varun | Update | CDS | DAFI update: stereo output |
I wish to have stereo audio output for the DAF module. Hence, there needs to be a second output from the DAF. I added this second output to the model. Following are the details:
FiBox: It consists of two analog inputs which are digitized and multiplexed and transmitted optically. (only 1 fiber is needed due to multiplexing). Attachment 1 shows the fibox with its 2 analog inputs (one of which, is connected), and 1 fiber output. The output of the DAF goes to the FiBox. Until today, the Fibox recieved only 1 analog input. This analog signal comes from the DAC-8 (count starting from 0), which is located at "CH 1 OUT" SMA output in the "MONITORS" bin on the racks (attachment 2).
I have added another output channel to the DAF model both in software and in hardware. The DAF now also uses DAC-9 analog output which goes to the second analog input of the FiBox. The DAC-9 output is located at "CH 2 OUT" SMA output in the "MONITORS" bin on the racks (attachment 4).
After making the changes, the Fibox is shown in attacment 3.
Testing: The LSC input on passing through the DAF block is given through two different DAC outputs, to the same Fibox channel (one after the other), and the output is heard. More concrete testing will be done tomorrow. It will be as follows:
1) Currently, I need to search for a suitable cable that would connect the second channel of the output fibox to the audio mixer. After doing this, end to end testing of both channels will be done.
2) I could not access the AWG, probably because the DAQ was offline today afternoon. Using a signal from the AWG will give a more concrete testing of the stereo output.
3) After this, I will separate the two channels of the stereo completely (currectly they are seperated only at the DAF output stage)
4) I also will edit the medm gui appropriately.
Quote: |
I have added Enable buttons for each of the DSP blocks, and labels for the matrix elements. The input matrix takes inputs from each of the 4 channels: ADC1, ADC2, LSC and EXC, and routes them to the audio processing blocks (attachment 2). The output matrix (attachment 3) takes the outputs of the various DSP blocks and routes them to the output and then to the speakers.
|
|
Attachment 1: IMG_20160615_145535907.jpg
|
|
Attachment 2: IMG_20160615_145413005_HDR.jpg
|
|
Attachment 3: IMG_20160616_101229499.jpg
|
|
Attachment 4: IMG_20160616_101157096.jpg
|
|
12191
|
Thu Jun 16 16:11:11 2016 |
jamie | Update | CDS | upgrade aborted for now |
After poking at the new configuration more, it also started to show instability. I couldn't figure out how to make test points or excitations available in this configuration, and adding in the full set of test point channels, and trying to do simple things like plotting channels with dtt, the frame writer (fw) would fall over, apparetnly unable to keep up with the broadcast from the dc.
I've revered everything back to the old semi-working fb configuration, and will be kicking this to the CDS group to deal with. |
12200
|
Mon Jun 20 11:11:20 2016 |
Steve | Configuration | CDS | GPS receiver not resetting properly |
I called https://www.endruntechnologies.com/pdf/USM3014-0000-000.pdf and they said it's very likely just needs a software update. They will email Jamie the details.
Quote: |
The GPS receiver (EndRun Technologies box in 1Y5? (rack closest to door)) seems to not coming back up properly after the reboot. The front pannel says that it's "LKD", but the "sync" LED is flashing instead of solid, and the time of year displayed on the front panel is showing day 6. The fb1 symmetricom driver and VME timing module are still both seeing day 299, though. So something may definitely be screwy with the GPS receiver.
|
|
12201
|
Mon Jun 20 11:19:41 2016 |
jamie | Configuration | CDS | GPS receiver not resetting properly |
I got the email from them. There was apparently a bug that manifested on February 14 2016. I'll try to software update today.
http://endruntechnologies.com/pdf/FSB160218.pdf
http://endruntechnologies.com/upgradetemplx.htm |
12202
|
Mon Jun 20 14:03:04 2016 |
jamie | Configuration | CDS | EndRun GPS receiver upgraded, fixed |
I just upgraded the EndRun Technologies Tempus LX GPS receiver timing unit, and it seems to have fixed all the problems. 
Thanks to Steve for getting the info from EndRun. There was indeed a bug in the firmware that was fixed with a firmware upgrade.
I upgraded both the system firmware and the firmware of the GPS subsystem:
Tempus LX GPS(root@Tempus:~)-> gntpversion
Tempus LX GPS 6010-0044-000 v 5.70 - Wed Oct 1 04:28:34 UTC 2014
Tempus LX GPS(root@Tempus:~)-> gpsversion
F/W 5.10 FPGA 0416
Tempus LX GPS(root@Tempus:~)->
After reboot the system is fully functional, displaying the correct time, and outputting the correct IRIG-B data, as confirmed by the VME timing unit.
I added a wiki page for the unit: https://wiki-40m.ligo.caltech.edu/NTP
Steve added this picture |
Attachment 1: GPSreceiverWorking.jpg
|
|
12207
|
Tue Jun 21 11:26:42 2016 |
varun | Frogs | CDS | medm command not working |
"medm: command not found" error when run through command line both in pianosa and rossa in both editing and execution modes. It however gets executed and edited through the sitemap button. Don't know the source of the problem. Gautam did check the .bashrc file. aliases for SITEMAP and m40m are intact in the .bashrc file. |
12208
|
Tue Jun 21 11:49:29 2016 |
ericq | Frogs | CDS | medm command not working |
The workstations' .bashrc is a symbolic link to /users/controls/.bashrc
In it, someone commented out the critical line:
#source /ligo/cdscfg/workstationrc.sh
I uncommented it. medm (and all of the other things like cdsutils) work again.
I blame jamie. |
12211
|
Wed Jun 22 10:15:45 2016 |
varun | Update | CDS | DAFI update: stereo output |
I have updated the DAFI with the following changes:
1) Separated both the channels of stereo output completely, as well as in the GUI.
2) Added text monitors for the inputs and outputs.
The stereo output is now ready except for a cable going from the second channel of the output fibox to the audio mixer.
Attached is the main DAF_OVERVIEW screen and its link button from the LSC screen labelled "DAFI"
Quote: |
I wish to have stereo audio output for the DAF module. Hence, there needs to be a second output from the DAF. I added this second output to the model. Following are the details:
FiBox: It consists of two analog inputs which are digitized and multiplexed and transmitted optically. (only 1 fiber is needed due to multiplexing). Attachment 1 shows the fibox with its 2 analog inputs (one of which, is connected), and 1 fiber output. The output of the DAF goes to the FiBox. Until today, the Fibox recieved only 1 analog input. This analog signal comes from the DAC-8 (count starting from 0), which is located at "CH 1 OUT" SMA output in the "MONITORS" bin on the racks (attachment 2).
