ID |
Date |
Author |
Type |
Category |
Subject |
13835
|
Fri May 11 19:02:52 2018 |
gautam | Update | General | More refinement of DARM control signal projection |
I was a bit hasty in posting the earlier plots. In the earlier plot, the "OLG" trace was OLG * anti dewhitening as Rana pointed out.
Here are the updated ones, and a cartoon (Attachment #5) of the loop topology I assumed. I've excluded things like violin filters, AA/AI etc. The overall gain scaling I mentioned in the previous elog amounts to changing the optical sensing response in this cartoon. I now also show the DARM suppression (Attachment #4) for this OLG and the DARM linewidths for RSE. I don't think the conclusions change.
Note that for Signal Recycling, which is what Kevin tells us we need to do, there is a DARM pole at ~150 Hz. I assume we will cancel this in the digital controller and so can achieve a similar OLG shape. This would modify the control signal spectrum a little around 150Hz. But for a UGF on the loop of ~150 Hz, we should still be able to roll-off the control signal at high frequencies and so the RMS shouldn't be dramatically affected.
Steve is looking into acquiring 4.5kohm Vishay Wirewound resistors with 1% tolerance. Plan is to install two in parallel (so that we get 2kohm effective resistance) and then snip off one once we are convinced we won't have any actuation range issues. Do these look okay? They're ~$1.50ea on mouser assuming we get 100. Do we need the non-inductive winding?
Quote: |
I think "OLG" trace is not labeled right; it would be good to see the actual OLG in addition to whatever that trace actually is.
|
|
Attachment 1: darmProj.pdf
|
|
Attachment 2: darmOLTF.pdf
|
|
Attachment 3: DWcomparison.pdf
|
|
Attachment 4: DARMsuppression.pdf
|
|
Attachment 5: ControlLoop.pdf
|
|
13837
|
Sun May 13 15:15:18 2018 |
gautam | Update | General | CDS crash |
I found the c1lsc machine to be completely unresponsive today. Looking at the trend of the state word, it happened sometime yesterday (Saturday). The usual reboot procedure did not work - I am not able to bring back any of the models on any of the machines, during the restart procedure, they all fail. The logfile reads (for the c1ioo front end, but they all behave the same):
[ 309.783460] c1x03: Initializing space for daqLib buffers
[ 309.887357] CPU 2 is now offline
[ 309.887422] c1x03: Sync source = 4
[ 309.887425] c1x03: Waiting for EPICS BURT Restore = 2
[ 309.946320] c1x03: Waiting for EPICS BURT 0
[ 309.946320] c1x03: BURT Restore Complete
[ 309.946320] c1x03: Corrupted Epics data: module=0 filter=1 filterType=0 filtSections=134610112
[ 309.946320] c1x03: Filter module init failed, exiting
[ 363.229086] c1x03: Setting stop_working_threads to 1
[ 364.232148] DXH Adapter 0 : BROADCAST - dx_user_mcast_unbind - mcgroupid=0x3
[ 364.233689] Will bring back CPU 2
[ 365.236674] Booting Node 1 Processor 2 APIC 0x2
[ 365.236771] smpboot cpu 2: start_ip = 9a000
[ 309.946320] Calibrating delay loop (skipped) already calibrated this CPU
[ 365.251060] NMI watchdog enabled, takes one hw-pmu counter.
[ 365.252135] Brought the CPU back up
[ 365.252138] c1x03: Just before returning from cleanup_module for c1x03
Not sure what is going on here, or what "Corrutped EPICS data" is supposed to mean. Thinking that something was messed up the last time the model was compiled, I tried recompiling the IOP model. But I'm not able to even compile the model, it fails giving the error message
make[1]: Leaving directory '/opt/rtcds/caltech/c1/rtbuild/3.4'
make[1]: /cvs/cds/rtapps/epics-3.14.12.2_long/modules/seq/bin/linux-x86_64/snc: Command not found
make[1]: *** [build/c1x03epics/c1x03.c] Error 127
Makefile:28: recipe for target 'c1x03' failed
make: *** [c1x03] Error 1
I suspect this is some kind of path problem - the EPICS_BASE bash variable is set to /cvs/cds/rtapps/epics-3.14.12.2_long/base on the FEs, while /cvs isn't even mounted on the FEs (nor do I think it should be). I think the correct path should be /opt/rtapps/epics-3.14.12.2_long/base. Why should this have changed?
I've shutdown all watchdogs until this is resolved. |
Attachment 1: vertexFEs_crashed.png
|
|
13838
|
Sun May 13 17:31:51 2018 |
gautam | Update | General | CDS crash |
As suspected, this was indeed a path problem. Johannes will elog about it later, but in short, it is related to some path variables being changed in order to try and streamline the EPICS processes on the new c1auxex machine (Acromag Era). It is confusing that futzing around with the slow computing system messes with the realtime system as well - aren't these supposed to be decoupled? Once the paths were restored by Johannes, everything compiled and restarted fine. We even have a beam on the AS camera, which was what triggered this whole thing .
Anyways, Attachment #1 shows the current status. I am puzzled by the red TIMING indicators on the c1x04 and c1x02 processes, it is absent from any other processes. How can this be debugged further?
Quote: |
I suspect this is some kind of path problem - the EPICS_BASE bash variable is set to /cvs/cds/rtapps/epics-3.14.12.2_long/base on the FEs, while /cvs isn't even mounted on the FEs (nor do I think it should be). I think the correct path should be /opt/rtapps/epics-3.14.12.2_long/base. Why should this have changed?
|
|
Attachment 1: CDS_overview_20180513.png
|
|
Attachment 2: AS_1210293643.jpeg
|
|
13845
|
Tue May 15 20:51:27 2018 |
gautam | Configuration | Electronics | Making PLL setup more permanent |
[jon, steve, gautam]
Some points which Jon will elaborate upon (and put photos of) in his detailed elog about this setup:
- PLL electronics (mixer, coupler, ZFL500HLN amplifier and DC power supply for the beatnote, SR560 servo) all reside on the newly installed lower level PSL shelf.
- Cross connect channel C1:PSL-126MOPA_126CURADJ hijacked for remote temperature control of the AUX NPRO. Note that shield of front panel BNC is ground and so even though the manual says the controller accepts +/-10V, this is not a differential input. BNC cable was routed from cross connect to PSL enclosure, MEDM slider will be setup.
- There was an SMA cable running from the VEA to the control room which we decided to use for monitoring of the beatnote amplitude on the control room analyzer. Yesterday, Steve and I routed the end of this inside the VEA, near 1X2 originally, to inside the PSL table where it is hooked up to the (20dB) coupled amplifier output. This required some work on the cable tray, we were careful but in case there is some wonkiness in some signals, perhaps this work is to blame.
We are now in a state where the PLL can be locked remotely from the control room by tweaking the AUX laser temperature . Tomorrow, Keerthana will work on getting Craig's/Johannes' Digital Frequency Counter script working here, I think we can easily implement a PLL autolocker if we have some diagostic that tells us if the PLL us locked or not.
