1938
|
Tue Aug 25 00:35:04 2009 |
rana | Update | General | Transfer function of Mode Cleaner Stacks |
Looks like all of the accelerometers and seismometers have been disconnected since early AM last Monday when Clara disconnected them for her sensor noise measurement. |
Attachment 1: Untitled.png
|
|
1937
|
Mon Aug 24 16:48:57 2009 |
steve | HowTo | VAC | new UPS installed |
Quote: |
As Rob noted last Friday, the UPS which powers the Vacuum rack failed. When we were trying to move the plugs around to debug it, it made a sizzling sound and a pop. Bad smells came out of it.
Ben came over this week and measured the quiescent power consumption. The low power draw level was 11.9 A and during the reboot its 12.2 A. He measured this by ??? (Rob inserts method here).
So what we want is a 120 V * 12.2 A ~ 1.4 kVA UPS with ~30-50% margin. We look for this on the APC-UPS site:
On Monday, we will order the SUA2200 from APC. It should last for ~25 minutes during an outage. Its $1300. The next step down is $200 cheaper and gives 10 minutes less uptime.
|
The new APC Smart -UPS 2200VA is now running at the vacuum rack. There are 2 load monitoring leds on out of 5
Maglev, dry pumps and roughing pumps are not using UPS.
The switch over went smoothly with Yoichi's help.
First we closed all vacuum valves and stopped the two small turbos.
Than turned power off to instruments in the vac-rack and VME: c1vac1 & c1vac2
Maglev was left running.
Now we moved the AC plugs from the wall receptacles over to the back of the UPS and powered them up.
Varian turbos were restarted and vacuum valves were restored in order to reach vacuum normal condition.
See 40m Vacuum System States and Sequences Manual of 10-24-2001
Linux 3 desk top computer is out of order at the pump spool. We should replace it.
The vacuum control screen can be pulled up on a lap top: /cvs/cds/caltech/medm/c0/ve/VacControl_BAK.adj
|
1936
|
Mon Aug 24 10:43:27 2009 |
Alberto | Omnistructure | Computers | RFM Network Failure |
This morning I found that all the front end computers down. A failure of the RFM network drove all the computers down.
I was about to restart them all, but it wasn't necessary. After I power cycled and restarted C1SOSVME all the other computers and RFM network came back to their green status on the MEDM screen. After that I just had to reset and then restart C1SUSVME1/2. |
1935
|
Fri Aug 21 18:37:16 2009 |
Jenne | Update | General | Transfer function of Mode Cleaner Stacks |
Using free-swinging Mode Cleaner OSEM data and Guralp seismometers, I have taken transfer functions of the Mode Cleaner stacks.
During this experiment, the MC was unlocked overnight, and one Guralp seismometer was underneath each chamber (MC1/MC3, and MC2). Clara will let me know what the orientation of the seismometers were (including which seismometer was underneath which chamber and what direction the seismometer axes were pointing), but for now I have included TFs for every combination of suspension motion and seismometer channels.
I combined the 4 OSEM channels for each optic in POS and PIT, and then calibrated each of my sus channels using the method described in Kakeru's elog entry 1413. Units are meters for POS, and radians for PIT. I also calibrated the guralp channels into meters.
The traces on each plot are: MC_{POS or PIT} / Guralp_{1 or 2}_{direction}. So each plot shows the coupling between every seismometer direction and a single mirror direction. The colors are the same for all the plots, ie the gold trace is always Gur1Z. |
Attachment 1: TF_osems_guralps.png
|
|
1934
|
Fri Aug 21 17:49:47 2009 |
Yoichi | Summary | Computers | Upgrade FE conceptual plan |
I started to draw a conceptual diagram of the upgraded FE system.
http://nodus.ligo.caltech.edu:30888/FE/FE-Layout.html
(It takes some time to load the page for the first time)
Some places, tips will pop up when you stop the cursor over an object.
You can also click on the LSC block to see inside.
This is just a start point, so we should add more details.
The source of the diagrams are in the svn:
https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/FE/
I used yEd (http://www.yworks.com/en/products_yed_about.html) to make
the drawings. It is Java, so works on many platforms. |
Attachment 1: Picture_2.png
|
|
1933
|
Fri Aug 21 17:28:50 2009 |
Kevin, rana | Summary | PEM | Magnetic Field Measurements Around the Lab |
This goal of this test was to measure and map the AC (at 60 Hz) and DC magnetic fields around the interferometer. I've attached the final products which were drawn up with Google SketchUp.
The notes on the maps make them more or less self explanatory: for each numbered point there's an X, Y, and Z measurement produced by the magnetometer. For the AC numbers I measured the Peak-to-Peak value, while for the DC I simply measured the Mean. The magnetometer's axes were always oriented about the same way, with the X arrow on the magnetometer pointing north. I tried to keep variables such as the lights constant as much as possible (they were all on for most measurements, with the exception of a few noted DC ones) and all measurements had the top of the magnetometer at about 32 inches. The map is pretty close to scale and all the walls and numbered locations were measured out (though the location of objects and the laser tubes is somewhat estimated). I added "landmarks" in the room, which were pretty much the laser tubes, computer racks, and ISC tables.
For each laser room measurement I also took a screenshot using the oscilloscope as a means of recording the shape of the wave for each measurement. Ch1 corresponds to the X value, Ch2 to the Y, and Ch3 to the Z. The screenshots are numbered 1-29 corresponding to the numbers on the map. The zip folders containing the screenshots can be found on the wiki: PEM:Magnetometers
I should also mention that there is no point #24 and accordingly no 24 screenshot. I realized after I was done that I had messed up the location of that one and instead of risking bad data decided to just remove it.
