1313
|
Mon Feb 16 21:49:06 2009 |
Kakeru, Rana | Update | IOO | WFS |
We centerd the input of WFS QPD. |
1312
|
Mon Feb 16 20:47:48 2009 |
rana | Configuration | IOO | Mode Cleaner WFS Loop Gain change |
I found the MCWFS gain slider down at 0.012. In this state the UGFs are probably around 10-30 mHz
and so there is no reduction of seismic noise. It is mainly a DC alignment tool in this state.
We often have reduced the loop gain thusly, to prevent the dreaded "MCWFS eating CM loop gain" disease.
That disease is where there are CM loop instabilities at ~5-30 Hz because of loop cross-couplings
who's exact nature has never been understood (TBI).
Today, I implemented a 4th order, 7 Hz low pass (RLP7) into the loops and turned up the gain by a factor
of 30 to 0.3. In this state, the damping time constants seem to be ~0.5-2 seconds as shown in the first
PDF. I didn't have enough patience to do the interminable swept sine measurements down to 0.1 Hz.
The second PDF shows the Bode plot of the RLP7 filter compared to the pre-existing but unused ELP10.
The third PDF shows my estimate of the OLG TF. This is made by just putting a "Pendulum" filter into the
MCWFS bank and then plotting all the filters together using FOTON. The BLUE curve shows the old TF but
with the new high gain and the RED curve shows the new TF with the new gain.
With this new filter, I bet that we can get away with the higher WFS gain, but if there's any problem during the
handoff, the gain should be reverted to the low value.
In the 4th PDF file, I plot the spectra of 4 of MC2's control signals so that you can see what is bigger than what.
ASCPIT is the one that has the feedback from the WFS's in it. These are all just in units of counts and so to compare
them in some sort of displacement units you have to take into account the pitch moment of inertia, the mirror mass,
and the mis-centering of the beam from the center of rotation of MC2... |
Attachment 1: pmc-pzt-cal.pdf
|
|
Attachment 2: a.pdf
|
|
Attachment 3: olg.pdf
|
|
Attachment 4: mc2.pdf
|
|
1311
|
Mon Feb 16 16:26:29 2009 |
rob | Update | Computers | medm directory wiped on nodus |
Quote: |
Quote: | I accidentally did an 'rm -rf' on the medm directory in nodus, instead of on my laptop as was intended.
I then did an svn checkout. So everything should be current as of the last update, but I am sure that
we have not done a checkin on all of the latest screen enhancements. So...we may have to revert to the
Sunday morning tar to get the latest changes back. |
Indeed, some changes to the medm directory I made were lost.
It was my fault not to check-in those changes.
I asked Alan to restore the directory from the daily rsync backup.
However, the backup job executed this morning have already overwritten the previous (good) backup with the current (bad) medm directory, which Rana restored from the svn. Alan will ask Stuart and Phil if there is still older backup remaining somewhere.
Anyway, I realized that we should stop the backup cron job whenever you think you made a mistake on /cvs/cds/ directory to prevent unwanted overwriting.
The procedure is:
(1) Login to fb40m
(2) Type 'crontab -e'. Emacs will open up in the terminal.
(3) Comment out the backup job (insert # at the beginning of the line containing /cvs/cds/caltech/scripts/backup/rsync.backup ).
(4) Save the file (Ctrl-x Ctrl-s) and exit (Ctrl-x Ctrl-c).
I will post this information on the wiki. |
We should change the rsync script so that it does not delete stuff. Maybe it can keep deleted stuff for 6 months or something. |
1310
|
Mon Feb 16 15:54:07 2009 |
Yoichi | Update | Computers | medm directory wiped on nodus |
Quote: | I accidentally did an 'rm -rf' on the medm directory in nodus, instead of on my laptop as was intended.
I then did an svn checkout. So everything should be current as of the last update, but I am sure that
we have not done a checkin on all of the latest screen enhancements. So...we may have to revert to the
Sunday morning tar to get the latest changes back. |
Indeed, some changes to the medm directory I made were lost.
It was my fault not to check-in those changes.
I asked Alan to restore the directory from the daily rsync backup.
However, the backup job executed this morning have already overwritten the previous (good) backup with the current (bad) medm directory, which Rana restored from the svn. Alan will ask Stuart and Phil if there is still older backup remaining somewhere.
Anyway, I realized that we should stop the backup cron job whenever you think you made a mistake on /cvs/cds/ directory to prevent unwanted overwriting.
The procedure is:
(1) Login to fb40m
(2) Type 'crontab -e'. Emacs will open up in the terminal.
(3) Comment out the backup job (insert # at the beginning of the line containing /cvs/cds/caltech/scripts/backup/rsync.backup ).
(4) Save the file (Ctrl-x Ctrl-s) and exit (Ctrl-x Ctrl-c).