Steve informed me that there is an acoustic hum inside the PSL enclosure which wasn't there before. Indeed, it is at ~295Hz, and is from the Bench power supply used to power the ZFL500HLN amplifier. This will have to go... |
13846
|
Tue May 15 21:56:57 2018 |
gautam | Update | General | Stack measurement setup decommissioned |
[steve,koji,gautam]
Since we think we already know the stack mass to ~25% (i.e. 5000 +/- 1000 lbs), we decided to restore the ETMX stack. Procedure followed was:
- Take photos of all dial indicators and spirit level. We were at ~-22 mils on all 3 indicators, with 0 being the level before we touched the stack two Fridays ago, i.e. May4.
- Raised all four jacks installed underneat blue crossbeams in 5mil increments until we were at +25mils on all of them. At this point, there was negligible load on the load cells on top of the STACIS legs, and we could easily slide the load cells out.
- Rotated all jack screws clockwise (i.e. moving jack screws downwards) by 270 degrees. The southeast jackscrew was rotated by an additional 360 degrees. This was to undo all the jack-screw raising we did on Friday, May 4.
- Re-installed jacks which were present originally on the STACIS legs, taking care to center the jack as best as we could by eye on the STACIS leg, per Dennis Coyne's suggestion not to impose shear strain on STACIS legs. There were supposedly never carrying any load, and are according to Steve, are there more for safety purposes.
- Lowered all four jacks in 5 mil steps until dial indicators read ~0. The Northwest jack resting on the STACIS leg was somehow ~0.5cm (!!) below the blue crossbeam even though the corresponding dial gauge read 0, so we raised the jack until it was barely grazing the bottom of the blue crossbeam (confirmed by looking at the point where the dial indicator started going up again). Not sure why this should have been, best hypothesis we have is that someone (one of us) changed the level of this jack while it was removed from the setup.
- Checked that jack screws could not be turned by hand. At this point, all the load has to be resting on the jack screws, as the jacks we had installed to raise the blue crossbeams could be slid out from underneath the blue beams and hence were carrying no load.
- Took photographs of all dial indicators, spirit level. We were satisfied that we had recovered the "nominal" stack alignment as best as we could judge with the available indicators.
- ETMX Oplev spot had returned to the PD. ETMX watchdog was re-engaged, optic was re-aligned using SLOW bias sliders to center Oplev spot.
- EX NPRO was turned back on, and the green beam was readily locked to a cavity TEM00 mode
.
I will upload the photos to the PICASA page and post the link here later.
Quote: |
In this case, we only need a mass estimate of the end chamber contents with an accuracy of ~25%. If we think we have that already, we don't need to keep doing the jacks-strain gauge adventure.
|
|
13847
|
Tue May 15 22:11:38 2018 |
gautam | Update | General | IFO maintenance |
Since there have been various software/hardware activity going on (stack weighing, AUX laser PLL, computing timing errors etc etc), I decided to do a check on the state of the IFO.
- c1susaux, c1aux and c1iscaux crates were keyed as they were un-telnet-able.
- Single arm locking worked fine, TT alignment was tweaked (as these had drifted due to the ADC failure in c1lsc) to maximize Y arm transmission using the dither servos.
- Arms weren't staying locked for extended periods of time. I particularly suspected ITMX, as I saw what I judged to be excess motion on the Oplev.
- @Steve - ITMX and BS HeNes look like they are in need of replacement judging by the RIN (although the trend data doesn't show any precipitous drop in power). If we are replacing the BS/PRM Oplev HeNe, might be a good time to plan the inejction path a bit better on that table.
- RIN in Attachment #1 has been normalized by the mean value of the OL sum channel. There is now a script to make this kind of plot from NDS in the scripts directory (as I found it confusing to apply different calibrations to individual traces in DTT).
|
Attachment 1: OL_RIN_2018_05_15.pdf
|
|
Attachment 2: OLsums.png
|
|
13848
|
Wed May 16 18:52:50 2018 |
gautam | Configuration | Electronics | PLL mysteries solved |
[Koji, Gautam]
Summary:
As I suspected, when the SR560 is operated in 1 Hz, first order LPF mode, the (electronic) transfer function has a zero at ~5kHz (!!!).
Details:
This is what allowed the PLL to be locked with this setting with UGF of ~30kHz. On the evidence of Attachment #3, there is also some flattening of the electrical TF at low frequencies when the SR560 is driving the NPRO PZT. I'm pretty sure the flattening is not a data download error but since this issue needs further investigation anyway, I'm not reading too much into it. I fit the model with LISO but since we don't have low frequency (~1Hz) data, the fit isn't great, so I'm excluding it from the plots.
We also did some PLL loop characterization. We decided that the higher output range (10Vp bs 10Vpp for the SR560) of the LB1005 controller means it is a better option for the PLL. The lock state can also be triggered remotely. It was locked with UGF ~ 60kHz, PM ~45deg.
We also measured the actuation coefficient of the NPRO laser PZT to be 4.89 +/- 0.02 MHz/V. Quoted error is (1-sigma) from the fit of the linear part of the measured transfer function to a single pole at DC with unknown gain. I used the "clean" part of the measurement that extends to lower frequencies for the fit, as can be seen from the residuals plot. Good to know that even though the LDs are dying, the PZT is still going strong :D.
Remaining loop characterization (i.e. verification of correct scaling of in loop suppression with loop gain etc.) is left to Jon.
Measurement schemes:
- OLG (Attachment #1) was measured using the usual IN1/IN2 technique.
- PZT calibration (Attachment #2) was measured by injecting an excitation at the PLL control point.
- The ratio of the PLL error point (Volts) to Excitation (Volts) was measured using the SR785.
- The error point was calibrated by looking at the PLL open loop Vpp (corresponds to pi radians of phase shift).
- Dividing the fitted gain of the phase->Frequency conversion by the error point calibration, we get the PZT actuation coefficient.
Some other remarks:
- In the swept-sine mode, the SR785 measures transfer functions by taking the ratio of complex FFT values of its inputs at the drive frequency. So the phase in particular is a good indicator of whether the measurement is coherent or not.
- In all these measurements, the PLL gain is huge at low frequencies, and hence, the excitation is completely squished on propagating through the loop. E.g. a 10mV excitation is suppressed by a factor of ~60dB = 1000 to 10uV, and if the analyzer autoRange is set to UpOnly, it is easy to see how this is drowned at the IN1 input. This is why the measurements lose coherence below ~1 kHz.
- It is easy to imagine implementing an EPICS servo that offloads the DC part of the LB box control signal to the SLOW frequency input on the Lightwave controller. This would presumably allow us to extend the lock timescales. We can also easily implement a PLL autolocker.
- Preliminary investigation of the SR560 situation suggests that individual filter stages can only achieve a maximum stopband attenuation of 60dB relative to the passband. When we cascade two stages together, 120dB seems possible...
|
Attachment 1: PLLanalysis.pdf
|
|
Attachment 2: PZTcal.pdf
|
|
Attachment 3: SR560_funkiness.pdf
|
|
13852
|
Thu May 17 11:56:37 2018 |
gautam | Update | General | EPICS process died on c1ioo |
The EPICS process on the c1ioo front end had died mysteriously. As a result, MC autolocker wasn't working, since the autolocker control variables are EPICS channels defined in the c1ioo model. I restarted the model, and now MCautolocker works. |
13860
|
Thu May 17 18:05:01 2018 |
gautam | Update | SUS | SR785 near 1X5 |
I'm working near 1X5 and there is an SR785 adjacent to the electronics rack with some cabling running along the floor. I plan to continue in the evening so please leave the setup as is.