I decided on the location of the points mainly based on the location of outlets in the room (since I had to plug in the oscilloscope for the AC numbers to set it to 60 Hz). After an initial pass of the room, I went back and filled in some of the larger gaps by moving the magnetometer as far as I could while the oscilloscope remained plugged in to the wall. I used the same points for DC numbers.
Prior to measuring the laser room, I measured the field in other rooms as well. I have
-
AC numbers and screenshots for the control room and the adjoining office room.
-
DC numbers for the entry room and the office room, not including the control room. The X-axis arrow is pointed south (instead of north) for these numbers.
These numbers were sort of a warm up for me to figure out the process and how I would go about recording my data. Since they're not in really important locations and aren't guaranteed to be accurate, I decided not to map them, though the screenshots are still on this Dell Inspiron 1300 Laptop and the measurements in my notebook.
Here are the settings I used on the oscilloscope for all measurements (I merely changed the Vertical Coupling between DC and AC depending on what I was measuring):
The notebook that I used contains some additional info that I didn't include in the map, most importantly more precise descriptions of where each of the points is located and the measured distance between each of them (as well as slight changes I made to my measured distances in order to make the room a rectangle; the changes are slight enough that they shouldn't have any real effect on the data).
Since Kevin used our 3-axis Bartington Fluxgate magnetometer, we can guess that we can convert his voltage measurements (below) into magnetic field
by using the manual's guess of 10 uT /V or 10 V/Gauss. This is probably ok at the factor of 2 level, but one day we should calibrate it with a coil.
The punchline is that the DC fields in the lab are roughly what we expect from the Earth's field plus the rebar in our floors: ~1 Gauss. The 60 Hz fields are ~50-500 nT peak-peak. |
Attachment 1: AC-field.png
|
|
Attachment 2: DC-field.png
|
|
1932
|
Fri Aug 21 17:05:04 2009 |
Jenne | Update | General | restarted the elog |
[Kevin, Jenne]
Kevin's awesome final report/elog entry was so awesome that it crashed the elog. It has been restarted. We're going to put his pictures and documentation in the wiki, with a link from the elog to prevent re-crashing. |
1931
|
Thu Aug 20 09:16:32 2009 |
steve | HowTo | Photos | Control Room Workstation desks lowered to human height |
Quote: |
There were no injuries...Now we need to get some new chairs.
|
The control room desk tops heights on the east side were lowered by 127 mm
|
Attachment 1: P1040788.png
|
|
Attachment 2: P1040782.png
|
|
Attachment 3: P1040786.png
|
|
Attachment 4: P1040789.png
|
|
Attachment 5: P1040785.png
|
|
1930
|
Wed Aug 19 23:57:35 2009 |
rob | Update | Locking | report |
locking work proceeding apace tonight.
diagonalized DRM with setDDphases & senseDRM.
initial locks are fairly quick, aqstep script succeeds reliably.
first part of cm_step (handoff CARM-> MCL) usually works.
tuning up later parts of cm_step (presumably due to optical gain changes resulting from MOPA decline).
got to arm powers ~60. |
1929
|
Wed Aug 19 18:02:22 2009 |
Jenne | Update | LSC | RF PDs aligned |
All of the LSC RF PDs have been aligned. I didn't really change much of anything, since for all of them, the beam was already pretty close to center. But they all got the treatment of attaching a Voltmeter to the DC out, and adjusting the steering mirror in both pitch and yaw, finding where you fall off the PD in each direction, and then leave the optic in the middle of the two 'edges'.
Before aligning each set (PO, Refl, AS), I followed the procedure in Rob's new RF photodiode Wiki Page.
Also, for superstitious reasons, and in case I actually bumped them, I squished all of the ribbon cable connectors into the PDs, just in case. |
1928
|
Wed Aug 19 17:11:33 2009 |
Jenne | Update | IOO | QPDs aligned |
Quote: |
If Rob/Yoichi say the alignment is now good, the we absolutely must center the IOO QPDs and IP POS and IP ANG and MC TRANS today so that we have good references.
|
IOO_QPD_POS, IOO_QPD_ANG, MC_TRANS, IP_POS, IP_ANG have all been centered.
Also, the MCWFS have been centered.
I'm now working on making sure beam is hitting all of the RF PDs around. |
1927
|
Wed Aug 19 02:17:52 2009 |
rana | Omnistructure | Environment | Control Room Workstation desks lowered to human height |
There were no injuries...Now we need to get some new chairs. |
1926
|
Tue Aug 18 19:57:47 2009 |
rana, Jenne | Update | PSL | MZ |
- we finished the MZ alignment; the contrast is good.
- we did the RFAM tuning using a new technique: a bubble balanced analyzer cube and the StochMon RFPD. This techniques worked well and there's basically no 33 or 166 RFAM. The 133 and 199 are as expected.
- the MC locked right up and then we used the periscope to align to it; the transmission was ~75% of max before periscope tuning. So the beam pointing after the MC should be fine now.
- the Xarm locked up with TRX = 0.97 (no xarm alignment).
If Rob/Yoichi say the alignment is now good, the we absolutely must center the IOO QPDs and IP POS and IP ANG and MC TRANS today so that we have good references.