I will post this information on the wiki. |
1309
|
Mon Feb 16 14:12:21 2009 |
Yoichi | Update | LSC | FE system rebooted |
Quote: |
I can't restart the MC autolocker on c1susvme2 because it doesn't let me ssh in. I tried to reboot it a few times but it didn't work. Once you restart it, it becomes inaccessible and doesn't even respond to pinging. Although the controls for the MC mirrors are on.
The mode cleaner stays unlocked. |
MC autolocker runs on op340m, not on c1susvme2.
I restarted it and now MC locks fine.
Before that, I had to reboot c1iool0 and restore the alignment of the MC mirrors (for some reason, burt did not restore the alignment properly, so I used conlog). |
1308
|
Mon Feb 16 10:18:13 2009 |
Alberto | Update | LSC | FE system rebooted |
Quote: |
Quote: |
I didn't get a chance to do much testing since the sus controller (susvme1) went nuts. In retrospect, this could be due to something in the script, so maybe we should try a burt restore to Friday afternoon next time someone wants to look at it. |
I tried the burtrestore today, it didn't work. Also tried some switching of timing cables, and multiple reboots, to no avail. This will require some more debugging. We might try diagnosing the clock driver and fanout modules, the penteks, and we can also try rebooting the whole FE system. |
I rebooted the whole FE system and now c1susvme1 and c1susvme2 are back on.
I can't restart the MC autolocker on c1susvme2 because it doesn't let me ssh in. I tried to reboot it a few times but it didn't work. Once you restart it, it becomes inaccessible and doesn't even respond to pinging. Although the controls for the MC mirrors are on.
The mode cleaner stays unlocked. |
1307
|
Mon Feb 16 00:43:46 2009 |
rana | Update | Computers | medm directory wiped on nodus |
I accidentally did an 'rm -rf' on the medm directory in nodus, instead of on my laptop as was intended.
I then did an svn checkout. So everything should be current as of the last update, but I am sure that
we have not done a checkin on all of the latest screen enhancements. So...we may have to revert to the
Sunday morning tar to get the latest changes back. |
1306
|
Sun Feb 15 15:53:21 2009 |
Rob | Update | LSC | Locking status |
Quote: |
I didn't get a chance to do much testing since the sus controller (susvme1) went nuts. In retrospect, this could be due to something in the script, so maybe we should try a burt restore to Friday afternoon next time someone wants to look at it. |
I tried the burt restore today, it didn't work. Also tried some switching of timing cables, and multiple reboots, to no avail. This will require some more debugging. We might try diagnosing the clock driver and fanout modules, the penteks, and we can also try rebooting the whole FE system. |
1305
|
Sun Feb 15 09:35:00 2009 |
Yoichi | Update | LSC | Locking status |
Quote: |
I found a '$<' in the offloadMCF script. I don't know precisely what that construct means, but I think it caused the script to wait for input when it shouldn't.
|
'$<' acts like 'read' in csh. I might have put it in the offloadMCF script to debug the behavior of the script.
Sorry I probably forgot to remove it from the script when I left. |
1304
|
Sat Feb 14 16:53:26 2009 |
rob | Update | LSC | Locking status |
Quote: | Yoichi, Jenne, Alberto, Rob
Last night, the locking proceeded until the CARM -> MC_L hand-off.
However, the MC_F gets saturated (as expected) and the IFO loses lock soon after the hand-off.
So we need to offload MC_F.
We ran the offloadMCF script, but it did not work, i.e. just waiting for CARM mode.
Looks like an EPICS flag is not set right. |
I found a '$<' in the offloadMCF script. I don't know precisely what that construct means, but I think it caused the script to wait for input when it shouldn't. It probably got in there accidentally. We need to be careful when we're opening scripts just to look at how they work that we don't accidentally change them. I like to use the command 'less' for this purpose.
With this gone, the script worked properly, although the lock didn't last long. I don't know if the next stage in the process is failing or if it's just a bit too noisy in the afternoon. I didn't get a chance to do much testing since the sus controller (susvme1) went nuts. In retrospect, this could be due to something in the script, so maybe we should try a burt restore to Friday afternoon next time someone wants to look at it. |
1303
|
Sat Feb 14 16:15:19 2009 |
rob | Configuration | Computers | c1susvme1 |
c1susvme1 is behaving weirdly. I've restarted it several times but its computation time is hanging out around 260 usec, making it useless for suspension control and locking. I also found a PS/2 keyboard plugged in, which doesn't work, so I unplugged it. It needs to be plugged into a PS/2 keyboard/mouse Y-splitter cable. |
1302
|
Fri Feb 13 16:30:49 2009 |
steve | Configuration | General | status quo is disturbed |
I have been getting ready for the annual safety inspection in the past 2-3 days.
Meaning cleaning up and disturbing the status quo on the floor mostly under the optical tables and their surroundings.
For example: pd power supplies, He/Ne laser ps. and their positions.
BNC cables and ac power line positions can be different.
The new rule: no electronic equipment on the floor.
All electronic equipment were moved-placed into a plastic dish or tray. |
1301
|
Fri Feb 13 13:35:38 2009 |
Yoichi | Update | LSC | Locking status |
Yoichi, Jenne, Alberto, Rob
Last night, the locking proceeded until the CARM -> MC_L hand-off.