I have added another output channel to the DAF model both in software and in hardware. The DAF now also uses DAC-9 analog output which goes to the second analog input of the FiBox. The DAC-9 output is located at "CH 2 OUT" SMA output in the "MONITORS" bin on the racks (attachment 4).
After making the changes, the Fibox is shown in attacment 3.
Testing: The LSC input on passing through the DAF block is given through two different DAC outputs, to the same Fibox channel (one after the other), and the output is heard. More concrete testing will be done tomorrow. It will be as follows:
1) Currently, I need to search for a suitable cable that would connect the second channel of the output fibox to the audio mixer. After doing this, end to end testing of both channels will be done.
2) I could not access the AWG, probably because the DAQ was offline today afternoon. Using a signal from the AWG will give a more concrete testing of the stereo output.
3) After this, I will separate the two channels of the stereo completely (currectly they are seperated only at the DAF output stage)
4) I also will edit the medm gui appropriately.
Quote: |
I have added Enable buttons for each of the DSP blocks, and labels for the matrix elements. The input matrix takes inputs from each of the 4 channels: ADC1, ADC2, LSC and EXC, and routes them to the audio processing blocks (attachment 2). The output matrix (attachment 3) takes the outputs of the various DSP blocks and routes them to the output and then to the speakers.
|
|
|
Attachment 1: C1DAF_OVERVIEW.png
|
|
Attachment 2: DAF_link_from_LSC.png
|
|
12215
|
Mon Jun 27 15:12:09 2016 |
varun | Update | CDS | DAFI update: stereo output |
Using an RC to BNC connector from the inner drawer, I have added a second output cable going from the output Fibox in the control room to the audio mixer.
Quote: |
I have updated the DAFI with the following changes:
1) Separated both the channels of stereo output completely, as well as in the GUI.
2) Added text monitors for the inputs and outputs.
The stereo output is now ready except for a cable going from the second channel of the output fibox to the audio mixer.
Attached is the main DAF_OVERVIEW screen and its link button from the LSC screen labelled "DAFI"
Quote: |
I wish to have stereo audio output for the DAF module. Hence, there needs to be a second output from the DAF. I added this second output to the model. Following are the details:
FiBox: It consists of two analog inputs which are digitized and multiplexed and transmitted optically. (only 1 fiber is needed due to multiplexing). Attachment 1 shows the fibox with its 2 analog inputs (one of which, is connected), and 1 fiber output. The output of the DAF goes to the FiBox. Until today, the Fibox recieved only 1 analog input. This analog signal comes from the DAC-8 (count starting from 0), which is located at "CH 1 OUT" SMA output in the "MONITORS" bin on the racks (attachment 2).
I have added another output channel to the DAF model both in software and in hardware. The DAF now also uses DAC-9 analog output which goes to the second analog input of the FiBox. The DAC-9 output is located at "CH 2 OUT" SMA output in the "MONITORS" bin on the racks (attachment 4).
After making the changes, the Fibox is shown in attacment 3.
Testing: The LSC input on passing through the DAF block is given through two different DAC outputs, to the same Fibox channel (one after the other), and the output is heard. More concrete testing will be done tomorrow. It will be as follows:
1) Currently, I need to search for a suitable cable that would connect the second channel of the output fibox to the audio mixer. After doing this, end to end testing of both channels will be done.
2) I could not access the AWG, probably because the DAQ was offline today afternoon. Using a signal from the AWG will give a more concrete testing of the stereo output.
3) After this, I will separate the two channels of the stereo completely (currectly they are seperated only at the DAF output stage)
4) I also will edit the medm gui appropriately.
Quote: |
I have added Enable buttons for each of the DSP blocks, and labels for the matrix elements. The input matrix takes inputs from each of the 4 channels: ADC1, ADC2, LSC and EXC, and routes them to the audio processing blocks (attachment 2). The output matrix (attachment 3) takes the outputs of the various DSP blocks and routes them to the output and then to the speakers.
|
|
|
|
Attachment 1: IMG_20160627_151753247.jpg
|
|
12251
|
Wed Jul 6 10:58:29 2016 |
Varun | Update | CDS | DAFI review |
The DAFI block was reviewed by Rana yesterday. The following changes/improvements were suggested: (Updated on 20th July 2016 with tasks taat remain in red)
1) include all the various channels like PEM, LSC, ASC, SUS, SEI, etc. as the inputs. Currently the inputs are only the LSC.
2) include all the control signals.
3) create a very detailed diagram of the entire signal flow and plan tasks accordingly.
4) Enable cascading of various DSP processes.
5) Adjusting the gain of the AGC such that the amplitude of the output signal comes to about half the peak amplitude offered by the ADC. This will help taking advantage of the entire dynamic range of the ADC.
6) change the enable button styles from a text input based controller to a button controller.
7) Currently, disabling a particular signal terminates the signal. Instead, it should turn into a unity gain block on disabling.
8) Check if the Fibox does AC coupling or not. If not, add an AC coupling arrangement in the DAFI.
9) Check the nature of the ADC1 and ADC2 inputs to the DAFI. I checked them yesterday, and they are channels 25 and 26 of ADC0, which are empty. |
12266
|
Thu Jul 7 12:44:52 2016 |
varun | Update | CDS | DAFI update |
Attached is a diagram, showing the entire (planned) signal flow of the DAF model. Some thoughts on the implementation after discussion with eric:
1) Since the LSC control signals and ASC signals are running on the c1lsc FE at the same rate as DAFI (16kHz), it would be wise to start from these.
Current implementation: has a matrix at the end of the LSC PD signals, which selects one of the PD signals and outputs it to the DAFI via IPC communication.
Proposed Changes: Add another matrix at the end of the LSC PD signals, to give to the second stereo output. Similarly, add two matrices each at the end of the LSC control signals and the ASC signals. Each matrix must select one of the signals and output it to the DAF via IPC.
2) The PEM running on the c1sus FE system will have to be brought to DAFI in a similar fashon. However, since c1sus runs at 2kHz, there is a possibility of imaging while the signal is transfered to the DAFI. This could be taken care of by an anti imaging filter, or inserting zeros between two samples coming at to the 16 kHz system from the 2kHz system and then low-passing it to remove the aliased parts. (similar to upsampling)
3) For the SUS control signals, input can be given from a matrix prepared for each optic seperately. |
Attachment 1: DAFI.pdf
|
|
12282
|
Fri Jul 8 22:26:03 2016 |
varun | Update | CDS | DAFI Update: Changes in LSC model |
I have added the control signals DARM_CTRL, MICH_CTRL, PRCL_CTRL, SRCL_CTRL, CARM_CTRL, XARM_CTRL, YARM_CTRL, MC_CTRL to the DAFI model from the LSC model via IPC commn.