-----------------------------------
The first photo is of our nifty new setup to get the beam to the StochMon PD. The MZ transmitted beam enters the photo from the bottom right corner, and hits the PBS (which we leveled using a bubble level). The P-polarization light is transmitted through the cube, and the S-polarization is reflected to the left. The pure S-polarized light hits a Beam Splitter, which we are using as a pickoff to reduce the amount of light which gets to the PD. Most of the light is dumped on an aluminum dump. The remaining light hits a steering mirror (Y1 45-S), goes through a lens, and then hits the StochMon PD. While aligning the MZ to maximize visibility, we look at the small amount of P-polarized light which passes through the PBS on an IR card, and minimize it (since we want to be sending purely S-polarized light through the EOMs and into the MC).
The second photo is of a spectrum analyzer which is directly connected to the RF out of the StochMon PD. To minimize the 33MHz and 166MHz peaks, we adjust the waveplates before each of the EOMs, and also adjusted the tilt of the EOM holders.
The final photo is of the EOMs themselves with the Olympus camera.
Once we finished all of our MZ aligning, we noticed that the beam input to the MC wasn't perfect, so Rana adjusted the lower periscope mirror to get the pointing a little better.
The MZ refl is now at 0.300 when locked. When Rana reduced the modulation depth, the MZ refl was about 0.050 . Awesome!
|
Attachment 1: MZ_RFAMmon_setup_small.jpg
|
|
Attachment 2: MZ_RFAMmon_SpecAnalyzer_small.jpg
|
|
Attachment 3: MZ_EOM_IRrefl2_small.jpg
|
|
1925
|
Tue Aug 18 15:52:27 2009 |
Jenne | Update | PSL | MZ |
I tweaked up the MZ alignment. The reflection had been around 0.550, which kept the MEDM indicator green, but was still too high. I fiddled with BS1, and a little bit with BS2. When I had the doors of the PSL table open, I got as low as 0.320. When I closed up and came back to the control room, the MZ refl had drifted up to 0.354. But it's good again now.
In the future, mirrors shouldn't be so close together that you can't get at their knobs to adjust them No good. I ended up blocking the beam coming out of the PMC to prevent sticking my hand in some beam, making the adjustment, then removing the dump. It worked in a safe way, but it was obnoxious. |
1924
|
Tue Aug 18 15:16:15 2009 |
rob | Update | IOO | MC WFS working again |
Rob, Yoichi
The MC WFS have apparently been bad for a few days, causing the MC alignment to drift away at DC. We tried a few things to fix it, including jiggling some EPICS settings in the WFS head & demod screens. This seemed to work for WFS1 but not WFS2. Confused, we decided to go stare at the rack 1Y2. While doing that, we noticed that the top two Sorensens in 1Y1 (these are directly below the Guralp box) were at different voltages from nominal. The 5V had dropped to 4.2V and the 24V was at 24.6V. We adjusted the knobs until these were set correctly. After this, the MC WFS appear to work again.
When working in a rack, you must be as careful about accidentally touching things as when working on an optical table. |
1923
|
Tue Aug 18 14:24:43 2009 |
Yoichi | Summary | PSL | Reference Cavity Inspection |
Rana, Koji, Yoichi
To see why the reflected beam from the RC is distorted, we took out
the periscope and the iris in front of the RC. The periscope mirrors
had some gunk and dusts on them. We blew nitrogen air onto them to
remove the dust. Since the gunk did not come off with the air, we
wrapped a Q-tip with lens cleaning paper soaked in Methanol, and wiped
the surface of the mirrors. We did this because it was hard to remove
the mirrors from the periscope (they were in a spring loaded mirror
holders. The springs were too strong to safely remove them without
damaging the mirrors).
Looking into the RC from the front mirror revealed nothing obstructing
in the path.
After the cleaning, we put the periscope back and observed the direct
reflection from the cavity (not locked). It was still distorted
exactly like before.
So we did some tests.
First we injected He-Ne to the RC. It turned out that multiple
reflections from the optical window (not AR coated for He-Ne) made it
almost impossible to investigate anything with He-Ne. But this
observation made us to suspect maybe one side of the window is not AR
coated.
We placed the periscope about 50cm away from the RC and injected the
beam from an angle, so that we can observe the direct reflection.
First, we checked the shape of the beam leaving the periscope. It was good.
We then observed the reflected beam from the RC. It was also good, no distortion.
We made sure that it was really the reflection from the mirror, not from the window
as follows.
We measured the separation between the in coming beam to the cavity and the reflected beam
at two locations. From this, we can guess where the two beams intersect (the reflection point).
The estimated reflection point was far inside the RC enclosure, indicating that it was really
reflection from the front mirror of the RC.
Since we did not see any other reflection beam, we concluded that the AR coating of the window
is good.
We checked the direct reflection beam shape with several different incident angles, but the
beam shape was always good.
We put back the periscope to the original position. This time, we put a high reflectivity mirror
after the output mirror of the periscope. The beam coming out of the circulator (PBS) had a good
circular shape. But still if we let the beam reflected by the cavity, the beam shape is distorted.
Something must be happening in the RC. Unfortunately, we could not figure out what it is.
We put everything back to the original configuration, except for the iris, and the RC alignment
was already good (surprise). After Koji's final tweak, the FSS is now doing fine, but still
the reflected beam is ugly. |
1922
|
Tue Aug 18 01:16:01 2009 |
Jenne | Update | PSL | Mach Zehnder is realigned |
The Mach Zehnder and I got to know each other today. The reason for redoing the alignment was to improve pointing from the PSL table into the MC/IFO in hopes that this would solve the MC unlocking problems that we've been having lately. Since Rana had aligned the IOO QPDs a few weeks ago when all of the alignments and things were good, I used them as a reference for my Mach Zehnder alignment activities.