During the course of this work, I noticed the +15V Sorensen in 1X6 has 6.8 A of current draw, while Steve's February2018 label says the current draw is 8.6A. Is this just a typo?
Steve: It was most likely my mistake. Tag is corrected to 6.8A
I'm still in the process of electronics characterization, so the SR785 is still hooked up. MC3 coil driver signal is broken out to measure the output voltage going to the coil (via Gainx100 SR560 Preamp), but MC is locked. |
Attachment 1: B55CE985-B703-4282-B716-3144957C7372.jpeg
|
|
13863
|
Fri May 18 14:18:03 2018 |
gautam | Configuration | Electronics | Basic MEDM Control Screen setup |
I setup a basic MEDM screen for remote control of the PLL.
The Slow control voltage slider allows the frequency of the laser to be moved around via the front panel slow control BNC.
The TTL signal slider provides 0/5V to allow triggering of the servo. Eventually this functionality will be transferred to the buttons (which do not work for now).
The screen can be accessed from the PSL dropdown menu in sitemap. We can make this better eventually, but this should suffice for initial setup. |
Attachment 1: AUX_PLL_CTRL.png
|
|
13870
|
Sun May 20 23:43:50 2018 |
gautam | Update | IOO | Coil driver noise re-measurement |
Summary:
In the IMC actuation chain, it looks like the MC1/MC3 de-whitening boards, and also all three MC optics' coil driver boards, are showing higher noise than expected from LISO modeling. One possible candidate is thick film resistors on the coil driver boards. The plan is to debug these further by pulling the board out of the Eurocrate and investigating on the electronics bench.
Why bother? Mainly because I want to see how good the IR ALS noise is, and currently, the PSL frequency noise is causing the measurement to be worse than references taken from previous known good times.
Details:
Sometime ago, rana suggested to me that I should do this measurement more systematically.
- Attachments #1, #2 and #3 show noise measurements in various conditions for MC1, MC2 and MC3 respectively.
- In the above three attachments, I stitched together multiple spans from the SR785, and so the bin-width is different. The data is downloaded from the analyzer normalized by the bin-width (PSD units).
- The roll-off at ~800Hz in the orange trace for MC1 and MC3 is consistent with an 800 Hz LPF that was used for anti-image filtering from the old 2 kHz era.
- While it may look like the analog de-whitening isn't being switched on in some of these plots, I confirmed by transfer function measurement that it is indeed switching.
- Data used to make these plots are in Attachment #4. Unfortunately, the code requires some of my personal plotting libraries
and so I'm not uploading it.
- Sketch of measurement setup is shown in Attachment #5. It is not indicated in the schematic, but the SR560 was operated in battery mode for this measurement.
- For MC1, I did the additional measurement of terminating the LEMO input to the coil driver and measuring (what should have been) just the coil driver electronics noise. But this measurement doesn't look very clean, and hence, the decision to pull the board out to continue debugging.
- While at 1X6, Rana tightened the LEMO connectors going to MC1. We should opportunistically do MC2 and MC3 as well.
- Some changes to be made:
- Thick film ---> thin film.
- Reroute HPF-ed back-plane Vmon output to the front panel LEMO.
I've now restored all the wiring at 1X6 to their state before this work. |
Attachment 1: MC1_coilDriver.pdf
|
|
Attachment 2: MC2_coilDriver.pdf
|
|
Attachment 3: MC3_coilDriver.pdf
|
|
Attachment 4: MC_coilDriverNoises.tgz
|
Attachment 5: ActuationChainNoiseMeas.pdf
|
|
13871
|
Mon May 21 10:15:35 2018 |
gautam | Update | PEM | test setup with seismometer |
I guess it's fine for now while we are still finalizing the setup at EX, but we should eventually line up the seismometer axes with the IFO axes. Is there a photo of the orientation of the seismometer pre heater can tests? If not, probably good to make some sort of markings on the granite slab / seismometer to allow easy lining up of these axes... |
13873
|
Mon May 21 15:34:19 2018 |
gautam | Configuration | Electronics | Channel hijacking history |
Since we've been hijacking channels like there is no tomorrow for the AUX-PLL setup, I'm documenting the channel names here. The next time c1psl requires a reboot, I'll rename these channels to something more sensible. To find the channel mapping, Koji suggested I use this. Has worked well for us so far... We've labelled all pairs of wires pulled out of the cross connects and insulation taped the stripped ends, in case we ever need to go back to the original config.
Previously unused C1PSL Channels now used for AUX PLL
Channel name |
AI/AO |
Function |
C1:PSL-126MOPA_126CURADJ |
AO |
Slow temperature control |
C1:PSL-FSS_RFADJ |
AO |
Servo trigger TTL |
C1:PSL-126MOPA_126PWR |
AI |
PLL error signal monitor |
C1:PSL-126MOPA_DMON |
AI |
PLL control signal monitor |
C1:PSL-FSS_PHCON |
AO |
To mitigate integrator railing
|
|
13878
|
Tue May 22 17:26:25 2018 |
gautam | Update | IOO | MC1 Coil Driver pulled out |
I have pulled out MC1 coil driver board from its Eurocrate, so IMC is unavailable until further notice. Plans:
- Thick film --> Thin Film
- AD797 --> Op27
- Remove Pots in analog actuation path.
- Measure noise
- Route HPF signal (UL DAQ Mon) to front panel. I think we should use the SMA connectors. That way, we have DC and AC voltage monitors available for debugging.
If there are no objections, I will execute Step #5 in the next couple of hours. I'm going to start with Steps 1-4. |
13880
|
Tue May 22 23:28:01 2018 |
gautam | Update | IOO | MC1 Coil Driver pulled out |
This work is now complete. MC1 coil driver board has been reinstalled, local damping of MC1 restored, and IMC has been locked. Detailed report + photos to follow, but measurement of the noise (for one channel) on the electronics workbench shows a broadband noise level of 5nV/rtHz ( ) around 100Hz, which is lower than what was measured here and consistent with what we expect from LISO modeling (with fast input terminated with 50ohm, slow input grounded).
Quote: |
I have pulled out MC1 coil driver board from its Eurocrate, so IMC is unavailable until further notice.
|
|
13883
|
Wed May 23 17:58:48 2018 |
gautam | Update | IOO | MC1 Coil Driver pulled out |
- Marked up schematic + photo post changes uploaded to DCC page.
- There was a capacitor in the DAQ monitor path making a 8kHz corner that I now removed (since the main point of this front panel HPF monitor point is to facilitate easy coil driver noise debugging, and I wanted to be able to use the SR785 out to high frequencies without accounting for an additional low pass). Transfer function from front panel LEMO input to front panel LEMO monitor is shown in Attachment #1.
- Voltage noise measured at DB25 output (with the help of a breakout cable and SR560 G=100) with front panel LEMO input terminated to 50ohm, Bias input grounded, and pin1 of U21A grounded (i.e. watchdog enabled state) is shown in Attachment #2. This measurement was taken on the electronics bench.
