. The C0GDS.ini file seems to be LSC and ASC test points only.
The solution was to comment out the C1LSC.ini file line in the /cvs/cds/caltech/chans/daq/master file and restart the framebuilder with the fixed file.
Quote: |
[Rana, Jenne]
We discovered to our great dismay that several important channels (namely C1:IOO-MC_L, but also everything on c1susvme2) are not being recorded, and haven't been since May 17th. This corresponds to the same day that some other upgrade computers were installed. Coincidence?
We've rebooted pretty much every FE computer and the FrameBuilder and DAQ_CONTROL approximately 18 times each (plus or minus some number). No matter what we do, or what channels we comment out of the C1SUS2.ini file, we get a Status on the DAQ_Detail screen for c1susvme2 of 0x1000. Except sometimes it is 0x2000. Anyhow, it's bad, and we can't make it good again.
I have emailed Joe about fixing this (with some assistance from Alberto, since we all know how much he likes doing the Nuclear Reboot option for the computers :)
|
|
3175
|
Wed Jul 7 23:11:08 2010 |
Koji | Update | IOO | MC alignment values. |
Hmm. I expect that you will put more details of the work tomorrow.
i.e. motivation, method, result (the previous entry is only this),
and some discussiona with how to do next.
Quote: |
Nancy and Koji:
This is what I and Koji measured after aligning the MC in the afternoon.
MC_Trans 4.595 (avg)
MC_Refl 0.203 (avg)
MC2_trans :
power = 1.34mW
13.5% width : x=6747.8 +- 20.7 um , y = 6699.4+- 20.7 um
|
|
3174
|
Wed Jul 7 22:58:08 2010 |
nancy | Update | IOO | MC alignment values. |
Nancy and Koji:
This is what I and Koji measured after aligning the MC in the afternoon.
MC_Trans 4.595 (avg)
MC_Refl 0.203 (avg)
MC2_trans :
power = 1.34mW
13.5% width : x=6747.8 +- 20.7 um , y = 6699.4+- 20.7 um
|
3173
|
Wed Jul 7 22:52:38 2010 |
rana, nancy | Configuration | IOO | bad length control offset for the MC |
Rana found out that a connection was bad in the shown place, due to which the MEDM screen was showing bad offset for length control.
Basically, the offset slider value would not go into the system because of that bad connection, and was locking the mode cleaner at the wrong location. |
Attachment 1: P7070251.jpg
|
|
Attachment 2: Screenshot.png
|
|
3172
|
Wed Jul 7 22:22:49 2010 |
Jenne | Update | Computers | Some channels not being recorded!!! |
[Rana, Jenne]
We discovered to our great dismay that several important channels (namely C1:IOO-MC_L, but also everything on c1susvme2) are not being recorded, and haven't been since May 17th. This corresponds to the same day that some other upgrade computers were installed. Coincidence?
We've rebooted pretty much every FE computer and the FrameBuilder and DAQ_CONTROL approximately 18 times each (plus or minus some number). No matter what we do, or what channels we comment out of the C1SUS2.ini file, we get a Status on the DAQ_Detail screen for c1susvme2 of 0x1000. Except sometimes it is 0x2000. Anyhow, it's bad, and we can't make it good again.
I have emailed Joe about fixing this (with some assistance from Alberto, since we all know how much he likes doing the Nuclear Reboot option for the computers :) |
3171
|
Wed Jul 7 19:41:27 2010 |
Jenne | Update | SUS | 1.5 more ECD sets suspended for tip tilts |
[Jenne, Kyung Ha]
We made some good progress on suspending the Tip Tilt ECDs today. We finished one whole set, plus another half. The half is because one of the screw holes on the lower right ECD somehow got cross threaded. The ECD and screws in question were separately wrapped in foil to mark them as iffy. We'll redo that second half tomorrow. This makes a total of 2.5 (including yesterday's work) ECD backplanes suspended. The only thing left for these ones is to trim up the excess wire.
We also (with Koji) took a look at the jig used for suspending the mirror holder. It looks like it was designed for so many Tip Tilt generations ago as to be basically useless for the 40m TTs. The only really useful thing we'll get out of it is the distance between the suspension block and the mirror holder clamps. Other than that we'll have to make do by holding the mirror and block at the correct distance apart, utilizing a ruler, calipers, or similar. Rana pointed out that we should slightly bend the blade springs up a bit, so that when they are holding the load of the mirror holder, they sit flat.