The order of operations were approximately as follows:
1. Block the secondary (west) arm of the Mach Zehnder using either an aluminum or razor dump.
2. Use SM1 in the MZ to align the beam to the IOO_QPDs (Pos and Ang). I unfortunately also touched BS2 at this juncture, which made the refl path no longer a reference.
3. Make sure that the QPD Sum on both Pos and Ang was sensible. Since there are 2 beamsplitters in a Mach Zehnder, the power on the QPDs should be a quarter when only one beam is on them. Be careful not to allow the beam no clip on anything. The biggest problem was the bottom periscope mirror - if you hit it too high or too low, since it is a very thick optic, you end up coming out its side! This is the frosty part on the edges, totally inappropriate for beams to go through! Since the side of the periscope mirror isn't HR coated, when going through it like this, I was able to saturate the QPDs. Not so good.
4. Also, make sure that this first beam is on the MZ Refl PD. Do this using the steering optics after the beam has left the MZ. Use a viewer to look at the PD, and see the small spot of the beam on the diode. We closed the iris which is present and was standing fully open to remove a spurious beam which was a parallel split-off of the main beam. Since it was very weak, it is fine.
5. Unblock the west arm, and block the east arm of the MZ.
6. Align this arm to both the IOO QPDs and the MZ refl diode using the adjustments on BS1, the PZT mirror and if necessary, BS2. Note that the adjust knobs on the PZT mirror have lock screws. Make sure to unlock them before adjusting, and relock afterward, to avoid slipping while the PZT is moving.
7. Unblock all the beams, and make sure there is only one spot both on the transmission side and the reflection side, i.e. the 2 spots from the 2 arms are completely overlapping. For the Trans side, make sure to look both in the near field and the far field (even after the periscope) to ensure that you really have one spot, instead of just the 2 spots crossing at a single location.
8. Look at the MZ refl DC out and the PD out from the ISS box (which is essentially MZ trans, looking at Morag and Siobhan) on a 'scope.
9. Touch / gently wiggle BS1 or another optic, and watch the 'scope. At the same time, adjust BS1, the PZT mirror and BS2 to maximize the contrast between light and dark fringes. Ideally, the refl PD should go almost to zero at the dark fringes.
10. Check that you still have only one overlapping beam everywhere, and that you're actually hitting the MZ refl PD.
11. Because I was concerned about clipping while still figuring out the status of the lower periscope mirror, I removed the beam pipe holders between the last optic before the periscope, and the lower periscope mirror. The beam pipe had already been removed, this was just the pedestals and the snap-in clamps.
All done for now! Still to be done: Optimize the position of the EOMs. There is a waveplate out front and the EOMs are mounted in such a way that they can be moved in several directions, so that we can optimize the alignment into them. They ideally only should see a single polarization, in order to apply solely a phase modulation on the beam. If the input polarization isn't correct, then we'll get a bit of amplitude modulation as well, which on PDs looks like a cavity length change. Also, the little blue pomona-type box which has the RF signals for the EOMs needs to be clamped to the table with a dog clamp, or better yet needs to be moved underneath the PSL table, with just the cables coming up to the EOMs. The SMA connections and the SMA cable kept interfering with the MZ refl beam...it's a wonder anyone ever made the beam snake around those cables the way they were in the first place. Right now, the box is sitting just off the side of the table, just inside the doors.
Something else that Rana and I did while on the table: We moved the PMC trans optics just a teensy bit toward the PSL door (to the east) to avoid coming so unbelievably close to the MZ refl optics. The PMC trans beam shown in the lowest part of my sketch was very nearly clipping on the MZ refl steering optic just near it. This situation isn't totally ideal, since (as it has been in the past), the first optic which is dedicated to the PMC trans isn't fully sitting on the PSL table. The pedestal needs to hang off the edge of the table a bit to keep this beam from clipping. Unfortunately there really isn't space to make a better beam path. Since we're planning on getting rid of the MZ when the upgrade happens, and this isn't causing us noticeable trouble right now, we're going to let it stay the way it is.
Also, we dumped the reflection from the PMC RFPD onto a razor blade dump. And we noticed that the PZT mirror and BS2 in the MZ are badly vibrationally sensitive. BS2 has a ~400 Hz resonance (which is OK) but a ~150 ms ringdown time!! PZT mirror is similar.
Q = pi * f * tau = 200! Needs some damping. |
Attachment 1: MachZehnderOptics2.pdf
|
|
1921
|
Mon Aug 17 17:48:49 2009 |
rob | Summary | General | conlogger restarted |
Quote: |
I restarted the conlogger on op340m. This needs to be done when op340m is rebooted--it wasn't done for some reason and so we've lost several days of controls records.
|
I added a cronjob on op340m to check every half-hour if the conlog is running, and if not, restart it. |
1920
|
Mon Aug 17 17:43:11 2009 |
rana | Summary | General | conlogger restarted |
Added the conlog directory to the SVN, minus the enormous data directory. We are now free to make changes to the conlog code. |
1919
|
Mon Aug 17 09:52:04 2009 |
rob | Summary | General | conlogger restarted |
I restarted the conlogger on op340m. This needs to be done when op340m is rebooted--it wasn't done for some reason and so we've lost several days of controls records. |
1918
|
Mon Aug 17 07:01:09 2009 |
Clara | Update | PEM | ADC noiseness |
I shorted the inputs on three channels and the outputs on three channels of the Guralp box, and I did similar things with the accelerometers. I was going to move the instruments themselves back, but I didn't have time, so they are still in the box in the corner. If the setup could stay as-is for at least a few hours, that would be awesome. |
1917
|
Mon Aug 17 04:16:13 2009 |
Yoichi | Update | PSL | Reference cavity reflection looks bad |
Quote: | Rana, Yoichi
- We also moved the Refcav reflection camera to look at the leakage through a reflection steering mirror so that there's less chance of distortion. There was previously a W1 window in there as a pickofff. Also changed the camera to autogain so that we can see something.
