gautam | Update | CDS | slow machine bootfest |
After ~3months without any problems on the slow machine front, I had to reboot c1psl, c1susaux and c1iscaux today. The control room StripTool traces were not being displayed for all the PSL channels so I ran testSlowMachines.bash to check the status of the slow machines, which indicated that these three slow machines were dead. After rebooting the slow machines, I had to burt-restore the c1psl snapshot as usual to get the PMC to lock. Now, both PMC and IMC are locked. I also had to restart the StripTool traces (using scripts/general/startStrip.sh) to get the unresponsive traces back online.
Steve tells me that we probably have to do a reboot of the vacuum slow machines sometime soon too, as the MEDM screen for the Vacuum indicator channels are unresponsive.
Quote: |
Had to reboot c1psl, c1susaux, c1auxex, c1auxey and c1iscaux today. PMC has been relocked. ITMX didn't get stuck. According to this thread, there have been two instances in the last 10 days in which c1psl and c1susaux have failed. Since we seem to be doing this often lately, I've made a little script that uses the netcat utility to check which slow machines respond to telnet, it is located at /opt/rtcds/caltech/c1/scripts/cds/testSlowMachines.bash.
|
|
13011
|
Wed May 24 18:19:15 2017 |
Kaustubh | Update | General | ET-3010 PD Test |
Summary:
In continuation to the previous test conducted on the ET-3040 PD, I performed a similar test on the ET-3010 model. This model requires a fiber couple input for proper testing, but I tested it in free space without a fiber couple as the laser power was only 1.00 mW and there was not much danger of scattering of the laser beam. The Data Sheet can be found here
Procedure:
The schematic(attached below) and the procedure are the same as the previous time. The pump current was set to 19.5 mA giving us a laser beam of power 1.00mW at the fiber couple output. The measured voltage for the reference detector was 1.8V. For the DUT, the voltage is amplified using a low noise amplifier(model SR-560) with a gain of 100. Without any laser incidence on the DUT, the multimeter reads 120.6 mV. After alligning the laser with the DUT, the multimeter reads 348.5 mV, i.e. the voltage for the DUT is 227.9/100 ~ 2.28 mV. The DC transimpedance of the reference detector is 10kOhm and its responsivity to 1064 nm is around 0.75 A/W. Using this we calculate the power at the reference detector to be 0.24 mW. The DC transimpedance for the DUT is 50Ohm and the responsivity is around 0.85 A/W. Using this we calculate the power at the DUT to be 0.054 mW. After this we connect the the laser input to the Netwrok Analyzer(AG4395A) and give an RF signal with -10dBm and frequency modulation from 100 kHz to 500 MHz.The RF output from the Analyzer is coupled to the Reference Channel(CHR) of the analyzer via a 20dB directional coupler. The AC output of the reference detector is given at Channel A(CHA) and the output from the DUT is given to Channel B(CHB). We got plots of the ratios between the reference detector, DUT and the coupled refernce for the Transfer Function and the Phase. I stored the data under the directory.../scripts/general/netgpibdata/data. The Bode Plot has been attached below and seeing it we observe that the cut-off frequency for the ET-3010 model is atleast over 500 MHz(stated as >1.5 GHz in the data sheet).
Result:
The bandwidth of the ET-3010 PD is atleast 500MHz, stated in the data sheet as >1.5GHz.
Precaution:
The ET-3010 PD has an internal power supply of 6V. Don't leave the PD connected to any instrument after the experimentation is done or else the batteries will get drained if there is any photocurrent on the PDs.
To Do:
Caliberate the vertical axis in the Bode Plot with transimpedance(Ohms) for the two PDs. Automate the procedure by making a Python script for taking multiple set of readings from the Netwrok Analyzer and aslo plot the error bands. |
Attachment 1: PD_test_setup.png
|
|
Attachment 2: ET-3010_test.pdf
|
|
Attachment 3: ET-3010_test.zip
|
13010
|
Tue May 23 22:58:23 2017 |
gautam | Update | General | De-Whitening board noises |
Summary:
I wanted to match a noise model to noise measurement for the coil-driver de-whitening boards. The main objectives were:
- Make sure the various poles/zeros of the Bi-Quad stages and the output stage were as expected from the schematics
- Figure out which components are dominating the noise contribution, so that these can be prioritized while swapping out the existing thick-film resistors on the board for lower noise thin-film ones
- Compare the noise performance of the existing configuration, which uses an LT1128 op-amp (max output current ~20mA) to drive the input of the coil-driver board, with that when we use a TLE2027 (max output current ~50mA) instead. This last change is motivated by the fact that an earlier noise-simulation suggested that the Johnson noise of the 1kohm input resistor on the coil driver board was one of the major noise contributors in the de-whitening board + coil driver board signal chain. Since the TLE2027 can drive an output current of up to 300mA, we could reduce the input impedance of the coil-driver board to mitigate this noise source to some extent.
Measurement:
- The back-plane pin controlling the MAX333A that determines whether de-whitening is engaged or not (P1A) was pulled to ground (by means of one of the new extender boards given to us by Ben Abbott). So two de-whitening stages were engaged for subsequent tests.
- I first measured the transfer function of the signal path with whitening engaged, and then fit my LISO model to the measurement to tweak the values of the various components. This fitted file is what I used for subsequent noise analysis.
- For the noise measurement, I shorted the input of the de-whitening board (10-pin IDE connector) directly to ground.
- I then measured the voltage noise at the front-panel SMA connector with the SR785
- The measurements were only done for 1 channel (CH1, which is the UL coil) for 4 de-whitening boards (2 ITMs, BS, and SRM). The 2 ITM boards are basically identical, and the BS and SRM boards are similar. Here, only results for the board labelled "ITMX" are presented.
- For this board, I also measured the output voltage noise when the LT1128 was replaced with a TLE2027 (SOIC package, soldered onto a SOIC-to-DIP adaptor). Steve has found (ordered?) some DIP variants of this IC, so we can compare its noise performance when we get it.
Results:
- Attachment #1 shows the modeled and measured noises, which are in fairly good agreement.
- The transfer function measurement/fitting (not attached) also suggests that the poles/zeros in the signal path are where we expect as per the schematic. I had already verified the various resistances, but now we can be confident that the capacitance values on the schematic are also correct.
- The LT1128 and TLE2027 show pretty much identical noise performance.
- The SR785 noise floor was low enough to allow this measurement without any pre-amp in between.
- I have identified 3 resistors from the LISO model that dominate the noise (all 3 are in the Bi-Quad stages), which should be the first to be replaced.
- There are some pretty large 60 Hz harmonics visible. I thought I was careful enough avoiding any ground loops in the measurement, and I have gotten some more tips from Koji about how to better set up the measurement. This was a real problem when trying to characterize the Coil Driver noise.
Next steps:
- I have data from the other 3 boards I pulled out, to be updated shortly.
- The last piece (?) in this puzzle is the coil driver noise - this needs to be modeled and measured.
- Once the coil driver board has been characterized, we need to decide what changes to make to these boards. Some things that come to mind at the moment:
- Replace critical resistors (from noise-performance point of view) with low noise thin film ones.