Attached below are 2 different pictures of one of the ECD backplane sets that has been suspended. One with black background to illustrate the general structure, and one with foil background to emphasize the wires. |
Attachment 1: ECDbackplane_blackdump_small.jpg
|
|
Attachment 2: ECDbackplane_foil_small.jpg
|
|
3170
|
Wed Jul 7 17:18:57 2010 |
Alberto | Configuration | Electronics | Stochmon and LSC AM Stabilizer Decomissioned |
Today I disconnected and removed the Stochmon box from the 1Y2 rack.
I also removed the amplifiers that were sitting on the PSL table, next to the RF AM PD, that were connected to the Stochmon. I pulled back the RG cable and the power cables that went from the PSL table to the 1Y1 and 1Y2 racks.
The power cable, all rolled up, is now sitting on the floor, inside the 1Y1 rack and one of its end is still connected to the power of the rack. We'd like to turn off the entire rack in order to safely remove it. But since the laser driver is there too, we should do it the first time we have to turn off the rack for some other reason.
I also removed two of the AM stabilizers from the 1Y2 rack. The other one, which is currently running th MC modulations, is still in the rack, and there it is going to remain together with its distribution box.
I stored both AM stabilizers and the Stochmon box inside the RF cabinet down the East arm. |
3169
|
Wed Jul 7 17:05:30 2010 |
steve, rana | Update | SAFETY | Summary of Crane Damage/Malfunction |
The 1 Ton yellow crane support beam jammed up at Friday morning, June 25.
The 40m vertex crane has a folding I-beam support to reach targeted areas. The rotating I-beam is 8 ft long. The folding extension arm gives you another 4 ft.
The 12 ft full reach can be achieved by a straightening of the 4 ft piece. There is a spring loaded latch on the top of the I-beam that locks down when the two I-beams align.
This lock joins the two beams into one rigid support beam for the jib trolley to travel. The position of this latch is visible when standing below, albeit not very well.
To be safe it is essential that this latch is locked down fully before a load is put on the crane.
We were preparing to pump down the 40m vacuum system on Friday morning. The straight alignment of the 8 and 4 ft piece made us believe that
the support beams were locked. In reality, the latch was not locked down. The jib trolley was driven to the end of the 12 ft I-beam. The 200 lbs ITM-east door was lifted
when the 4 ft section folded 50 degrees around the pivot point. This load of door + jib-trolley + 4 ft I-beam made the support beam sag about 6 inches
The door was removed from the jib hoist with the blue Genie-lift. The sagging was reduced to ~3".
The Genie-lift platform was raised to support the sagging crane jib-trolley. The lab was closed off to ensure safety and experts were called in for consultation. It was decided to bring in professional riggers.
Halbert Brothers, Inc. rigging contractor came to the lab Tuesday morning to fix the crane. The job was to unload the I-beam with safety support below. They did a very good job.
The static deformation of I-beams sprung back to normal position. There are some deformation of the I-beam ~2 mm where the beams were jammed under load.
It is not clear if this is a new deformation or if the crane sections have always been mis-aligned by a couple of mm.
The crane was tested with 450 lbs load at 12 ft horizontal travel position. The folding of I-beams were repeatedly tested for safe operation. Its a 1 ton crane, but we tested it with 450 lbs because that's what we had on hand.
We're working on the safety upgrade of this lift to prevent similar accident from happening.
Pictures below:
Atm 1) load testing 2007
Atm 2) jammed-sagging under ~400 lbs, horizontal
Atm.3) jammed-folded 50 degrees, vertical
Atm.4) static deformation of I-beams
Atm.5) unloading in progress with the help of two A-frames
Atm.6) it is unloaded
Atm.7-8) load testing
Atm.9) latch locked down for safe operation
Atm.9) zoom in of the crane sections misalignment |
Attachment 1: DSC_0026_00.JPG
|
|
Attachment 2: P1060408.JPG
|
|
Attachment 3: P1060415.JPG
|
|
Attachment 4: P1060413.JPG
|
|
Attachment 5: P1060421.JPG
|
|
Attachment 6: P1060423.JPG
|
|
Attachment 7: P1060441.JPG
|
|
Attachment 8: P1060436.JPG
|
|
Attachment 9: P1060425.JPG
|
|
Attachment 10: P1060432.JPG
|
|
3168
|
Wed Jul 7 12:45:00 2010 |
nancy | Update | | Weekly Update |
Wednesday after the meeting - Started report, learnt mode cleaner locking from Kiwamu and Rana, saw how to move optics on the tables with Rana and kiwamu.