- Re-aligned onto the refl pd.
- Tweaked alignment into RC. Mainly in yaw. Transmission went from 5V to 7V. In your face, Aso!
|
After our removal of the pick off window and Rana's re-alignment of the beam into the RC, the RC optical gain increased.
FSS was complaining about it by driving the PC feedback crazy.
I reduced the nominal common gain from 12.5dB to 11dB. |
1916
|
Mon Aug 17 02:12:53 2009 |
Yoichi | Summary | Computers | FE bootfest |
Rana, Yoichi
All the FE computers went red this evening.
We power cycled all of them.
They are all green now.
Not related to this, the CRT display of op540m is not working since Friday night.
We are not sure if it is the failure of the display or the graphics card.
Rana started alarm handler on the LCD display as a temporary measure. |
1915
|
Mon Aug 17 02:05:49 2009 |
Yoichi,rana | Update | PSL | Reference cavity reflection looks bad |
Rana, Yoichi
It has been a well known fact that the reference cavity reflection beam looks ugly.
We measured the visibility of the RC by locking and unlocking it.
Comparing the reflected beam powers, we got the visibility of 0.46,
which is pretty bad.
The beam going into the RC looks fine (circular on a sensor card).
However, the beam reflected back from the RC is distorted into a
horizontal ellipse, even when the RC is not locked.
We took a picture of the reflected beam hitting a white paper with the
infrared camera (see the attachment). It looks like two overlapping
circles horizontally separated. Could it be a badly coated optics
producing a secondary reflection ?
We looked into the RC's front mirror with an inspection mirror, but we
could not identify any obstructing object.
Rana is now touching the RC alignment.
We plan to remove the periscope before the RC to have a better look
into the cavity for inspection.
Late breaking update:
- We also moved the Refcav reflection camera to look at the leakage through a reflection steering mirror so that there's less chance of distortion. There was previously a W1 window in there as a pickofff. Also changed the camera to autogain so that we can see something.
- Re-aligned onto the refl pd.
- Tweaked alignment into RC. Mainly in yaw. Transmission went from 5V to 7V. In your face, Aso! |
Attachment 1: P8170113.JPG
|
|
Attachment 2: Untitled.png
|
|
1914
|
Sun Aug 16 04:33:11 2009 |
Clara | Update | Locking | Mode Cleaner is out of lock again |
Quote:
|
It was fine when I came in earlier today, but I just got back from dinner, and it's not good. I looked in dataviewer, and it seems to have been sliding out for the past couple of hours... Here is a picture:

I swear I am not responsible this time... all I've been doing is working in the control room.
|
Mode cleaner bounced back on its own about 2 hours ago. |
1913
|
Sat Aug 15 22:50:18 2009 |
Clara | Update | Locking | Mode Cleaner is out of lock again |
It was fine when I came in earlier today, but I just got back from dinner, and it's not good. I looked in dataviewer, and it seems to have been sliding out for the past couple of hours... Here is a picture:

I swear I am not responsible this time... all I've been doing is working in the control room. |
1912
|
Sat Aug 15 18:57:48 2009 |
rana | Update | VAC | UPS failed |
As Rob noted last Friday, the UPS which powers the Vacuum rack failed. When we were trying to move the plugs around to debug it, it made a sizzling sound and a pop. Bad smells came out of it.
Ben came over this week and measured the quiescent power consumption. The low power draw level was 11.9 A and during the reboot its 12.2 A. He measured this by ??? (Rob inserts method here).
So what we want is a 120 V * 12.2 A ~ 1.4 kVA UPS with ~30-50% margin. We look for this on the APC-UPS site:
On Monday, we will order the SUA2200 from APC. It should last for ~25 minutes during an outage. Its $1300. The next step down is $200 cheaper and gives 10 minutes less uptime. |
1911
|
Sat Aug 15 18:35:14 2009 |
Clara | Frogs | Computers | How far back is complete data really saved? (or, is the cake a lie?) |
I was told that, as of last weekend, we now have the capability to save full data for a month, whereas before it was something like 3 days. However, my attempts to get the data from the accidentally-shorted EW2 channel in the Guralp box have all been epic failures. My other data is okay, despite my not saving it for several days after it was recorded. So, my question is, how long can the data actually be saved, and when did the saving capability change? |
1910
|
Sat Aug 15 10:36:02 2009 |
Alan | HowTo | Computers | nodus boot procedure |
fb40m was also rebooted. I restarted the ssh-agent for backup of minute-trend and /cvs/cds. |
1909
|
Sat Aug 15 05:08:55 2009 |
Yoichi | Update | Locking | Friday night locking |
Summary: DD hand off fails for DRFPMI.
Tonight, I did a lot of house keeping work.
(1) I noticed that the reference cavity (RC) was locked to TEM10.
This was probably the reason why we had to increase the FSS common gain.