However, the MC_F gets saturated (as expected) and the IFO loses lock soon after the hand-off.
So we need to offload MC_F.
We ran the offloadMCF script, but it did not work, i.e. just waiting for CARM mode.
Looks like an EPICS flag is not set right. |
1300
|
Fri Feb 13 08:38:03 2009 |
steve | Update | IOO | MC2 damping restored |
|
1299
|
Thu Feb 12 18:35:10 2009 |
Kakeru | Configuration | PSL | PA current limitter |
I added a PA current limiter.
It is only a voltage devider (composed with 3.09k and 1.02k resiste) between DAC and PA current adjustment input.
The output range of DAC is +/- 10[V] and the conversion factor of PA current adjustment is 0.84[A/V] (measured value), so the PA current adjustment is limited +/- 2.1[A] ( 10[V]*1.02k/(1.02k+3.09k)*0.84[A/V] ).
Actually, the manual of the PA tells that the conversion factor is 0.25[A/V].
There is 3 possibility.
1) There are some mistakes in channels of digital system.
2) The PA manual is wrong.
2-1) The conversion factor of current adjustment is wrong.
2-2) The conversion factor of current monitor is wrong.
I measured the signal of current adjustment and current monitor directly, and confirm that they are consistent to the value monitord from MEDM.
Hence the PA manual must be wrong, but I don't know which factor is wrong (or both?).
If the suspect 2-2) is guilty, it means we adjust PA current with very small range.
This is a completly safety way, but a wast of resource.
Now, the slider to control current adjustment indicate the output of DAC.
I will improve this to indicate current adjustment input, but it takes some time for me to learn about EPICS.
|
1298
|
Thu Feb 12 17:43:33 2009 |
Yoichi | Update | LSC | SRC strangeness solved |
I found the problem with the DRMI lock I had last night was caused by the zero gain in the PD11_I filter.
I don't know how it happened but putting it back to 1.000 made the DRMI lock far more stable and AS166Q got more than 3000.
I also re-centered POY PD to remove the offset in the y-arm loop. The large power drops while y-arm is locked by itself were eliminated. |
1297
|
Thu Feb 12 14:39:07 2009 |
rana | Summary | General | Silicon Beam Dump test |
Yesterday evening, Ken Mailand and I tested the reflectivity of a piece of polished Silicon. Since Silicon has such a high thermalconductivity (compared to stainless and fused silica) and can take much more heat than black glass and should have a very good BRDF and should absorb most of the 1064 nm light if we hit it at Brewster's angle, we want to try it out in the first version high power, low scatterbeam dump. This dump will be a 'V' style dump like what Steve has tested nearly a year ago, but the incoming beam will first hit this piece of Silicon.
The pictures of the setup and the Silicon with the beam hitting it are here.
Brewster's angle for p-pol at 1064 nm is 74.2 deg (n = 3.53 @ 1064 nm). We set up a cube polarizer on the output of the ~1064 nm CrystaLaser. 144 mW got to the Si; the reflected beam was ~1.9-2.0 mW after tuning the angle for minimum power. Via eyeball and protractor it seems that we're at ~74 deg. So the reflectivity is < 1.5-2%. This is good enough; the reflected power will be < 1 W in all cases for eLIGO and that can be absorbed by the rest of the stainless V dump. The 35 W of heat in the silicon will be mostly gotten rid of through conduction into the attached heat sink fins.
This kind of dump would go into places like the PMC-REFL, MC-REFL, & IFO-REFL, where we occasionally need to take high power, but also are sensitive to backscatter. |
1296
|
Thu Feb 12 11:21:54 2009 |
Yoichi | Update | LSC | Locking effort resumed |
Last night, I restarted the locking work.
Quite some time was wasted by the disconnected REFL199 by Alberto for the cavity length measurement.
From now on, please put the interferometer back to the original state every day.
If possible, please refrain from changing the IFO settings (cabling, optics, etc).
It is also very important to always restore the full IFO alignment after you are done with your work.
While I was working on the optimization of the DD hand-off, the DRMI alignment got into a strange state.
Even when I did the whole dither alignment procedure from the beginning (from x-arm), the AS166Q did not go above 1000.
PRMI looks ok (SPOB goes above 1100). I could lock the DRMI but the lock position hops to other modes easily.
Manual tweaks of SRM did not help.
After running the whole alignment procedure several times in vain, I was too tired and went home.
I noticed that the single arm lock shows power drops again. There are some offsets in the arm lock loops.
This may have prevented the Michelson alignment from being optimal. I will check this today. |
1295
|
Wed Feb 11 23:51:53 2009 |
Kakeru | Update | PSL | PA current and laser output |
I attached a plot of ISS monitor PD and MOPA output to PA current.
The both end of PA current (26.0353[A] and 28.4144[A]) correspond to the slider value of -2.0 and 1.0 .