The changes done to the LSC model include addition of an extra block going to DAFI (attachment 2, red rectangle in attachment 1), and addition of an extra overall output from the LSC, called DAFI_OUT2, which goes to DAFI through IPC link C1:LSC-DAF_2 (attach. 3). Now two distinct inputs can be given to the DAFI, whose intended purpose is to act as two distinct audio signals in the stereo output, but can also be used for arbitrary math.
I am going to add the following PEM channels as DAF inputs subsequently, in a similar 2 input fashon.
SEIS_GUR1_X_OUT
SEIS_GUR1_Y_OUT
SEIS_GUR1_Z_OUT
SEIS_GUR2_X_OUT
SEIS_GUR2_Y_OUT
SEIS_GUR2_Z_OUT
SEIS_STS_1_X_OUT
SEIS_STS_1_Y_OUT
SEIS_STS_1_Z_OUT
ACC_MC1_X_OUT
ACC_MC1_Y_OUT
ACC_MC1_Z_OUT
ACC_MC2_X_OUT
ACC_MC2_Y_OUT
ACC_MC2_Z_OUT
|
Attachment 1: lsc.png
|
|
Attachment 2: lsctodaf.png
|
|
Attachment 3: lsctodaf1.png
|
|
12284
|
Sun Jul 10 15:54:23 2016 |
ericq | Update | CDS | All models restarted |
For some reason, all of the non-IOP models on the vertex frontends had crashed.
To get all of the bits green, I ended up restarting all models on all frontends. (This means Gautam's coil tests have been interrupted.) |
12287
|
Sun Jul 10 20:08:44 2016 |
varun | Update | CDS | DAFI Update: Changes in LSC and PEM models |
I have added the PEM signals mentioned in the previous elog as DAF inputs through PCIE IPC, and compiled and restarted the c1pem and c1daf models.
Attached are the pictures of the simulink diagram of the addition in the PEM and the DAF.
Since the signals are moving from a 2kHz clock rate machine to a 16kHz clock rate machine, some imaging effects are possible, which I have to look into. |
Attachment 1: pemtodaf.png
|
|
Attachment 2: pemindaf.png
|
|
12303
|
Thu Jul 14 23:38:59 2016 |
varun | Update | CDS | c1lsc FE unresponsive |
Today, at around 10:30, c1lsc machine froze and stopped responding to ping and ssh after I compiled and restarted c1daf. I think it is due to a large array in one of my codes. The daqd.log file shows the following:
..................................................................
CA.Client.Exception...............................................
Warning: "Virtual circuit unresponsive"
Context: "c1lsc.martian.113.168.192.in-addr.arpa:5064"
Source File: ../tcpiiu.cpp line 945
Current Time: Thu Jul 14 2016 22:27:42.102649102
..................................................................
I think the c1lsc FE may need a hard reboot. |
12304
|
Fri Jul 15 12:21:28 2016 |
varun | Update | CDS | c1lsc FE unresponsive |
c1lsc is up and running, Eric did a manual reboot today.
Quote: |
Today, at around 10:30, c1lsc machine froze and stopped responding to ping and ssh after I compiled and restarted c1daf. I think it is due to a large array in one of my codes. The daqd.log file shows the following:
..................................................................
CA.Client.Exception...............................................
Warning: "Virtual circuit unresponsive"
Context: "c1lsc.martian.113.168.192.in-addr.arpa:5064"
Source File: ../tcpiiu.cpp line 945
Current Time: Thu Jul 14 2016 22:27:42.102649102
..................................................................
I think the c1lsc FE may need a hard reboot.
|
|
12307
|
Sat Jul 16 00:30:42 2016 |
varun | Update | CDS | DAFI update: Frequency warping | c1lsc unresponsive |
Summary: I am trying to implement frequency warping/pitch shifting on the real time FE. Here is a description long overdue:
Description: The overall idea is as follows:
The DFT of a frame is given by . A matrix W containing all for k, n = 1, 2, ..., m can be calculated and predefined in the code. The input arrival rate is 16384 Hz, i.e. once in every 60 $\mu$s time window. Hence, the fourier coefficients can be updated cumulatively in each cycle using the current value of the input, previous value of the fourier coefficient and the components of the W matrix. This will distribute the computational load of the FFT into all the time windows. Similar operations can be carried out for the inverse STFT.
I have written and run a pseudo-real time code on my CPU. The following is the essence:
Let the frame-length be M, and the intended scale factor of the frequency warping be 'r'. The frame overlap is 50%. At each clock cycle, the following tasks are performed: (1 to 3 are routine tasks performed at every clock cycle, 4 is a special task performed only when a frame is filled.)
1) Take input and apply hanning window to it.
2) Cumulate for every k using the value of x_i[n] (the input) at that particular instant. Also start to cumulate X_{i+1}[k], which will be later transfered to X_i[k].
3) Because of 4), we now have 'r+1' filled frames corresponding to output fft. Now take the ifft using two consecutive frames corresponding to only two time series points. The computations required for this task are the same as the computations required for calculation of the fourier coefficients iteratively, since the entire time series ifft is not computed.
4) Do these special tasks after each frame gets filled:
At this point, the ffts of the current frame and a previous frame is ready. Let us call them X1 and X2.
Calculate phase difference between the two.
Calculate all the interpolated |Y_i| in between these two frames depending upon the scale factor.
Assign phase of X1 to first Y frame and assign increasing phase to all the other Y frames.
and also do all the usual non-special tasks.
This code takes about 9-10 microseconds for a cycle with special tasks, and 5-6 microseconds for a cycle with routine tasks on my laptop (brought down from 100 microseconds peak time in the earlier offline implementation due to elemination of explicit dft and reduction in fft size), for a frame size of 32 samples. However, when fed into the c1lsc FE, it crashes, as it has done once again today evening, in the same fashon as yesterday. There could be 2 possible reasons:
1) Size of the array containing the matrix elements is too large for the FE memory,
2) the computations are taking up more than 60 microseconds.
Since there are already a few codes with similar array sizes, I am more inclined to think that 2) is more likely.
Another problem that I am anticipating is that for a 32 point dft and a sampling rate of 16kHz, the frequency resolution achieved is about 500 Hz, which is not sufficient if we need to represent seismic signals. The only way I can think of, for representing such signals with a small number of fft points, is to reduce the effective sampling rate, i.e. do DSP on inputs at a much lower rate than 16kHz (say 1kHz, which will give a resolution of ~30 Hz, or 2kHz giving a resolution of ~60Hz). Another advantage of this method is that it frees up more clock cycles for computation, thus the computational load can be further distributed. The problem in this implementation is that it will increase the delays. |
12309
|
Mon Jul 18 18:44:52 2016 |
varun | Update | CDS | c1lsc FE recovered |
c1lsc FE is up and running.