I re-locked the RC to TEM00. Now the common gain value is back to the original.
(2) The MC WFS did not engage. I found that c1dcuepics had the /cvs/cds mounting problem.
I rebooted it. Then MC WFS started working.
(3) After checking that the MC WFS QPDs are centered for direct reflection (the MZ half fringe method),
I locked the MC and tweaked the mirror alignment (mainly MC3) to offload the WFS feedback signals.
Now the MC locks to TEM00 robustly.
(4) Since the MC mirror alignment is touchy recently, I did not like the idea of mis-aligning MC2
when you do the LSC PD offset adjustment. So I modified the LSCoffset script so that it will close
the PSL shutter instead of mis-aligning MC2.
(5) I changed the PD11_Q criteria for success in the alignment scripts because PD11_Q is now lower
than before due to the lower laser power.
(6) Since today's bootfest, some epics values were not properly restored. Some of the PD gains were
unmatched between I and Q. I corrected these with the help of conlog.
(7) By checking the open loop TFs, I found that the short DOFs have significantly lower UGFs than before,
probably due to the lower laser power. I increased the gains of MICH, PRCL and SRCL by a factor of 2 for
the full configuration.
For the DRM configuration the changes I made were:
PRC -0.15 -> -0.3
SRC 0.2 -> 0.6
MICH 0.5 -> 0.5
(8) I locked the DRFPMI with arm offsets, then adjusted the demodulation phases of PD6,PD7,PD8 and PD9 (DD PDs)
to minimize the offsets in the error signal, while locked with the single demodulation signals.
Change log:
PD6_PHASE 201 -> 270
PD7_PHASE 120 -> 105
PD8_PHASE 131 -> 145
PD9_PHASE -45 -> -65
(9) I ran senseDRM to get the sensing Matrix for the short DOFs using DD signals in DRM configuration.
(10) Still the DD hand off fails for DRFPMI. It succeeds for DRM. |
1908
|
Fri Aug 14 23:45:14 2009 |
Chris | Update | General | Long Range Readout |
The EUCLID-style Michelson readout is on the SP table now and is aligned. See image below. I took several power spectra with the plotter attached to the HP3563 (not sure if there's another way to get the data out) and I'm still waiting to calibrate (since dP/dL isn't constant as it isn't locked, this is taking a bit longer). When put into XY mode on the oscilliscope (plotting Voltage at PD2 on the x and Voltage at PD3 on the y), a Lissajous figure as in the first plot below. It's offset and elliptical due to imperfections (noise, dc offset, etc) but can ideally be used to calculate the L_ target mirror movement. By rotating the first quarter wave plate by ~80.5deg counter-clockwise (fast axis was originally at Pi/8, now at 103deg), I was able to turn the Lissajous figure from an ellipse into a more circular shape, which would ideally allow for us to use a circular approximation (much simpler) in our displacement calculations. |
Attachment 1: Table_Setup.png
|
|
Attachment 2: Ellipse.jpg
|
|
Attachment 3: Circle.jpg
|
|
1907
|
Fri Aug 14 18:33:02 2009 |
Clara | Update | | Record of Accelerometer and Seismometer Movements |
Rather than make a new elog post every time I move something, I'm going to just keep updating this Google spreadsheet, which ought to republish every time I change it. It's already got everything I've done for the past week-ish. The spreadsheet can be accessed here, as a website, or here, as a pdf. I will still post something nightly so that you don't have to search for this post, but I wanted to be able to provide more-or-less real-time information on where things are without carpet-bombing the elog. |
1906
|
Fri Aug 14 15:32:50 2009 |
Yoichi | HowTo | Computers | nodus boot procedure |
The restart procedures for the various processes running on nodus are explained here:
http://lhocds.ligo-wa.caltech.edu:8000/40m/Computer_Restart_Procedures#nodus
Please go through those steps when you reboot nodus, or notice it rebooted then elog it.
I did these this time. |
1905
|
Fri Aug 14 15:29:43 2009 |
Jenne | Update | Computers | c1susvme2 was unmounted from /cvs/cds |
When I came in earlier today, I noticed that c1susvme2 was red on the DAQ screens. Since the vme computers always seem to be happier as a set, I hit the physical reset buttons on sosvme, susvme1 and susvme2. I then did the telnet or ssh in as appropriate for each computer in turn. sosvme and susvme1 came back just fine. However, I couldn't cd to /cvs/cds/caltech/target/c1susvme2 while ssh-ed in to susvme2. I could cd to /cvs/cds, and then did an ls, and it came back totally blank. There was nothing at all in the folder.
Yoichi showed me how to do 'df' to figure out what filesystems are mounted, and it looked as though the filesystem was mounted. But then Yoichi tried to unmount the filesystem, and it claimed that it wasn't mounted at all. We then remounted the filesystem, and things were good again. I was able to continue the regular restart procedure, and the computer is back up again.
Recap: c1susvme2 mysteriously got unmounted from /cvs/cds! But it's back, and the computers are all good again. |
1904
|
Fri Aug 14 15:20:42 2009 |
josephb | Summary | Computers | Linux1 now has 1.5 TB raid drive |
Quote: |
Quote: |
nodus was rebooted by Alex at Fri Aug 14 13:53. I launched elogd.
cd /export/elog/elog-2.7.5/
./elogd -p 8080 -c /export/elog/elog-2.7.5/elogd.cfg -D
|
It looks like Alex also rebooted all of the control room computers. Or something. The alarm handler and strip tool aren't running.....after I fix susvme2 (which was down when I got in earlier today), I'll figure out how to restart those.
|
Alex switched the mount point for /cvs/cds on Linux1 to the 1.5 TB RAID array after he finished copying the data from old drives. This required a reboot of linux1, with all the resulting /cvs/cds mount points on the other computers becoming stale. Easiest way to fix that he found was to do a reboot of all the control room machines. In addition, a reboot fest should probably happen in the near futuer for all the front end machines since they will also have stale mount points as well from linux1.