- Remove the "fast analog" path on the coil driver boards - these have potentiometers in series with the coil, which we should remove since we are not using this path anyways.
- Remove all AD797s from both de-whitening and coil driver boards - these are mostly employed as monitor points that go to the backplane connector, which we don't use, and so can be removed.
- Increase the series resistor at the output of the coil driver (currently, these are either 100ohm or 400ohm depending on the optic/channel). I need to double check the limits on the various LSC servos to make sure we can live with the reduced range we will have if we up these resistances to 1 kohm (which serves to reduce the current noise to the coils, which is ultimately what matters).
|
Attachment 1: ITMX_deWhite_ch1_noise.pdf
|
|
13009
|
Tue May 23 18:09:18 2017 |
Kaustubh | Configuration | General | Testing ET-3010 PD |
In continuation with the previous(ET-3040 PD) test.
The ET-3010 PD requires to be fiber coupled for optimal use. I will try to test this model without the fiber couple tomorrow and see whether it works or not. |
13008
|
Tue May 23 16:33:00 2017 |
Steve | Update | Optical Levers | Beam Profiling Results |
You may compare your results with this.
RXA: please no, that's not the right way |
13007
|
Tue May 23 15:22:04 2017 |
rana | Update | Optical Levers | Beam Profiling Results |
- Include several sources of error. Micrometer error is one, but you should be able to think of at least 3 more.
- There should be an error bar for the x and y axis.
- Also, use pdftk to put the PDFs all into a single file. Remove so much whitespace.
- Google 'beautiful plots python' and try to make your plots for the elog be more like publication quality for PRL or Nature.
|
13006
|
Tue May 23 10:27:24 2017 |
Dhruva | Update | Optical Levers | Beam Profiling Results |
I have attempted to calculate the instrument error (micrometer least count) using the values of the spot size obtained by the least squares fitting method. This error is large towards the centre of the beam as the power varies significantly between adjecent markings of the micrometer. Using the new values of error obtained, I used the chi-square fitting minimisation method to further optimise the waist size.
The modified values are -
z(cm) w (in)
4 0.0134
10 0.0135
15 0.0140
20 0.0142
25 0.0150
And the revised values for the beam waist and location are 338.63 microns and -2.65 cm respectively.
I will now try to use the chi-square stastitic to estimate the error in spot size. |
Attachment 1: z_25_chisq.pdf
|
|
Attachment 2: z_20_chisq.pdf
|
|
Attachment 3: z_15_chisq.pdf
|
|
Attachment 4: z_10_chisq.pdf
|
|
Attachment 5: z_4_chisq.pdf
|
|
Attachment 6: spotsize.pdf
|
|
13005
|
Mon May 22 18:20:27 2017 |
Kaustubh | Summary | General | Testing of the new Photo Detectors ET-3010 and ET-3040 |
I am adding the text files with the data readings and paramater settings along with the Bode Plot of the data. I plotted these graphs using matplotlib module with python 2.7.
Quote: |
Motivation:
I got some hands-on-experience on using RF photodetectors and the Network Analyzer from Koji. There were newly purchased RF photodetectors from Electro-Optics Technology, Inc.. These were InGaAs Photodetectors with model no.: 120-10050-0001(ET-3010) and 120-10056-0001(ET-3040). The User Guide for the two detectors can be found here. This is the first time we bought the ET-3010 model PD for the 40m lab. It has an operation bandwith >1.5GHz(not tested yet), much higher than other PDs of its kind. This can be used for detecting the output as we 'sweep' the laser frequency for getting data on the optical cavities and the resonating modes inside the cavity. We just tested out the ET-3040 model today but will test out the ET-3010 next week...
|
|
Attachment 1: ET-3040_test.zip
|
Attachment 2: ET-3040_test.pdf
|
|
13004
|
Mon May 22 15:01:41 2017 |
jigyasa | Update | telescope design | Updated Telescope design with 1'' eye piece |
I examined the use of a single lens system for the available range of focal lengths, for the required magnification and found that a focal length of at most 100 mm would be required to sufficiently cover the object distance range. This would greatly compromise with the f-number and hence lead to a lot more spherical aberrations.
Therefore, a two lens system would be more useful to implement. Using an eyepiece of 1” puts an additional constraint on the system such that the separation between the lenses must now at least equal or be greater than half the image distance from the first lens to ensure that no light from the light cone is lost. This is clarified in the schematic. The image from the first lens in absence of the second lens would form at point A, subtending an angle θ. In order to ensure that no part this light cone emerging from the first lens is lost, the second lens must be placed at a distance atleast v/2 from the first lens.
A combination of 125mm focal length 2” diameter objective with a 250 mm 1” eyepiece covers the required range of object distances (650mm to 1500 mm). Increasing the focal length of the eye piece increases the minimum object distance accessible to 700 mm.
A glance at the accessible u, v points shows that all magnifications are not possible at a given object distance. To image the entire surface of the test mass, a distance of at least 1.25m is required from the objective, while a beam spot of 1'' diameter can be imaged easily at upto 1200 mm from the objective . This holds true even for the 150-250 mm biconvex 2" lens combination proposed earlier.
If this sounds reasonable, we could proceed with ordering the lenses. |
Attachment 1: 1incep.pdf
|
|
13003
|
Mon May 22 13:37:01 2017 |
gautam | Update | General | DAC noise estimate |
Summary:
I've spent the last week investigating various parts of the DAC -> OSEM coil signal chain in order to add these noises to the MICH NB. Here is what I have thus far.
Current situation:
- Coils are operated with no DAC whitening
- So we expect the DAC noise will dominate any contribution from the electronics noise of the analog De-Whitening and Coil Driver boards
- There is a factor of 3 gain in the analog De-Whitening board
DAC noise measurement:
- I essentially followed the prescription in G1401335 and G1401399
- So far, I only measured one DAC channel (ITMX UL)
- The noise shaping filter in the above documents was adapted for this measurement. The noise used was uniform between DC and 1kHz for this test.
- For the >50Hz bandstops, I used 1 complex pole pair at 5Hz, and 1 compelx zero pair at 50Hz to level off the noise.
- For <50Hz bandstops, I used 1 compelx pole pair at 1Hz and 1 complex zero pair at 5Hz to push the RMS to lower frequencies
- I set the amplitude ("gain" = 10,000 in awggui) to roughly match the Vpp when the ITM local damping loops are on - this is ~300mVpp (measured with a scope).
- The elliptic bandstops were 6th order, with 50dB stopband attenuation.
- The SR785 input auto-ranging was disabled to allow a fair comparison of the various bandstops - this was fixed to -20 dBVpk for all measurements, and the SR785 noise floor shown is also for this value of the input range. Input was also AC coupled, and since I was using the front-panel LEMO for this test, the signal was effectively single-ended (but the ground of the SR785 was set to "floating" in order to get the differential signal from the DAC)
- Attachment #1 shows the results of this measurement - I've subtracted the SR785 noise from the other curves. The noise model was motivated by G1401399, but I use an f^-1/2 model rather than an f^-1 model. It seems to fit the measurement alright (though the "fit" is just done by eye and not by systematic optimization of the parameters of the model function).