- Inside the lab (i.e. coil driver board plugged into eurocrate), the noise measured in the same way looks identical to what was measured in elog13870.
- I tried repeating the measurement by powering the board using an bench power supply and grounding the bias input voltage near 1X6, and the strange noise profile persists. So this supports the hypothesis that some kind of environmental pickup is causing this noise profile. Needs more investigation.
In any case, if it is indeed true that the optic sees this current noise, the place to make the measurement is probably the Sat. Box. Who knows what the pickup is over the ~15m of cable from 1X6 to the optic.
Quote: |
Detailed report + photos to follow
|
|
Attachment 1: MC1_monitorTF.png
|
|
Attachment 2: MC1_ULnoise.pdf
|
|
13885
|
Thu May 24 10:16:29 2018 |
gautam | Update | General | All models on c1lsc frontend crashed |
All models on the c1lsc front end were dead. Looking at slow trend data, looks like this happened ~6hours ago. I rebooted c1lsc and now all models are back up and running to their "nominal state". |
Attachment 1: c1lsc_crashed.png
|
|
13886
|
Thu May 24 13:06:17 2018 |
gautam | Configuration | ALS | DFD noises |
Summary:
- The DFD noise floor is ~0.5Hz/rtHz at 100Hz (see Attachment #2).
- I cannot account for the measured noise floor of the DFD system. The Marconi noise and the AA noise contributions should be neglibible at 100Hz.
- This SURF report would lead me to believe that the delay line cable length is 50m. But my calibration suggests it is shorter, more like 40m (see Attachment #1). I had made some TF measurements of the delay sometime ago, need to dig up the data and see what number that measurement yields.
Details and discussion: (diagrams to follow)
- Delay line linearity was checked by driving the input with Marconi, waiting for any transient to die down, and averaging the I and Q inputs to the phase tracker servo (after correcting for the daughter board TF) for 10 seconds. The deg/MHz response was then calculated by trigonometry. Not sure what to make of the structure in the residuals, need to think about it.
- DFD noise was checked by driving the DFD input with a Marconi at 50MHz, RF level = 8dBm, which are expected parameters for nominal ALS operation. In this configuration, I measured the spectrum of the phase tracker output. I then used the calibration factor from the above bullet to convert to Hz/rtHz.
- The electronics noise contribution of the daughter board was calibrated to Hz/rtHz by using the Marconi to drive the DFD input with a known FM signal (mod depth ~0.05), and using the SR785 to measure the power of the FM peak. This allows one to back out the V/Hz calibration constant of the delay line. I tweaked the carrier frequency until the ratio of power in I channel to Q channel (or the other way around) was >20dB before making this measurement.
- I have no proof - but I suspect that the whole host of harmonics in the noise spectrum is because the 1U AA chassis sits directly on top of some Sorensen power supplies. These Sorensens power the frequency distribution box in the LSC rack, so the simplest test to confirm would be to turn off the RF chain, and then Sorensens, and see if the peaky features persist.
|
Attachment 1: DFDcalib.pdf
|
|
Attachment 2: DFD_NB.pdf
|
|
13889
|
Thu May 24 19:41:28 2018 |
gautam | Configuration | ALS | BeathMouth reinstalled on PSL table |
Summary:
- DC light power incident on beat PD is ~400uW from the PSL and ~300uW from EX.
- These numbers are consistent with measured mating sleeve and fiber coupler losses.
- However, I measure an RF beatnote of 80mVpp (= -18dBm). This corresponds to a mode matching efficiency of ~15%, assuming InGaAs efficiency of 0.65A/W.
I find this hard to believe.
Details:
- I took this opportunity to clean the fiber tips on the PSL table going into the BeatMouth.
- PSL light power going into the BeatMouth is 2.6mW. Of which ~400uW reaches the Beat PD (measured using my new front panel monitor port).
- Similarly, 1mW of EX light reaches the PSL table, of which ~300uW reaches the Beat PD.
- The RF amplifier gain is 20dB, and RF transimpedance is 50 ohms.
- Using the (electrical) 20dB coupled port on the front panel, I measured a beat signal with 8mVpp. So the actual beat note signal is 80mVpp.
Discussion:
As I see it, the possibilities are:
- My measurement technique/calculation is wrong.
- The beat PD
is broken has optoelectronic different that is significantly different from specifications.
- The non-PM fiber lengths inside the beat box result in ~15% overlap between the PSL and EX beams. Morever, there is insignificant variation in the electrical beat amplitude as monitored on the control room analyzer. So there is negligible change in the polarization state inside the BeatMouth.
I guess #3 can be tested by varying the polarization content of one of the input beams through 90 degrees. |
13890
|
Thu May 24 20:31:03 2018 |
gautam | Configuration | ALS | DFD noises |
A couple of months ago, I took 21 measurements of the delay line transfer function. As shown in Attachment #2, the unwrapped phase is more consistent with a cable length closer to 45m rather than 50m (assuming speed of light is 0.75c in the cable, as the datasheet says it is).
Attachment #1 shows the TF magnitude for the same measurements. There are some ripples consistent with reflections, so something in this system is not impedance matched. I believe I used the same power splitter to split the RF source between delayed and undelayed paths to make these TFs as is used in the current DFD setup to split the RF beatnote.
Quote: |
I had made some TF measurements of the delay sometime ago, need to dig up the data and see what number that measurement yields.
|
|
Attachment 1: TF_X_mag.pdf
|
|
Attachment 2: TF_X_phase.pdf
|
|
13896
|
Wed May 30 10:17:46 2018 |
gautam | Update | IOO | MC1 Coil Driver pulled out |
[rana,gautam]
Summary:
Last night, Rana fact-checked my story about the coil driver noise measurement. Conclusions:
- There is definitely pickup of strong lines (see Attachment #1. These are hypothesized to come from switching power supplies). Moreover, they breathe. Checkout Rana's twitter page for the video.
- The lines are almost (but not quite) at integer multiples of 19.5 kHz. The cause of this anharmonicity is to be puzzled out.
- When the coil driver board is located ~1m away from the SR785 and the bench supply powering it, even though the lines are visible in the spectrum, the low frequency shape does not show the weird broad features I reported here. The measured noise floor level is ~5nV/rtHz, which is consistent with LISO noise + SR560 input noise (see Attachment #2). However, there is still some excess noise at 100 Hz above what the LISO model leads us to expect.
- The location of the coil driver board and SR560 relative to the SR785 and the bench power supply I used to power the coil driver board can increase the line heights by ~x50.
- The above changes the shape of the low frequency part of the spectrum as well, and it looks more like what is reported in elog13870. The hypothesis is that the high frequency lines are downconverted in the SR560.
Note: All measurements were made with the fast input of the coil driver board terminated with 50ohms and bias input shorted to ground with a crocodile clip cable.
Next steps:
The first goal is to figure out where this pickup is happening, and if it is actually going to the optic. To this end, I will put a passive 100 kHz filter between the coil driver output and the preamp (Busby Box instead of SR560). By getting a clean measurement of the noise floor with the coil driver board in the Eurocrate (with the bias input driven), we can confirm that the optic isn't being buffeted by the excess coil driver noise. If we confirm that the excess noise is not a measurement artefact, we need to think about were the pickup is actually happening and come up with mitigation strategies.