It looks that we must use MOPA with PA current below 27.5[A]. |
Attachment 1: PA_current_output.png
|
|
1294
|
Wed Feb 11 15:01:47 2009 |
josephb | Configuration | Computers | Allegra |
So after having broke Allegra by updating the kernel, I was able to get it running again by copying the xorg.conf.backup file over xorg.conf in /etc/X11. So at this point in time, Allegra is running with generic video drivers, as opposed to the ATI specific and proprietary drivers. |
1293
|
Wed Feb 11 11:39:17 2009 |
steve | Configuration | General | vac envelope ground |
The vacuum envelope was grounded from the IOO chamber to master ground north (under electric breaker panel L)
with 4GA 25ft red battery cable.
|
1292
|
Wed Feb 11 10:52:22 2009 |
Yoichi | Configuration | DAQ | C1:PEM-OSA_APTEMP and C1:PEM-OSA_SPTEMP disconnected |
During the cleanup of the lab. Steve found a box with two BNCs going to the ICS DAQ interface and an unconnected D-SUB on the floor under the AP table. It seemed like a temperature sensor.
The BNCs were connected to C1:PEM-OSA_APTEMP and C1:PEM-OSA_SPTEMP.
Steve removed the box from the floor. These channels can be now used as spare DAQ channels. I labeled those cables. |
1291
|
Wed Feb 11 07:28:25 2009 |
Yoichi | Update | PSL | PA current and laser output |
I think we should also plot the laser power at the MOPA output. The horizontal axis should be the absolute current value read from the PA current monitor channel, not the slider value.
This result is consistent with my hypothesis that the thermal effect is canceling the power change at low frequencies (see elog:1276).
But if it is really caused by thermal effect or not is still unknown.
I'd like to see a larger scan into the lower current region.
Quote: | I changed the PA current and measured laser output power (monitor PD signal).
The gain of ISS is 13dB
Attached figure is the relation of PA current and the average and standard diviation of laser output.
The average of output power decreas as current increase. It looks something is wrong with PA.
When current is -0.125, 0, 0.5, ISS become ocsilating. This looks to be changed from previous measurement.
I wrote matlab code for this measurement. The code is
/cvs/cds/caltech/users/kakeru/scripts/CS_evaluate.m
This function uses
/cvs/cds/caltech/users/kakeru/scripts/moveCS.m |
|
1290
|
Wed Feb 11 00:50:24 2009 |
caryn | Update | General | ants? |
So, near 2 of the trashcans in the control room and underneath a desk there are hundrends of ants. Is this normal? |
1289
|
Tue Feb 10 23:36:25 2009 |
Kakeru | Update | PSL | PA current and laser output |
I changed the PA current and measured laser output power (monitor PD signal).
The gain of ISS is 13dB
Attached figure is the relation of PA current and the average and standard diviation of laser output.
The average of output power decreas as current increase. It looks something is wrong with PA.
When current is -0.125, 0, 0.5, ISS become ocsilating. This looks to be changed from previous measurement.
I wrote matlab code for this measurement. The code is
/cvs/cds/caltech/users/kakeru/scripts/CS_evaluate.m
This function uses
/cvs/cds/caltech/users/kakeru/scripts/moveCS.m |
Attachment 1: PA_current_output.png
|
|
1288
|
Tue Feb 10 10:48:48 2009 |
steve | Bureaucracy | SAFETY | safety glasses scanned |
All 40m safety glasses are absorbent.
They were scanned by 180 mW 2mm spot size of 1064 nm beam and their transmissions were measured
They showed no degradation.
UVEX 's LOTG-YAG/CO2 glasses (fits over personal glasses) 11 pieces,
Glendale-XC by Bacou-Dalloz, #1166218VLT68% , aerodynamic style, 7 pieces, (4 missing )
KG5- glasses , heavier- made out of glass, 3 pieces,
Thorlab's LG10, 1 piece
Old glasses by "Laser Glass" Nd-YAG, 2 pieces
Totaling 24
Atm.2 showing our muilty wavelength glasses of 1064 and 530 nm
Their transmittance for both wavelength were zero.
Note: if you have prescripton safety glasses I would like to scan it for you !
|
Attachment 1: sgscan1.png
|
|
Attachment 2: sgscan2.png
|
|
1287
|
Mon Feb 9 19:50:48 2009 |
Yoichi | Configuration | PSL | ISS disconnected |
We are doing measurements on ISS.
The ISS feedback connector is disconnected and the beam to the MC is blocked. |
1286
|
Mon Feb 9 17:09:51 2009 |
Yoichi | Update | Computers | A bunch of updates for the network GPIB stuff. |
During the work on ISS, we noticed that netgpibdata.py is very unreliable for SR785.
The problem was caused by flakiness of the "DUMP" command of SR785, which dumps the data from the analyzer to the client.
So I decided to use other GPIB commands to download data from SR785. The new method is a bit slower but much more reliable.
I also rewrote netgpibdata.py and related modules using a new class "netGPIB".