Noise budget:
- I then tried to translate this result into the noise budget
- The noises for the 4 face coils are added in quadrature, and then the contribution from 3 optics (2 ITMs and BS) are added in quadrature
- To calibrate into metres, I converted the DAC noise spectral density into cts/rtHz, and used the numbers from this elog. I thought I had missed out on the factor of 3 gain in the de-white board, but the cts-to-meters number from the referenced elog already takes into account this factor.
- Just to be clear, the black line for DAC noise in Attachment #2 is computed from the single-channel measurement of Attachment #1 according to the following relation:
, where G_act is the coil transfer function from the referenced elog, taken as 5nm/f^2 on average for the 2 ITMs and BS, the factor of 2 comes from adding the noise from 4 coils in quadrature, and the factor of sqrt(6) comes from adding the noise from 3 optics in quadrature (and since the BS has 4 times the noise of the ITMs)
- Using the 0.016N/A number for each coil gave me an answer than was off by more than an order of magnitude - I am not sure what to make of this. But since the other curves in the NB are made using numbers from the referenced elog, I think the answer I get isn't too crazy...
- Attachment #2 shows the noise budget in its current form, with DAC noise added. Except for the 30-70Hz region, it looks like the measured noise is accounted for.
Comments:
- I have made a number of assumptions:
- All DAC channels have similar noise levels
- Tried to account for asymmetry between BS and ITMs (BS has 100 ohm resistance in series with the coil driver while the ITMs have 400 ohms) but the individual noises haven't been measured yet
- This noise estimate holds for the BS, which is the MICH actuator (I didn't attempt to simulate the in-lock MICH control signal and then measure the DAC noise)
- But this seems sensible as a first estimate
- The dmesg logs for C1SUS don't tell me what DACs we are using, but I believe they are 16-bit DACs (I'll have to restart the machine to make sure)
- In the NB, the flattening out of some curves beyond 1kHz is just an artefact of the fact that I don't have data to interpolate in that region, and isn't physical.
- I had a brief chat with ChrisW who told me that the modified EEPROM/Auto-Cal procedure was only required for 18-bit DACs. So if it is true that our DACs are 16-bit, then he advised that apart from the DAC noise measurement above, the next most important thing to be characterized is the quantization noise (by subtracting the calculated digital control signal from the actual analog signal sent to the coils in lock)
- More details of my coil driver electronics investigations to follow...
|
Attachment 1: DAC_noise_model.pdf
|
|
Attachment 2: C1NB_disp_40m_MICH_NB_22_May_2017.pdf
|
|
13002
|
Mon May 22 10:53:02 2017 |
Dhruva | Update | Optical Levers | Beam Profiling Results |
Quote: |
Andrew and I set up the razor blade beam profiling experiment for He-Ne lasers on the "SP" table. Once I receive the laser safety training, I will make power measurements and fit it to an erfc curve from which I will calculate the gaussian profile of the beam. I'm attaching some pictures of the setup.
Least count of the micrometer - 2 microns
Laser : Lumentum 22037130:1103P
Photodetector : Thor Labs PDA100A
|
I had measured the y-profile of the beam of Friday at 5 axial locations and fit them to an erfc function using the lsqcurvefit function of MATLAB.
The results were as follows -
z(cm) w (in)
4 0.0131
10 0.0132
15 0.0137
20 0.0139
25 0.0147
I left w in inches in the intensity plots as MATLAB gave more accurate fits for those values.
I converted these to S.I while making the spot-size vs z plot and the corresponding values in microns were
332.74, 335.28, 347.98, 353.06, 373.38.
On fitting these values to the formula for the spot size of a Gaussian beam, the beam waist came out to be 330.54 microns and the location of the beam waist was at z=-2cm, where z=0 marks the head of the laser.
TO-DO : Measure the spot size of the beam at more axial points to obtain a better fit.
Measure the x-profile of the beam.
Analyse the error in the spot sizes and corresponding error in the beam waist.
|
Attachment 1: spot_size_.pdf
|
|
Attachment 2: z_25.pdf
|
|
Attachment 3: z_20.pdf
|
|
Attachment 4: z_15.pdf
|
|
Attachment 5: z_10.pdf
|
|
Attachment 6: z_4.pdf
|
|
13000
|
Mon May 22 10:15:14 2017 |
jigyasa | Summary | telescope design | Lens tubes and object distances |
Since the f numbers of the lenses in the proposed design with biconvex lenses are a little less than 5 and the conjugate ratio(that is the ratio of object to image distance) is greater than 5, I explored the use of plano convex lenses, but with the same focal lengths, the accessible u-v range is restricted with the planoconvex rather than biconvex lenses.
On Friday, I had a discussion with Gautam and Steve about the hardware that is the cylindrical enclosures for the camera and the telescope and we examined two such aluminum cylindrical enclosures. One of them was the one being currently employed for the cameras. The dimensions were measured and the length was found to be 8’’ and an outer diameter of 26 cm within an error of 0.5 cm.
The other enclosure was longer with a length of 52 cm(±0.5 cm), outer diameter of 10”(±0.1”) and an inner diameter of 23.7cm(±0.1cm). Pictures of these enclosures are attached.
Both of these enclosures have internal optical rail to mount the camera and the telescope system. Depending on the weight of the telescope system(that includes the weight of the slotted lens tubes, the lenses), it might be more efficient to clamp the telescope system itself on the rails with the low weight camera mounted on the lens tube.
I also went around to get an idea of distance of the GigE from the test masses. This was just a step to verify if the object distances were really in the ranges being taken into consideration, that is between 1500 and 2500 mm. I also tried to cross check the measurements with the CAD drawing of the 40m. However, as I have been informed, the distances in the CAD version are not updated.
The distances from the optic to the CCD detector would range from around 75.1 cm for MC2, 94.01 cm for ITMX, 97.21 cm for ETMX, 117.19 cm for ITMY and 88.463 cm for ETMY. The illuminator for the ETMY was disconnected, so Gautam helped me access the manual lamp control to enable me to take measurements.
The values for ETMX, MC2 and ITMY are subject to an error of ±1’’. Due to a lot of obstructions, the values for ETMY and ITMX may be subject to a lot more error. Even so, these distances are clearly less than 2 meters, prompting me to run the simulations again and verify that the chosen combination is still useful.
As for the slotted lens tubes to mount the 2” lenses, the following options are available on the Thorlabs catalog. CVI and Edmunds do not seem to offer much of the stackable lens tubes.
SM2L30C is a lens tube onto which the optic can be mounted without the need of a spanner wrench. It also has a length of 3”. However, it has a rotatable slip shield which can be rotated open as and when the access to optic is required. However, there might be a slight compromise with rigidity here.
SM2L30 is a lens tube with internal thread depth of 3”, the optic can be mounted using spanner wrench and a retainer ring. The optic cannot be accessed from both ends of the tube here.
SM2M30 is a lens tube with no external threads, therefore lens tube couplers would be required to stack the tubes. The optic is accessible from both ends here though.