RXA: good section EMI/RFI in Op Amp Applications handbook (2006) by Walt Jung. Also this page: http://www.electronicdesign.com/analog/what-was-noise |
Attachment 1: EM_pickup.pdf
|
|
Attachment 2: coilDriverNoiseComparison.pdf
|
|
13899
|
Wed May 30 23:57:08 2018 |
gautam | Update | PEM | Burning smell in office area / control room |
[koji, gautam]
We noticed quite a strong burning smell in the office area and control room ~20mins ago. We did a round of the bake lab, 40m VEA and the perimeter of the CES building, and saw nothing burning. But the smell persists inside the office area/control room (although it may be getting less noticeable). There is a whining noise coming from the fan belt on top of the office area. Anyways, since nothing seems to be burning down, we are not investigating further.
Steve [ 10am 5-31 ] we should always check partical count in IFO room
Service requested
|
13901
|
Thu May 31 10:19:42 2018 |
gautam | Update | SUS | MC3 glitchy |
Seems like as a result of my recent poking around at 1X6, MC3 is more glitchy than usual (I've noticed that the IMC lock duty cycle seems degraded since Tuesday). I'll try the usual cable squishing voodo.
gautam 8.15pm: Glitches persisted despite my usual cable squishing. I've left PSL shutter closed and MC watchdog shutdown to see if the glitches persist. I'll restore the MC a little later in the eve. |
Attachment 1: MC3_glitchy.png
|
|
13902
|
Thu May 31 15:36:59 2018 |
gautam | Update | General | New camera channels |
Jon informed me that there are some EPICS channels that JoeB's camera server code looks for that don't exist. I thought Jigyasa and I had added everything last year but turned out not to be the case. I followed my instructions from here, did the trick. While cleaning up, I also re-named the "*MC1" channels to "*ETMX", since that's where the camera now resides. New channels are:
C1: CAM-ETMX_ARCHIVE_INTERVAL (Archival interval in minutes)
C1: CAM-ETMX_ARCHIVE_RESET (Reset Archival interval in minutes)
C1: CAM-ETMX_CONFIG_FILE (Config file)
|
13907
|
Thu May 31 23:12:17 2018 |
gautam | Update | LSC | DRMI locking attempt |
Summary:
I wanted to recover the DRMI locking. Among other things, Jon mentioned that his mode spectroscopy can be done in the DRMI config. But I was foiled last night by a rogue waveplate in the AS beampath, and today evening, I noticed the resurfacing of this problem. Clearly, this is indicative of some issue in the analog whitening electronics, as the DC light level on the AS55 PD is consistent with previous measurements. Moreover, last time, the problem "fixed itself" so I don't know what exactly the problem was in the first place. I'll try doing the same test in the linked elog tomorrow. As a quick test, I cycled through the whitening gains (0-45dB) to see if it was some stuck ADC register, but that didn't fix the problem.
The problem seems to be with REFL55 only - I am able to lock the PRMI with carrier resonant without any issues, and the error signal levels are consistent with what I remember them being while the PRMI is swinging around. AS55 lives on the same whitening board and doesn't seem to suffer from the same probelms.
Decided to do the check tonight, but as Attachment #1 shows, no real red flags from the whitening gain side. |
Attachment 1: REFL55_whtCheck.pdf
|
|
13908
|
Fri Jun 1 01:22:50 2018 |
gautam | Update | LSC | DRMI locking restored |
As it happened last time, the problem apparently fixed itself - somehow the act of me disconnecting the cables and reconnecting them seems to solve the problem, need to think about this.
Anyway, DRMI was locked a few times tonight . I got in a good long stretch where I ran some sensing lines and collected some data, analysis tomorrow. I am going to center the vertex oplevs as an alignment reference for now. A major source of lockloss seems to be angular instability - see for example this video grab of POP:
Could be due to noise injection from the noisy PRM Oplev HeNe, or just TT mirror angular motion (I couldn't get the PRC angular FF going tonight). |
Attachment 1: DRMI_20180531.png
|
|
13913
|
Mon Jun 4 11:00:37 2018 |
gautam | Update | PSL | aux laser replacement |
Quote: |
I couldn't locate an appropriate heat sink for the driver, which is still in factory condiction, but since the PSL AOM also runs on 80MHz I used that one instead.
|
We have the appropriate heatsink - I'd like to minimize interference with the main beam wherever possible.
Quote: |
For the PSL beat the AOM drive is not needed, and the power in the optical fiber should not exceed 100 mW, so the offset voltage to the AOM RF driver has to remain below 300 mV.
|
If damage to the fiber is a concern, I think it's better to use a PBS + waveplate to attenuate the power going into the fiber. When the AOM switching is hooked up to CDS, it's easy to imagine a wrong button being pressed or a wrong value being typed in.
It would probably also be good to have a pickoff monitor for the NPRO DC power so that we can confirm its health (in the short run, we can hijack a PSL Acromag channel for this purpose, as we now do for FSS_RMTEMP). I don't know that we need an EOM for the PLL, as in order to get that going, we probably need some fast electronics for the EOM path, like an FSS box.
STEVE: I ordered the right heatsink for the acousto after Koji pointed out that the vertical fins are 20% more efficient. Why? Because hot air rises. It will be here in 3-4 days. |
13916
|
Tue Jun 5 02:06:59 2018 |
gautam | Update | PSL | aux laser first (NULL) results |
[johannes, gautam]
- Johannes aligned the single bounce off the ITM into the AUX fiber on the AS table, and also the AUX beam into the fiber on the PSL table.
- Mode matching isn't spectaular anywhere in this chain.
- But we have 2.6mW of light going into the SRM with the AOM deflection into the 1st order beam (which is what we send into the IFO) maximum.
- We set up some remote capabilities for the PLL and Marconi frequency (=PLL setpoint) control.
- Motivation was to try and lock DRMI, and look for some resonance of the AUX beam in the SRC.
- We soon realized this was a way too lofty goal.
- So we decided to try the simpler system of PRMI locked on carrier.
- We were successfully able to sweep the Marconi setpoint in up to 20kHz steps (although we can only move the setpoint in one direction, not sure I know why now).
- Then we decided to look for resonances of the AUX beam in the arm cavity.
- Still no cigar


- Plus points:
- PLL can be reliably locked remotely.
- Marconi freq. can be swept deterministically remotely.
- Tomorrow:
- Fix polarization issues. There is some low freq drift (~5min period) of the power incident on the fiber on the PSL table which we don't understand.
- Verify MM into IFO and also into fiber at PSL table.
- Do mode spectroscopy.
I was wondering why the PMC modulation sidebands are showing up on the control room analyzer with ~6dB difference in amplitude. Then I realized that it is reasonable for the cabling to have 6dB higher loss at 80 MHz compared to 20 MHz. |
13919
|
Wed Jun 6 10:44:52 2018 |
gautam | Update | VAC | Annulus pressure channels added to frames |
[steve, gautam]
We added the following channels to C0EDCU.ini and restarted the daqd processes. Channels seem to have been added successfully, we will check trend writing later today. Motivation is to have a long term record of annulus pressure (even though we are not currently pumping on the annulus).