Details:
2) The machine was manually rebooted.
3) c1daf was recompiled and installed, with the problematic piece of code removed.
4) NTP timing was adjusted.
5) Frame Builder was restarted.
6) All models on c1lsc machine were restarted.
Attachment 1 shows the CDS status after the recovery. I wont be trying to run frequency warping immediately, I will first finish implementing the other harmless modules first. |
Attachment 1: CDS_status160718.png
|
|
12319
|
Thu Jul 21 12:03:35 2016 |
varun | Update | CDS | DAFI update: Humming noise in DAFI output |
Summary: There was always a constant humming noise in the output of speakers of both the audio channels. Tried to resolve the problem. Details are given below:
Details: The source of the noise was the typical 60 Hz (and harmonics), ~13 mV peak to peak output, in at least three channels of the DAC. (two coming from the DAF module, and one not related to the DAF.) Attachment 1 shows the noise in both the DAF channels. As compared to that, the signal coming through the AGC weak, about 6 mV RMS, about the same order as noise. In order to resolve this, the gain of the AGC was increased, so that the RMS output voltage of the Fibox (FBAO, the one at the output) was about 1.23 V RMS. It is approximately equal to +4 dBu, which is the typical expected output of the Fibox, according to the datasheet.
|
Attachment 1: New_Doc_13.pdf
|
|
12320
|
Thu Jul 21 14:27:24 2016 |
varun | Update | CDS | DAFI Update: Arbitrary Math block |
Summary: I have added an arbitrary math block to the DAFI model, which takes two inputs, say X and Y, and can perform various unary and binary operations on them:
Details:
- Delay - There exists a text-based input to specify the amount of delay to be given to a particular signal.
- sin()
- cos()
- Weighted addition and multiplication: The output is calculated according to the relation: A*X + B*Y + C*X*Y. A, B, C are constant inputs, which can be given through text-based inputs in the GUI.
- MAX{X,Y}
- MIN{X,Y}
Attachment 1 shows the existing DAFI gui, updated with cascading of various DSP blocks, upto three levels, button-based ENABLE and DISABLE controls for all blocks except arb. math (the control on arb. math. is achieved by clicking on the block.) On clicking the arb. math block one is taken to the dedicated arb. math screen, which has enable buttons for all the processes listed above. A screenshot of this screen is in attachment 2. There is one control input, which controls all the unary operations on X and the binary operations on X and Y, and another control input which controls the unary operations on Y. switching on a particular arb. math process gives a particular control input, which choses the appropriate section of the code. At a time, only one process from the top grey block (corresponding to unary operations on X and binary operations on X and Y) and one process from the bottom grey block (corresponding to unary operations on Y) can be selected. Thus, the outputs which go from the arb. math block to the intermediate matrices (MATRIX1L or MATRIX2L) are:
a) Either an output of unary operation on X or a binary operation on X and Y, the specific one depending upon the control input,
and
b) Output of a unary operation on Y, again the specific one depending upon the control input
Thus there is apparent asymmetricity in the action of the arb. math block on the two inputs. However, this is done in order to reduce to total number of outputs and control signals, and this can be easily taken care of by interchanging the inputs before the block.
While compiling this code, the c1lsc machine had crashed once, it was found that this was due to a stray "printf()" command in the c code. This glich in the code now stands rectified There is a possibility that the previous incidents of the code crashing could also be due to the existence of a printf() command.
Preliminary Testing: I have done a preliminary testing of the arb math block, i.e. verified that on enabling the sin and cos processes, the output is less that 1, on swithching on the process of weighted avarage and multiplication, the output looks like it is right, for a few simple values of A, B, C, like 0, 1, etc. The delay block however is giving zero output for delay of more than 6 samples.
|
Attachment 1: dafioverview.png
|
|
Attachment 2: arbmath.png
|
|
12321
|
Thu Jul 21 15:03:13 2016 |
varun | Update | CDS | DAFI Update |
1) I have added the status summary of the DAFI block to the main FE status overview screen in the c1lsc cloumn. (attachment 1)
2) I have edited all the kissel matrix buttons appropriately, and given them appropriate lables. (attachment 2) |
Attachment 1: festatus.png
|
|
Attachment 2: matrices.png
|
|
12324
|
Thu Jul 21 22:02:35 2016 |
varun | Update | CDS | DAFI update: Frequency warping |
The code for frequency warping contained a "printf()" command, which had caused the system to crash in one another instance (refer elog 12320) . Hence, I tried running the code tody by removing this line. Unfortunately, this did not work. the model still crashed. Attached is the screenshot of the FE status. |
Attachment 1: 07212016.png
|
|
12336
|
Tue Jul 26 09:56:34 2016 |
ericq | Update | CDS | c1susaux restarted |
c1susaux (which controls watchdogs and alignments for all non-ETM optics) was down, the last BURT was done yesterday around 2PM.
I restarted via keying the crate. I restored the BURT snapshot from yesterday. |
12361
|
Mon Aug 1 20:09:37 2016 |
rana | Update | CDS | DAFI Update |
I found the DAFI screen as a button inside of the LSC screen - I think its more logically found from the sitemap, so I'll move it into there as well.
Quote: |
1) I have added the status summary of the DAFI block to the main FE status overview screen in the c1lsc cloumn. (attachment 1)
2) I have edited all the kissel matrix buttons appropriately, and given them appropriate lables. (attachment 2)
|
Gautam and I noticed a 60 Hz + harmonics hum which comes from the DAFI. Its the noisiest thing in the control room. It goes away when we unplug the fiber coming into the control room FiBox receiver, so its not a ground loop on this end. Probably a ground loop at the LSC rack.
Upon further investigation we notice that the Fibox at the LSC rack had its gain turned all the way up to +70 dB. This seemed too much, we reduced it to ~20 (?) so that we could use more of the DAC range. Also, it is powered by a AC/DC converter plugged in to the LSC rack power strip. We cannot use this for a permanent install - must power the FiBox using the same power supplies as are used for the LSC electronics. Probably we'll have to make a little box that takes the fused rack power of 15 V and turns it into +12 V with a regulator (max current of 0.15 A). Making sure that the FiBox doesn't pollute the rest of the LSC stuff with its nasty internal DC-DC converters.
We also put a high pass in the output filter banks of DAFI. For the PEM channels we put in a 60 Hz comb. WE then routed the Y-end Guralp in through the boxes and out the output, mostly bypassing the frequency shifting and AGC. It seems that there is still a problem with GUR2.