Considering the merits and demerits of all these available options, the use of SM2L30 might be considered as it provides a quick and efficient way of stacking multiple lens tubes. As for accessing the optic from both sides, using multiple tubes helps overcome the problem and still ensures that we are able to access a number of separation distances as per requirement.
Thorlabs also offers an internal C to external SM2 adapter so that the lens tube could be fixed onto the C mount of the camera.
I would be examining the use of 1" diameter lenses for the eyepiece as suggested by Rana, as that might give us more flexibility. |
Attachment 1: Pictures1.pdf
|
|
12999
|
Fri May 19 19:18:53 2017 |
Kaustubh | Summary | General | Testing of the new Photo Detectors ET-3010 and ET-3040 |
Motivation:
I got some hands-on-experience on using RF photodetectors and the Network Analyzer from Koji. There were newly purchased RF photodetectors from Electro-Optics Technology, Inc.. These were InGaAs Photodetectors with model no.: 120-10050-0001(ET-3010) and 120-10056-0001(ET-3040). The User Guide for the two detectors can be found here. This is the first time we bought the ET-3010 model PD for the 40m lab. It has an operation bandwith >1.5GHz(not tested yet), much higher than other PDs of its kind. This can be used for detecting the output as we 'sweep' the laser frequency for getting data on the optical cavities and the resonating modes inside the cavity. We just tested out the ET-3040 model today but will test out the ET-3010 next week.
Tools and Machines Used:
We worked on the optical bench right in front of the main entrance to the lab. We put the cables, power chords, etc. to their respective places. We used screws, poles, T's, I's, multimeter, Network/Spectrum Analyzer(along with the moving table), a lab computer, Oscilloscope, power supply and the aforementioned PDs for our testing. We took these items from the stack of tools at the Y-arm and the boxes of various different labelled palced near the X-arm. We moved the Network Analyzer(along with the bench) from near the Y-arm to our workplace.
Procedure:
I will include a rough schematic of the setup later.
We alligned the reference PD(High Speed Photoreceiver model 1611) and the test PD(ET-3040 in this case) to get optimal power output. We had set the pump current for the laser at 19.5mA which produced a power of 1.00mW at the output of the fiber couple. At the reference detector the measured voltage was about 1.8V and at the DUT it was about 15mV. The DC transimpedance for the reference detector is 10kOhm and its responsivity to 1064 nm is around 0.75A/W. Using this we calculate the power at the reference detector to be 0.24mW. The DC transimpedance for the DUT is 50Ohm and the responsivity of about 0.9A/W. This amounts to a power of about 0.33mW. After measuring the DC voltages, we connected the laser input to the Network Analyzer and gave in an RF signal with -10dBm and frequency modulation from 100 kHz to 500 MHz. The RF output from the Analyzer is coupled to the Reference Channel(CHR) of the analyzer via a 20dB directional coupler. The AC output of the reference detector is given at Channel A(CHA) and the output from the DUT is given to Channel B(CHB). We got plots of the ratios between the reference detector, DUT and the coupled refernce for the Transfer Function and the Phase. We found that the cut-off frequency for the ET3040 model was at arounf 55 MHz(stated as >50MHz in the data sheet). We have stored the data using the lab PC in the directory .../scripts/general/netgpibdata/data.
Result:
The bandwidth of the ET-3040 PD is as stated in the data sheet, >50 MHz.
Precaution:
These PDs have an internal power supply of 3V for ET-3040 and 6V for ET-3010. Do not leave these connected to any instruments after the experiments have been performed or else the batteries will get drained if there is any photocurrent on the PDs.
To Do:
A similar procedure has to be followed in order to test the ET-3010 PD. I will be doing this tentatively on Monday. |
Attachment 1: IMG_20170519_173247922.jpg
|
|
Attachment 2: IMG_20170519_173253252.jpg
|
|
Attachment 3: IMG_20170519_173300174.jpg
|
|
Attachment 4: PD_test_setup.png
|
|
12998
|
Thu May 18 15:20:29 2017 |
jigyasa | Summary | telescope design | Telescope Design for the Gig-E cameras |
With the objective of designing a telescope system for the Gig-E, a system of two lenses is implemented. A rough schematic of the telescope system is attached. Variables in the system include the focal lengths of the two spherical lenses(f1, f2), distance between the lenses(t), distance between the test mass and the lens combination(u), distance between the other lens and the sensor(v). Also the size of the object to be desired ranges from 3’’ which is the size of the test mass to 1’’ which is approximately focusing on the beam spot implying that the required magnification ranges from 0.06089 to 0.1826 (since the sensor image circle size if ¼”)
The lenses are selected to be 2” in diameter so as to ensure sufficient collected power.
Going through the focal lengths available, namely 50, 100, 150, 200, 250 mm, and noting that the object distance would be within the ranges of 1500 to 2500 mm, plots of various accessible u and v for different values of t were obtained. This optimization was done to ensure the proper selection of the lenses. Additionally, a sensitivity analysis was performed and plots depicting the dependence of magnification on the precision limiting measurements of u (1 mm) and t (5 mm) were obtained. (These were scatter plots quantifying the deviation from the desired magnification ranges). The plots depict the error term induced on the magnification if there was an error in measuring the distance between the lenses as 5mm and if the precision in measuring the object to lens distance by 1mm.
The telescope design might be limited by spherical aberrations and coma, which might be resolved by either using aspherical lenses or by increasing the f-number (typically with an f number around 5 or 6). The use of aspherical lenses particularly parabolic lenses was considered, however this was found to be quite an expensive route.
Analyzing the plots and taking into consideration the restrictions of the slotted lens tubes, the precision in measurement of the distances, a 150 mm- 250mm focal length solution is proposed. With a diameter of 2”, the f number is computed to be 2.95 and 4.92. With this combination and the object distances lying between 1500 to 2500 mm, the image distance to the sensor varies between 51 to 100mm. So a slotted lens tube controlling the distance between the lenses would be required.
I also considered a combination of focal lengths 250mm and 250mm, as then both of the lenses would at least have an f number of 4.92. The results for this combination are also attached. The image distance from the lens combination is about a 100 to a 140 mm. However, this would require much longer slotted length tubes thereby adding to the cost of the system. The number of accessible u-v points is the same as that for the 150-250 combination.
I am still trying to search for a much more concrete way of quantifying aberrations. |
Attachment 1: ray.png
|
|
Attachment 2: Schematic.png
|
|
Attachment 3: 150-250uv.png
|
|
Attachment 4: 150-250error.png
|
|
Attachment 5: 250-250.png
|
|
Attachment 6: 250-250error.png
|
|
12997
|
Wed May 17 18:08:45 2017 |
Dhruva | Update | Optical Levers | Beam Profiling Setup |
Andrew and I set up the razor blade beam profiling experiment for He-Ne lasers on the "SP" table. Once I receive the laser safety training, I will make power measurements and fit it to an erfc curve from which I will calculate the gaussian profile of the beam. I'm attaching some pictures of the setup.