This class is provided by netgpib.py module in the netgpibdata directory. If you use this class for your python program, all technical details and dirty tricks are hidden in the class methods. So you can concentrate on your job.
Since python can also be used interactively, you can use this class for a quick communication with an GPIB instrument.
Here is an example.
>ipython #start interactive python
>>import netgpib #Import the module
>>g=netgpib.netGPIB('teofila',10) #Create a netGPIB object. 'teofila' is the hostname of
#the GPIB-Ethernet converter. 10 is the GPIB address.
>>g.command('ACTD0') #Send a GPIB command "ACTD0". This is an SR785 command meaning "Change active display to 0".
>>ans=g.query('DFMT?') #If you expect a response from the instrument, use query command.
#For SR785, "DFMT?" will return the current display format (0 for single, 1 for dual).
>>g.close() #Close the connection when you are done.
Sometimes, SR785 gets stuck to a weird state and netgpibdata.py may not work properly. I wrote resetSR785.py command to reset it remotely.
Wait for 30sec after you issue this command before doing anything.
I wrote two utility commands to perform measurements with SR785 automatically.
TFSR785.py commands SR785 to perform a transfer function measurement.
SPSR785.py will execute spectrum measurements.
You can control various parameters (bandwidth, resolution, window, etc) with command-line options.
Run those commands with '-h' for help.
It is recommended to use those commands even when you are in front of the analyzer, because they save various measurement parameters (input coupling, units, average number, etc) into a parameter file along with the measured data. Those parameters are useful but recording them for each measurement by hand is a pain. |
1285
|
Mon Feb 9 16:05:01 2009 |
Yoichi | Update | LSC | DRMI OK |
After the ISS work, I aligned the IFO and confirmed that DRMI locks with good SPOB and AS166 values. |
1284
|
Mon Feb 9 16:02:42 2009 |
Yoichi | Update | PSL | PSL relative intensity noise |
I attached the relative intensity noise of the PSL.
There is no bump around the lower UGF (~1Hz), but at the higher UGF (~30kHz) there is a clear bump.
When the ISS gain slider was moved up to 21dB, the peak got milder, because there is larger phase margin at higher frequencies with the current filter design.
We may want to optimize the filter later. |
Attachment 1: RIN-13dB.png
|
|
Attachment 2: RIN-21dB.png
|
|
1283
|
Fri Feb 6 23:23:48 2009 |
Kakeru, Yoichi | Update | PSL | ISS is fixed |
Yoichi and me found that the transfar function of the current shunt changed with the current of PA.
We changed PA current and fixed the unstability of ISS.
Now, laser power is stabilized finely, with band of about 1 Hz.
Yoich will post the stabilized noise spectrum.
There looks to be some non-linear relation between PA current and the TF of current shunt.
It had changed from the TF which we measured yesterday, so it might change again.
I try to write scripts to sweep PA current and measure the laser power and its rms automatically.
It will be apply for auto-adjustment of PA current.
Attached files are the transfar function of the current shunt with changing PA.
They have difference in lower frequency.
|
Attachment 1: Current_ShuntTF_gain.png
|
|
Attachment 2: Current_ShuntTF_phase.png
|
|
1282
|
Fri Feb 6 16:23:54 2009 |
steve | Update | MOPA | MOPAs of 7 years |
MOPAs and their settings, powers of 7 years in the 40m |
Attachment 1: 7ymopas.jpg
|
|
1281
|
Fri Feb 6 16:20:52 2009 |
Yoichi | Update | PSL | MOPA current slider fixed |
I fixed the broken slider to change the current of the PA.
The problem was that the EPICS database assigned a wrong channel of the DAC to the slider.
I found that the PA current adjustment signal lines are connected to the CH3 &CH4 of VMIC4116 #1. However in the database file (/cvs/cds/caltech/target/c1psl/psl.db), the slider channel (C1:PSL-126MOPA_DCAMP) was assigned to CH2. I fixed the database file and rebooted c1psl. Then the PA current started to follow the slider value.
I moved the slider back and forth by +/-0.3V while the ISS loop was on. I observed that the amount of the low frequency fluctuation of the MOPA power changed with the slider position. At some current levels, the ISS instability problem went away.
Kakeru is now taking open-loop TFs and current shunt responses at different slider settings. |
1280
|
Fri Feb 6 14:49:31 2009 |
steve | Summary | SAFETY | laser inventory |
40M Laser Inventory at Feb 05, 2009
1, Lightwave PA#102 @ 77,910 hrs 1064nm of 2.8W @ 27.65A
NPRO#206 @ 2.4A at PSL enclosure............"Big Boy" is waiting for to be retired but not now.