Thursday - Made the report
Tuesday - report.
Today - am trying locking the MC with kiwamu's help to see the WFS signals and also to start characterizing the QPD. |
3167
|
Wed Jul 7 12:17:36 2010 |
Razib | Update | Phase Camera | Weekly update |
I have completed the following tasks:
1. Find a simplified calibration of the exposure time for the current He-Ne setup. Basically, I triggered the camera to take 20 snapshots with a 20 Hz driving signal at different exposure time beginning from 100 us (microsecond) upto 4000 us with an increment of 200 us.
Result: The current power allows the camera to have an exposure time of ~500 us before the DC level begans to saturate.
2. Aidan and I did some alignment and connected the AOM and corrected the driving frequency of its PZT to 40 Mhz(which apparently was disconnected which in turn gets the credit of NO beat signal for me until Tuesday 07/06/2010 5:30 PST) .
Result: I got the beat signal of 1 Hz and 5 Hz. Image follows (the colormap shows the power in arbitrary units).
3. Finished writing my Progress Report 1 .
 
|
Attachment 1: DC_1Hz_beat_sig.jpg
|
|
3166
|
Wed Jul 7 11:35:59 2010 |
Gopal | Update | WIKI-40M Update | 6.30.10 - 7.7.10 Weekly Update |
Summary of this Week's Activities:
6/30: 2nd and 3rd drafts of Progress Report
7/1: 4th draft and final drafts of Progress Report; submitted to SFP
7/5: Began working through busbar COMSOL example
7/6: LIGO meeting and lecture; meeting with Koji and Steve to find drawing of stacks; read through Giaime's thesis, Chapter 2 as well as two other relevant papers.
7/7: Continued working on busbar in COMSOL; should finish this as well as get good headway on stack design by the end of the day. |
3165
|
Wed Jul 7 11:23:08 2010 |
Sharmila, Katharine | Update | WIKI-40M Update | |
Weekly Update:
Last Weds-Thurs, we wrote and edited our progress reports.
Tuesday (and Weds morning): Continued circuit analysis of Haixing's circuit and plotting transfer functions (almost have one for entire circuit). Hooked up OSEM and circuit to power supply, but the LED didn't appear to light up in IR. Now we are going to hook the OSEM directly to the power supply, sans circuit, to see if the problem is with the circuit or OSEM. |
3164
|
Wed Jul 7 10:42:29 2010 |
Koji | Summary | PSL | power spectral density from RefCav transmitted beam |
How do you calibrate this to Hz/rtHz?
Quote: |
I measured the RC transmitted light signals here at the 40m. I made all connections through the PSL patch panel. No optics/PD were touched.
I measured the spectral density of the signal of the transmitted beam behind RefCav in both time and frequency domain.
This will be compared with the result from PSL lab later, so I can see how stable the signal should be.
We re-aligned the beam into the cavity (the DC level increased from 2 V to 3.83V)
and the reflected beam to the center of the RFPD.
|
|
3163
|
Wed Jul 7 00:15:29 2010 |
tara,Rana | Summary | PSL | power spectral density from RefCav transmitted beam |
I measured the RC transmitted light signals here at the 40m. I made all connections through the PSL patch panel.
Other than two steering mirrors in front of the periscope, and the steering mirror for the RFPD which were used to steer
the beam into the cavity and the RFPD respectively, no optics are adjusted.
We re-aligned the beam into the cavity (the DC level increased from 2 V to 3.83V) (Fig2) (We could not recover the power back to what it was 90 days ago)
and the reflected beam to the center of the RFPD.
I measured the spectral density of the signal of the transmitted beam behind RefCav in both time and frequency domain.