Least count of the micrometer - 2 microns
Laser : Lumentum 22037130:1103P
Photodetector : Thor Labs PDA100A |
Attachment 1: 1.jpg
|
|
Attachment 2: 2.jpg
|
|
Attachment 3: 3.jpg
|
|
Attachment 4: 4.jpg
|
|
Attachment 5: 5.jpg
|
|
12996
|
Wed May 17 11:10:31 2017 |
Steve | Update | Cameras | MC2 CCD video camera back in place |
Olympus camera is removed and our old CCD camera is back to monitor the face of MC2
Quote: |
Olympus SP570 UZ - without IR blocker, set up as Atm.3 Camera distance to MC face ~85 cm, IOO-MC_TRANS_SUM 16,300 counts, Lexan cover on not coated viewport.
Image mode: RAW + JPG, M-costum, manual focus, Lens: Olympus 4.6 - 92 mm, f2.8 - 4.5, Apeture: F2.8 - 8, Image pick up device: 1/2.33" CCD (primary color filter)
Atm.1, 212k.jpg of raw 15 MB, exp 0.025s, apeture 2.97, f 4.6, iso 64,
Atm.2, Copied through my Cannon S100 ( 3.3 MB.jpg of raw from UFraw photo shop )I will look up the original raw file for details.
|
|
12995
|
Wed May 17 08:19:59 2017 |
Steve | Update | SUS | 4.1M earthquake |
Sus dampings recovered. ETMY oplev needs to be recentered.
GV May 17 11am: I shut down the BS, SRM, ITMX and ITMY watchdogs, as the coil-driver boards for these optics are presently not installed.
|
Attachment 1: eq_4.1_SantaBarbara.png
|
|
Attachment 2: 4.1m_Isla_Vista_CA.png
|
|
12994
|
Tue May 16 16:16:16 2017 |
Steve | Update | safety | safety training |
Early surfs of India Jigyasa and Kaustubh received basic 40m specific safety traning. |
Attachment 1: surfs2017.jpg
|
|
12993
|
Mon May 15 20:43:25 2017 |
rana | Configuration | Computers | catastrophic multiple monitor failures |
this is not the right one; this Ethernet controlled strip we want in the racks for remote control.
Buy some of these for the MONITORS.
Quote: |
Surge protective power strip was install on Friday, May 5 in the Control Room
Computers not connected to the UPS are plugged into Isobar12ultra.
Quote: |
That's a new failure mode. Probably we can't trust the power to be safe anymore.
Need Steve to order a couple of surge suppressing power strips for the monitors. The computers are already on the UPS, so they don't need it.
|
|
|
12992
|
Mon May 15 19:21:04 2017 |
Koji | Update | Computer Scripts / Programs | FSSslow / MCautolocker restarted |
It seems that FSS slow servo stopped working.
I found that megatron was restarted (by Rana, to finish an apt-get upgrade) on ~18:47 PDT today.
controls@megatron|~> last -5
controls pts/0 192.168.113.216 Mon May 15 19:15 still logged in
controls pts/0 192.168.113.216 Mon May 15 19:14 - 19:15 (00:01)
reboot system boot 3.2.0-126-generi Mon May 15 18:50 - 19:19 (00:29)
controls pts/0 192.168.113.200 Mon May 15 18:43 - down (00:04)
controls pts/0 192.168.113.200 Mon May 15 15:25 - 17:38 (02:12)
FSSslow / MCautolocker were restarted on megatron.
|
12991
|
Mon May 15 08:26:43 2017 |
rana | Update | CDS | SVN up in userapps/cds |
I did an 'svn update' in userapps/cds/ which pulled in some changes from the sites as well as various CDS utilities in common/ and utilities/
This was to get Keith Thorne's get_data.m and get_data2.m scripts which I tested and they seem to be able to get data. No success with getting minute trend yet, but that may be a user error.
Update Monday 15-May: Our version of NDS client is 0.10 and we need to have 0.14 for this new method to work. Ubuntu12 lscsoft repo doesn't have newer nds client so we'll have to upgrade some OS. |
12990
|
Fri May 12 18:50:08 2017 |
gautam | Update | General | ITM and BS coil driver + dewhite board pulled out |
I've uploaded high-res photos + marked up schematics to the same DCC page linked in the previous page. I've noted the S/Ns of the ITM, BS and SRM boards on the page, I think it makes sense to collect everything on one page, and I guess eventually we will unify everything to a one or two versions.
To take the photos, I tried to reproduce the "LED light painting" technique reported here. I mounted the Canon EOS Rebel T3i on a tripod, and used some A3 sheets of paper to make a white background against which the board to be photographed was placed. I also used the new Macro lens we recently got. I then played around with the aperture and exposure time till I got what I judged to be good photos. The room lights were turned off, and I used the LED on my phone to do the "painting", from ~a metre away. I think the photos have turned out pretty well, the component values are readable.
Quote: |
I first set the bias sliders to 0 on the MEDM screen (after checking that the nominal values were stored), then shut down the watchdogs, and then pulled out the boards for inspection + photo-taking.
|
|
12989
|
Fri May 12 18:45:04 2017 |
rebecca | Update | Cameras | MC2 Pics with Olympus |
Raw and JPG formats of the pictures are saved on the Mac in the control room and at this link:
https://drive.google.com/open?id=0B9WDJpPRYby1c2xXRHhfOExXNFU
The camera was mounted using the JOBE arm wrapped around a small heavy piece of metal. The lights were kept on, the camera was zoomed in as closely as possible (so the light would take up most of the frame), F number of 8 was used, and shutter speeds from 1/2 to 1/100 seconds were used.
The pictures still look a bit blurry, probably because looking back at the details of the image, the focal length was 86.34m (as short of a focal length would be ideal, and Olympus is capable of going down to 1m).
Next steps include looking at the saturation in the pictures and setting up a more stable mount. |
12988
|
Fri May 12 12:34:55 2017 |
gautam | Update | General | ITM and BS coil driver + dewhite board pulled out |
I first set the bias sliders to 0 on the MEDM screen (after checking that the nominal values were stored), then shut down the watchdogs, and then pulled out the boards for inspection + photo-taking. |
12987
|
Fri May 12 01:36:04 2017 |
gautam | Update | General | SRM coil driver + dewhite board LISO modeling |
I've made the LISO models for the dewhitening board and coil driver boards I pulled out.
Attached is a plot of the current noise in the current configuration (i.e. dewhitening board just has a gain x3 stage, and then propagated through the coil driver path), with the top 3 noise contributions: The op-amps (op3 and op5) are the LT1125s on the coil driver board in the bias path, while "R12" is the Johnson noise from the 1k input resistace to the OP27 in the signal path.
Assuming the OSEMs have an actuation gain of 0.016 N/A (so 0.064 N/A for 4 OSEMs), the current noise of ~1e-10 A/rtHz translates to a displacement noise of ~3e-15m/rtHz at ~100Hz (assuming a mirror mass of 0.25kg).
I have NOT included the noise from the LM6321 current buffers as I couldn't find anything about their noise characteristics in the datasheet. LISO files used to generate this plot are attached.
Quote: |
I've added marked-up schematics + high-res photographs of the SRM coil driver board and dewhitening board to the 40m DCC Document tree (D1700217 and D1700218).