2, Lightwave NPRO 1064nm of 700mW #415 at AP table.......cavity length measurements of Alberto
3, CrystaLaser IRCL-100-1064S, 1064nmS of 100mW ,sn#IR81132 at east arm cabinet
4, CrystaLaser 1064nm of 180mW # -1274 flq at scattering setup.........flashlight quality
5, RF-PD tester 1064nm of 1.2mW @20mA at SP table
6, Lumix 800-1100nm of 500mW at east arm cabinet
7, JDS-Uniphase 633nmP of 4mW oplev sus laser at 5 places,
plus four spares in east arm cabinet
The same information is posted at the 40M WIKI also
|
1279
|
Fri Feb 6 10:46:40 2009 |
Kakeru | Update | PSL | ISS servo and noise |
I measured the output noise of eache stage of ISS servo, and calcurated the noise ratio between input and
output of each stage.
Generaly, each noise ratio corresponds to their transfar function. This means servo filter works well, not
adding extra noise.
I attache example of them.
For 2nd stage, the noise ratio is smaller than transfar function with a few factor. This is because the
input noise is coverd by analyser's noise and ratio between output and input looks small.
This means the input noise of 2nd stage was enough small and all stage before 2nd stage work well |
Attachment 1: ISS_servo_TF_noise.png
|
|
1278
|
Fri Feb 6 09:56:11 2009 |
Kakeru | Update | PSL | ISS servo transfar function |
I attache the transfar function of ISS servo.
The 4th stage and variable gain amplifier has alomost same transfar function, so their lines pile up. |
Attachment 1: TF_ISSservo_gain.png
|
|
Attachment 2: TF_ISSservo_phase.png
|
|
1277
|
Fri Feb 6 09:52:35 2009 |
Kakeru | Update | PSL | Current shunt transfar function |
I attach the transfar function of the current shunt.
There is a little gap at 10 Hz for phase, but it is a ploblem of measurement and not real one.
|
Attachment 1: TF_CS_gain.png
|
|
Attachment 2: TF_CS_phase.png
|
|
1276
|
Thu Feb 5 21:42:28 2009 |
Yoichi | Update | PSL | My thoughts on ISS |
Today, I worked with Kakeru on ISS.
The problem is sort of elusive. Some time, the laser power looks fine, but after a while you may see many sharp drops in the power. Some times, the power drops happen so often that they look almost like an oscillation.
We made several measurements today and Kakeru is now putting the data together. Meanwhile, I will put my speculations on the ISS problem here.
The other day, Kakeru took the transfer function of the ISS feedback filter (he is supposed to post it soon). The filter shape itself has a large phase margin ( more than 50deg ?) at the lower UGF (~3Hz) if we assume the response of the current shunt to be flat. However, when we took the whole open loop transfer function of the ISS loop, the phase margin was only 20deg. This leads to the amplification of the intensity noise around the UGF. The attached plot is the spectrum of the ISS monitor PD. You can see a broad peak around 2.7Hz. In time series, this amplified intensity noise looks like semi-oscillation around this frequency.
Since it is very unlikely that the PD has a large phase advance at low frequencies, the additional phase advance has to be in the current shunt. We measured the response of the current shunt (see Kakeru's coming post). It had a slight high-pass shape below 100Hz (a few dB/dec). This high-pass response produces additional phase advance in the loop.
There seems to be no element to produce such a high-pass response in the current shunt circuit ( http://www.ligo.caltech.edu/docs/D/D040542-A1.pdf )
This Jamie's document shows a similar high-pass response of the current ( http://www.ligo.caltech.edu/docs/G/G030476-00.pdf page 7 )
Now the question is what causes this high-pass response. Here is my very fishy hypothesis :-)
The PA output depends not only on the pump diode current but also on the mode matching with the NPRO beam, which can be changed by the thermal lensing. If the thermal lensing is in such a condition that an increase in the temperature would reduce the mode matching, then the temperature increase associated with a pump current increase could cancel the power increase. This thermal effect would be bigger at lower frequencies. Therefore, the intensity modulation efficiency decreases at lower frequencies (high-pass behavior). If this model is true, this could explain the elusiveness of the problem, as the cancellation amount depends on the operation point of the PA.
To test this hypothesis, we can change the pump current level to see if the current shunt response changes. However, the PA current slider on the MEDM screen does not work (Rob told me it's been like this for a while). Also the front panel of the MOPA power supply does not work (Steve told me it's been like this for a while). We tried to connect to the MOPA power supply from a PC through RS-232C port, which did not work neither. We will try to fix the MEDM slider tomorrow. |
Attachment 1: INMONPD_Spectrum_1-10Hz.pdf
|
|
1275
|
Thu Feb 5 16:21:07 2009 |
Jenne | Frogs | Computers | Belladonna connects to the wireless Martian network again |
Symptoms: Belladonna could not (for a while) connect to the wireless network, since there was a driver problem for the wireless card. This (I believe) started when Yoichi was doing updates on it a while back.
The system: Belladonna is a Dell Inspirion E1505 laptop, with a Broadcom Corporation Dell Wireless 1390 WLAN Mini-PCI Card (rev 01)
Result: Belladonna now can talk to it's wireless card, and is connected to the Martian network. (MEDM and Dataviewer both work, so it must be on the network.)