Does anyone know which one is GUR1 and which one is GUR2? I don't remember the result of the Guralp cable switching adventures - maybe Koji or Steve does. According to the trend it was totally dead before March and in March it became alive enough for us to see ~30 ADC counts of action, so way smaller than GUR111 or GUR snoopy or whatever its called. |
12539
|
Fri Oct 7 20:25:14 2016 |
Koji | Update | CDS | Power-cycled c1psl and c1iool0 |
Found the MC autolocker kept failing, It turned out that c1iool0 and c1psl went bad and did not accept the epics commands.
Went to the rack and power cycled them. Burt resotred with the snapshot files at 5:07 today.
The PMC lock was restored, IMC was locked, WFS turned on, and WFS output offloaded to the bias sliders.
The PMC seemed highly misaligned, but I didn't bother myself to touch it this time. |
12542
|
Mon Oct 10 11:48:05 2016 |
gautam | Update | CDS | Power-cycled c1susaux, realigned PMC, spots centered on WFS1 and WFS2 |
[Koji, Gautam]
We did the following today morning:
- I re-aligned the PMC - transmission level on the scope on the PSL table is now ~0.72V which is around what I remember it being
- The spot had fallen off WFS 2 - so we froze the output of the MC WFS servo, and turned the servo off. Then we went to the table to re-center the spot on the WFS. The alignment had drifted quite a bit on WFS2, and so we had to change the scale on the grid on the MEDM screen to +/-10 (from +/- 1) to find the spot and re-center it using the steering mirror immediately before the WFS. It would appear that the dark offsets are different on WFS1 and WFS2, so the "SUM" reads ~2.5 on WFS1 and ~0.3 on WFS2 when the spots are well centered
- Coming back to the control room, we ran the WFSoffsets script and turned on the WFS servo again. Trying to run the relief servo, we were confronted by an error message that c1susaux needed to be power cycled (again). This is of course the slow machine that the ITMX suspension is controlled by, and in the past, power cycling c1susaux has resulted in the optic getting stuck. An approach that seems to work (without getting ITMX stuck) is to do the following:
- Save the alignment of the optic, turn off Oplev servo
- Move the bias sliders on IFO align to (0,0) slowly
- Turn the watchdog for ITMX off
- Unplug the cables running from the satellite box to the vacuum feedthrough
- Power cycle the slow machine. Be aware that when the machine comes back on, the offset sliders are reset to the value in the saved file! So before plugging the cables back in, it would be advisable to set these to (0,0) again, to avoid kicking the optic while plugging the cables back in
- Plug in the cables, restore alignment and Oplev servos, check that the optic isn't stuck
- Y green beat touch up - I tweaked the alignment of the first mirror steering the PSL green (after the beam splitter to divide PSL green for X and Y beats) to maximize the beat amplitude on a fast scope. Doing so increased the beat amplitude on the scope from about 20mVpp to ~35mVpp. A detailed power budget for the green beats is yet to be done
It is unfortunate we have to do this dance each time c1susaux has to be restarted, but I guess it is preferable to repeated unsticking of the optic, which presumably applies considerable shear force on the magnets...
After Wednesday's locking effort, Eric had set the IFO to the PRMI configuration, so that we could collect some training data for the PRC angular feedforward filters and see if the filter has changed since it was last updated. We should have plenty of usable data, so I have restored the arms now. |
12592
|
Wed Nov 2 22:56:45 2016 |
gautam | Update | CDS | c1pem revamped |
installing the BLRMS 2k blocks turned out to be quite non-trivial due to a whole host of CDS issues that had to be debugged, but i've restored everything to a good state now, and the channels are being logged. detailed entry with all the changes to follow. |
12595
|
Thu Nov 3 12:38:42 2016 |
gautam | Update | CDS | c1pem revamped |
A number of changes were made to C1PEM and some library parts. Recall that the motivation was to add BLRMS channels for all our suspension coils and shadow sensor PDs, which we are first testing out on the IMC mirrors.
Here is the summary:
BLRMS_2k library block
- The name of the custom C code block in this library part was named 'BLRMSFILTER' which conflicted with the name of the function call in the C code it is linked to, which lead to compilation errors
- Even though the part was found in /opt/rtcds/userapps/release/cds/c1/models and not in the common repository, just to be safe, I made a copy of the part called BLRMS_2k_40m which lives in the above directory. I also made a copy of the code it calls in /opt/rtcds/userapps/release/cds/c1/src
C1PEM model + filter channels
- Adding the updated BLRMS_2k_40m library part still resulted in some compilation errors - specifically, it was telling me to check for missing links around the ADC parts
- Eric suggested that the error messages might not be faithfully reporting what the problem is - true enough, the problem lay in the fact that c1pem wasn't updated to follow the namespace convention that we now use in all the RT models - the compiler was getting confused by the fact that the BLRMS stuff was in a namespace block called 'SUS', but the rest of the PEM stuff wasn't in such a block
- I revamped c1pem to add namespace blocks called PEM and DAF, and put the appropriate stuff in the blocks, after which there were no more compilation errors
- However, this namespace convention messed up the names of the filter modules and associated channels - this was resolved with Eric's help (find and replace did the job, this is a familiar problem that we had encountered not too long ago when C1IOO was similarly revamped...)
- There was one last twist in that the model would compile and install, but just would not start. I tried the usual voodo of restarting all the models, and even did a soft reboot of c1sus, to no avail. Looking at dmesg, I tracked the problem down to a burt restore issue - the solution was to press the little 'BURT' button next to c1pem on the CDS overview MEDM screen as soon as it appeared while restarting the model
All the channels seem to exist, and FB seems to not be overloaded judging by the performance overnight up till the power outage. I will continue to monitor this...
GV Edit 3 Nov 2016 7pm:
I had meant to check the suitability of the filters used - there is a detailed account of the filters implemented in BLRMSFILTER.c here, and I quickly looked at the file on hand to make sure the BP filters made sense (see Attachment #1). These the BP filters are 8th order elliptical filters and the lowpass filters are16th order elliptical filters scaled for the appropriate frequency band, which are somewhat different from what we use on the seismometer BLRMS channels, where the filters are order 4, but I don't think we are significantly overloaded on the computational aspect, and the lowpass filters have sufficiently steep roll-off, these should be okay... |
Attachment 1: BLRMSresp.pdf
|
|
12597
|
Thu Nov 3 13:36:16 2016 |
ericq | Update | CDS | c1pem revamped |
It seems that the EX and EY BLRMS banks were missing the BP and LP filters for the 0.03-0.1 and 0.1-0.3 bands. I've copied over the filters from the BS seismometer.