The 1.5 TB RAID array mount is now mounted on /home of linux1, which was the old mount point of the ~300 GB drive. The old drive is now at /oldhome on linux1.
|
1903
|
Fri Aug 14 14:33:51 2009 |
Jenne | Summary | Computers | nodus rebooted |
Quote: |
nodus was rebooted by Alex at Fri Aug 14 13:53. I launched elogd.
cd /export/elog/elog-2.7.5/
./elogd -p 8080 -c /export/elog/elog-2.7.5/elogd.cfg -D
|
It looks like Alex also rebooted all of the control room computers. Or something. The alarm handler and strip tool aren't running.....after I fix susvme2 (which was down when I got in earlier today), I'll figure out how to restart those. |
1902
|
Fri Aug 14 14:19:25 2009 |
Koji | Summary | Computers | nodus rebooted |
nodus was rebooted by Alex at Fri Aug 14 13:53. I launched elogd.
cd /export/elog/elog-2.7.5/
./elogd -p 8080 -c /export/elog/elog-2.7.5/elogd.cfg -D |
1901
|
Fri Aug 14 10:39:50 2009 |
josephb | Configuration | Computers | Raid update to Framebuilder (specs) |
The RAID array servicing the Frame builder was finally switched over to JetStor Sata 16 Bay raid array. Each bay contains a 1 TB drive. The raid is configured such that 13 TB is available, and the rest is used for fault protection.
The old Fibrenetix FX-606-U4, a 5 bay raid array which only had 1.5 TB space, has been moved over to linux1 and will be used to store /cvs/cds/.
This upgrade provides an increase in look up times from 3-4 days for all channels out to about 30 days. Final copying of old data occured on August 5th, 2009, and was switched over on that date. |
1900
|
Fri Aug 14 02:57:46 2009 |
Clara | Update | PEM | Redo of the Huddle Test |
I put all three seismometers and all six accelerometers together in the foam box with peanuts. Three of the accelerometers are facing in the x-direction and three are in the y-direction. Both Guralps are aligned on the NS axis and the Ranger is pointing vertically.
**EDIT: The accelerometers are in the x and z directions, not x and y. Sorry, I was sleepy when I wrote this.**
One of the accelerometers was refusing to show anything, and after a few hours of checking connections and swapping cables, I discovered that someone had unplugged the cable from the ADC. A quick glance in the dataviewer shows that the channel has been unplugged since about 3 in the afternoon on August 8th (Saturday). So... obviously all the accelerometer measurements made with that channel since then did not actually get recorded. Yay.
Anyway, as of 2:45, everything is working and taking data. Clearly we're not getting a full night's worth... hopefully that's okay. |
1899
|
Thu Aug 13 22:53:48 2009 |
Yoichi | Configuration | PSL | FSS nominal common gain changed, MC WFS centered |
Koji, Yoichi
We found that the FSS PC feedback easily goes crazy (saturated).
It was because the common gain was too low. Probably the recent decrease of the
laser power is responsible for this.
We increased the nominal value of the common gain from 12 to 16.5.
The value was chosen just to make the PC path quiet. We should check
the FSS UGF later.
The MC WFS QPDs seemed off centered. So we unlocked the MC and lowered
the input power by the usual MZ half fringe technique.
Actually, the direct reflection beam was not much off the center. In anyway, we adjusted
the beam to the exact center of the QPDs.
The MC now locks fine.
|
1898
|
Thu Aug 13 11:20:43 2009 |
janosch | HowTo | PEM | three-channel self-noise estimation |
There are two new Matlab files on the svn in /mDV/extra/C1. 'mycsd.m' is to calculate the cross-spectral density between two channels, 'csd_40T_40T_SS1.m' calls this function with the available seismic channels and derives a self-noise spectrum for the vertical axis using all three seismometers. The method requires that there are no correlations between two instruments only which is a bad idealization for certain frequencies if you have seismometers of totally different types.
'mycsd.m' uses the high-gain, low-resolution Nuttall window (built-in Matlab function 'nuttallwin.m'). High-gain windows are used for broad-band spectra like seismic spectra, but it should be exchanged by another window if you plan to look at small-bandwidth features like peaks.
Since the three-channel analysis does not require knowledge of response functions, it could be used to evaluate the performance of the adaptive filter. For example, if three channels responding to the same signal are available, then the ratio of any two csds corresponds to one of the relative transfer functions. You can then compare this function with the result produced by the adaptive filter. |
1897
|
Thu Aug 13 09:22:06 2009 |
rana | Update | PEM | ranger |
Rana, Jan, Jenne
We noticed that the Ranger data was all bogus at low frequencies. So we checked it and found that the proper procedure had not been used when changing it from horizontal to vertical last week. So the huddle test data from the weekend is not valid for the ranger; we will have to repeat it sometime.