What I did:
0. Find a linux forum with the following method: http://www.thelinuxpimp.com/main/index.php?name=News&file=article&sid=749
The person who wrote this has the exact same laptop, with the same wireless card.
1. Get a new(er) version of ndiswrapper, which "translates" the Windows Driver for the wireless card to Linux-ese. Belladonna previously was using ndiswrapper-1.37.
$wget http://nchc.dl.sourceforge.net/sourceforge/ndiswrapper/ndiswrapper-1.42.tar.gz
2. Put the ndiswrapper in /home/controls/Drivers, and installed it.
$ndiswrapper -i bcmwl5.inf 3. Get and put the Windows driver in /home/controls/Drivers/WiFi
$wget http://ftp.us.dell.com/network/R140747.EXE
4. Unzip the driver
$unzip -a R140747.EXE
5. Make Fedora use ndiswrapper
$ndiswrapper -m
$modprobe ndiswrapper
6. Change some files to make everything work:
/etc/sysconfig/wpa_supplicant CHANGE FROM: DRIVERS="-Dndiswrapper" CHANGE TO: DRIVERS="-Dwext"
/etc/sysconfig/network-scripts/ifcfg-wlan0 CHANGE FROM: BOOTPROTO=none CHANGE TO: BOOTPROTO=dhcp
/etc/rc.d/init.d/wpa_supplicant CHANGE FROM: daemon $prog -c $conf $INTERFACES $DRIVERS -B CHANGE TO: daemon $prog -c$conf $INTERFACES $DRIVERS -B
6. Restart things
$service wpa_supplicant restart
$service network restart
7. Restart computer (since it wasn't working after 1-6, so give a restart a try)
8. Success!!! MEDM and Dataviewer work without any wired internet connection => wireless card is all good again!
|
1274
|
Thu Feb 5 10:42:33 2009 |
Yoichi | Update | General | Do we need off-axis parabolic mirrors ? No way ! |
I made a mistake in estimating the astigmatism problem.
If we use the current MMT1 as it is, this one is already an off-axis parabolic (OAP) mirror.
In this case, the astigmatism of this mirror is very small (if we use it with the correct angle). I did not include this effect in the previous calculation.
It turned out that the maximum achievable mode matching becomes far smaller (only 77%) if we use the OAP for MMT1 and a spherical mirror for MMT2.
This is not acceptable.
The reason behind this is that when we use spherical mirrors for both MMT mirrors, the astigmatism caused by the MMT1 is somewhat canceled by the astigmatism of MMT2. We don't get this cancellation if we mix OAP and spherical mirrors.
We should either (1) change MMT1 to a spherical mirror and keep the length of the input MMT as it is, or (2) change MMT1 to a spherical mirror and elongate the length of the input MMT.
In the case of (1) the maximum achievable mode matching is 94%. The focal length of MMT2 should be 315.6mm.
If we do (2), the mode matching rate can be as high as 99.8%. The focal lengths are MMT1 = -301.3mm, MMT2=558mm. The distance between the mirrors is 262mm.
We have enough space to do this elongation. But we have to mechanically modify the MMT mount.
I prefer (2).
As usual, the document on the Wiki was updated to include the above calculations. |
1273
|
Thu Feb 5 09:12:29 2009 |
steve | Bureaucracy | SAFETY | safety updates & fire alarm test |
The fire alarm test was completed at 13:30 yesterday.
I updated the 40M Emergency Calling List by replacing Rob by Yoichy. The calling order: Vass, Aso and Taylor.
Rana and Yoichy were added to the "Registered PSL Operator List" and posted it in the lab. (not in the document, that should be up dated)
We are getting ready for the annual safety audit. It will be held next week at 14:00 Friday, Feb 13, 2009
Please participate in the preparation by correcting it or just tell me.
Rod Luna is organizing the pick up of the following old equipment:
HP laser jet 5000n, 3 of 19" 10 base-T network ports and 4 small hubs,
2 Sun monitors, 1 Viewsonic monitor, 7 keypads and
Hitachi scopes 2 of V-355, 2 of V-422, 1 of V-202 and 1 of V-6165
|
1272
|
Wed Feb 4 19:22:57 2009 |
Yoichi | Update | General | Do we need off-axis parabolic mirrors ? |
I also estimated the mode matching degradation caused by the astigmatism.
Since the incident angles to the mode matching mirrors are not 0, the effective focal lengths in the incident plane and the perpendicular plane are different.
This effect leads to astigmatism of the beam.
When there is astigmatism, the maximum achievable mode matching rate becomes less than 100%.
According to my calculation, the mode matching cannot be better than 94% for the input beam.
For the output mode matching, we can theoretically achieve more than 99% even with the astigmatism.
The difference comes from the fact that the OMMT is longer, thus the incident angle is smaller.
If we don't like this 94%, we have to use off-axis parabolic mirrors, or modify the IMMT to a longer one.
I prefer to make it longer. Just 5" elongation will increase the mode matching rate to 99.4%.
We have a room for this 5" elongation.