However, if it looks like the integrated C code BLRMS block works out well, we could replace the seismometers' filter module heavy BLRMS blocks and cut down on the PEM model bloat. |
12599
|
Fri Nov 4 18:31:05 2016 |
Lydia | Update | CDS | c1auxex channels/pins for Acromag |
Here are the channels we are planning to switch over from c1auxex to Acromag, and their current pin numbers on the existing VME boards.
Analog inputs:
C1:SUS-ETMX_UL_AIOut #C0 S0
C1:SUS-ETMX_LL_AIOut #C0 S1
C1:SUS-ETMX_UR_AIOut #C0 S2
C1:SUS-ETMX_LR_AIOut #C0 S3
C1:SUS-ETMX_Side_AIOut #C0 S4
C1:SUS-ETMX_OL_SEG1 #C0 S5
C1:SUS-ETMX_OL_SEG2 #C0 S6
C1:SUS-ETMX_OL_SEG3 #C0 S7
C1:SUS-ETMX_OL_SEG4 #C0 S8
C1:SUS-ETMX_OL_X #C0 S9
C1:SUS-ETMX_OL_Y #C0 S10
C1:SUS-ETMX_OL_S #C0 S11
C1:SUS-ETMX_ULPD #C0 S12
C1:SUS-ETMX_LLPD #C0 S13
C1:SUS-ETMX_URPD #C0 S14
C1:SUS-ETMX_LRPD #C0 S15
C1:SUS-ETMX_SPD #C0 S16
C1:SUS-ETMX_ULV #C0 S17
C1:SUS-ETMX_LLV #C0 S18
C1:SUS-ETMX_URV #C0 S19
C1:SUS-ETMX_LRV #C0 S20
C1:SUS-ETMX_SideV #C0 S21
C1:SUS-ETMX_ULPD_MEAN #C0 S12
C1:SUS-ETMX_LLPD_MEAN #C0 S13
C1:SUS-ETMX_SDPD_MEAN #C0 S16
Analog Outputs:
C1:ASC-QPDX_S1WhiteGain #C0 S0
C1:ASC-QPDX_S2WhiteGain #C0 S1
C1:ASC-QPDX_S3WhiteGain #C0 S2
C1:ASC-QPDX_S4WhiteGain #C0 S3
C1:SUS-ETMX_ULBiasAdj #C0 S4
C1:SUS-ETMX_LLBiasAdj #C0 S5
C1:SUS-ETMX_URBiasAdj #C0 S6
C1:SUS-ETMX_LRBiasAdj #C0 S7
C1:LSC-EX_GREENLASER_TEMP #C0 S0 This appears to have the same pin as another channel-- is it not being used?
Binary Outputs:
C1:SUS-ETMX_UL_ENABLE #C0 S0
C1:SUS-ETMX_LL_ENABLE #C0 S1
C1:SUS-ETMX_UR_ENABLE #C0 S2
C1:SUS-ETMX_LR_ENABLE #C0 S3
C1:SUS-ETMX_SD_ENABLE #C0 S4
C1:ASC-QPDX_GainSwitch1 #C0 S7
C1:ASC-QPDX_GainSwitch2 #C0 S8
C1:ASC-QPDX_GainSwitch3 #C0 S9
C1:ASC-QPDX_GainSwitch4 #C0 S10
C1:AUX-GREEN_X_Shutter2 #C0 S15 |
12600
|
Sat Nov 5 15:45:44 2016 |
rana | Update | CDS | c1auxex channels/pins for Acromag |
We don't need to record any of the AIOut channels, the OL channels (since we record them fast), or the _MEAN channels (I think they must be CALC records or just bogus). |
12604
|
Mon Nov 7 19:49:44 2016 |
Johannes | Update | CDS | acromag chassis hooked up to PSL |
[Lydia, Johannes]
We're waiting on the last couple electrical components to arrive that are needed to complete the acromag chassis, but it is essentially operational. Right now it is connected to the PSL Mephisto's diagnostics port, for which only a single XT1221 A/D unit is needed. We assigned the IP address 192.168.113.121 to it. For the time being I'm running a tmux session on megatron (named "acromag") that grabs and broadcasts the epics channels, with Lydia's original channel definitions. Since the chassis is 4U tall, there's not really any place in the rack for it, so we might want to move it to the X-end before we start shuffling rack components around. Once we finalize its location we can proceed with adding the channels to the frames.
For the eventual gradual replacement of the slow machines, we need to put some thought into the connectors we want in the chassis. If we want to replicate the VME crate connectors we probably need to make our own PCB boards for them, as there don't seem to be panel-mount screw terminal blocks readily available for DIN 41612 connectors. Furthermore, if we want to add whitening/AA filters, the chassis may actually be large enough to accomodate them, and arranging things on the inside is quite flexible. There are a few things to be considered when moving forward, for example how many XT units we can practically fit in the chassis (space availability, heat generation, and power requirements) and thus how many channels/connectors we can support with each.
Steve: 1X3 has plenty of room |
Attachment 1: acromag_chassis_location.jpg
|
|
Attachment 2: acromag_chassis_top_view.jpg
|
|
12607
|
Tue Nov 8 17:51:09 2016 |
Lydia | Update | CDS | acromag chassis hooked up to PSL |
We set up the chassis in 1X7 today. Steve is ordering a longer 25 pin cable to reach. Until then the PSL diagnostic channels will not be usable. |
12608
|
Wed Nov 9 11:40:44 2016 |
ericq | Update | CDS | safe.snap BURT files now in svn |
This is long overdue, but our burt files for SDF now live in the LIGO userapps SVN, as they should.
The canonical files live in places like /opt/rtcds/userapps/release/cds/c1/burtfiles/c1x01_safe.snap and are symlinked to files like /opt/rtcds/caltech/c1/target/c1x01/c1x01epics/burt/safe.snap |
12610
|
Thu Nov 10 19:02:03 2016 |
gautam | Update | CDS | EPICS Freezes are back |
I've been noticing over the last couple of days that the EPICS freezes are occurring more frequently again. Attached is an instance of StripTool traces flatlining. Not sure what has changed recently in terms of the network to cause the return of this problem... Also, they don't occur coincidentally on multiple workstations, but they do pop up in both pianosa and rossa.