C1:Vac-PASE_status
C1:Vac-PASV_status
C1:Vac-PABS_status
C1:Vac-PAEV_status
C1:Vac-PAEE_status
plot next day |
Attachment 1: AnsPressureLogged.png
|
|
13920
|
Wed Jun 6 14:36:15 2018 |
gautam | Update | LSC | TRX clipping |
For some time now, I've been puzzled by the unreliability of the ASS_X dither alignment servo. Leaving the servo on, TRX often begins to decay to a lower value, and even after freezing the dither at the maximum TRX values, I can manually align the mirrors to increase TRX. We have suspected some kind of clipping in the TRX path that is responsible for this behaviour. Today I decided to investigate this a bit further. To have the arm locked and to inspect the beam, we have to change the locking trigger - TRX is what is normally used, but I misaligned the Y arm completely, and used AS110 as a trigger instead. There is some strangeness in the triggering topology, but this deserves a separate elog.
Once the arm was locked (and relocks using the AS110 trigger in the event of an unlock), I was able to trace the beampath on the EX table with an IR card. The TRX beam is rather large and weak, so it is hard to see, but as best as I can tell, the only real danger of clipping (or perhaps the beam is already clipped) is on the final steering mirror before the beam hits the (Thorlabs) PD. Steve/Pooja are working on getting a photo of this, and will upload it here shortly. Options to mitigate this:
- Use the harmonic separator to steer the beam lower, and center it on the 1" steering mirror. However, this could possibly lead to clipping on some of the upstream lenses.
- Raise the height of the 1" steering mirror by 0.25". However, this would require a custom 3/4" dia post height or some shims, which I am not sure is in line with our optomechanic mounting practises.
- Use a 2" mirror instead of a 1" mirror.
The EX QPD has stopped working since the Acromag install. If it were working, we wouldn't have to rely on the alternate triggering with AS110 and instead just use the QPD as TRX, while we debug the Thorlabs PD path. |
13921
|
Wed Jun 6 14:50:25 2018 |
gautam | Update | General | LSC triggering |
I though that the "C1LSC_TRIG_MTRX" MEDM screen completely controls the triggring of LSC signals. But today while trying to trigger the X-arm locking servo on AS110 instead of TRX, I found some strange behaviour. Summary of important points:
- Even though the servo was supposed to be triggered on AS110, the act of me blocking the beam on the EX table destroyed the lock. I verified the correlation between me blocking the beam and the lock being destroyed by repeating the blocking at least 10 times at different locations along the beam path (to make sure I wasn't accidentally clipping the Oplev beam for example).
- Investigating further, I found that me turning off the TRX signal digitally also deterministically led to the X arm lock being lost. To be clear, the TRX DC element in the trigger matrix was 0.
- Confirmed that TRX wasn't involved in any way in the locking servo (I was checking for normalization of the PDH error signal by the DC transmission value, but this is not done). To do this, I locked the arm, and then turned all elements corresponding to TRX in the PowNorm matrix to 0. Then I disabled the locking servo and re-enabled it, and the lock was readily re-acquired readily.
All very strange, not sure what's going on here. The simulink model diagram also didn't give me any clues. Need's further investigation. |
Attachment 1: LSC_TRIG.png
|
|
13925
|
Thu Jun 7 12:20:53 2018 |
gautam | Update | CDS | slow machine bootfest |
FSS slow wasn't running so PSL PZT voltage was swinging around a lot. Reason was that was c1psl unresponsive. I keyed the crate, now it's okay. Now ITMX is stuck - Johannes just told be about an un-elogged c1susaux reboot. Seems that ITMX got stuck at ~4:30pm yesterday PT. After some shaking, the optic was loosened. Please follow the procedure in future and if you do a reboot, please elog it and verify that the optic didn't get stuck. |
Attachment 1: ITMX_stuck.png
|
|
13927
|
Thu Jun 7 16:15:03 2018 |
gautam | Update | LSC | TRX clipping |
I opted for the quickest fix - I raised the height of the offending steering mirror using a 0.25" shim. In the long term, we can get a taller post machined. After raising the mirror height, I then checked the DC centering of the spot on the DC PD using a scope.
Looking at the performance of the X arm ASS, I no longer see the strange oscillatory behaviour I described in my previous post . Moreover, the TRX level was ~1 before be raising the steering mirror - but it is now ~1.2. So we were certainly losing some power. |
13931
|
Fri Jun 8 00:36:54 2018 |
gautam | Update | PSL | observing the resonance signal corresponding to the injected frequency. |
It isn't clear to me in the drawing where the Agilent is during this measurement. Over 40m of cabling, the loss of signal can be a few dB, and considering we don't have a whole lot of signal in the first place, it may be better to send the stronger RF signal (i.e. Marconi pickoff) over the long cable rather than the weak beat signal from the Transmission photodiode. |
13933
|
Fri Jun 8 01:58:56 2018 |
gautam | Update | LSC | DRMI locking attempt again |
Given the various changes to the IFO config since last Thursday when I was last able to lock the DRMI, I wanted to try once again tonight. However, I had no success. By my judgement, the alignment is fine as judged by looking at mode flashes on the cameras. However, despite following the usual alignment procedures, I did not get a single lock in tonight. 
Perhaps we can use a flip mount on the BS that combines the PSL and AUX beams on the AS table, so we have the option of recovering the usual IFO config when we so desire - while Jon needs the SRC locked for his measurement, it would be nice to not have to figure out the correct demod phases etc each time there is a change in the optical setup of the AUX beam. |
13935
|
Fri Jun 8 20:15:08 2018 |
gautam | Update | CDS | Reboot script |
Unfortunately, this has happened (and seems like it will happen) enough times that I set up a script for rebooting the machine in a controlled way, hopefully it will negate the need to repeatedly go into the VEA and hard-reboot the machines. Script lives at /opt/rtcds/caltech/c1/scripts/cds/rebootC1LSC.sh. SVN committed. It worked well for me today. All applicable CDS indicator lights are now green again. Be aware that c1oaf will probably need to be restarted manually in order to make the DC light green. Also, this script won't help you if you try to unload a model on c1lsc and the FE crashes. It relies on c1lsc being ssh-able. The basic logic is:
- Ask for confirmation.
- Shutdown all vertex optic watchdogs, PSL shutter.
- ssh into c1sus and c1ioo, shutdown all models on these machines, soft reboot them.
- ssh into c1lsc, soft reboot the machine. No attempt is made to unload the models.
- Wait 2 minutes for all machines to come back online.
- Restart models on all 3 vertex FEs (IOPs first, then rest).