In the attached marked-up schematics, I've also added the proposed changes which Rana and I discussed earlier today. For the thick-film -> thin-film resistor switching, I will try and make a quick LISO model to see if we can get away with replacing just a few rather than re-stuff the whole board.
Since I have the board out, should I implement some of these changes (like AD797 removal) before sticking it back in and pulling out one of the ITM boards? I need to look at the locking transients and current digital limit-values for the various DoFs before deciding on what is an appropriate value for the output resistance in series with the coil.
Another change I think should be made, but I forgot to include on the markups: On the dewhitening board, we should probably replace the decoupling capacitors C41 and C52 with equivalent value electrolytic caps (they are currently tantalum caps which I think are susceptible to fail by shorting input to output).
|
|
Attachment 1: SRM_bypass_plus_CoilDriver.pdf
|
|
Attachment 2: liso.zip
|
12986
|
Thu May 11 18:59:22 2017 |
gautam | Update | General | SRM coil driver + dewhite board initial survey |
I've added marked-up schematics + high-res photographs of the SRM coil driver board and dewhitening board to the 40m DCC Document tree (D1700217 and D1700218).
In the attached marked-up schematics, I've also added the proposed changes which Rana and I discussed earlier today. For the thick-film -> thin-film resistor switching, I will try and make a quick LISO model to see if we can get away with replacing just a few rather than re-stuff the whole board.
Since I have the board out, should I implement some of these changes (like AD797 removal) before sticking it back in and pulling out one of the ITM boards? I need to look at the locking transients and current digital limit-values for the various DoFs before deciding on what is an appropriate value for the output resistance in series with the coil.
Another change I think should be made, but I forgot to include on the markups: On the dewhitening board, we should probably replace the decoupling capacitors C41 and C52 with equivalent value electrolytic caps (they are currently tantalum caps which I think are susceptible to fail by shorting input to output). |
Attachment 1: D010001-B_40m.pdf
|
|
Attachment 2: D000183-C8_40m.pdf
|
|
12985
|
Thu May 11 09:45:46 2017 |
rana | Update | General | DAC / Coil Driver noise - SRM coil driver + dewhite board removed |
I believe the ETMs and ITMs are different from the others. |
12984
|
Wed May 10 17:46:44 2017 |
gautam | Update | General | DAC / Coil Driver noise - SRM coil driver + dewhite board removed |
I've removed the SOS coil driver (D010001-B, S/N B151, labelled "SRM") + Universal Dewhitening Board (D000183 Rev C, S/N B5172, labelled "B5") combo for SRM from 1X4, for photo taking + inspection.
I first shutdown the SRM watchdog, noted cabling between these boards and also the AI board as well as output to Sat. Box. I also needed to shutdown the MC2 watchdog as I had to remove the DAC output to MC2 in order to remove the SRM Dewhitening board from the rack. This connection has been restored, MC locks fine now.
|
12983
|
Wed May 10 17:17:05 2017 |
gautam | Update | General | DAC / Coil Driver noise |
Suspension Actuator noise:
There are 3 main sources of electronics noise which come in through the coil driver:
- Voltage noise of the coil driver.
- The input referred noise is ~5 nV/rHz, so not a big issue.
- The Johnson noise of the output resistor which is in series with the coil is sqrt(4*k*T*R) ~ 3 nV/rHz. We probably want to increase this resistor from 200 to 1000 Ohms once Gautam convinces us that we don't need that range for lock acquisition.
- Voltage noise of the dewhitening board.
- In order to reduce DAC noise, we have a "dewhitening" filter which provides some low passing. There is an "antiDW" filter in the digital part which is the inverse of this, so that when they are both turned on, the result is that the main signal path has a flat transfer function, but the DAC noise gets attenuated.
- In particular, ours have 2 second order filters (each with 2 poles at 15 Hz and 2 zeros at 100 Hz).
- We also have a passive pole:zero network at the output which has z=130, 530 Hz and p = 14, 3185 Hz.
- The dewhitening board has an overall gain of 3 at DC to account for our old DACs having a range of +/-5 V and our coil drivers having +/- 15 V power supplies. We should get rid of this gain of 3.
- The dewhitening board (and probably the coil driver) use thick film resistors and so their noise is much worse than expected at low frequencies.
- DAC voltage noise.
- The General Standards 16-bit DACs have a noise of ~5 uV/rHz.
- the satellite box is passive and not a significant source of noise; its just a flaky construction and so its problematic.
|
Attachment 1: actuation.jpg
|
|
12982
|
Wed May 10 16:57:52 2017 |
rana | Update | CDS | MCautolocker dead |
I rebooted megatron around 12:20 today. It had dozens of stalled medm process (some of them there since February!). I couldn't kill them without them coming back like zombies, so I did sudo reboot. |
12981
|
Wed May 10 16:53:38 2017 |
rana | Update | General | MICH NB - OL coupling |
That's a good find.
- The OL control signal can be gotten from the DQ error signal. You just need to multiply it by the digital filters and the gain. The state of the filters and the gain can be gotten using matlab tools like getFotonFilt.m. For python ChrisW wrote a tool called foton.py which is in the GDS SVN. You should ask him for it. It requires access to some ROOT libraries to run.
- We should have sub budgets for everything like OL and thermal, etc. They should be automatically produced each time you run the main budget and should be separate pages in the same PDF file. Jamie / Chris may have something going along these lines so check to see if they are already on it.
|
12980
|
Wed May 10 12:37:41 2017 |
gautam | Update | CDS | MCautolocker dead |
The MCautolocker had stalled - there were no additional lines to the logfile after 12:17pm (~20mins ago). Normally, it suffices to ssh into megatron and run sudo initctl restart MCautolocker - but it seems that there was no running initctl instance of this, so I had to run sudo initctl start MCautolocker. The FSS Slow control initctl process also seemed to have been terminated, so I ran sudo initctl start FSSslowPy.
It is not clear to me why the initctl instances got killed in the first place, but MC locks fine now. |
12979
|
Wed May 10 01:56:06 2017 |
gautam | Update | General | MICH NB - OL coupling |
Last night, I tried to estimate the contribution of OL feedback signal to the MICH length error signal.
In order to do so, I took a swept sine measurement with a few points between 50 Hz and 500 Hz. The transfer function between C1:LSC-MICH_OUT_DQ and the Oplev Servo Output point (e.g. C1:SUS-BS_OL_PIT_OUT etc) was measured. I played around with the excitation amplitude till I got coherence > 0.9 for the TF measurement, while making sure I wasn't driving the Oplev error point too hard that side-lobes began to show up in the MICH control signal spectrum.
The Oplev control signal is not DQ-ed. So I locked the DRMI again and downloaded the 16k data "live" for ~5min stretch using cdsutils.getdata on the workstation. The Oplev error point is DQ-ed at 2k, but I found that the excitation amplitude needed for good SNR at the error point drove the servo to the limiter value of 2000cts - so I decided to use the control signal instead. Knowing the transfer function from the Oplev *_OUT* channel to C1:LSC-MICH_IN1_DQ, I backed out the coupling - the transfer function was only measured between 50 Hz and 500 Hz, and no extrapolation is done, so the estimation is only really valid in this range, which looks like where it is important anyways (see Attachment #2, contributions from ITMX, ITMY and BS PIT and YAW servos added in quadrature).