Not sure if it is related, but we have had multiple slow machine crashes today as well. Specifically, I had to power cycle C1PSL, C1SUSAUX, C1AUX, C1AUXEX, C1IOOL0 at some point today |
Attachment 1: epicsFreezesBack.png
|
|
12613
|
Mon Nov 14 14:21:06 2016 |
gautam | Summary | CDS | Replacing DIMM on Optimus |
I replaced the suspected faulty DIMM earlier today (actually I replaced a pair of them as per the Sun Fire X4600 manual). I did things in the following sequence, which was the recommended set of steps according to the maintenance manual and also the set of graphics on the top panel of the unit:
- Checked that Optimus was shut down
- Removed the power cables from the back to cut the standby power. Two of the fan units near the front of the chassis were displaying fault lights, perhaps this has been the case since the most recent power outage after which I did not reboot Optimus
- Took off the top cover, removed CPU 6 (labelled "G" in the unit). The manual recommends finding faulty DIMMs by looking for an LED that is supposed to indicate the location of the bad card, but I couldn't find any such LEDs in the unit we have, perhaps this is an addition to the newer modules?
- Replaced the topmost (w.r.t the orientation the CPU normally sits inside the chassis) DIMM card with one of the new ones Steve ordered
- Put everything back together, powered Optimus up again. Reboot went smoothly, fan unit fault lights which I mentioned earlier did not light up on the reboot so that doesn't look like an issue.
I then checked for memory errors using edac-utils, and over the last couple of hours, found no errors (corrected or otherwise, see Praful's earlier elog for the error messages that we were getting prior to the DIMM swap)- I guess we will need to monitor this for a while more before we can say that the issue has been resolved.
Looking at dmesg after the reboot, I noticed the following error messages (not related to the memory issue I think):
[ 19.375865] k10temp 0000:00:18.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.375996] k10temp 0000:00:19.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.376234] k10temp 0000:00:1a.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.376362] k10temp 0000:00:1b.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.376673] k10temp 0000:00:1c.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.376816] k10temp 0000:00:1d.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.376960] k10temp 0000:00:1e.3: unreliable CPU thermal sensor; monitoring disabled
[ 19.377152] k10temp 0000:00:1f.3: unreliable CPU thermal sensor; monitoring disabled
I wonder if this could explain why the fans on Optimus often go into overdrive and make a racket? For the moment, the fan volume seems normal, comparable to the other SunFire X4600s we have running like megatron and FB... |
12615
|
Mon Nov 14 19:32:51 2016 |
rana | Summary | CDS | Replacing DIMM on Optimus |
I did apt-get update and then apt-get upgrade on optimus. All systems are nominal. |
12632
|
Mon Nov 21 19:54:13 2016 |
Johannes | Update | CDS | acromag chassis hooked up to PSL |
[Lydia, Johannes]
We connected and powered up the Acromag chassis today. It lives in 1X4 and is powered by the Sorensen +20V power supply in 1X5 via the fuse rail on the side of 1X4. For this we had to branch off the 20V path to the dewhitening and anti-image filter crate of the c1:susaux driven SOS optics. After confirming that none of the daughter modules in the crate draw from the 20V line, we added a wire leading to a new fuse we added for this unit and ran a power cable from there.
The diagnostic connector of the PSL laser is now connected to the unit and a tmux session was created on megatron that interfaces with the chassis and broadcasts the EPICS channels. We need to watch out in the coming days for epics freezes/outages, as in the past these seemed to occur around the same times we were toying with the Acromags.
Quote: |
We set up the chassis in 1X7 today. Steve is ordering a longer 25 pin cable to reach. Until then the PSL diagnostic channels will not be usable.
|
|
Attachment 1: acromag_chassis.jpg
|
|
12649
|
Wed Nov 30 11:56:56 2016 |
Lydia | Update | CDS | Wiring for Acromag auxex replacement |
I've attached a schematic for how we will connect the Acromag mosules to the slow channel I/O curently going to c1auxex. The following changes are made:
- We are getting rid of the slow readbacks from the Anti-Image and Oplev boards, as Rana says they are unnnecessary.
- The whitening switching for the QPD is currently done by a Contec "fast" binary I/O module, but can be managed by acromag instead. This alllows CAB_1Y9_34 to be fed directly into the Acromag box since all of its connections can now be managed slow.
- There's no need to change the PD whitening scheme around (since the signals never get huge), so we can set those to always be on and then lose those Contec channels. This means all of the necessary pins on CAB_1Y9_10 can go to Acromag.
- All the other backplane cables go the the fast machines only.
|
Attachment 1: auxex_acromag.pdf
|
|
12651
|
Wed Nov 30 14:54:01 2016 |
Johannes | Update | CDS | Slow machine replacement |
I was talking with Larry yesterday, and he suggested the rack-mounted supermicro machines SYS-5017A-EP (~$400) or SYS-5018A-FTN4 (~$600) that he uses for moving data around in LIGO. They have ≥2 gigabit ethernet ports and can thus function as modbus gateways, conveniently placed in the rack close to the slow DAQ/DIO chassis and running some local ubuntu or other distro (I think Aidan uses CentOS in the PSL lab). These only have atom processors, which would be sufficient for the slow machine replacement, but there are many more powerful models with sometimes subtle differences. If we motion towards a more complete GigECam coverage in the lab it could be better to kill two birds with one stone and get something a little faster that can do the video capture/processing, since these machines will be distributed more or less strategically around the lab. Just a thought, as I have currently no clear idea what resources are required for this or how much we're throwing at this GigECam upgrade.
Quote: |
I've attached a schematic for how we will connect the Acromag mosules to the slow channel I/O curently going to c1auxex. The following changes are made:
- We are getting rid of the slow readbacks from the Anti-Image and Oplev boards, as Rana says they are unnnecessary.
- The whitening switching for the QPD is currently done by a Contec "fast" binary I/O module, but can be managed by acromag instead. This alllows CAB_1Y9_34 to be fed directly into the Acromag box since all of its connections can now be managed slow.
- There's no need to change the PD whitening scheme around (since the signals never get huge), so we can set those to always be on and then lose those Contec channels. This means all of the necessary pins on CAB_1Y9_10 can go to Acromag.
- All the other backplane cables go the the fast machines only.
|
|
12677
|
Wed Dec 14 19:16:57 2016 |
Lydia | Update | CDS | Acromag Binary I/O testing |
I looked into converting the QPD whitening switches for the X end to Acromag.
- To test this out and be able to freely toggle filters without messing anything up, I added a temporary dummy cdsFiltCtrl module (ACROMAG_BIO_TEST) to the c1scx model.
- The filters can be toggled from the automatically generated medm screen medm/c1scx/C1SCX_ACROMAG_BIO_TEST.adl
- The control output of the dummy filter bank is sent to a channel named C1:SCX-ACROMAG_SWCTRL.
- I was able to read in the appropriate bits from there and send them to the appropriate acromag channel using a calcout channel.
- I couldn't get individual bo channels to work. This Acromag module is configured to write to 4 channels at a time, so I set that up with an analog output channel. The calcout channel shifts each relevant bit from C1:SCX-ACROMAG_SWCTRL to the right place for writing to the Acromag.