- Prompt user for confirmation to re-enable watchdog status and open PSL shutter.
|
Attachment 1: 31.png
|
|
13942
|
Mon Jun 11 18:49:06 2018 |
gautam | Update | CDS | c1lsc dead again |
Why is this happening so frequently now? Last few lines of error log:
[ 575.099793] c1oaf: DAQ EPICS: Int = 199 Flt = 706 Filters = 9878 Total = 10783 Fast = 113
[ 575.099793] c1oaf: DAQ EPICS: Number of Filter Module Xfers = 11 last = 98
[ 575.099793] c1oaf: crc length epics = 43132
[ 575.099793] c1oaf: xfer sizes = 128 788 100988 100988
[240629.686307] c1daf: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1cal: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1ass: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1oaf: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1lsc: ADC TIMEOUT 0 43039 31 43103
[240630.684493] c1x04: timeout 0 1000000
[240631.684938] c1x04: timeout 1 1000000
[240631.684938] c1x04: exiting from fe_code()
I fixed it by running the reboot script. |
Attachment 1: 36.png
|
|
13947
|
Mon Jun 11 23:22:53 2018 |
gautam | Update | CDS | EX wiring confusion |
[Koji, gautam]
Per this elog, we don't need any AIOut channels or Oplev channels. However, the latest wiring diagram I can find for the EX Acromag situation suggests that these channels are hooked up (physically). If this is true, there are 12 ADC channels that are occupied which we can use for other purposes. Question for Johannes: Is this true? If so, Kira has plenty of channels available for her Temperature control stuff..
As an aside, we found that the EPICS channel names for the TRX/TRY QPD gain stages are somewhat strangely named. Looking closely at the schematic (which has now been added to the 40m DCC tree, we can add out custom mods later), they do (somewhat) add up, but I think we should definitely rename them in a more systematic manner, and use an MEDM screen to indicate stuff like x4 or x20 or "Active" etc. BTW, the EX and EY QPDs have different settings. But at least the settings are changed synchronously for all four quadrants, unlike the WFS heads...
Unrelated: I had to key the c1iscaux and c1auxey crates. |
13948
|
Tue Jun 12 03:22:25 2018 |
gautam | Update | LSC | AUX laser shuttered |
I worked a bit on recovering the DRMI locking again tonight. I decided to shutter the AUX laser on the PSL table at least until I figured out the correct locking settings. As has become customary now, there was a cable in the AS beampath (leading from the AS55 DC monitor to nothing, through the enclosure side panel, it is visible in Attachment #3 in this elog) which I only found after 30mins of futility - please try and remove all un-necessary cables and leave the AS beampath in a usable state after working on the AS table! In the end, I got several short (~3mins) stretches in tonight, but never long enough to do the loop characterization I wanted to get in tonight, probably wrong gains in one or more of the loops. In the last 30 minutes, the IMC has been frequently losing lock, so I am quitting for now. The AUX laser remains shuttered. |
13949
|
Tue Jun 12 14:47:37 2018 |
gautam | Bureaucracy | General | Unlabelled components from EX moved to SP table and labelled |
Steve mentioned two unlabelled optics were found at EX, relics from the Endtable upgrade.
- One was a 1" 45 deg p-pol optic (Y1-1025-C-45P), it looks a bit scratched.
- The other was a Beam Sampler (BSF10-C).
These are now labelled and forked down on the SP table. |
13952
|
Wed Jun 13 01:02:40 2018 |
gautam | Update | LSC | Reliable and repeatable 1f DRMI locking |
[koji, gautam]
With Koji's help, I got repeatable and reliable DRMI locking going again tonight - this is with the AS path optics for the spectroscopy measurement in place, although the AUX laser remained shuttered tonight. Results + spectra tomorrow, but here's what I did:
- Initial alignment procedure was as usual - use arms+ASS to align ITMs, and then PRMI carrier+ASS to align PRM and BS.
- Found the appropriate gains and demod phases.
- Measured loop TFs - PRCL is a big mystery. Used these to finalize loop gains.
- Ran some sensing lines.
- Whitened DRMI PDs for a calibrated "low-noise" spectrum (although the coils were not de-whitened).
As I have found before, it is significantly easier to get the locking going post 11pm - the wall Seis BLRMS don't look that much quieter at midnight compared to 10pm, but this might be a scaling issue. I'll do a quantitative assessment next time... Also, Foton takes between 25-45 secs to save an updated filter (timed twice today). |
13953
|
Wed Jun 13 11:17:40 2018 |
gautam | Update | LSC | PRCL loop shape anomaly |
Attachment #1 shows the measured PRCL loop shape. The blue line is meant to be the "expected" loop shape. While the measured loop shape tracks the expectation down to ~100 Hz, I cannot explain the shape below it. I am also not sure what to make of the fact that there is high coherence down to 10 Hz fron IN2 to IN1, but no coherence between EXC/IN2. I confirmed that the low-frequency boost filters were ON during the measurement. I don't understand how a pendulum TF + the digital filters we used can account for the shape below 100Hz.
gautam 11pm: After discussing with Koji, I conclude that the low frequency loop shape is consistent with the excitation amplitude being insufficient below 100 Hz. Coherence is good between In1/In2 because they are the same signal effectively - what we need is coherence between In1 and EXC, which isn't plotted. It is still strange that Coherence between In2/EXC is ZERO....
Quote: |
Measured loop TFs - PRCL is a big mystery. Used these to finalize loop gains.
|
|
Attachment 1: PRCL_12Jun2018_WeirdShape.pdf
|
|
13955
|
Wed Jun 13 12:21:09 2018 |
gautam | Update | ALS | PDFR laser checkout |
I want to use the Fiber Coupled laser from the PDFR system to characterize the response of the fiber coupled PDs we use in the BeatMouth. The documentation is pretty good: for a first test, I did the following in this order:
- Removed the input fiber to the 1x16 splitter located in the rack near the OMC chamber.
- Connected aforementioned fiber to a collimator.
- Aligned the output of the collimator onto a razor beam dump.
- Turned on the laser controller - it came on with a TEC temperature of 22.5 C and I_diode 0 mA, and the "output shorted" LED was ON (red).
- Turned up the diode current to 80 mA, since the "threshold current" is stated as 75 mA in the manual. In fact, I could see a beam using an IR card at 30 mA already.
- At 80mA, I measured 3.5 mW of output power using the Ophir.
Seems like stuff is working as expected. I don't know what the correct setpoint for the TEC is, but once that is figured out, the 1x16 splitter should give me 250 uW from each output for 4mW input. This is well below any damage threshold of the Menlo PDs. Then the plan is to modulate the intensity of the diode laser using the Agilent, and measure the optoelectronic response of the PD in the usual way. I don't know if we have a Fiber coupled Reference Photodiode we can use in the way we use the NF1611 in the Jenne laser setup. If not, the main systematic measurement error will come from the power measurement using a Fiber Power Meter. |
13957
|
Wed Jun 13 22:07:31 2018 |
gautam | Update | ALS | BeatMouth PDFR measurement |
Summary:
Neither of the Menlo FPD310 fiber coupled PDs in the beat mouth have an optoelectronic response (V/W) as advertised. This possibly indicates a damaged RF amplification stage inside the PD.
Motivation:
I have never been able to make the numbers work out for the amount of DC light I put on these PDs, and how much RF beat power I get out. Today, I decided to measure the PD response directly.
Details:
In the end, I decided that slightly modifying the Jenner laser setup was the way to go, instead of futzing around with the PDFR laser. These PDs have a switchable gain setting - for this measurement, both were set to the lower gain such that the expected optoelectronic response is 409 V/W.
[Attachment #1] - Sketch of the experimental setup.