This will be compared with the result from PSL lab later, so I can see how stable the signal should be.
I did not convert Vrms/rtHz to Hz/rtHz because I only look at the relative intensity of the transmitted beam which will be compared to the setup at PSL lab.
We care about this power fluctuation because we plan to measure
photo refractive noise on the cavity's mirros
(this is the noise caused by dn/dT in the coatings and the substrate,
the absorption from fluctuating power on the coating/mirror changes
the temperature which eventually changes the effective length of the cavity as seen by the laser.)
The plan is to modulate the power of the beam going into the cavity,
the absorption from ac part will induce frequency noise which we want to see.
Since the transmitted power of the cavity is proportional to the power inside the cavity.
Fluctuations from other factors, for example, gain setting, will limit our measurement.
That's why we are concerned about the stability of the transmitted beam and made this measurement.
|
Attachment 1: RIN_rftrans.png
|
|
Attachment 2: tara.png
|
|
3162
|
Tue Jul 6 17:38:27 2010 |
Jenne | Update | SUS | Tip Tilt Progress! |
[Jenne, Kyung Ha]
We successfully suspended the 4 eddy current dampers for the first Tip Tilt. We had some lessons learned, including how to carefully get an allen wrench in between the dampers to do up some of the screws, and how to be careful not to bend the wire while tightening the screws. More tomorrow... |
3161
|
Tue Jul 6 17:29:04 2010 |
Chip | Update | PEM | The Ranger is mine! |
|
3160
|
Tue Jul 6 17:07:56 2010 |
josephb | Update | CDS | c1sus status |
I talked to Alex, and he explained the steps necessary to get the real time linux kernel installed. It basically went like copy the files from c1iscex (the one he installed last month) in the directory /opt/rtlidk-2.2 to the c1sus locally. Then go into rtlinux_kernel_2_6, and run make and make install (or something like that - need to look at the make file). Then edit the grub loader file to look like the one on c1iscex (located at /boot/grub/menu.lst).
This will then hopefully let us try out the RCG code on c1sus and see if it works. |
3159
|
Tue Jul 6 17:05:30 2010 |
Megan and Joe | Update | Computers | c1iovme reboot |
We rebooted c1iovme because the lines stopped responding to inputs on C1:I00-MC_DRUM1. This fixed the problem. |
3158
|
Tue Jul 6 11:57:06 2010 |
josephb | Update | CDS | Daily Downs Update |
I went to talk to Rolf and Jay this morning. I asked Rolf if a chassis was available, so he went over and disconnected one of his test stand chassis and gave it to me. It comes with a Contect DIO-1616L-PE Isolated Digital IO board and an OSS-MAX-EXP-ELB-C, which is a host interface board. The OSS board means it has to go into the south end station. There's a very short maximum cable length associated with that style, and the LSC and IOO chassis will be further than that from their computers (we have dolphin connectors on optical fiber for those connections).
I also asked Jay for another 4 port 37 d-sub ADC blue and gold adapter box, and he gave me the pieces. While over there, I took 2 flat back panels and punched them with approriate holes for the scsi connectors that I need to put in them. I still need to drill 4 holes in two chassis to mount the boards, and then a bit of screwing. Shouldn't take more than an hour to put them both together. At that point, we should have all the adapter boxes necessary for the base design. We still need some stuff for the green locking, as noted on Friday.
Major hardware still needed:
2 Dolphin style IO chassis
1 computer for south end front end |
3157
|
Fri Jul 2 11:33:15 2010 |
josephb | Update | CDS | c1sus needs real time linux to be setup on it |
I connected a monitor and keyboard to the new c1sus machine and discovered its not running RTL linux. I changed the root password to the usual, however, without help from Alex I don't know where to get the right version or how to install it, since it doesn't seem to have an obvious CD rom drive or the like. Hopefully Tuesday I can get Alex to come over and help with the setup of it, and the other 1-2 IO chassis. |
3156
|
Fri Jul 2 11:06:38 2010 |
josephb, kiwamu | Update | CDS | CDS and Green locking thoughts |
Kiwamu and I went through and looked at the spare channels available near the PSL table and at the ends.
First, I noticed I need another 4 DB37 ADC adapter box, since there's 3 Pentek ADCs there, which I don't think Jay realized.