- I connected the Acromag XT1111 Binary I/O unit to a temporary power supply and verified that toggling the filters on and off changed the output appropriately. This is a sinking output model so the output pin is connected to the return if the switch is on.

The plan from here:
- Determine how to configure these outputs to be compatible with the QPD whitening board.
- Modify the SUS PD whitening board to always use the analog filter and remove digital option in models.
- Test DACs
- Verify that the QPD whitening gain switches aren't doing anything
- Assemble new Acromag box for X end and connect to QPD whitening, SUS PD whitening and SOS driver boards
|
12699
|
Tue Jan 10 16:20:11 2017 |
Steve | Update | CDS | power glitch......Raid is rebuilding |
Jamie started the fm40m Raid rebuilding. It has been beeping since the power outage.
Summary pages have no reading since power glitch.
|
Attachment 1: rebuilding_in_progress.png
|
|
12700
|
Tue Jan 10 21:47:00 2017 |
rana | Update | CDS | power glitch |
Does "done" mean they are OK or they are somehow damaged? Do you mean the workstations or the front end machines?
The computers are all done.
|
megatron and optimus are not responding to ping commands or ssh -- please power them up if they are off; we need them to get data remotely |
12701
|
Tue Jan 10 22:55:43 2017 |
gautam | Update | CDS | power glitch - recovery steps |
Here is a link to an elog with the steps I had to follow the last time there was a similar power glitch.
The RAID array restart was also done not too long ago, we should also do a data consistency check as detailed here, if not already..
If someone hasn't found the time to do this, I can take care of it tomorrow afternoon after I am back.
Quote: |
Does "done" mean they are OK or they are somehow damaged? Do you mean the workstations or the front end machines?
The computers are all done.
|
megatron and optimus are not responding to ping commands or ssh -- please power them up if they are off; we need them to get data remotely
|
|
12702
|
Wed Jan 11 16:35:03 2017 |
gautam | Update | CDS | power glitch - recovery progress |
[lydia, ericq, gautam]
We set about following the instructions linked in the previous elog. A few notes/remarks:
- It is important to run the ntpdate commands before restarting the models. Sometimes, multiple restarts of the models were required to turn all the indicator blocks on the MEDM screen green.
- There was also an issue of multiple ntpd processes running on the same machine, which obviously caused all sorts of timing havoc. EricQ helped us diagnose and fix these. At the moment, all the lights are green on the CDS status MEDM screen

- On the hardware side, apart from the usual suspects of frontends/megatron/optimus/fb needing to be rebooted, I noticed that the ETMX OSEM lights were off on the control room monitors. Investigation pointed to the 2 20V sorensens at the X end outputting 0V, 0A after the power glitch. We turned down both dials, and then gradually ramped them up again. Both Sorensens now read +/-20V, 0.3A, which is in agreement with the label stuck onto them.
- Restarted MC autolocker and FSS Slow scripts on megatron. I have not yet looked at the status of the nds2 server on megatron.
- 11 MHz Marconi has yet to be restarted - but I am unable to get even the IMC locked at the moment. For some reason, the RMS of the MC1 and MC3 coils are way higher than what I am used to seeing (~5mV rms as compared to the <1mV rms I am used to seeing for a damped optic). I will investigate further. Leaving MC autolocker disabled for now.
|
12708
|
Thu Jan 12 17:31:51 2017 |
gautam | Update | CDS | DC errors |
The IFO is more or less back to an operational state. Some details:
- The IMC mirror excess motion alluded to in the previous elog was due to some timing issues on c1sus. The "DAC" and "DK" blocks in the c1x02 diag word were red instead of green. Restarting all the models on c1sus fixed the problem
- When c1ioo was restarted, all of Koji's changes (digital) to the MC WFS servo where lost as they were not committed to the SDF. Eric suggested that I could just restore them from burt snapshots, which is what I did. I used the c1iooepics.snap file from 12:19PM PST on 26 December 2016, which was a time when the WFS servo was working well as per this elog by Koji. I have also committed all the changes to the SDF. IMC alignment has been stable for the last 4 hours.
- Johannes aligned and locked the arms today. There was a large DC offset on POX11, which was zeroed out by closing the PSL shutter and running LSC offsets. Both arms lock and stay aligned now.
- The doubling oven controller at the Y end was switched off. Johannes turned it on.
- Eric and I started a data consistency check on the RAID array yesterday, it has completed today and indicated no issues
- NDS2 is now running again on megatron so channel access from outside should(???) be possible again.
One error persists - the "DC" indicator (data concentrator?) on the CDS medm screen for the various models spontaneously go red and return to green often. Is this a known issue with an easy fix?

|
12715
|
Fri Jan 13 21:41:23 2017 |
Koji | Update | CDS | DC errors |
I think I fixed the DC error issue
1. I added the leap second (leapsecond ?) entry for 2016/12/31, 23:60:00 UTC to daqdrc
[OLD]
set gps_leaps = 820108813 914803214 1119744016;
[NEW]
set gps_leaps = 820108813 914803214 1119744016 1167264018;
2. Restarted FB and all realtime models
Now I don't see any RED light. |
12727
|
Tue Jan 17 20:47:23 2017 |
rana | Update | CDS | Simulink Webview updated |
Seems like this stops working every ~2 years. Its been busted since early 2016 according to cron, so I fixed up the paths and restored some missing files and committed things to the SVN (with comments!) and now its working and grabbing the Web viewable versions of the front end models. Just need to restore its viewability and then the world can watch our models any time.
Quote: |
Back in 2011, JoeB wrote some entries on how to automatically update the Simulink webview stuff.
Somehow, the cron broke down over the years. I reran the matlab file by hand today and it worked fine, so now you can see the up to date models using the internet.
https://nodus.ligo.caltech.edu:30889/FE/
|
|
12754
|
Wed Jan 25 14:30:20 2017 |
gautam | Update | CDS | slow machine bootfest |
[gautam, lydia]
We rebooted c1psl, c1iscaux and c1aux which were all showing the typical symptom of responding to ping but not to telnet (and also blanked out epics fields on the MEDM screens). Keyed all these crates.
Restored burt snapshots for c1psl, PMC locked fine, and IMC is also locked now.
Johannes forgot to elog this yesterday, but he rebooted c1susaux following the usual procedure to avoid getting ITMX stuck.
|
12762
|
Fri Jan 27 17:07:52 2017 |
Lydia | Update | CDS | slow machine bootfest |
Rebooted c1iscaux, c1auxex and c1auxey which were all not reponding to telnet. The watchdogs for the ETMs were turned off and then I keyed all 3 crates. All slow machines are reponding to telnet now. Both green lasers locked to the arms so I didn't do any burt restore. |