[Attachment #2] - Measured TF responses, the RF modulation was -20dBm for all curves. I varied the diode laser DC current a little to ensure I recovered identical transfer functions. Assumptions used in making these plots:
- NF1611 and FPD310 have equal amounts of power incident on them.
- The NF1611 transimpedance is 700V/A.
[Attachment #3] - Tarball of data + script used to make Attachment #2.
Conclusions:
- The FPD310 does not have a DC monitor port.
- So the dominant uncertainty in these plots is that I don't know how much power was incident on the PD under test.
- The NF1611 DC power level could be measured though, and seemed to scale with DC pump current linearly (I had only 3 datapoints though so this doesn't mean much).
- Neither PD has transimpedance gain as per the specs.
- The X PD shows levels ~x10 lower than expected.
- The Y PD shows levels ~x3 lower than expected.
- I will repeat the measurement tomorrow by eliminating some un-necessary patch fiber cables, and also calibrating out the cable delays.
- The setup shown in Attachment #1 was used because I didn't want to open up the BeatMouth.
- But I can pipe the port of the BS not going to the FPD310 directly to the collimator, and that should reduce the systematic uncertainty w.r.t. power distribution between FPD310 and NF1611.
|
Attachment 1: IMG_7056.JPG
|
|
Attachment 2: BeatMouthPDFR.pdf
|
|
Attachment 3: BeatMouth_PDFRdata.tgz
|
13959
|
Thu Jun 14 00:40:42 2018 |
gautam | Update | LSC | PRCL loop shape anomaly |
don't use IN_1/IN_2: recall pizza meeting from a few weeks back: use IN1/EXC + Al-Gebra
Quote: |
Quote: |
Measured loop TFs - PRCL is a big mystery. Used these to finalize loop gains.
|
|
|
13961
|
Thu Jun 14 10:41:00 2018 |
gautam | Update | CDS | EX wiring confusion |
Do we really have 2 free ADC channels at EX now? I was under the impression we had ZERO free, which is why we wanted to put a new ADC unit in. I think in the wiring diagram, the Vacuum gauge monitor channel, Seis Can Temp Sensor monitor, and Seis Can Heater channels are missing. It would also be good to have, in the wiring diagram, a mapping of which signals go to which I/O ports (Dsub, front panel BNC etc) on the 4U(?) box housing all the Acromags, this would be helpful in future debugging sessions.
Quote: |
TYPE |
Total |
Available now |
Available after |
ADC |
24 |
2 |
14 |
|
|
13962
|
Thu Jun 14 13:29:51 2018 |
gautam | Update | General | PSL shutter closed, all optics misaligned |
[jon, gautam]
Jon is doing some characterization of the AUX laser setup for which he wanted only the prompt retroreflection from the SRM on the AS table, so the PSL shutter is closed, and both ITMs and ETMs are misaligned. The prompt reflection from the SRM was getting clipped on something in vacuum - the ingoing beam looked pretty clean, but the reflection was totally clipped, as I think Johannes aligned the input beam with the SRM misaligned. So the input steering of the AUX laser beam into the vacuum, and also the steering onto AS110, were touched... Also, there were all manner of stray, undumped beams from the fiber on the AS table Jon will post photos.
Before we began this work, we found that c1susaux was dead so we rebooted it. |
13963
|
Thu Jun 14 15:21:58 2018 |
gautam | Update | Computer Scripts / Programs | /cvs/cds Backup in danger |
I think this is because /cvs/cds is getting too big. lsblk reveals:
controls@chiara|~> lsblk
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sda 8:0 0 465.8G 0 disk
├─sda1 8:1 0 446.9G 0 part /
├─sda2 8:2 0 1K 0 part
└─sda5 8:5 0 18.9G 0 part [SWAP]
sdb 8:16 0 2.7T 0 disk
└─sdb1 8:17 0 2T 0 part /home/cds
sr0 11:0 1 1024M 0 rom
sdc 8:32 0 1.8T 0 disk
└─sdc1 8:33 0 1.8T 0 part /media/40mBackup
sdd 8:48 0 1.8T 0 disk
└─sdd1 8:49 0 1.8T 0 part
I believe one of sdc or sdd is connected via SATA while the other is an external USB drive. Maybe we have to get bigger backup disks, but this may be a huge pain to setup as it will involve taking chiara down. Actually, now that I check the backup log, seems like backup is executing successfully - not sure if this is due to my unelogged mounting of sdc (using sudo mount /dev/sdc1 /media/40mBackup) last week, or if this is some LDAS backup. But in any case, seems undesirable that sdb1 is larger than sdc1 or sdd1.
2018-06-06 07:00:01,086 INFO Updating backup image of /cvs/cds
2018-06-06 07:00:01,086 ERROR External drive not mounted!!!
2018-06-07 07:00:01,147 INFO Updating backup image of /cvs/cds
2018-06-07 07:00:01,147 ERROR External drive not mounted!!!
2018-06-08 07:00:01,244 INFO Updating backup image of /cvs/cds
2018-06-08 08:23:32,939 INFO Backup rsync job ran successfully, transferred 316870 files.
2018-06-09 07:00:01,465 INFO Updating backup image of /cvs/cds
2018-06-09 07:12:11,865 INFO Backup rsync job ran successfully, transferred 1926 files.
2018-06-10 07:00:01,842 INFO Updating backup image of /cvs/cds
2018-06-10 07:12:28,931 INFO Backup rsync job ran successfully, transferred 1656 files.
2018-06-11 07:00:01,294 INFO Updating backup image of /cvs/cds
2018-06-11 07:06:14,748 INFO Backup rsync job ran successfully, transferred 1664 files.
2018-06-12 07:00:02,081 INFO Updating backup image of /cvs/cds
2018-06-12 07:07:36,775 INFO Backup rsync job ran successfully, transferred 1870 files.
2018-06-13 07:00:02,194 INFO Updating backup image of /cvs/cds
2018-06-13 07:08:37,356 INFO Backup rsync job ran successfully, transferred 1818 files.
2018-06-14 07:00:01,753 INFO Updating backup image of /cvs/cds
2018-06-14 07:01:43,270 INFO Backup rsync job ran successfully, transferred 1744 files.
Quote: |
Local backup on chiara seems not working since Nov 19, 2017.
/opt/rtcds/caltech/c1/scripts/backup/localbackup.log
2017-11-18 07:00:01,504 INFO Updating backup image of /cvs/cds
2017-11-18 07:03:00,113 INFO Backup rsync job ran successfully, transferred 1954 files.
2017-11-19 07:00:02,564 INFO Updating backup image of /cvs/cds
2017-11-19 07:00:02,592 ERROR External drive not mounted!!!
|
|
13966
|
Thu Jun 14 18:09:24 2018 |
gautam | Update | LSC | Reliable and repeatable 1f DRMI locking |
I finally analyzed the sensing measurement I ran on Tuesday evening. Sensing responses for the DRMI DOFs seems consistent with what I measured in October 2017, although the relative phasing of the DoFs in the sensing PDs has changed significantly. For what it's worth, my Finesse simulation is here. |
Attachment 1: DRMI1f_June14.pdf
|
|
13967
|
Thu Jun 14 19:30:12 2018 |
gautam | Update | General | IFO alignment restored |
All optics have been re-aligned. Jon/Johannes will elog about the work today. |