PSL Green Locking
Anyways, in the IOO chassis that will put in, for the ADC we have a spare 8 channels which comes in the DB37 format. So one option, is build a 8 BNC converter, that plugs into that box.
The other option, is build 4-pin Lemo connectors and go in through the Sander box which currently goes to the 110B ADC, which has some spare channels.
For DAC at the PSL, the IOO chassis will have 8 spare channel DAC channels since there's only 1 Pentek DAC. This would be in a IDC40 cable format, since thats what the blue DAC adapter box takes. A 8 channel DAC box to 40 pin IDC would need to be built.
End Green Locking
The ends have 8 spare DAC channels, again 40 pin IDC cable. A box similar to the 8 channel DAC box for the PSL would need to be built.
The ends also have spare 4-pin Lemo capacity. It looked like there were 10 channels or so still unused. So lemo connections would need to be made. There doesn't appear to be any spare 37 DB connectors on the adapter box available, so lemo via the Sander box is the only way.
Notes
Joe needs to provide Kiwamu with cabling pin outs.
If Kiwamu makes a couple spares of the 8 BNC to 37DB connector boards, there's a spare 37DB ADC input in the SUS machine we could use up, providing 8 more channels for test use. |
3155
|
Thu Jul 1 17:05:36 2010 |
josephb, kiwamu, steve | Update | CDS | New SUS Chassis in rack |
Thanks to Steve's work on some L brackets, and Kiwamu's lifting help, we now have a new SUS IO chassis in the new 1X4 rack (formerly the 1Y4 rack), just below the new SUS and LSC computers. I have decided to call the sus machine, c1sus, and give it IP address 192.168.113.85. We also put in a host interface adapter, OSS-HIB2-PE1x4-1x4 Re-driver HIB, which connects the computer to the IO chassis.
The IP was added to the linux1 name server. However, the computer itself has not been configured yet. I'm hoping to come in for an hour or two tomorrow and get the computer hooked up to a monitor and keyboard and get its network connection working, mount /cvs/cds and get some basic RCG code running.
We also ran ethernet cables for the SUS machine to the router in 1X6 (formerly 1Y6) as well as a cable for megatron from 1X3 (formerly 1Y3) to the router, in anticipation of that move next week.
During the day, I realized we needed 2 more ADCs, one of which I got from Jay immediately. This is for two 110Bs and 4 Pentek ADCs. However, there's a 3rd 110B connected to c0dcu1 which goes to a BNC patch panel. Original Jay thought we would merge that into 4 pin lemo style into the 2nd 110B associated with the sus front ends. We've decided to get a another ADC and adapter. That will have to be ordered, and generally take 6-8 weeks. However, it may be possible to "borrow" one from another project until that comes in to "replace" it. This will leave us with our BNC patch panel and not force me to convert over 20 cables.
I also discovered we need one Contec DIO-1616L-PE Isolated Digital IO board for each Chassis, which I wasn't completely aware of. This is used to control the ADCs/DACs adapter boards in the chassis. It means we need still need to put a Binary Output board in the c1iscex chassis. Hopefully the chassis as they come in come from Downs continue to come with the Contec DIO-1616L-PE boards (they have so far).
The current loadout of the SUS chassis is as follows:
Treton Board
Far left slot, when looking from the front has the OSS-MAX-EXP-ELB-C board, used to communicate with the c1sus computer.
Slot 1 ADC PMC66-16AI6455A-64-50M
Slot 2 DAC PMC66-16AO16-16-F0-OF
Slot 3-6 BO Contec DIO-32L-PE Isolated Digital Output board
Slot 7 ADC PMC66-16AI6455A-64-50M
Slot 8-9 DAC PMC66-16AO16-16-F0-OF
Slot 10-11 ADC PMC66-16AI6455A-64-50M
Slot 12 Contect DIO-1616L-PE Isolated Digital IO board
Back Board
Slot 1 ADC adapter D0902006
Slot 2 DAC adapter D0902496-v1
Slot 7 ADC adapter D0902006
Slot 8-9 DAC adapter D0902496-v1
Slot 10-11 ADC adapter D0902006
|
3154
|
Thu Jul 1 14:28:39 2010 |
Jenne | Update | PEM | MC1 Accelerometers in place |
Kevin sent me an email with top secret info on where one of the other accelerometer cubes was hiding (it was with his shaker setup on the south side of the SP table), so I took it and put the 3 MC1 accelerometers in their 3-axis configuration.