I was also looking at the Oplev servo shapes and noticed that they are different for the ITMs and the BS (Attachment #1). Specifically, for the ITM Oplevs, an "ELP15" is used to do the roll-off while an "ELP35" is employed in the BS servo (though an ELP35 also exists in the ITM Oplev filter banks). I got lost in an elog search for when these were tuned, but I guess the principles outlined in this elog still hold and can serve as a guideline for Oplev loop tweaking.
Coil driver noise estimation to follow
Quote: |
I think the most important next two items to budget are the optical lever noise, and the coil driver noise. The coil driver noise is dominated at the moment by the DAC noise since we're operating with the dewhitening filters turned off.
|
GV 10 May 12:30pm: I've uploaded another copy of the NB (Attachment #3) with the contributions from the ITMs and BS separated. Looks like below 100Hz, the BS coupling dominates, while the hump/plateau around 350Hz is coming from ITMX. |
Attachment 1: OL_BS_ITM_comp.pdf
|
|
Attachment 2: C1NB_disp_40m_MICH_NB_8_May_2017.pdf
|
|
Attachment 3: C1NB_disp_40m_MICH_NB_10_May_2017.pdf
|
|
12978
|
Tue May 9 15:23:12 2017 |
Steve | Configuration | Computers | catastrophic multiple monitor failures |
Gautam and Steve,
Surge protective power strip was install on Friday, May 5 in the Control Room
Computers not connected to the UPS are plugged into Isobar12ultra.
Quote: |
That's a new failure mode. Probably we can't trust the power to be safe anymore.
Need Steve to order a couple of surge suppressing power strips for the monitors. The computers are already on the UPS, so they don't need it.
|
|
Attachment 1: Trip-Lite.jpg
|
|
12977
|
Mon May 8 21:53:56 2017 |
rana | Summary | SEI | attempt to get seismic BLRMS minute trend |
I tried to get some minute trend data today, but was unable to get it from inside or outside the control room using our matlab or python tools.
It seems the NDS2 interface will not work anywhere since it needs our minute trends to be written as frames; in the last version that Jamie left us, our minute trend frame files are not being written since they lead to periodic daqd crashes.
From inside the control room, we can get the minute trend (only with DataViewer). I've attached 30 days of BS_X just to show its real.
We can get the numerical data from the Grace plot window using the menu option Data->Export->ASCII.
You must select all of the 'Write Sets' to get all of the traces in the plot window. The resulting ascii file is not in a great format, but its not terrible. |
Attachment 1: BLRMS_trend.png
|
|
12976
|
Sat May 6 21:52:11 2017 |
rana | Update | General | MICH NB questions |
I think the most important next two items to budget are the optical lever noise, and the coil driver noise. The coil driver noise is dominated at the moment by the DAC noise since we're operating with the dewhitening filters turned off. |
12975
|
Fri May 5 12:10:53 2017 |
gautam | Update | General | MICH NB questions |
Quote: | Is suspension thermal noise missing? I take it "Thermal" refers just to thermal things going on in the optic, since I don't see any peaks at the bounce/roll modes as I would expect from suspension thermal noise. What goes into the GWINC calculation of seismic noise? Does it include real 40m ground motion data and our seismic stacks? I'm surprised to see such a sharp corner in the "Dark Noise" trace, did you apply the OLG correction to a measured dark noise ASD? (The OLG correction only needs to be applied to the in-lock error signals to recover open loop behavior, there is no closed loop when you're measuring the dark noise so nothing to correct for.) |
I've included the suspension thermal noise in the "Thermal" trace, but I guess the GWINC file I've been using to generate this trace only computes the thermal noise for the displacement DoF. I think this paper has the formulas to account for them, I will look into including these.
For the seismic noise, I've just been using the seis40.mat file from the 40m SVN. I think it includes a model of our stacks, but I did not re-calculate anything with current seismometer spectra. In the NB I updated yesterday, however, I think I was off by a factor of sqrt(3) as I had only included the seismic noise from 1 suspended optic. I've corrected this in the attached plot.
For the dark noise, you are right, I had it grouped in the wrong dictionary in the code so it was applying the OLG inversion. I've fixed this in the attached plot. |
Attachment 1: C1NB_disp_40m_MICH_NB_30_April_2017.pdf
|
|
12974
|
Fri May 5 10:13:02 2017 |
ericq | Update | General | MICH NB questions |
Is suspension thermal noise missing? I take it "Thermal" refers just to thermal things going on in the optic, since I don't see any peaks at the bounce/roll modes as I would expect from suspension thermal noise.
What goes into the GWINC calculation of seismic noise? Does it include real 40m ground motion data and our seismic stacks?
I'm surprised to see such a sharp corner in the "Dark Noise" trace, did you apply the OLG correction to a measured dark noise ASD? (The OLG correction only needs to be applied to the in-lock error signals to recover open loop behavior, there is no closed loop when you're measuring the dark noise so nothing to correct for.) |
12973
|
Fri May 5 08:41:42 2017 |
Steve | Update | Cameras | MC2 resonant pictures |
Olympus SP570 UZ - without IR blocker, set up as Atm.3 Camera distance to MC face ~85 cm, IOO-MC_TRANS_SUM 16,300 counts, Lexan cover on not coated viewport.
Image mode: RAW + JPG, M-costum, manual focus, Lens: Olympus 4.6 - 92 mm, f2.8 - 4.5, Apeture: F2.8 - 8, Image pick up device: 1/2.33" CCD (primary color filter)
Atm.1, 212k.jpg of raw 15 MB, exp 0.025s, apeture 2.97, f 4.6, iso 64,
Atm.2, Copied through my Cannon S100 ( 3.3 MB.jpg of raw from UFraw photo shop )I will look up the original raw file for details.
|
Attachment 1: P5040028MC2c.jpg
|
|
Attachment 2: IMG_3682.JPG
|
|
Attachment 3: IMG_3688.JPG
|
|
12972
|
Thu May 4 19:03:15 2017 |
gautam | Update | General | DRMI locking - preliminary MICH NB |
Summary:
I've been playing around with Evan's NB code trying to put together a noise budget for the data collected during the DRMI locks last week. Here is what I have so far.
Attachment #1: Sensing matrix measurement.
- This is basically to show that the MICH error signal is mostly in AS55Q.
- The whitening gain used was 0dB, and the demod phase was -82 degrees.
- The MICH sensing response was 5.31*10^8 V/m, where V is the demod board output. The 40m wiki RFPD page for AS55 says the RF transimpedance is ~550ohms, and I measured the Demod Board puts out 5.1V of IF signal (measured at after the Preamp, which is what goes to the ADC) for 1V of RF signal at the PD input. Using these numbers, and assuming a PD responsivity of 0.8 A/W at 1064nm, the sensing response is 2.37*10^5 W/m. I don't have a feeling yet for whether this is a reasonable number, but it would be a number to compare to what my Finesse model tells me to expect, for example.