So we used the manual, and extended the hanger rod on top of the Ranger to free the mass. It now has good response and coherence with the Guralps down to 0.1 Hz. See attached plot soon.
|
1896
|
Thu Aug 13 02:17:56 2009 |
Jenne | Update | IOO | Mode Cleaner Alignment |
When Rob and I were getting started on locking for the evening, Mode Cleaner lost lock a few times, but every time it lost lock, it took forever to reaquire, and was pretty insistent on locking in the TEM10 mode. I proposed that the alignment might be sketchy. I've been fiddling with the MC alignment sliders for the last hour and a half or so, but I think I'm not 100% in tune with the 3 mirror parameter space. The mode cleaner now locks, but I'm not in love with its' alignment. The WFS are definitely catywhompus. Before doing hardware things like recentering the WFS, I'm going to wait until tomorrow to consult with an alignment expert.
In case this is helpful for tomorrow, before I touched any of the sliders:
Optic, Pitch, Yaw
MC1, 3.1459, -0.7200
MC3, -0.8168, -3.0700
MC2, 3.6360, -1.0576
Now that mode cleaner locks, although not in a great alignment:
MC1, 3.1089, -0.7320
MC3, -0.7508, -3.0770
MC2, 3.6610, -1.0786
If I knew how to kill my script to unlock the mode cleaner, I would. But I sourced it, and Rob didn't know earlier this evening how to kill something which is started with 'source' since it doesn't seem to get a process number like when you './' to run a script. So the Mode Cleaner will probably be unlocked in the morning, and it may be persnickity to get it relocked, especially if the tree people are doing tree things with giant trucks again in the morning. |
1895
|
Thu Aug 13 00:11:43 2009 |
Jenne | Update | IOO | Mode Cleaner Unlock |
So that I can collect a bit of free-swinging Mode Cleaner data, I started a script to wait 14400 seconds (4 hours), then unlock the mode cleaner. It should unlock the MC around 4am. As soon as someone gets in in the morning, you can relock it. I should have plenty of data by then. |
1894
|
Wed Aug 12 23:45:03 2009 |
Chris | Update | General | Long range michelson |
Today I set up the EUCLID long range michelson design on the SP table; It's the same as the setup posted earlier, but without the pickoff (at PD1), which can be added later, and a few other minor changes (moved lenses, mirrors, PDs - nothing major). I hooked up the two PD's to the oscilliscope and got a readout that pointed to more power hitting PD2 than PD3. |
Attachment 1: Actual_Sensor.png
|
|
1893
|
Wed Aug 12 15:02:33 2009 |
Alberto | Configuration | Computers | elog restarted |
In the last hour or so the elog crashed. I have restarted it. |
1892
|
Wed Aug 12 13:35:03 2009 |
josephb, Alex | Configuration | Computers | Tested old Framebuilder 1.5 TB raid array on Linux1 |
Yesterday, Alex attached the old frame builder 1.5 TB raid array to linux1, and tested to make sure it would work on linux1.
This morning he tried to start a copy of the current /cvs/cds structure, however realized at the rate it was going it would take it roughly 5 hours, so he stopped.
Currently, it is planned to perform this copy on this coming Friday morning. |
1891
|
Wed Aug 12 12:08:16 2009 |
Stephanie | Update | General | Multiply Resonant EOM Update |
I measured the magnitude of modulation as a function of frequency using the optical spectrum analyzer and an oscilloscope while generating signals using a Marconi signal generator; the results are shown in the attached plot and are compared to the expected modulation given the measured transfer function of the circuit and the nominal modulation index of the EOM used (13 mrad/V). Using the oscilloscope, I found the resonant peaks to be at 11.11 MHz, 29.57 MHz, and 54.70 MHz. There are several different colors on the plot; this is because I had to take the data in several different segments and had to switch to measuring a different sideband partway through the measurment. I also separately found the modulation at each resonant peak for each sideband. The magnitude of modulation was measured by finding the ratio between the magnitude of the carrier and sideband powers using an oscilloscope, and calculating the magnitude of modulation from this. This method was also used to quantify the dependence of modulation magnitude on input power at each resonant peak; these results are also attached. These same results can also be plotted as modulation magnitude as a function of voltage into the resonant circuit; this is also attached (I'm not sure which is more useful).
In order to produce these results (get the measurements in mrad/V) it was necessary to measure the gain of the amplifier. I used the signal generator to input signals of varying power and measured the output signal voltage using the oscilloscope; I then repeated this process at each resonant frequency. From this I was able to calculate the gain of the amplifier to be 28.1 dB at 11.11 MHz, 27.4 dB at 29.57 MHz, and 25.7 dB at 54.70 MHz. These values are in the same ballpark as the values in the Mini Circuits data sheet (all values are ~25-28 MHz). |
Attachment 1: Modulation.png
|
|
Attachment 2: Linearity.png
|
|
Attachment 3: Linearity_V.png
|
|
1890
|
Wed Aug 12 10:35:17 2009 |
jenne | Summary | Computers | Nodus rebooted / SVN down |
Quote: |
Looks like someone rebooted nodus at ~3 PM today but did not elog it. Also the SVN is not running. Why?
|
The Nodus business was me....my bad. Nodus and the elog were both having a bad day (we couldn't ssh into nodus from op440m (which doesn't depend on the names server)), so I called Alex, and he fixed things, although I think that all he did was reboot. I then restarted the elog per the instructions on the wiki.
|
1889
|
Wed Aug 12 02:00:32 2009 |
rob | Update | Locking | report |
Spent a lot of time aligning tonight. The BS is not staying put--sometimes after a lock loss it gets badly mis-aligned.
DD handoff is working, after putting beam on REFL diodes and running senseDRM script. |