Also, I changed the orientation of both sets of 3 axis accelerometers to reflect a Right Handed configuration, to go along with the new and improved IFO configuration. Previously (including last night), the MC2 accelerometers were together in a Left Handed configuration. |
3153
|
Thu Jul 1 14:03:40 2010 |
josephb | Update | PEM | Temporary disconnect of some PEM channels for ~20 minutes |
In order to identify the output adapter of the BNC patch panel used for about 20 PEM channels, I had to disconnect its power and remove the back panel. Channels coming into that panel (seismometers and so forth) was out from 1:36 to 1:56 pm.
I did a quick check of some of the channels and it looks like its working again after putting it all back together. |
3152
|
Thu Jul 1 10:26:34 2010 |
steve | Configuration | VAC | pd68 at vacuum normal state |
Slow pump down _pd68 has reached the vacuum normal state. CC4_Rga region is pumped now. The RGA is still off.
Precondition to this pump down: 129 days at atm, ITMs replaced. MMT, oplev and other components were removed from BSC, ITMCs. New MMT mirrors are in. IOO_access_connector was out. The end chambers were not opened.
|
Attachment 1: pd68slow2d.jpg
|
|
Attachment 2: pem134d.jpg
|
|
3151
|
Wed Jun 30 23:03:46 2010 |
rana | Configuration | IOO | Power into MC restored to max |
Kiwamu, Nancy, and I restored the power into the MC today:
- Changed the 2" dia. mirror ahead of the MC REFL RFPD back to the old R=10% mirror.
- Since the MC axis has changed, we had to redo the alignment of the optics in that area. Nearly all optics had to move by 1-2 cm.
- 2 of the main mounts there had the wrong handedness (e.g. the U100-A-LH instead of RH). We rotated them to some level of reasonableness.
- Tuned the penultimate waveplate on the PSL (ahead of the PBS) to maximize the transmission to the MC and to minimize the power in the PBS reject beam.
- MC_REFL DC =1.8 V.
- Beams aligned on WFS.
- MC mirrors alignment tweaked to maximize transmission. IN the morning we will check the whole A2L centering again. If its OK, fine. Otherwise, we'll restore the bias values and align the PSL beam to the MC via the persicope.
- waveplates and PBS in the PSL were NOT removed.
- MC TRANS camera and QPD have to be recentered after we are happy with the MC axis.
- MC REFL camera has to be restored.
- WFS measurements will commence after the SURF reports are submitted.
We found many dis-assembled Allen Key sets. Do not do this! Return tools to their proper places or else you are just wasting everyone's time!
|
3150
|
Wed Jun 30 18:16:55 2010 |
steve | Update | SAFETY | SURF safety training 2010 |
40m SURFs Razib Obaid, Nancy Aggarwal, Unknown Bearded SMURF, Megan Daily, Gopal Nataraj, Katharine Larson and Sharmila Dhevi received 40m specific safety training on June 23, 2010. |
Attachment 1: DSC_1902.JPG
|
|
3149
|
Wed Jun 30 17:30:54 2010 |
Jenne | Update | PEM | Seismometers moved for MC Wiener work |
Now that the MC is back up and running, I put the Guralp seismometers at the ends of the mode cleaner. Gur1 is near MC2, and Gur2 is near MC1 (yes, it seems backwards....that's how the cable lengths work). Also, the set of 3 MC2 accelerometers are in place under MC2. I can't find the black cube for the other set of accelerometers, so there aren't any around MC1/3. |
3148
|
Wed Jun 30 15:24:04 2010 |
steve,kiwamu | Update | VAC | slow pumpdown copmlete |
Quote: |

The pumpdown started at 4 PM (2300 UTC). At 10 PM, we (Jenne, Jan, and I) opened up the RV1 valve to full open. That's the second inflection point in the plot.
|
Atm 2 is showing the butterfly valve that closes down down the orifice at higher pressure to slow down the pumping speed.