- Actuator calibration used to arrive at these numbers was taken from this elog.
Attachment #2: MICH OLTF measurement vs model
- In order to build the MICH OLTF model, I used MATLAB to put together the following transfer functions:
- BS pendulum
- Digital servo filters from LSC_MICH
- Violin mode filters
- Analog/Digital AA and AI filters. For the digital AA/AI filters, I took the coefficients from /opt/rtcds/rtscore/release/src/fe/controller.c
- The loop measurement was taken with digital filter modules FM1, FM2, FM3, FM7, FM9 engaged.
- In order to fit the model to the measurement, I tried finding the best-fit values for an overall loop gain and delay.
- The agreement between model and measurement isn't stellar, but I decided to push ahead for a first attempt. This loop TF was used to convert various noises into displacement noise for plotting.
Attachment #3: Noise budget
- It took me a while to get Evan's code going, the main changes I made were to use nds2 to grab data instead of GWPy, and also to replace reading in .txt files with importing .mat files. This is a work in progress.
- Noises plotted:
- Measured - I took the in loop error signal and estimated the free-running displacement noise with the model OLTF, and calibrated it into metres using the sensing response measurement. This looks consistent with what was measured back in Dec 2015.
- Shot noise - I used the measured DC power incident on the PD, 13mW, RF transimpedance of 550 V/A, and the V/m calibration factor mentioned above, to calculate this (labelled "Quantum Noise").
- Dark noise - measured with PSL shutter closed.
- Seismic noise, thermal noise, gas noise - calculated with GWINC
I think I did the various conversions/calibrations/loop algebra correctly, but I may have overlooked something. Now that the framework for doing this is somewhat set up, I will try and put together analogous NBs for PRCL and SRCL.
GV 22 August 2017: Attachment #4 is the summary of my demod board efficiency investigations, useful for converting sensing measurement numbers from cts/m to W/m. |
Attachment 1: DRMI_noArms_April30.pdf
|
|
Attachment 2: MICH_OLTF.pdf
|
|
Attachment 3: C1NB_disp_40m_MICH_NB_30_April_2017.pdf
|
|
Attachment 4: 40m_REFL_RFPDs_efficiency.pdf
|
|
12971
|
Thu May 4 09:52:43 2017 |
rana | Configuration | Computers | catastrophic multiple monitor failures |
That's a new failure mode. Probably we can't trust the power to be safe anymore.
Need Steve to order a couple of surge suppressing power strips for the monitors. The computers are already on the UPS, so they don't need it. |
12970
|
Thu May 4 08:00:54 2017 |
Steve | Update | safety | safety training |
Freshmen Rebecca Zhang as " work study undergrad " received 40m specific basic safety training yesterday. |
12969
|
Wed May 3 18:45:45 2017 |
rana | Update | General | DRMI locking |
Quote: | Comparing counts doesn't get you anywhere; each PD has different whitening gain which may vary from measurement to measurement. The better thing to compare is Volts coming out of the demod board, since this (hopefully) only changes when we touch the PD or analog signal chain; this is what I used for the most recent DRMI sensing measurements. (ELOG 11589) We have calibrated actuator channels in the CAL model, which will give you the control signal in m for the DRMI lengths. Perhaps you can convert your sensing matrix measurement to demod board output volts per meter to compare with the last measurement.
Also, the monitor ports are the LEMO ports to the left; the SMA ports where the signal is coming from are from a daughter board that has a better output opamp that the nominal output; we're using the same output on the REFL11 and AS55 demod boards. |
Wrong! RTFS.
SMA outputs are the bare, passive outputs of the mixer/lowpass.
TNC outputs are the low-noise, acti amplified outputs via the daughter board.
LEMO outputs are the high noise, G=2, LT1125 buffered outputs |
12968
|
Wed May 3 17:16:30 2017 |
Praful | Update | Electronics | New Altium Schematic Design for Microphone Amp |
I made an Altium schematic for the microphone amplifier circuit for fabrication.
mic_schematicv2.pdf |
Attachment 1: mic_schematicv2.pdf
|
|
12967
|
Wed May 3 16:47:45 2017 |
Koji | Update | General | PI pzt inventory check |
I also have a functional one on my desk, which has one of the wires repaired.
Quote: |
One is broken, two are ready to steer green and 3 available in un known condition
|
|
12966
|
Wed May 3 16:46:18 2017 |
Koji | Configuration | Computers | catastrophic multiple monitor failures |
- Is there any machine that can handle 4K? I have one 4K LCD for no use.
- I also can donate one 24" Dell |
12965
|
Wed May 3 16:12:36 2017 |
johannes | Configuration | Computers | catastrophic multiple monitor failures |
It seems we lost three monitors basically overnight.
The main (landscape, left) displays of Pianosa, Rossa and Allegra are all broken with the same failure mode:
their backlights failed. Gautam and I confirmed that there is still an image displayed on all three, just incredibly faint. While Allegra hasn't been used much, we can narrow down that Pianosa's and Rossa's monitors must have failed within 5 or 6 hours of each other, last night.
One could say ... they turned to the dark side 

Quick edit; There was a functioning Dell 24" monitor next to the iMac that we used as a replacement for Pianosa's primary display. Once the new curved display is paired with Rossa we can use its old display for Donatella or Allegra. |
12964
|
Wed May 3 16:02:36 2017 |
Steve | Update | General | PI pzt inventory check |
One is broken, two are ready to steer green and 3 available in un known condition
|
Attachment 1: IMG_3678.JPG
|
|
Attachment 2: PIpztETMYgreen.jpg
|
|
12963
|
Wed May 3 16:00:00 2017 |
gautam | Summary | General | Network Topology Check |
[johannes, gautam]
I forgot we had done this last year already, but we updated the control room network switch labels and double checked all the connections. Here is the status of the connections and labels as of today:

There are a few minor changes w.r.t. labeling and port numbers compared to the Dec 2015 entry. But it looks like there was no IP clash between Rossa and anything (which was one of the motivations behind embarking on this cleanup). We confirmed by detatching the cable at the PC end of Rossa, and noticed the break in the ping signals. Plugging the cable back in returned the pings. Because Rossa is currently un-bootable, I couldn't check the MAC address.
We also confirmed all of this by using the web browser interface for the switch (IP = 192.168.113.249). |
Attachment 1: Network_topology_3May2017.pdf
|
|
12962
|
Mon May 1 21:45:54 2017 |
ericq | Update | General | DRMI locking |
Comparing counts doesn't get you anywhere; each PD has different whitening gain which may vary from measurement to measurement. The better thing to compare is Volts coming out of the demod board, since this (hopefully) only changes when we touch the PD or analog signal chain; this is what I used for the most recent DRMI sensing measurements. (ELOG 11589) We have calibrated actuator channels in the CAL model, which will give you the control signal in m for the DRMI lengths. Perhaps you can convert your sensing matrix measurement to demod board output volts per meter to compare with the last measurement.
Also, the monitor ports are the LEMO ports to the left; the SMA ports where the signal is coming from are from a daughter board that has a better output opamp that the nominal output; we're using the same output on the REFL11 and AS55 demod boards. |