Again, the details of the calculation are added to the Mathematica notebook below.
|
1271
|
Wed Feb 4 17:45:39 2009 |
Yoichi | Update | General | Mode matching of the upgraded IFO |
I did mode matching calculations for the new optical layout.
For the input mode matching, we have to change the focal length of the second mirror from 687mm to 315mm and the distance between the two MMT mirrors from 137mm to 149.2mm.
For the mode matching to the OMC, we only have to change the distance between the OMMT mirrors from 384mm to 391mm. No need to change the mirrors.
Details of the calculations can be found in
http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_08/Optical_Layout?action=AttachFile&do=get&target=NewRecyclingCavities.zip
(Mathematica notebook)
or if you prefer PDF, here
http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_08/Optical_Layout?action=AttachFile&do=get&target=NewRecCav.pdf |
1270
|
Tue Feb 3 23:44:44 2009 |
Kakeru, Peter, Yoichi | Update | PSL | ISS unstability |
We found that one OP-amp used in ISS servo oscillated in 10 MHz, 100mV.
Moreover, we found another OP-amp had big noise.
We guess that these oscilation or noise cause saturation in high frequency, and they effect to lower frequency to cause
Attached files are open loop transfar function of ISS.
The blue points are open loop TF, and the green line is product of TF of ISS servo filter and TF of current shunt TF of servo filter.
This two must be same in principle, but They have difference f<2Hz and f>5kHz.
|
Attachment 1: TFgain.png
|
|
Attachment 2: TFphase.png
|
|
1269
|
Tue Feb 3 19:24:14 2009 |
Yoichi | Update | General | New optics layout wiki page |
I uploaded a slightly updated version of the new optics layout on the 40m wiki.
http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_08/Optical_Layout
I also uploaded the Mathematica notebook I used to calculate various parameters of the new recycling cavities, including the lengths, asymmetry, ROCs, PRM reflectivity and TT-mirror loss margin etc.
It would be nice if someone could check if the calculation is reasonable.
There is a PDF version of the document for non-Mathematica users. |
1268
|
Tue Feb 3 15:01:38 2009 |
Alberto | Frogs | Computers | megatron slow? |
I notice that Megatron is slower than any other computer in running code that invokes optickle or looptickle (i.e. three times slower than Ottavia). Even without the graphics.
Has anyone ever experienced that? |
1267
|
Mon Feb 2 19:23:53 2009 |
Yoichi | Update | General | New optical layout plan |
The attached is a plan of the optical layout in the central part for the upgrade.
I included, the folded recycling cavities, oplevs for the core optics, POX, POY, POB and video views.
I have not worked out how to handle the beams outside the chambers. It should not be that difficult.
I also did not include beam dumps for unwanted beams.
I used pink for main beams, brown for picked off beams, red for oplevs.
Comments, suggestions are welcome. |
Attachment 1: 40mUpgradeOpticalLayoutPlan01.pdf.zip
|
1266
|
Mon Feb 2 18:51:02 2009 |
Alberto | Configuration | General | New Elog 2.7.5 in Service on Nodus |
Quote: |
I moved the 40m, the Adhikari Lab and the SUS elogs from Dziban (located in Millikan's 6th floor) to our gateway server Nodus. In this way we should the complete control of it. I also updated the elog manager from the 2.6.5 version to the 2.7.5. Some smoothing of its interface might still be needed these days. We'll be testing it for a while before killing the old one. from now on everybody is invited to use only the new elog address since there will be no record of entries posted in the old one. Let me know of any possible difficulty in having access to it. |
As a reference. The elog runs on background in nodus.
To kill the process:
1) pkill -3 elogd
2) rm -f /var/run/elogd.pid
To restart it:
elogd -p 8080 -c /export/elog/elog-2.7.5/elogd.cfg -D
|
1265
|
Mon Feb 2 18:32:54 2009 |
Alberto | Configuration | General | Some little problem with the new elog |
Quote: |
For some reason the new elog does not look exactly like it should. 1) Some of the editing features are not available. 2) The Reply option opens the HTML of the message by default. I think this is happening because Nodus is a Sun of platform and things are a little bit different from linux. I'm working to fix these things. If I make any change and need to restart the elog, I'll try to be very quick. I apologize for the inconveniences. |
I think I solved the problem (as you can probably see).
The cause was that this WYSIWYG interface for HTML is provided by an independent text editor called FCKeditor which is included in the elog. Although the elog installer has a bug and does not unzip properly the relative package. One has to do it by hand. (going to /elog/scripts/ and unzipping fckeditor.zip by hand in the same directory). |
1264
|
Mon Feb 2 17:25:44 2009 |
Alberto | Configuration | General | Some little problem with the new elog |
For some reason the new elog does not look exactly like it should.
1) Some of the editing features are not available.
2) The Reply option opens the HTML of the message by default.
I think this is happening because Nodus is a Sun of platform and things are a little bit different from linux.
I'm working to fix these things. If I make any change and need to restart the elog, I'll try to be very quick.
I apologize for the inconveniences. |