See elog entry #2573
|
Attachment 1: slowpd.jpg
|
|
Attachment 2: butterfly.JPG
|
|
3147
|
Wed Jun 30 14:38:04 2010 |
Jenne | Update | PEM | Guralp terminator is switched |
I moved the Guralp box's input terminator from Gur1 to Gur2 a minute or so ago to check the other channels. |
3146
|
Wed Jun 30 12:20:49 2010 |
Razib | Update | Phase Camera | Weekly update |
This week I have completed following tasks:
1. Worked out the analytical expressions for the amount of power of the DC and oscillatory part going into the camera.
2. Realigned the He-Ne PhaseCam setup as we had to replace the first steering mirror after the laser with a silvered mirror ( one without a dielectric coating for 1064 nm).
3. Gone through the code written by a previous surfer (Zach Cummings).
4. Read the paper 'Real-time phase-front detector for heterodyne interferometers'- F. Cervantes et. el. where they talk about constructing a phase detector for LISA pathfinder mission. One interesting fact I found was that, they used InGaAs chip for their CCD Cam which has a amazing QE of 80% @ 1064 nm. Unfortunately, the one we are using (Micro MT9V022 CMOS) has only ~5% QE for 1064 nm and 50% for 633 nm. One top of it MT9V022 has a built-in infra-red filter infront of it to make it more insenstive to 1064. In such limitations, we may have to find a work-around for this issue. Any idea?
5. Read about the EOM and AOM and their vibrating (!) way to add on and alter the incident light on them. (Source: Intro to Optical Electronics-Yariv)
One task that we couldn't accomplish even though I planned on doing is:
1. Move,if possible, to the Nd:YAG setup.
Task for this week:
1. Produce breathtaking calibration of the camera at He-Ne setup.
2. Read 'Fringe Analysis'-Y.Surrel and 'Phase Lock Technique'-Gardner.
3. Modify the phasecam code.
4. Produce an alternate triggerbox using diodes instead of Op-Amp as op-amp is suspected to fail at some point driving the camera due to impedance mismatch.
5. Answer Koji's question at Aidan's ELOG . |
3145
|
Wed Jun 30 12:13:39 2010 |
Sharmila, Katharine | Update | WIKI-40M Update | weekly update |
Weekly Project Update:
We are studying Haixing's circuit diagram for the quadrant maglev control circuit. We have analyzed several of the sub-circuits and plotted transfer functions for these in MatLab. To check the circuit, we will compare the calculated transfer functions with those obtained from the HP control systems analyzer.
To learn how to use the control systems analyzer, we are reading App Note 243 as well as an online manual (477 pages in the first volume). We are beginning with a simple test circuit, and are comparing its measured frequencyresponse with calculated transfer functions. We currently have obtained a response graph beginning at 100 Hz (which we have not yet figured out how to print), and we are planning to investigate behavior at lower frequencies.
We also have been continuing our reading on control systems after a failed attempt at magnetic levitation. |
3144
|
Wed Jun 30 12:01:20 2010 |
josephb | Update | CDS | SUS IO Chassis |
I spent this morning populating the SUS IO Chassis and getting it ready for installation into the 1Y4 rack. I discovered I'm lacking the internal cables to connect the ADC/DAC boards to the AdL adapter boards that also go in the chassis (D0902006 and D0902496). I'm not sure where Alex got the cables he used for the end IO chassis he had put in. I'll be going to Downs after the meeting today either to get cables or parts for cables, and get the SUS chassis wired up fully.
I'd also like to confirm with Alex that the OSS-MAX-EXP-ELB-C board that goes in the IO chassis matches the host interface board that goes in the computer (OSS-HIB2-PE1x4-1x4 Re-driver HIB, since we spent half a day the last time we installed an IO chassis determining that one of the pair was bad or didn't match.
The SUS chassis has been populated in the following way:
Treton Board
Slot 1 ADC PMC66-16AI6455A-64-50M
Slot 2 DAC PMC66-16AO16-16-F0-OF
Slot 3-6 BO Contec DIO-1616L-PE Isolated Digital IO board
Slot 7 ADC PMC66-16AI6455A-64-50M
Slot 8-9 DAC PMC66-16AO16-16-F0-OF
Back Board
Slot 1 ADC adapter D0902006
Slot 2 DAC adapter D0902496-v1
Slot 7 ADC adapter D0902006
Slot 8-9 DAC adapter D0902496-v1 |
3143
|
Wed Jun 30 11:39:20 2010 |
nancy | Update | WIKI-40M Update | Weekly Update |
Wednesday Morning E-log :
Most of the time through this week, i was working towards making the simulink model work.
It involved learning simulink functions better, and also improving on the knowledge of control theory in general, and control theory of our system.
1. Thusrday : found tfs for the feedback loop. and tried many different filters and gains to stabilize the system (using the transient response of the system). - not through
2. Friday : decided to use error response and nullify the steady state error instead of looking at convergence of output. tried many other filter functions for that.
Rana then showed me his files for WFS.
3. Sunday - played with rana's files, learnt how to club simluink with matlab, and also about how to plot tfs using bode plots in matlab.
4. Monday : Read about state-space models, and also how to linearize in matlab. done with the latter, but the former still needs deeper understanding.
read ray-optics theory to calculate the geometric sensing matrix.
It first requires to calculate the eigen mode of the cavity with tilted mirrors. this eigen mode is needed to be found out using ray-optics transfer matrices for the optics involved . figured out matrices for the tilted plane mirrors, and am working on computing the same for MC2.
5. Tuesday : went to Universal Studios , Hollywood :P
6. Wednesday (today) : Writing the report to be submitted to SFP. |
3142
|
Wed Jun 30 11:35:06 2010 |
Gopal | Update | General | 6.23.10 - 6.30.10 Weekly Update |
Summary of this Week's Activities:
6/23: LIGO Safety Tour; Simulink Controls Tutorial
6/24: Simulink Diagram for Feedback Loop; Constructed Pendulum Transfer Function; Discussion with Dr. Weinstein
6/25: Prepare for pump-down of vacuum chamber; crane broken due to locking failure; worked through COMSOL tutorials
6/28: Ran through Python Tutorials; Began learning about Terminal
6/29: Wrote Progress Report 1 First Draft
6/30: Began editing Progress Report 1 |
3141
|
Wed Jun 30 00:45:26 2010 |
rana | Update | VAC | slow pumpdown stopped for the night |
As per Steve's instructions, at 12:43 AM, I used the following steps to stop the pumpdown until the morning:
- Close RV1 using the 'steering-wheel' wrench.
- Close V3.
- Turn OFF RP1.
- Disconnect RP1 hose at the plastic disconnect attached to the slow-start throttle valve.
|
3140
|
Tue Jun 29 23:49:18 2010 |
steve, rana | Update | VAC | slow pumpdown started |

The pumpdown started at 4 PM (2300 UTC). At 10 PM, we (Jenne, Jan, and I) opened up the RV1 valve to full open. That's the second inflection point in the plot. |
3139
|
Tue Jun 29 20:47:19 2010 |
Jenne | Update | PEM | Terminator put on Guralp Box |
A little D-sub terminator was put on the Gur1 input to the Guralp box, to check again the noise level of the box. |
3138
|
Tue Jun 29 17:10:49 2010 |
steve, rana | Update | VAC | slow pumpdown started |
The folding crane was fixed and tested this morning by the NNN rigging company. Pictures will be posted by Steve in the morning.
Afterwards, the ITM-east door was installed, jam-nuts checked. No high voltage was on for the in-vac PZTs.
The annulus spaces were roughed down to 350mTorr by Roughing Pump RP1. For this operation, we removed the low flow valve from the RP1 line.
After the spaces came down to ~400 mTorr, we closed their individual valves.
Warning: The VABSSC1 and VABSSC0 valves are incorrect and misleadingly drawn on the Vacuum overview screen.
We then:
- Closed V6 (valve between RP1 and the annulus line).
- Turned off RP1 from the MEDM screen.
- Installed the soft -starting butterfly valve.
- Turned on RP1.
- Opened V3.
- Closed VV1 (at the last minute - this is a vent valve and must be checked before each pumpdown)
- and pumpdown was started with a 3/4 turn opening of manual valve RV1.
Our idea is to have a much slower pumpdown this time than the last time when we had a hurricane kick up the dust. Looks like it worked, but next time we should do only 1/2 turn. |